Citations

Clear

706 citation(s) found for "Yu, Kai".

Healing of Canine Tendon in Zones Subjected to Different Mechanical Forces
Nessler, Joseph P., Amadio, Peter C. , Berglund, L. J., An, Kai‐Nan

Mayo Clinic

Journal of Hand Surgery | July 6, 2006 | Volume: 17 | Issue: 5 | Pages: 561-568

10.1016/s0266-7681(05)80242-6 | PMID 1479251 Get It

The effect of external force environment on the healing of a partial thickness injury to canine flexor tendon was studied. A 50% laceration was made in either the fibrocartilaginous (compressive) zone or in the tendinous (tensile) zone of canine flexor digitorum profundus tendons. After three or six weeks, the tendons were harvested. An optical method for determining zone-specific material properties showed that, in response to injury, the structural stiffness decreased in the tensile zone of the tendon but increased in the compressive zone. The mechanical properties and failure mechanism of canine tendon and their changes in response to injury vary according to tendon zone, and differences in the healing process in mechanically specialised zones of the flexor tendon are discussed.
Biomechanical Efficiency of Wrist Guards as a Shock Isolator
Hwang, Il-Kyu, Kim, Kyu-Jung, Kaufman, Kenton R. , Cooney, William P., An, Kai‐Nan , Kaufman, Kenton R

Mayo Clinic

Journal of Biomechanical Engineering | March 7, 2006 | Volume: 128 | Issue: 2 | Pages: 229-234

10.1115/1.2165695 | PMID 16524335 Get It

Despite the use of wrist guards during skate- and snowboard activities, fractures still occur at the wrist or at further proximal locations of the forearm. The main objectives of this study were to conduct a human subject testing under simulated falling conditions for measurement of the impact force on the hand, to model wrist guards as a shock isolator, to construct a linear mass-spring-damper model for quantification of the impact force attenuation (Q-ratio) and energy absorption (S-ratio), and to determine whether wrist guards play a role of an efficient shock isolator. While the falling direction (forward and backward) significantly influenced the impact responses, use of wrist guards provided minimal improvements in the Q- and S-ratios. It was suggested based on the results under the submaximal loading conditions that protective functions of the common wrist guard design could be enhanced with substantial increase in the damping ratio so as to maximize the energy absorption. This would bring forth minor deterioration in the impact force attenuation but significant increase in the energy absorption by 19%, which would help better protection against fall-related injuries of the upper extremity.
Development of a Biologic Prosthetic Composite for Cartilage Repair
Mardones, Rodrigo , Reinholz, Gregory G., Fitzsimmons, James S. , Zobitz, Mark E., An, Kai‐Nan , Lewallen, David G. , Yaszemski, Michael J. , O’Driscoll, Shawn W. , Fitzsimmons, James S

Mayo Clinic

Tissue Engineering | October 31, 2005 | Volume: 11 | Issue: 9-10 | Pages: 1368-1378

10.1089/ten.2005.11.1368 | PMID 16259592 Get It

The Capitohamate Ligaments
Ritt, Marco J.P.F. , Berger, Richard A. , An, Kai‐Nan , Bishop, Allen T.

Mayo Clinic

Journal of Hand Surgery | September 21, 2005 | Volume: 21 | Issue: 4 | Pages: 451-454

10.1016/s0266-7681(96)80044-1 | PMID 8856532 Get It

The physical attributes of the three capitohamate interosseous ligaments were tested in a computer-controlled multi-axis testing machine using 12 human cadaver specimens. After an intact test run, selected ligaments were cut in random sequence and the test repeated. The remaining ligaments were tested to failure with servohydrolic stress at 5 mm/second. In the intact joint complex, the average dorsopalmar rotational displacement was approximately 9° in each direction. Under the load limit, the dorsopalmar translational displacement averaged 0.9 mm and 0.5 mm respectively, proximal–distal translational displacement averaged 0.8 mm and 0.4 mm respectively, and distractional displacement averaged 0.3 mm. Based on the sequential sectioning it was found that the dorsal ligament provided 76% (SD 14) of the rotational resistance with palmar rotation of the capitate and 44% (SD 19) of translational constraint with palmar translation of the capitate. The deep ligament provided 51% (SD 15) of the rotational resistance with dorsal rotation of the capitate and 63% (SD 24) of translational resistance with dorsal translation of the capitate. With proximal—distal translation, the dorsal ligament was the most important constraint in each direction. In resisting distraction, each of the three ligaments was equally effective. Failure testing showed the deep ligament was strongest at 289 N, followed by the palmar at 171 N and the dorsal at 133 N.
Providing Quantitative Feedback When Teaching Tendon Repair: A New Tool
Berschback, John C., Amadio, Peter C. , Zhao, Chunfeng , Zobitz, M. E., An, Kai‐Nan

Mayo Clinic

Journal of Hand Surgery | August 30, 2005 | Volume: 30 | Issue: 6 | Pages: 626-632

10.1016/j.jhsb.2005.06.013 | PMID 16131467 Get It

Flexor tendon repair remains one of the more difficult technical tasks facing the hand surgeon. A good repair must be both strong and able to glide smoothly through the tendon sheath. The purpose of this study is to present a model that allows surgeons to improve their technique of flexor tendon repair by receiving feedback on these important biomechanical parameters. The set-up requires testing equipment found in most biomechanical laboratories and should be available in many academic medical centres. Preliminary data suggest that receiving feedback about the strength and smoothness of a flexor tendon repair may be a very useful tool in helping surgeons improve the overall quality of their tendon repair technique.
“Physiological” Tensions of the Ulnar Nerve with Limb Positioning
Khoo, David Boo-Aun, Shih, Jim-Shown, Berglund, Lars , Wood, Michael B., An, Kai‐Nan

Mayo Clinic

Journal of Hand Surgery | June 17, 2005 | Volume: 19 | Issue: 1_suppl | Pages: 15-15

10.1016/0266-7681(94)90312-3 Get It

Correlation of Physiological Cross-Sectional Areas of Muscle and Tendon
An, Kai‐Nan , Linscheid, Ronald L., Brand, P W

Mayo Clinic

Journal of Hand Surgery | June 17, 2005 | Volume: 16 | Issue: 1 | Pages: 66-67

10.1016/0266-7681(91)90130-g | PMID 2007817 Get It

Muscle physiological cross-sectional area, as defined and measured by dividing the volume of the muscle by its fibre length, is proportional to the maximum strength of the muscle. It is one of the important parameters when considering muscle mechanics in sports science and, clinically in tendon transfer procedures. This study reports that tendon cross-sectional area correlated well with the physiological cross-sectional area of associated muscles.
Mechanical Properties of Human Pulleys
Lin, G.T., Cooney, W.P., Amadio, Peter C. , An, Kai‐Nan

Mayo Clinic

Journal of Hand Surgery | June 17, 2005 | Volume: 15 | Issue: 4 | Pages: 429-434

10.1016/0266-7681(90)90085-i | PMID 2269832 Get It

In order to determine the mechanical properties of the fibro-osseous pulleys in the hand, the diaphyseal annular pulleys, the volar plate annular pulleys and the cruciate or condensable portions were tested. A custom-made loading device provided proper fit of the soft tissues for a uniform distribution of the pulley load during testing. The A2 pulley was found to be the strongest of the pulleys; the A1 and A4 were the next strongest. The A3 pulley was nearly equal in mean breaking strength to the other annular pulleys, but in absolute breaking load was considerably weaker because of its shortness. The A4 was the least compliant of the pulleys. We concluded that the fibro-osseous A2 and A4 were mechanically stronger and stiffer pulleys than the A1, A3, A5 (volar plate) pulleys. In testing one type of pulley reconstruction, we found that the “belt loop” technique of Karev nearly matched the annular pulleys in strength and energy absorption.
Dynamic Mechanical Properties of Agarose Gels Modeled by a Fractional Derivative Model
Chen, Qingshan , Suki, Bélâ , An, Kai‐Nan

Mayo Clinic

Journal of Biomechanical Engineering | November 23, 2004 | Volume: 126 | Issue: 5 | Pages: 666-671

10.1115/1.1797991 | PMID 15648820 Get It

The complex modulus E* and elastic modulus E′ of agarose gels (2% to 4%) are measured with a dynamic mechanical analyzer in frequency sweep shear sandwich mode between 0.1 and 20 Hz. The data showed that E* and E′ increase with frequency according to a power law which can be described by a fractional derivative model to characterize the dynamic viscoelasticity of the gel. The functions between the model parameters including storage modulus coefficient H and the power law exponent (β) and the agarose concentration are established. A molecular basis for the application of the fractional derivative model to gel polymers is also discussed. Such an approach can be useful in tissue culture studies employing dynamic pressurization or for validation of magnetic resonance elastography.
Muscle forces analysis in the shoulder mechanism during wheelchair propulsion
Su, Fong‐Chin , Wu, Hong-Wen, An, Kai‐Nan , Lin, Hwai‐Ting

Mayo Clinic

Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine | August 3, 2004 | Volume: 218 | Issue: 4 | Pages: 213-221

10.1243/0954411041561027 | PMID 15376723 Get It

This study combines an ergometric wheelchair, a six-camera video motion capture system and a prototype computer graphics based musculoskeletal model (CGMM) to predict shoulder joint loading, muscle contraction force per muscle and the sequence of muscular actions during wheelchair propulsion, and also to provide an animated computer graphics model of the relative interactions. Five healthy male subjects with no history of upper extremity injury participated. A conventional manual wheelchair was equipped with a six-component load cell to collect three-dimensional forces and moments experienced by the wheel, allowing real-time measurement of hand/rim force applied by subjects during normal wheelchair operation. An Expert Vision™ six-camera video motion capture system collected trajectory data of markers attached on anatomical positions. The CGMM was used to simulate and animate muscle action by using an optimization technique combining observed muscular motions with physiological constraints to estimate muscle contraction forces during wheelchair propulsion. The CGMM provides results that satisfactorily match the predictions of previous work, disregarding minor differences which presumably result from differing experimental conditions, measurement technologies and subjects. Specifically, the CGMM shows that the supraspinatus, infraspinatus, anterior deltoid, pectoralis major and biceps long head are the prime movers during the propulsion phase. The middle and posterior deltoid and supraspinatus muscles are responsible for arm return during the recovery phase. CGMM modelling shows that the rotator cuff and pectoralis major play an important role during wheelchair propulsion, confirming the known risk of injury for these muscles during wheelchair propulsion. The CGMM successfully transforms six-camera video motion capture data into a technically useful and visually interesting animated video model of the shoulder musculoskeletal system. The CGMM further yields accurate estimates of muscular forces during motion, indicating that this prototype modelling and analysis technique will aid in study, analysis and therapy of the mechanics and underlying pathomechanics involved in various musculoskeletal overuse syndromes.