Citations

Clear

802 citation(s) found for "Sanchez, S".

Recurrent Syncope, a Clue in Amyloid Cardiomyopathy
Marin‐Acevedo, Julian A. , Sánchez-Álvarez, Catalina , Alsaad, Ali A. , Pagán, Ricardo J. , Sanchez-Alvarez, Catalina

Mayo Clinic

Case Reports in Medicine | January 28, 2018 | Volume: 2018 | Issue: No issue available | Pages: 1-6

10.1155/2018/1864962 | PMID 29559999 Get It

Infiltrative cardiomyopathies include a variety of disorders that lead to myocardial thickening resulting in a constellation of clinical manifestations and eventually heart failure that could be the first clue to reach the diagnosis. Among the more described infiltrative diseases of the heart is amyloid cardiomyopathy. The disease usually presents with subtle, nonspecific symptoms. Herein, we illustrate a case of recurrent syncope as the initial presenting symptom for systemic amyloid with polyneuropathy and cardiomyopathy as a cause of syncope. The article illustrates the role of advanced cardiac imaging in the diagnosis of the disease with a focused literature review. We also highlight the role of early, shared decision-making between patient, family, and medical team in the management of cardiac amyloidosis.
Allograft-Prosthetic Composite Reconstruction for Massive Proximal Humeral Bone Loss in Reverse Shoulder Arthroplasty
Sánchez‐Sotelo, Joaquín , Wagner, Eric R. , Sanchez-Sotelo, J. , Wagner, Eric R , Houdek, Matthew T.

Mayo Clinic

JBJS Essential Surgical Techniques | January 24, 2018 | Volume: 8 | Issue: 1 | Pages: e3

10.2106/jbjs.st.17.00051 | PMID 30233975 Get It

Background: Allograft-prosthetic composite (APC) reconstruction of the humerus represents an appealing surgical technique when implantation of a reverse prosthesis is considered in the setting of substantial proximal humeral bone loss 1–4 . Humeral APCs have been successfully performed in the past with a non-reverse shoulder prosthesis 4,5 . Reconstruction of the proximal part of the humerus with an allograft provides adequate support and fixation for the humeral component, allows restoration of length and lateral offset, and provides an opportunity for soft-tissue reattachment when needed. On the basis of the available peer-reviewed data, healing at the allograft-host junction is reliable, and complication rates, including instability, are relatively low 3,6 . Description: Once the glenoid reverse component has been implanted, a proximal humeral allograft is prepared to receive the humeral component of a reverse arthroplasty. The allograft is procured by our institutional bone and tissue bank, purchased from a number of vendors. The graft is selected after review of the description and radiographs provided by the vendor. The priority is to obtain a graft with sufficient length and soft tissues attached. If possible, the graft selected should have a diameter close to the diameter of the humerus of the recipient. The desired allograft length is selected on the basis of preoperative planning and intraoperative measurements, and the distal portion of the allograft is resected accordingly. Depending on the length of the defect, host bone quality, and surgeon preferences, the humeral component may or may not bypass the host-graft junction. The stem bypasses the host-graft junction for shorter APCs, as well as when the bone quality of the native humerus is compromised. Cemented fixation into the graft is universally used. Compression plating is used for graft-to-host fixation, supplemented by implantation of the stem across the junction in selected cases. Care is taken during the freehand cut to obtain optimal contact and compression. Once the ideal humeral bearing thickness has been selected, the polyethylene bearing is implanted and the joint relocated. If the posterior cuff can be repaired to cuff allograft, sutures are placed prior to relocation and are tied after relocation. Other musculotendinous units, such as the deltoid or pectoralis major, are repaired to the allograft if needed. Alternatives: Implantation of a reverse prosthesis with a proximal humeral metal body (a so-called tumor prosthesis) is the main alternative to proximal humeral APC reconstruction. In patients with shorter defects, adequate soft-tissue tension may be obtained by implanting a glenosphere with a large inferior eccentricity and cementing the humeral component in a more proximal position than is usually performed. Alternatively, when implantation of the glenoid component of a reverse prosthesis is not possible, a hemiarthroplasty-APC construct may be performed 1,4,5,7–10 , adding a synthetic sleeve such as an aortic Dacron graft to enhance soft-tissue stability if needed. Rationale: When reverse arthroplasty is performed in the setting of substantial humeral bone loss, the humeral component may be poorly supported and at risk for loosening. In addition, the absence of proximal humeral bone stock may lead to shortening and/or loss of lateral offset. Finally, the posterosuperior cuff, subscapularis, deltoid, and pectoralis tendons may remain detached. The potential consequences of humeral bone loss in the setting of reverse arthroplasty include humeral loosening, dislocation, and poor active motion (particularly poor active elevation). Allograft reconstruction of the proximal part of the humerus provides an opportunity for better support of the component, restoration of humeral length and lateral offset, and attachment sites for the musculotendinous structures around the shoulder, if needed.
Anatomic Total Shoulder Arthroplasty Using a Self-Pressurizing Pegged Bone-Preserving Cemented Glenoid Component: A 2- to 5-Year Follow-up Study
Nguyen, Ngoc Tram V. , Sánchez‐Sotelo, Joaquín , Morrey, Mark E.

Mayo Clinic

Journal of Shoulder and Elbow Arthroplasty | January 12, 2018 | Volume: 2 | Issue: No issue available | Pages: No page available

10.1177/2471549217750478 Get It

Background: High rates of radiographic loosening have been reported with various glenoid designs. Many available designs sacrifice most of the bone at the central portion of the glenoid vault, creating large areas of deficiency when revision becomes necessary. The purpose of this study was to report the 2- to 5-year outcome of shoulder arthroplasty using a bone-preserving all-polyethylene glenoid components with self-pressurizing pegs. Methods: Between August 2011 and December 2014, 202 consecutive anatomic total shoulder arthroplasties (TSAs) were performed by a single surgeon with implantation of a self-pressurizing cemented pegged glenoid component in 190 patients (12 patients had both shoulders replaced). Patients were followed up prospectively and evaluated for pain, motion, strength, American Shoulder and Elbow Surgeons (ASES) scores, and radiographic changes. The mean follow-up time was 2.7 (2–5) years. Results: TSA improved pain and function reliably. At the most recent follow-up, 94% of the shoulders had no or mild pain. Motion included 154 ± 25° of elevation, 68 ± 18° of external rotation, and median internal rotation to T10 (range, iliac crest to T4). The most recent average ASES score was 82 ± 15 points. Early postoperative radiographs showed no radiolucent lines. No humeral or glenoid component was considered radiographically loose at the most recent follow-up. Complications requiring reoperation included subscapularis insufficiency (4), posterior instability (2), deep infection (1), stiffness (1), and a painful loose body (1). No components were revised for loosening. Conclusions: Anatomic TSA using a cemented bone-preserving all-polyethylene pegged self-pressurizing glenoid component provided satisfactory clinical outcomes and survival at 2 to 5 years.
Relationships between lewy and tau pathologies in 375 consecutive non‐Alzheimer's olfactory bulbs
Kasanuki, Koji , Ross, Owen A. , DeTure, Michael , Walton, Ronald L., Koga, Shunsuke , Murray, Melissa E. , Rademakers, Rosa , DeTure, Michael A, Koga, Shunsuke , Ross, Owen A , Murray, Melissa E , Sánchez-Contreras, Mónica , Dickson, Dennis W.

Mayo Clinic

Movement Disorders | January 11, 2018 | Volume: 33 | Issue: 2 | Pages: 333-334

10.1002/mds.27250 | PMID 29322556 Get It

Possible modulation of release of atrial natriuretic factor by endothelium-derived relaxing factor
Sánchez‐Ferrer, Carlos F. , Burnett, John C. , Lorenz, Robert R. , Vanhoutte, Paul M.

Mayo Clinic

American Journal of Physiology-Heart and Circulatory Physiology | December 21, 2017 | Volume: 259 | Issue: 3 | Pages: H982-H986

10.1152/ajpheart.1990.259.3.h982 | PMID 2144405 Get It

The aim of the present study was to investigate the influence of inhibitors of endothelium-dependent relaxing factor on the release of atrial natriuretic factor from isolated rat atria. Electrical stimulation of the tissue produced a frequency-dependent increase in secretion of atriopeptide from basal levels. Saponin (0.3 mg/ml for 45 min) augmented the basal release of the peptide. Methylene blue (10(-5)M), oxyhemoglobin (10(-6)M), or hydroquinone (10(-5)M), agents that inhibit the effects of endothelium-derived relaxing factor by different mechanisms, caused an increase in the basal secretion of atrial natriuretic factor. Blockade of cyclooxygenase with indomethacin (10(-5)M) did not alter the release of atriopeptide, suggesting that it is not controlled by endogenous prostaglandins. These results would be explained if the inhibitors tested were to interfere with a factor released continuously from either endocardial cells or endothelial cells of the atrial blood vessels and having the same nature as endothelium-derived relaxing factor. Such release may exert a tonic negative modulatory influence on the secretion of atrial natriuretic factor.
Allograft-Prosthetic Composite Reconstruction for Massive Proximal Humeral Bone Loss in Reverse Shoulder Arthroplasty
Sánchez‐Sotelo, Joaquín , Wagner, Eric R. , Sim, Franklin H. , Sanchez-Sotelo, J. , Wagner, Eric R , Houdek, Matthew T.

Mayo Clinic

Journal of Bone and Joint Surgery | December 21, 2017 | Volume: 99 | Issue: 24 | Pages: 2069-2076

10.2106/jbjs.16.01495 | PMID 29257012 Get It

Background: Reverse total shoulder arthroplasty (RTSA) performed in the setting of massive proximal humeral bone loss often requires special reconstructive techniques. Restoration of the proximal part of the humerus with an allograft provides a number of theoretical benefits, including implant support, restoration of humeral length, deltoid tensioning, and an opportunity to repair the posterior aspect of the cuff to improve strength in external rotation and repair of the subscapularis to improve stability. However, reverse allograft-prosthesis composites (APCs) are costly, are technically demanding to use, and can be compromised by progressive allograft resorption. Methods: Between 2005 and 2012, the lead author used an APC reconstruction in 8 primary and 18 revision RTSAs (26 patients; mean age, 62 years; mean body mass index, 27.9 kg/m 2 ). The indications for the primary RTSAs included severe proximal humeral bone loss after trauma (n = 5) and tumor resection (n = 3). The indications in the revision setting were failed hemiarthroplasty (n = 11), anatomic total shoulder arthroplasty (n = 4), and reverse arthroplasty (n = 3). The most common reason for revision was instability (n = 10). A compression plate was used for graft-to-host fixation in all shoulders. Shoulders were assessed for pain, motion, American Shoulder and Elbow Surgeons (ASES) score, Simple Shoulder Test (SST) score, Neer score, revision or reoperation, radiographic evidence of graft union or resorption, and implant fixation. The mean duration of follow-up was 4 years (range, 2 to 10 years). Results: RTSA using an APC construct resulted in substantial improvements in pain scores (p < 0.0001), elevation (p < 0.0001), and external rotation (p = 0.004). With the numbers available, there were no significant differences in clinical outcomes between primary and revision cases. No patients required revision surgery for nonunion at the host-allograft junction. The mean time to union was 7 months, with 1 patient requiring bone-grafting for delayed union. Other complications included dislocation, deep infection, graft fracture, and periprosthetic fracture distal to the previous APC construct in 1 patient each. The 2 and 5-year revision-free survival rate was 96%. Conclusions: Reconstruction of proximal humeral bone loss with an APC at the time of primary or revision RTSA is safe and effective, with acceptable functional outcomes and complication rates. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Powassan virus postencephalitic parkinsonism
Mittal, Shivam Om , Hassan, Anhar , Sanchez, Joyce L. , Robertson, Carrie E. , Sanchez, Joyce, Robertson, Carrie E , Mittal, Shivam Om

Mayo Clinic

Neurology Clinical Practice | December 11, 2017 | Volume: 7 | Issue: 6 | Pages: 527-530

10.1212/cpj.0000000000000391 | PMID 29431163 Get It

Pneumatosis Cystoides Intestinalis
Sanchez, Luz Helena Gutierrez , Absah, Imad , Sanchez, Luz Helena Gutierrez , Gutierrez Sanchez, Luz Helena

Mayo Clinic

Journal of Pediatric Gastroenterology and Nutrition | November 22, 2017 | Volume: 68 | Issue: 3 | Pages: No page available

10.1097/mpg.0000000000001845 | PMID 29176475 Get It