Citations

Clear

9383 citation(s) found for "Thomas, PS".

Impact of hypercortisolism on skeletal muscle mass and adipose tissue mass in patients with adrenal adenomas
Delivanis, Danae A. , Iñiguez‐Ariza, Nicole M. , Zeb, Muhammad, Moynagh, Michael R., Takahashi, Naoki , McKenzie, Travis J. , Thomas, Melinda, Gogos, Charalambos, Kyriazopoulou, Venetsana, Zeb, Muhammad H, Thomas, Melinda A, Young, William F. , Bancos, Irina , Takahashi, Naoki

Mayo Clinic

Clinical Endocrinology | November 8, 2017 | Volume: 88 | Issue: 2 | Pages: 209-216

10.1111/cen.13512 | PMID 29115003 Get It

SummaryContextAbdominal visceral adiposity and central sarcopenia are markers of increased cardiovascular risk and mortality.ObjectiveTo assess whether central sarcopenia and adiposity can serve as a marker of disease severity in patients with adrenal adenomas and glucocorticoid secretory autonomy.DesignRetrospective cohort study.PatientsTwenty‐five patients with overt Cushing's syndrome (CS), 48 patients with mild autonomous cortisol excess (MACE) and 32 patients with a nonfunctioning adrenal tumour (NFAT) were included.MethodsMedical records were reviewed, and body composition measurements (visceral fat [VAT], subcutaneous fat [SAT], visceral/total fat [V/T], visceral/subcutaneous [V/S] and total abdominal muscle mass) were calculated based on abdominal computed tomography (CT).ResultsIn patients with overt CS, when compared to patients with NFAT, the V/T fat and the V/S ratio were increased by 0.08 (P < .001) and by 0.3 (P < .001); however, these measurements were decreased by 0.04 (P = .007) and 0.2 (P = .01), respectively, in patients with MACE. Total muscle mass was decreased by −10 cm2 (P = .02) in patients with overt CS compared to patients with NFAT. Correlation with morning serum cortisol concentrations after dexamethasone suppression testing revealed that for every 28 nmol/L cortisol increase there was a 0.008 increase in V/T (P < .001), 0.02 increase in the V/S fat ratio (P < .001) and a 1.2 cm2 decrease in mean total muscle mass (P = .002).ConclusionsThe severity of hypercortisolism was correlated with lower muscle mass and higher visceral adiposity. These CT‐based markers may allow for a more reliable and objective assessment of glucocorticoid‐related disease severity in patients with adrenal adenomas.
Opioid Neurotoxicity Treated with Intrathecal Drug Delivery System Implant
Wu, Kelly L. , Strand, Jacob J. , Moeschler, Susan M. , Pittelkow, Thomas P.

Mayo Clinic

Journal of Palliative Medicine | November 7, 2017 | Volume: 21 | Issue: 2 | Pages: 126-126

10.1089/jpm.2017.0517 | PMID 29112460 Get It

Letter by Maltais et al Regarding Article, “Hemocompatibility-Related Outcomes in the MOMENTUM 3 Trial at 6 Months: A Randomized Controlled Study of a Fully Magnetically Levitated Pump in Advanced Heart Failure”
Maltais, Simon, Tchantchaleishvili, Vakhtang , Stulak, John M., Tchantchaleishvili, Vakhtang

Mayo Clinic

Circulation | November 6, 2017 | Volume: 136 | Issue: 19 | Pages: 1870-1871

10.1161/circulationaha.117.028984 | PMID 29109201 Get It

Left Lateral Thoracotomy for Centrifugal Continuous-Flow Left Ventricular Assist Device Placement: An Analysis from the Mechanical Circulatory Support Research Network
Maltais, Simon, Anwer, Lucman A. , Tchantchaleishvili, Vakhtang , Haglund, Nicholas, Cowger, Jennifer , Salerno, Christopher T. , Shah, Palak , Khalpey, Zain , Schmitto, Jan D. , Stulak, John M., Dunlay, Shannon M. , Tchantchaleishvili, Vakhtang , Aaronson, Keith D. , Pagani, Francis D. , Shah, Palak

Mayo Clinic

ASAIO Journal | November 3, 2017 | Volume: 64 | Issue: 6 | Pages: 715-720

10.1097/mat.0000000000000714 | PMID 29095733 Get It

Continuous-flow left ventricular assist devices (CF-LVADs) have revolutionized the management of patients with advanced heart failure. Alternative implant strategies are increasingly used for device placement. We reviewed our experience from the Mechanical Circulatory Support Research Network registry with the HeartWare centrifugal CF-LVAD (HVAD). From May 2004 to August 2015, 1,150 patients underwent primary CF-LVAD implantation at our institutions. Within this group, a total of 283 patients (25%) were implanted with the HVAD. A minimally invasive left lateral thoracotomy (MILT) implant strategy was used in 53 patients (20%), of which 22 (42%) were implanted off-pump. Median age at implant was 59 years and 183 patients (65%) were implanted as bridge-to-transplantation. Follow-up was 100% complete for a total of 302 patient-years of support. In-hospital mortality was 4.9% (14 patients), and was comparable between the conventional sternotomy (CS) and MILT cohorts (p = 0.15). Patients in the MILT cohort had a shorter median length of stay (p < 0.01) and had a lower incidence of postimplant pump thrombus (p = 0.02). Cumulative survival at the end of follow-up reached 84%, and was comparable between the two groups (p = 0.298). Multivariate analysis identified preoperative bilirubin level as the only independent predictor of survival. Surgical technique had no impact on survival. In this large, multicenter experience, data demonstrate excellent survival and adverse event profiles for patients supported with the HVAD technology, regardless of surgical implant technique. With constant advancements in device technology along with our increasing clinical experience with the newer techniques, minimally invasive LVAD implantation continues to evolve as a valuable alternative to CS in selected patients.
Single Versus Multidrug Regimen for Surgical Infection Prophylaxis in Left Ventricular Assist Device Implantation
Aburjania, Nana , Ertmer, Brennan, Farid, Saira, Berg, Melody L. , Nienaber, Juhsien J. C., Tchantchaleishvili, Vakhtang , Stulak, John M., Sohail, M. Rizwan , Ertmer, Brennan M, Sohail, Muhammad R, Sohail, M Rizwan , Tchantchaleishvili, Vakhtang , Baddour, Larry M.

Mayo Clinic

ASAIO Journal | November 3, 2017 | Volume: 64 | Issue: 6 | Pages: 735-740

10.1097/mat.0000000000000710 | PMID 29095735 Get It

Infection is a serious complication of left ventricular assist device (LVAD) therapy. However, an optimal antimicrobial surgical infection prophylaxis (SIP) regimen for LVAD implantation is not well established. We retrospectively reviewed all adults who underwent continuous-flow LVAD implantation from February 2007 to March 2015 at Mayo Clinic Rochester. Left ventricular assist device infection (LVADI) was defined using criteria published by the International Society for Heart and Lung Transplant. Patients excluded from the analysis included those who did not have HeartMate II or HeartWare device, patients with incomplete documentation of SIP, and those with an actively treated infection at the time of LVAD implantation. We compared risk of LVAD-specific and LVAD-related infections and all-cause mortality between SIP regimens at postoperative day 90 and 1 year using Kaplan–Meier time-to-event analyses. During study period, 239 adults underwent continuous-flow LVAD implantation at our institution where 199 patients received single-drug and 40 received multidrug SIP regimen. Median patient age was 62 years. Left ventricular assist device infection occurred in three patients (1.5%) in the single-drug group versus two patients (5.0%) in the multidrug group at 90 days (p = 0.4). There was no difference in infection-free (p = 0.4) and overall survival (p = 0.9) between two groups at 1 year. In conclusion, there was no clear benefit of using multidrug regimen as it did not impact infection-free survival or all-cause mortality compared with single-drug regimen. Prospective clinical trials are needed to further define the optimal SIP regimen for LVAD implantation.
Pulmonary arteriovenous extracorporeal membrane oxygenation to avoid pulmonary overflow during total artificial heart implantation
Tchantchaleishvili, Vakhtang , Luc, Jessica G.Y. , Sagebin, Fabio, Massey, H. Todd , Tchantchaleishvili, Vakhtang , Wong, Joshua K.

Mayo Clinic

The International Journal of Artificial Organs | November 3, 2017 | Volume: 41 | Issue: 1 | Pages: 66-68

10.5301/ijao.5000655 | PMID 29099541 Get It

Total artificial hearts (TAH) can be used as a bridge to transplant or, occasionally, as destination therapy for patients with severe biventricular dysfunction. Not infrequently TAHs are placed in patients with severe low flow states, in which the lungs of these patients are unable to adjust rapidly to the “normal” right ventricular output of a TAH. These patients may develop variable degrees of pulmonary edema secondary to stress failure of the pulmonary capillaries requiring increased respiratory support, which can occasionally be fatal. In this “how to do it” article, we describe the technique for a pulmonary arteriovenous extracorporeal membrane oxygenation with TAH to avoid sudden pulmonary overflow and gradually expose the lungs to increasing flow.
Dual antiplatelet therapy in aneurysmal subarachnoid hemorrhage: association with reduced risk of clinical vasospasm and delayed cerebral ischemia
Nagahama, Yasunori , Allan, Lauren , Nakagawa, Daichi , Starke, Robert M. , Chalouhi, Nohra , Brown, Robert D., Derdeyn, Colin P. , Leira, Enrique C. , Chimowitz, Marc I. , Torner, James C., Hasan, David , Torner, James C. , Zanaty, Mario , Jabbour, Pascal , Broderick, Joseph P. , Derdeyn, Colin P

Mayo Clinic

Journal of Neurosurgery | November 3, 2017 | Volume: 129 | Issue: 3 | Pages: 702-710

10.3171/2017.5.jns17831 | PMID 29099296 Get It

OBJECTIVE Clinical vasospasm and delayed cerebral ischemia (DCI) are devastating complications of aneurysmal subarachnoid hemorrhage (aSAH). Several theories involving platelet activation have been postulated as potential explanations of the development of clinical vasospasm and DCI. However, the effects of dual antiplatelet therapy (DAPT; aspirin and clopidogrel) on clinical vasospasm and DCI have not been previously investigated. The objective of this study was to evaluate the effects of DAPT on clinical vasospasm and DCI in aSAH patients. METHODS Analysis of patients treated for aSAH during the period from July 2009 to April 2014 was performed in a single-institution retrospective study. Patients were divided into 2 groups: patients who underwent stent-assisted coiling or placement of flow diverters requiring DAPT (DAPT group) and patients who underwent coiling only without DAPT (control group). The frequency of symptomatic clinical vasospasm and DCI and of hemorrhagic complications was compared between the 2 groups, utilizing univariate and multivariate logistic regression. RESULTS Of 312 aSAH patients considered for this study, 161 met the criteria for inclusion and were included in the analysis (85 patients in the DAPT group and 76 patients in the control group). The risks of clinical vasospasm (OR 0.244, CI 95% 0.097–0.615, p = 0.003) and DCI (OR 0.056, CI 95% 0.01–0.318, p = 0.001) were significantly lower in patients receiving DAPT. The rates of hemorrhagic complications associated with placement of external ventricular drains and ventriculoperitoneal shunts were similar in both groups (4% vs 2%, p = 0.9). CONCLUSIONS The use of DAPT was associated with a lower risk of clinical vasospasm and DCI in patients treated for aSAH, without an increased risk of hemorrhagic complications.
Coiling of a Carotidocavernous Fistula via the Foramen Ovale: 2-Dimensional Operative Video
Brinjikji, Waleed , Sorenson, Thomas J. , Atkinson, John D. , Cloft, Harry J. , Sorenson, Thomas, Cloft, Harry, Atkinson, John, Lanzino, Giuseppe

Mayo Clinic

Operative Neurosurgery | November 2, 2017 | Volume: 14 | Issue: 6 | Pages: 709-709

10.1093/ons/opx224 | PMID 29106646 Get It

Atrial Fibrillation Should Guide Prophylactic Tricuspid Procedures During Left Ventricular Assist Device Implantation
Anwer, Lucman A. , Tchantchaleishvili, Vakhtang , Poddi, Salvatore , Daly, Richard C. , Joyce, Lyle D., Kushwaha, Sudhir S. , Topilsky, Yan , Stulak, John M., Maltais, Simon, Topilsky, Yan , Tchantchaleishvili, Vakhtang , Topilsky, Yan

Mayo Clinic

ASAIO Journal | October 31, 2017 | Volume: 64 | Issue: 5 | Pages: 586-593

10.1097/mat.0000000000000698 | PMID 29088022 Get It

Atrial fibrillation (AF) and tricuspid regurgitation (TR) are common in patients undergoing left ventricular assist device (LVAD) implantation. TR progression is associated with the presence of AF, and questions remain as to who benefits from tricuspid valve procedures (TVPs). We examined the impact of preoperative AF on TR progression after LVAD implantation. From February 2007 to May 2014, 250 patients underwent LVAD implantation at our institution. Patients with concomitant TVP were excluded from this analysis (113 patients). The indication for LVAD was destination therapy in 80 patients (58%) and the etiology of heart failure was ischemic in 73 (53%). Follow-up was available in all early survivors for a total of 393 patient-years of support. Of the 137 non-TVP patients, 52 (38%) had AF preoperatively. Observed overall survival at 1, 3, and 5 years was 82%, 67%, and 55%, respectively. Median grade of TR increased from 2 preoperatively to 3 (p = 0.04) in the AF group and 2.2 (p = 0.75) in the non-AF group at 5 years of follow-up. We also observed a significant difference in the degree of TR between groups at 3 months (p = 0.03) and 12 months (p = 0.01) postimplantation, and a trend toward significance at 18 (p = 0.06) and 24 (p = 0.07) months. The presence of AF is associated with early progression of TR after LVAD implantation. Addition of concomitant TVP in patients with preoperative AF may be considered in patients with less than severe TR. The impact of these findings on right ventricular failure/remodeling remains to be evaluated.
Optimizing Emergency Department Workflow Using Radio Frequency Identification Device (RFID) Data Analytics
Arunachalam, Shivaram P. , Sır, Mustafa Y. , Marisamy, Gomathi, Sadosty, Annie T., Nestler, David M. , Hellmich, Thomas , Arunachalam, S P , Pasupathy, Kalyan S.

Mayo Clinic

2017 Design of Medical Devices Conference | October 31, 2017 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2017-3402 Get It

Emergency Department (ED) is a complex care delivery environment in a hospital that provides time sensitive urgent and lifesaving care [1]. Emergency medicine is an unscheduled practice and therefore providers experience extreme fluctuations in their workload. ED crowding is a major concern that affects the efficacy of the ED workflow, which often is challenged by long wait times, overuse of observation units, patients either leaving without being seen by a provider and non-availability of inpatient beds to accommodate patients after diagnosis [2]. Evaluating ED workflow is a challenging task due to its chaotic nature, with some success using time-motion studies and novel capacity management tools are nowadays becoming common in ED to address workflow related issues [3]. Several studies reveal that Electronic Medical Record (EMR) adoption has not resulted in significant ED workflow improvements nor reduced the cost of ED operations. Since raw EMR data does not offer operational and clinical decision making insights, advanced EMR data analytics are often sought to derive actionable intelligence from EMR data that can provide insights to improve ED workflow. Improving ED workflow has been an important topic of research because of its great potential to optimize the urgent care needed for the patients and at the same time save time and cost. Radio Frequency Identification Device (RFID) is a wireless automatic identification and data capture technology device that has the potential for improving safety, preventing errors, saving costs, and increasing security and therefore improving overall organizational performance. RFID technology use in healthcare has opened a new space in healthcare informatics research that provides novel data to identify workflow process pitfalls and provide new directions [4]. The potential advantages of RFID adoption in healthcare and especially in ED has been well recognized to save costs and improve care delivery [5]. However, the large upfront infrastructure costs, need for an integrated health information technology (HIT), advanced analytical tools for big data analysis emerging from RFID and skilled data scientists to tackle the data to derive actionable intelligence discourage many hospitals from adoption RFID technology despite its potential advantages. Our recent pilot study on the RFID data analytics demonstrated the feasibility of quantifying and analyzing two novel variables such as ‘patient alone’ time defined as the total time a patient spends alone without interaction with a health care staff in the ED and ‘provider time’ defined as the total time a patient spends interacting with any health care staff [6]. The study motivated a more comprehensive big data analytics of RFID data which can provide better insights into optimizing ED workflow which can improve the quality of care in the ED and also reduce cost. In this work, the authors attempt to describe the RFID adoption in the ED at the Saint Mary’s Hospital at Mayo Clinic, in Rochester, MN, a level one trauma center both for children and adults as a step towards optimizing ED workflow.