Microsurgery is considered one of the most demanding surgical techniques. In a recent American Society of Reconstructive Microsurgeons survey, respondents reported that about half their procedures lasted 8 hours or longer and 8% had tremor during their surgery. Thus, the aim of this study was to define user centered design requirements for a microsurgery armrest, create low-fidelity armrest design concepts and evaluate microsurgeons’ perspectives on the advantages/disadvantages of five potential design concepts. Direct and videotaped observations of microsurgery, user brainstorming during a co-creation workshop and semi-structured interviews were used. The resulting five microsurgery armrest concepts were presented pictorially through semi-structured interviews, where microsurgeons defined armrest design requirements as: a) an armrest that allows the surgeons to be as close as possible to the patient; b) adjustable to accommodate different procedures sites and surgeon preferences; c) rigid enough to support arms; d) is not difficult to set up; nor e) large or bulky; and f) complies with operative sterility rules. This study illustrated how involving the users (microsurgeons) early in the design process provides useful perspectives on design requirements and implementation barrier for a cost-effective ergonomic microsurgery armrest to foster sound ergonomic surgical practice and reduce musculoskeletal health risk factors during microsurgery.
Mini Breaks, Many Benefits: Development and Pilot Testing of an Intraoperative Microbreak Stretch Web-Application for Surgeons
Periodic intraoperative microbreaks with calesthenic exercises performed within the sterile field improved self-reported mental focus (38%) and physical performance (57%) for 56 surgeons. Therefore, targeted stretching exercises and a web-application (web-app) leading the stretches with a reminder system were developed and piloted using user-centered design principles. A focus group with 10 users was conducted to refine the developed app. Seven surgeons (4 females) at a quaternary medical institute piloted the periodic stretching web-app in their operating rooms. At the end of each surgical day, the surgeons completed a short survey about the intraoperative stretching exercises web-app impact on their physical performance, mental focus and workflow disruption. Non-Routine Events were captured during the procedures. Twelve surgical days were followed with a median of 6 microbreaks/day/surgeon. Results showed that better physical performance and lower fatigue were reported (91.7%) across the surgical days, also better mental focus was reported (83.3%) across the surgical days, and less pain/discomfort was reported (100%) across the surgical days, with others reporting no change. The web-app leading sterile field microbreak stretches helped reduce physical pain, discomfort/pain, fatigue, and improve mental focus with minimal disruption for a small sample. The web-app is a promising tool for improving surgeon mental focus and physical performance and potentially musculoskeletal health.
NASA-TLX Assessment of Surgeon Workload Variation Across Specialties
Objective: With advancements in surgical equipment and procedures, human–system interactions in operating rooms affect surgeon workload and performance. Workload was measured across surgical specialties using surveys to identify potential predictors of high workload for future performance improvement. Summary Background Data: Surgical instrumentation and technique advancements have implications for surgeon workload and human–systems interactions. To understand and improve the interaction of components in the work system, NASA-Task Load Index can measure workload across various fields. Baseline workload measurements provide a broad overview of the field and identify areas most in need of improvement. Methods: Surgeons were administered a modified NASA-Task Load Index survey (0 = low, 20 = high) following each procedure. Patient and procedural factors were retrieved retrospectively. Results: Thirty-four surgeons (41% female) completed 662 surgery surveys (M = 14.85, SD = 7.94), of which 506 (76%) have associated patient and procedural data. Mental demand (M = 7.7, SD = 5.56), physical demand (M = 7.0, SD = 5.66), and effort (M = 7.8, SD = 5.77) were the highest rated workload subscales. Surgeons reported difficulty levels higher than expected for 22% of procedures, during which workload was significantly higher ( P < 0.05) and procedural durations were significantly longer ( P > 0.001). Surgeons reported poorer perceived performance during cases with unexpectedly high difficulty ( P < 0.001). Conclusions: When procedural difficulty is greater than expected, there are negative implications for mental and physical demand that result in poorer perceived performance. Investigations are underway to identify patient and surgical variables associated with unexpected difficulty and high workload. Future efforts will focus on re-engineering the surgical planning process and procedural environment to optimize workload and performance for improved surgical care.
Evidence-based intraoperative microbreak activities for reducing musculoskeletal injuries in the operating room
With advancements in surgical techniques, patients have experienced improvements in health and recovery outcomes. However, about 87% of laparoscopic surgeons [1] and an increasing number of surveyed allied health professionals [2, 3] report musculoskeletal symptoms. Medical practitioners and human factors engineers have highlighted the “hostile” and “dangerous” operating room (OR) environment [1, 4, 5]. With increasing technology and surgical case complexity, physical demands for surgical team members will continue to increase due to circumstances such as technology restricting posture, taking up working space and more team members working around smaller surgical incisions [6]. There is widespread concern that these medical professionals’ work is unsustainable for safe and healthy patients and surgical team members. Surgical team members can benefit from posture improvement during surgery; however, direct postural feedback may be difficult during their work due to the high visual and auditory stimuli during surgery. The tactile modality has been recently explored as a method to provide additional information without interfering with cognitive resources dedicated to visual and auditory pathways [7]. Tactile devices have successfully been implemented in high-stress environments, e.g., military, healthcare, and rehabilitation with a resulting improvement in performance [8–11]. Vibrotactile feedback has been specifically implemented in the healthcare field for improved performance by 31–75% anesthesiologists during simulated tasks [10]. Additionally, it has contributed to improved postural control in rehabilitation patients[11]. Despite success in other application areas, the potential of tactile devices for improving healthcare workers’ safety and performance remains unexplored. This study is a part of a larger project to design a wearable device that provides realtime vibrotactile feedback for preventing fatigue and musculoskeletal disorders for healthcare workers in the workplace. This specific aim of this study is to measure distraction, frustration, and performance during a surgical simulation task performed with and without vibrotactile feedback. This is a test of initial feasibility of vibrotactile feedback for use in training proper ergonomics for surgical team members. The researchers hypothesize that there will be some distraction with the vibrotactile feedback wearable but no frustration or performance degradation during the basic simulation task.
Human Factors Applications to Mitigate Design Limitations of a Wearable Telemedicine Heart Rate Monitor
The time required to get a device to market is critical to a successful design, development, and manufacturing process [1]. Achieving status of the first device to market is often a priority for manufacturers and developers. Upon market introduction, it is well known that device performance must meet at least minimum standards in order to provide consumer satisfaction and be a successful product to prevent competitive devices from taking over the market [1]. However, if a design only meets minimum expectations, it may struggle to maintain market control. This demonstrates the tradeoffs of speed-to-market and performance, for which optimization has not been clearly defined [2]. Product performance and usability can be designed in, evaluated and enhanced in order to avoid user errors and achieve optimal profitability. For medical devices, clinical trials are a key step in preparing to take a device to market. Clinical trials can allow for analyses of the effectiveness of the device in the patient care process. For wearable medical devices, patient usability is crucial to patient adherence and safety since the device will be operated by non-medically trained individuals [3,4]. Without adequate usability, adherence and continuity of care are greatly reduced which will reduce the overall effectiveness of the device [5,6]. Human factors principles can best be incorporated in the design process to improve the usability of medical devices and patient safety [5,6,7], specifically for those used in telemedicine [4] and cardiovascular treatment [3]. The objective of this project was to evaluate a telemedicine heart rate monitoring device for patient usability in order to improve the next device’s performance and lead to greater patient adherence for the current version via an improved user manual.
Iterative Implementation of a Remote Cardiac Patient Monitoring Device using Qualitative Analysis and Human Factors Engineering
Remote monitoring has the potential to improve patient care and satisfaction while reducing the cost of care and burden on the healthcare system for Congestive Heart Failure (CHF) and Atrial Fibrillation (AF) patients. However, the device must be convenient and easy for the population to use correctly. In this study, human factors and qualitative researchers evaluated the use of a remote cardiac monitoring device during a clinical trial with 74 CHF and AF patients. Human factors usability concerns centered on device use and the information presented in the manual. The key themes identified during the qualitative analysis were related to patient education. These findings were incorporated into device design, user manual, or education material updates. This study illustrates how these methods can infuse patient experience into device design to inform continued quality improvement and usability refinement specifically in devices to aid CHF and AF patients without added burden.
A Preliminary Comparison of Three Tourniquet Instructions for Just-in-Time Guidance of a Simulated Tourniquet Application
The American College of Surgeons (ACS) and the Department of Homeland Security (DHS) encourage the use of tourniquets as part of the “Stop the Bleed” campaign. Both have provided instructions for layperson tourniquet application in order to save the life of a hemorrhaging trauma victim. This study sought to compare the impact of using ACS and DHS instructions with manufacturer-provided instructions for the completion of simulated tourniquet application steps. Thirty surgical trainees completed a simulated tourniquet application with one of the three instruction sets. Their completion time and success for each step were measured. Participants that received ACS instructions failed the fewest number of steps (p < 0.01) and completed the task faster (Mean (SD) = 70 (33) seconds) compared to those with the manufacturer-provided instructions (p < 0.01). Tourniquet instruction sets need to be refined in order to optimize the success rate of just-in-time guidance for tourniquet application.
Physician Interruptions and Workload during Emergency Department Shifts
Interruptions in the Emergency Department (ED) are moderately studied in regard to their impact on physicians’ workload. This study captured interruptions characteristics and measures of workload. Twenty-eight ED physicians were followed during their shifts; interruptions they faced were captured using a validated tablet PC-based tool. At the mid and end of their shift, providers completed a NASA-Task Load Index (TLX) questionnaire and a reaction time task. Descriptive statistics and ANOVA were used to identify relationships between physicians’ interruptions and workload. A total of 2355 interruptions were identified ( M =84.1, SD =14.5). The NASA-TLX results showed increase in physicians’ responses for all subscales from mid to end-shifts. Reaction time was higher at end-shift with mean difference of 33.75ms, 95% CI [20.35, 47.13], p < 0.001. At end-shift, there was a statistically significant positive correlation between reaction time and all NASA-TLX subscales. Interruption duration rather than frequency correlated positively with NASA-TLX scores. High/critical interruptions were the least frequent but had longer duration and greater impact on workload. This study provided a unique examination of interruptions over an entire provider shift and identified interruptions as potential causes of increased workload for ED physicians.
Do Trauma Activations Affect Interruptions in the Emergency Department?
Clinicians have anecdotally indicated that interruptions increase following trauma activations in the emergency department (ED), yet it is unknown whether interruptions change following the end of a trauma case. This study aimed to examine the interruption characteristics of clinicians that participate in trauma activations before and after activations using the SEIPS model. Observers shadowed ED clinicians across entire shifts and logged interruptions that affected clinicians in a tablet PC-based tool. Interruption characteristics captured included duration, nature, location, and task priority. Trauma activations lasting more than five minutes were also recorded. Only interruptions occurring within one-hour of trauma activations were included in the analysis. Chi-square analyses identified significant associations between SEIPS-categorized interruptions and the interruption priority, p < 0.01, and between the SEIPS-categorized interruptions and the interruption location, p = 0.01, pre- and post-trauma activations. Identifying these associations revealed key opportunities to reduce unnecessary interruptions in the ED.