Citations

Clear

1266 citation(s) found for "Xu, Nancy".

Long-term survival after traumatic brain injury: A population-based analysis
Leibson, Cynthia L., Malec, James F. , Perkins, Patricia K., Diehl, Nancy N. , Brown, Allen W. , Larson, Dirk R.

Mayo Clinic

NeuroRehabilitation | January 21, 2020 | Volume: 19 | Issue: 1 | Pages: 37-43

10.3233/nre-2004-19105 Get It

Biomarkers in Patients with Heart Failure and Central Sleep Apnoea: Findings From the SERVE-HF Trial
Ferreira, João Pedro , Duarte, Kévin, Woehrle, Holger , Cowie, Martín , Angermann, Christiane E. , d’Ortho, Marie‐Pia , Erdmann, Erland , Lévy, Patrick , Simonds, Anita K. , Teschler, Helmut, Rossignol, Patrick , Köenig, Wolfgang , Zannad, Faı̈ez , Lévy, Patrick , Koenig, Wolfgang , Ferreira, João Pedro , Cowie, Martin R , Wegscheider, Karl , Somers, Virend K.

Mayo Clinic

ESC Heart Failure | January 17, 2020 | Volume: 7 | Issue: 2 | Pages: 503-511

10.1002/ehf2.12521 | PMID 31951323 Get It

Abstract Aims The Treatment of Sleep-Disordered Breathing with Predominant Central Sleep Apnoea by Adaptive Servo Ventilation in Patients with Heart Failure trial investigated the effects of adaptive servo-ventilation (ASV) (vs. control) on outcomes of 1325 patients with heart failure and reduced ejection fraction (HFrEF) and central sleep apnoea (CSA). The primary outcome (a composite of all-cause death or unplanned HF hospitalization) did not differ between the two groups. However, all-cause and cardiovascular (CV) mortality were higher in the ASV group. Circulating biomarkers may help in better ascertain patients' risk, and this is the first study applying a large set of circulating biomarkers in patients with both HFrEF and CSA. Methods and results Circulating protein-biomarkers (n = 276) ontologically involved in CV pathways, were studied in 749 (57% of the trial population) patients (biomarker substudy), to investigate their association with the study outcomes (primary outcome, CV death and all-cause death). The mean age was 69 ± 10 years, and > 90% were male. The groups (ASV vs. control and biomarker substudy vs. no biomarker) were well balanced. The “best” clinical prognostic model included male sex, systolic blood pressure < 120 mmHg, diabetes, loop diuretic, cardiac device, 6-min walking test distance, and N-terminal pro BNP as the strongest prognosticators. On top of the “best” clinical prognostic model, the biomarkers that significantly improved both the discrimination (c-index) and the net reclassification index (NRI) of the model were soluble suppression of tumorigenicity 2 for the primary outcome; neurogenic locus notch homolog protein 3 (Notch-3) for CV-death and all-cause death; and growth differentiation factor 15 (GDF-15) for all-cause death only. Conclusions We studied 276 circulating biomarkers in patients with HFrEF and central sleep apnoea; of these biomarkers, three added significant prognostic information on top of the best clinical model: soluble suppression of tumorigenicity 2 (primary outcome), Notch-3 (CV and all-cause death), and GDF-15 (all-cause death).
Protein‐elongating mutations inMYH11are implicated in a dominantly inherited smooth muscle dysmotility syndrome with severe esophageal, gastric, and intestinal disease
Gilbert, Melissa A. , Schultz‐Rogers, Laura , Wilkins, Benjamin J. , Biswas, Sawona , Conlin, Laura K. , Fiorino, Kristin, Dhamija, Radhika , Pack, Michael , Klee, Eric W. , Piccoli, David A., Spinner, Nancy B. , Spinner, Nancy B , Dhamija, Radhika , Rajagopalan, Ramakrishnan , Grochowski, Christopher M.

Mayo Clinic

Human Mutation | January 16, 2020 | Volume: 41 | Issue: 5 | Pages: 973-982

10.1002/humu.23986 | PMID 31944481 Get It

Brentuximab vedotin with chemotherapy for stage III/IV classical Hodgkin lymphoma: 3-year update of the ECHELON-1 study
Straus, David J. , Długosz‐Danecka, Monika , Alekseev, Sergey , Lech‐Marańda, Ewa , Feldman, Tatyana , Smolewski, Piotr , Bartlett, Nancy L. , Walewski, Jan , Ramchandren, Radhakrishnan , Hutchings, Martin , Radford, John , Kim, Won Seog , Advani, Ranjana H. , Ansell, Stephen M. , Younes, Anas , Miao, Harry , Liu, Rachael , Fenton, Keenan , Forero‐Torres, Andres , Gallamini, Andrea , Bartlett, Nancy L , Advani, Ranjana H , Liu, Rachael , Lech-Maranda, Ewa , Radford, John , Illés, Árpád , Picardi, Marco , Savage, Kerry J. , Zinzani, Pier Luigi , Connors, Joseph M. , Muñoz, Javier

Mayo Clinic

Blood | January 16, 2020 | Volume: 135 | Issue: 10 | Pages: 735-742

10.1182/blood.2019003127 | PMID 31945149 Get It

Abstract The phase 3 ECHELON-1 study demonstrated that brentuximab vedotin (A) with doxorubicin, vinblastine, and dacarbazine (AVD; A+AVD) exhibited superior modified progression-free survival (PFS) vs doxorubicin, bleomycin, vinblastine, and dacarbazine (ABVD) for frontline treatment of patients with stage III/IV classical Hodgkin lymphoma (cHL). Maturing positron emission tomography (PET)-adapted trial data highlight potential limitations of PET-adapted approaches, including toxicities with dose intensification and higher-than-expected relapse rates in PET scan after cycle 2 (PET2)-negative (PET2−) patients. We present an update of the ECHELON-1 study, including an exploratory analysis of 3-year PFS per investigator. A total of 1334 patients with stage III or IV cHL were randomized 1:1 to receive 6 cycles of A+AVD (n = 664) or ABVD (n = 670). Interim PET2 was required. At median follow-up of 37 months, 3-year PFS rates were 83.1% with A+AVD and 76.0% with ABVD; 3-year PFS rates in PET2− patients aged <60 years were 87.2% vs 81.0%, respectively. A beneficial trend in PET2+ patients aged <60 years on A+AVD was also observed, with a 3-year PFS rate of 69.2% vs 54.7% with ABVD. The benefit of A+AVD in the intent-to-treat population appeared independent of disease stage and prognostic risk factors. Upon continued follow-up, 78% of patients with peripheral neuropathy on A+AVD had either complete resolution or improvement compared with 83% on ABVD. These data highlight that A+AVD provides a durable efficacy benefit compared with ABVD for frontline stage III/IV cHL, consistent across key subgroups regardless of patient status at PET2, without need for treatment intensification or bleomycin exposure. This trial was registered at www.clinicaltrials.gov as #NCT01712490 (EudraCT no. 2011-005450-60).
Establishment of an internationally agreed minimum data set for acute telestroke
Cadilhac, Dominique A. , Bagot, Kathleen L. , Hubert, G. , Watkins, Caroline , Lightbody, Catherine Elizabeth , Kim, Joosup , Vu, Michelle , Pompeani, Nancy , Switzer, Jeffrey A. , Caudill, Juanita, Estrada, Juan , Viswanathan, Anand , Hubert, Nikolai , Ohannessian, Robin , Hargroves, David , Roberts, Nicholas , Ingall, Timothy J., Hess, David C. , Ranta, Annemarei , Padma, Vasantha, Bladin, Christopher F., Pompeani, Nancy , Ohannessian, Robin , Ingall, Timothy, Ranta, Annemarei , Demaerschalk, Bart M. , Schwamm, Lee H. , Roberts, Nicholas

Mayo Clinic

Journal of Telemedicine and Telecare | January 14, 2020 | Volume: 27 | Issue: 9 | Pages: 582-589

10.1177/1357633x19899262 | PMID 31937198 Get It

Introduction Globally, the use of telestroke programmes for acute care is expanding. Currently, a standardised set of variables for enabling reliable international comparisons of telestroke programmes does not exist. The aim of the study was to establish a consensus-based, minimum dataset for acute telestroke to enable the reliable comparison of programmes, clinical management and patient outcomes. Methods An initial scoping review of variables was conducted, supplemented by reaching out to colleagues leading some of these programmes in different countries. An international expert panel of clinicians, researchers and managers ( n = 20) from the Australasia Pacific region, USA, UK and Europe was convened. A modified-Delphi technique was used to achieve consensus via online questionnaires, teleconferences and email. Results Overall, 533 variables were initially identified and harmonised into 159 variables for the expert panel to review. The final dataset included 110 variables covering three themes (service configuration, consultations, patient information) and 12 categories: (1) details about telestroke network/programme ( n = 12), (2) details about initiating hospital ( n = 10), (3) telestroke consultation ( n = 17), (4) patient characteristics ( n = 7), (5) presentation to hospital ( n = 5), (6) general clinical care within first 24 hours ( n = 10), (7) thrombolysis treatment ( n = 10), (8) endovascular treatment ( n = 13), (9) neurosurgery treatment ( n = 8), (10) processes of care beyond 24 hours ( n = 7), (11) discharge information ( n = 5), (12) post-discharge and follow-up data ( n = 6). Discussion The acute telestroke minimum dataset provides a recommended set of variables to systematically evaluate acute telestroke programmes in different countries. Adoption is recommended for new and existing services.
Association Between 21-Gene Assay Recurrence Score and Locoregional Recurrence Rates in Patients With Node-Positive Breast Cancer
Buchholz, Thomas A. , Shak, Steven , Baehner, Frederick L. , Whelan, Timothy J. , Davidson, Nancy E. , King, Tari A. , Ravdin, Peter M., Osborne, C. Kent , Tripathy, Debasish , Livingston, Robert B., Hayes, Daniel F. , Albain, Kathy S. , Tripathy, Debu , Ingle, James N. , Woodward, Wendy A , Barlow, William E. , Jagsi, Reshma , Gralow, Julie R. , Hortobágyi, Gabriel N. , Whelan, Timothy J

Mayo Clinic

JAMA Oncology | January 9, 2020 | Volume: 6 | Issue: 4 | Pages: 505

10.1001/jamaoncol.2019.5559 | PMID 31917424 Get It

In Vivo Imaging and Autoradiography in a Case of Autopsy-Confirmed Pick Disease
Murray, Melissa E. , Tranovich, Jessica F., Scott, Nancy E. , Lowe, Val J. , Whitwell, Jennifer L. , Josephs, Keith A. , Murray, Melissa E , Utianski, Rene L. , Schwarz, Christopher G.

Mayo Clinic

Neurology Clinical Practice | January 6, 2020 | Volume: 11 | Issue: 1 | Pages: No page available

10.1212/cpj.0000000000000755 | PMID 33968481 Get It

Brain-infiltrating cytolytic T lymphocytes specific for Theiler's virus recognize H2Db molecules complexed with a viral VP2 peptide lacking a consensus anchor residue
Borson, Nancy D., Lin, Xiaoqi , Nevala, Wendy K. , Strausbauch, Michael, Wettstein, Peter J., Paul, C, Rodriguez, Moses

Mayo Clinic

Journal of Virology | January 6, 2020 | Volume: 71 | Issue: 7 | Pages: 5244-5250

10.1128/jvi.71.7.5244-5250.1997 | PMID 9188592 Get It

Mice expressing the H2b haplotype are resistant to infection with Theiler's murine encephalomyelitis virus (TMEV), which causes chronic demyelination in susceptible mice. The prominent cytolytic T-lymphocyte (CTL) response to the VP2 antigen encoded by TMEV led us to the identification of a class I-binding peptide derived from the VP2 antigen. Escherichia coli transformants overexpressing a series of 11 overlapping VP2 protein fragments were subjected to lysis and alkali digestion, and the resultant peptide pools were tested for their abilities to sensitize RMA-S targets for lysis by CTLs. The source of effector CD8+ T cells for the assays was either freshly harvested central nervous system-infiltrating lymphocytes (CNS-IL) or CNS-IL-derived VP2-specific CTL clones and lines. A 10-residue peptide at VP2 positions 121 to 130 (VP2(121-130)) (FHAGSLLVFM) was identified that sensitized targets for lysis and formed stable complexes with H2Db class I molecules. The VP2(121-130) peptide sensitized target cells for lysis by freshly harvested CNS-IL CTLs at femtomolar concentrations. Despite its relative high level of biological activity, the VP2(121-130) peptide is distinguished from other Db-binding peptides by its lack of an asparagine residue at position five, which had been previously proposed to be a requirement for Db-peptide complexing.
Clinical comparison of BACTEC 9240 plus aerobic/F resin bottles and the isolator aerobic culture system for detection of bloodstream infections
Cockerill, Franklin R., Reed, G S, Torgerson, C A, Vetter, Emily A., Harmsen, William S. , Dale, J C, Roberts, Glenn D., Ilstrup, D M, Henry, Nancy K., Hughes, J G

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 35 | Issue: 6 | Pages: 1469-1472

10.1128/jcm.35.6.1469-1472.1997 | PMID 9163464 Get It

The Plus Aerobic/F resin bottle of the BACTEC 9240 automated blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) was compared with aerobic culture of the Isolator system (Wampole Laboratories, Cranbury, N.J.) for the detection of bloodstream microorganisms from 6,145 blood cultures collected from adult patients with suspected septicemia. The BACTEC resin bottles were incubated for 7 days, and the sediment from the Isolator tube was inoculated to sheep blood and chocolate agars which were incubated for 72 h and to inhibitory mold, brain heart infusion, and Sabouraud agars which were incubated for 21 days. A total of 622 microorganisms were recovered from 583 blood cultures. The BACTEC resin bottle recovered statistically significantly more pathogens overall than the Isolator system (P = 0.0006). When individual pathogens isolated from either system for a 7-day study period were assessed, it was determined that the BACTEC resin bottle detected statistically significantly more isolates of Staphylococcus aureus (P = 0.0113) and coagulase-negative Staphylococcus spp. (P = 0.0029) than the Isolator system. The BACTEC resin bottle also detected statistically significantly more bloodstream infections (septic episodes) caused by coagulase-negative Staphylococcus spp. (P = 0.0146). The Isolator system recovered statistically significantly more contaminants overall (P < 0.0001), and among this group of microorganisms, recovered statistically significantly more Bacillus spp. (P < 0.0001), coagulase-negative Staphylococcus spp. (P < 0.0001), and viridans group Streptococcus spp. (P = 0.0156). The Isolator system detected statistically significantly more isolates of Histoplasma capsulatum (P = 0.004), but all of these isolates were detected at > or = 7 days of incubation of fungal plates, i.e., after the system to system comparison study period (7 days). In blood culture sets which produced growth of the same pathogen in both systems, there was a statistically significant difference in median time to detection for all pathogens combined favoring the BACTEC resin bottle over the Isolator tube (P < 0.05). When assessing individual microorganisms, the median times for detection of S. aureus, Enterococcus spp., and Pseudomonas spp. were all statistically significantly less for the BACTEC system (P < 0.05). The BACTEC instrument had 79 (1.3%) false positive signals. The BACTEC system required less processing time than the Isolator system and eliminates the hands-on time for detection of positive cultures required with the Isolator system.
Clinical comparison of difco ESP, Wampole isolator, and Becton Dickinson Septi-Chek aerobic blood culturing systems
Cockerill, Franklin R., Torgerson, C A, Reed, G S, Vetter, Emily A., Weaver, Amy L. , Dale, J C, Roberts, Glenn D., Henry, Nancy K., Ilstrup, D M, Rosenblatt, Jon E.

Mayo Clinic

Journal of Clinical Microbiology | January 6, 2020 | Volume: 34 | Issue: 1 | Pages: 20-24

10.1128/jcm.34.1.20-24.1996 | PMID 8748264 Get It

The ESP 80A aerobic blood culture of the ESP automated blood culture system (Difco Laboratories. Detroit, Mich.) was compared with two manual aerobic blood culture systems, the Isolator (Wampole Laboratories, Cranbury, N.J.) and the Septi-Chek (Becton Dickinson, Cockeysville, Md.) systems, for the detection of bloodstream microorganisms from 5,845 blood samples for culture collected from adult patients with suspected septicemia. The bottles were incubated for 7 days, and the sediment from the Isolator tube was inoculated onto solid medium and this medium was incubated for 72 h. A total of 609 microorganisms were recovered from 546 blood cultures. There was no statistically significant difference in the total recovery of microorganisms for the ESP 80A system when compared with that for the Septi-Chek system (P = 0.083); however, the Isolator system recovered significantly more microorganisms overall than either the ESP 80A (P < 0.001) or the Septi-Chek (P < 0.001) system. When assessing individual probable pathogens, the Isolator system detected statistically significantly more Staphylococcus aureus and Candida spp. than either the ESP 80A or the Septi-Chek system (P < 0.05). Similarly, the Isolator system detected statistically significantly more bloodstream infections (septic episodes) caused by S. aureus and Candida spp. than either the ESP 80A or the Septi-Chek system (P < 0.05). In blood culture sets which produced growth of the same probable pathogens in the ESP 80A and the Isolator systems, there was no statistically significant difference in the median times to detection for all pathogens combined (P = 0.067). However, a similar comparison showed the Isolator and the ESP 80A systems to have statistically significantly shorter median detection times for all pathogens combined (P < 0.001) when they were independently compared with the Septi-Chek system. The ESP 80A system had 29 (0.5%) false-positive signals. The ESP system required less processing time than the Isolator system and eliminates the hands-on time for the detection of positive cultures required by the manual systems.