Background Early neurological deterioration (END) is a potential predictor for 90-day outcomes following mechanical thrombectomy for acute ischemic stroke (AIS). We performed a systematic review and meta-analysis to better understand whether END can be used as a surrogate for long-term outcomes. Methods Following the PRISMA guidelines, a systematic literature review of the English language literature was conducted using PubMed, MEDLINE, and Embase. END definition was cataloged for each included study. Outcomes of interest included 90-day modified Rankin Scale (mRS) 0–2, symptomatic intracranial hemorrhage (sICH), mortality, and thrombolysis in cerebral infarction (TICI) 2b-3. We calculated pooled odds ratios (ORs) and their corresponding 95% confidence intervals (CI) for all definitions of END. Results We included seven studies with 2992 patients in our analysis. There was a significant, inverse association with END and mRS 0–2 rates (OR = 0.15; 95% CI = 0.08–0.29; P-value< 0.001). Moreover, END was a significant predictor of increased odds for reported sICH rates (OR = 16.37; 95% CI = 7.66–34.99; P-value< 0.001). Furthermore, there was a significant association between END and increase in mortality rates (OR = 6.79; 95% CI = 2.62–17.62; P-value< 0.001). There was no significant association between END and rates of TICI 2b-3 (OR = 0.53; 95% CI = 0.27–1.05; p = 0.069). Conclusions Broadly defined, END holds value as a potential predictor of rates of mRS 0–2 at 90 days and is associated with higher rates of mortality and sICH, but had no correlation with TICI 2b-3.
First-line thrombectomy strategy for distal and medium vessel occlusions: a systematic review
Background The benefit of mechanical thrombectomy (MT) and efficacy of different first-line MT techniques remain unclear for distal and medium vessel occlusions (DMVOs). In this systematic review, we aimed to compare the performance of three first-line MT techniques in DMVOs. Methods The PubMed database was searched for studies examining the utility of MT in DMVOs (middle cerebral artery M2-3-4, anterior cerebral artery, and posterior cerebral artery). Studies providing data for aspiration thrombectomy (ASP), stent retriever thrombectomy (SR), and combined SR+ASP technique were included. Non-comparative studies were excluded. Safety and efficacy data were collected for each technique. The Nested Knowledge AutoLit platform was utilized for literature search, screening, and data extraction. Pooled data were presented as descriptive statistics. Results 13 studies comprising 2422 MT procedures were identified. The overall successful recanalization rate was 77.0% (1513/1964) for DMVOs. SR+ASP had a successful recanalization rate of 83.7% (297/355), SR had a 75.6% rate (638/844), while ASP alone had a 74.2% rate (386/520). The overall functional independence rate was 51.3% (851/1659) among DMVOs. The ASP alone group had a functional independence rate of 46.9% (219/467), while functional independence rates of the SR and SR+ASP groups were 51.5% (372/723) and 61.7% (174/282), respectively. Finally, the subarachnoid hemorrhage rates were 1.8% (4/217) for the ASP group, 9.3% (26/281) for the SR group, and 11.9% (41/344) for the SR+ASP group. Conclusions Our systematic review supports the proposition that MT is a safe and effective treatment option for DMVOs. Additionally, while the SR+ASP group had consistently high rates of clot clearance and good neurological outcomes, the SR and SR+ASP groups also had higher rates of subarachnoid hemorrhage, highlighting the need for improved DMVO treatment devices.
Long-term outcomes of flow diversion for unruptured intracranial aneurysms: a systematic review and meta-analysis
Background Flow diverters have been widely used in clinical practice for more than a decade. However, most outcome data are limited to 1 year timepoints. This study aims to offer meta-analysis data on long-term (>1 year) safety and effectiveness results for patients with aneurysms treated with flow diverters. Methods PubMed, Web of Science, Embase, and SCOPUS were searched up to February 24, 2022 using the AutoLit platform. We included primary studies assessing the long-term outcomes for flow diverter devices to manage unruptured internal carotid artery aneurysms with a follow-up period of >1 year. The meta-analysis was carried out using Comprehensive Meta-Analysis software (CMA). Results Eleven studies were included in the meta-analysis. The pooled occlusion rates after flow diversion treatment for unruptured intracranial brain aneurysms were 77%, 87.4%, 84.5%, 89.4%, 96% for 1 year, 1–2 years, 2 years, 3 years, and 5 years follow-up, respectively. The in-stent stenosis rate was 4.8% and the retreatment rate for the long-term follow-up period was 5%. No delayed rupture of the aneurysm was reported, and there was one case of delayed ischemic stroke. The sensitivity analysis of the prospective studies showed a complete occlusion rate of 83.5% and 85.2% for 1 and 3 years of follow-up, respectively. Conclusion Flow diverters are safe and effective in short- and long-term follow-up and rarely cause serious delayed side effects.
Bioresorbable flow diverters for the treatment of intracranial aneurysms: review of current literature and future directions
The use of flow diverters is a rapidly growing endovascular approach for the treatment of intracranial aneurysms. All FDA-approved flow diverters are composed of nitinol or cobalt-chromium, which will remain in the patient for the duration of their life. Bioresorbable flow diverters have been proposed by several independent investigators as the next generation of flow diverting devices. These devices aim to serve their transient function of occluding and healing the aneurysm prior to being safely resorbed by the body, eliminating complications associated with the permanent presence of conventional flow diverters. Theoretical advantages of bioresorbable flow diverters include (1) reduction in device-induced thrombosis; (2) reduction in chronic inflammation and device-induced stenosis; (3) reduction in side branch occlusion; (4) restoration of physiological vasomotor function; (5) reduction in imaging artifacts; and (6) use in pediatric applications. Advances made in the similar bioresorbable coronary stenting field highlight some of these advantages and demonstrate the feasibility and safety of bioresorbable endovascular devices in the clinic. The current work aims to review the progress of bioresorbable flow diverters, identify opportunities for further investigation, and ultimately stimulate the advancement of this technology.