Proton therapy is increasingly widespread and requires an accelerator to provide the high energy protons. Most often, the accelerators used for proton therapy are cyclotrons and the maximum initial beam energy (MIBE) is about 230 MeV or more to be able to achieve a range of approximately 30 cm in water. We ask whether such a high energy is necessary for adequate dosimetry for pathologies to be treated with proton beams. Eight patients of different clinical sites (brain, prostate, and head and neck cancers) were selected to conduct this study. We analyzed the tumor dose coverage and homogeneity, as well as healthy tissue protection for MIBE values of 120, 160, 180, 200 and 230 MeV. For each patient, a proton plan was developed using the particular MIBE and then using multifield optimization (MFO). In this way, 34 plans in total were generated to fulfill the unique clinical goals. This study found that MIBE of 120 MeV for brain tumors; 160 MeV for head and neck cancer; and remarkably, for prostate cancer, only 160 MeV for one patient case and 180 MeV for the remainder satisfied the clinical goals (words: 187 < approx. 200 words or less)
Enhanced IDOL segmentation framework using personalized hyperspace learning IDOL
AbstractBackgroundAdaptive radiotherapy (ART) workflows have been increasingly adopted to achieve dose escalation and tissue sparing under shifting anatomic conditions, but the necessity of recontouring and the associated time burden hinders a real‐time or online ART workflow. In response to this challenge, approaches to auto‐segmentation involving deformable image registration, atlas‐based segmentation, and deep learning‐based segmentation (DLS) have been developed. Despite the particular promise shown by DLS methods, implementing these approaches in a clinical setting remains a challenge, namely due to the difficulty of curating a data set of sufficient size and quality so as to achieve generalizability in a trained model.PurposeTo address this challenge, we have developed an intentional deep overfit learning (IDOL) framework tailored to the auto‐segmentation task. However, certain limitations were identified, particularly the insufficiency of the personalized dataset to effectively overfit the model. In this study, we introduce a personalized hyperspace learning (PHL)‐IDOL segmentation framework capable of generating datasets that induce the model to overfit specific patient characteristics for medical image segmentation.MethodsThe PHL‐IDOL model is trained in two stages. In the first, a conventional, general model is trained with a diverse set of patient data (n = 100 patients) consisting of CT images and clinical contours. Following this, the general model is tuned with a data set consisting of two components: (a) selection of a subset of the patient data (m < n) using the similarity metrics (mean square error (MSE), peak signal‐to‐noise ratio (PSNR), structural similarity index (SSIM), and the universal quality image index (UQI) values); (b) adjust the CT and the clinical contours using a deformed vector generated from the reference patient and the selected patients using (a). After training, the general model, the continual model, the conventional IDOL model, and the proposed PHL‐IDOL model were evaluated using the volumetric dice similarity coefficient (VDSC) and the Hausdorff distance 95% (HD95%) computed for 18 structures in 20 test patients.ResultsImplementing the PHL‐IDOL framework resulted in improved segmentation performance for each patient. The Dice scores increased from 0.810.05 with the general model, 0.83 for the continual model, 0.83 for the conventional IDOL model to an average of 0.87 with the PHL‐IDOL model. Similarly, the Hausdorff distance decreased from 3.06 with the general model, 2.84 for the continual model, 2.79 for the conventional IDOL model and 2.36 for the PHL‐IDOL model. All the standard deviations were decreased by nearly half of the values comparing the general model and the PHL‐IDOL model.ConclusionThe PHL‐IDOL framework applied to the auto‐segmentation task achieves improved performance compared to the general DLS approach, demonstrating the promise of leveraging patient‐specific prior information in a task central to online ART workflows.
LET‐based approximation of the microdosimetric kinetic model for proton radiotherapy
AbstractBackgroundPhenomenological relative biological effectiveness (RBE) models for proton therapy, based on the dose‐averaged linear energy transfer (LET), have been developed to address the apparent RBE increase towards the end of the proton range. The results of these phenomenological models substantially differ due to varying empirical assumptions and fitting functions. In contrast, more theory‐based approaches are used in carbon ion radiotherapy, such as the microdosimetric kinetic model (MKM). However, implementing microdosimetry‐based models in LET‐based proton therapy treatment planning systems poses challenges.PurposeThis work presents a LET‐based version of the MKM that is practical for clinical use in proton radiotherapy.MethodsAt first, we derived an approximation of the Mayo Clinic Florida (MCF) MKM for relatively‐sparsely ionizing radiation such as protons. The mathematical formalism of the proposed model is equivalent to the original MKM, but it maintains some key features of the MCF MKM, such as the determination of model parameters from measurable cell characteristics. Subsequently, we carried out Monte Carlo calculations with PHITS in different simulated scenarios to establish a heuristic correlation between microdosimetric quantities and the dose averaged LET of protons.ResultsA simple allometric function was found able to describe the relationship between the dose‐averaged LET of protons and the dose‐mean lineal energy, which includes the contributions of secondary particles. The LET‐based MKM was used to model the in vitro clonogenic survival RBE of five human and rodent cell lines (A549, AG01522, CHO, T98G, and U87) exposed to pristine and spread‐out Bragg peak (SOBP) proton beams. The results of the LET‐based MKM agree well with the biological data in a comparable or better way with respect to the other models included in the study. A sensitivity analysis on the model results was also performed.ConclusionsThe LET‐based MKM integrates the predictive theoretical framework of the MCF MKM with a straightforward mathematical description of the RBE based on the dose‐averaged LET, a physical quantity readily available in modern treatment planning systems for proton therapy.
A Randomized Comparison of Postprandial Glucose Excursion Using Inhaled Insulin Versus Rapid-Acting Analog Insulin in Adults With Type 1 Diabetes Using Multiple Daily Injections of Insulin or Automated Insulin Delivery
OBJECTIVE To compare postprandial glucose excursions following a bolus with inhaled technosphere insulin (TI) or subcutaneous rapid-acting analog (RAA) insulin. RESEARCH DESIGN AND METHODS A meal challenge was completed by 122 adults with type 1 diabetes who were using multiple daily injections (MDI), a nonautomated pump, or automated insulin delivery (AID) and who were randomized to bolus with their usual RAA insulin (n = 61) or TI (n = 61). RESULTS The primary outcome, the treatment group difference in area under the curve for glucose >180 mg/dL over 2 h, was less with TI versus RAA (adjusted difference −12 mg/dL, 95% CI −22 to −2, P = 0.02). With TI, the glucose excursion was smaller (P = 0.01), peak glucose lower (P = 0.01), and time to peak glucose shorter (P = 0.006). Blood glucose <70 mg/dL occurred in one participant in each group. CONCLUSIONS Postmeal glucose excursion was smaller with TI than with RAA insulin in a cohort that included both AID and MDI users.
Dosimetric consequences of flap dose due to rapid beam off control for a high intensity carbon ion radiation therapy synchrotron
AbstractBackgroundIn carbon ion radiation therapy (CIRT) the predominant method of irradiation is raster scanning, called dose driven continuous scanning (DDCS) by Hitachi, allowing for continuous synchrotron extraction. The reduction in irradiation time is highly beneficial in minimizing the impact of patient and target movement on dose distribution. The RF knock out (RFKO) slow‐extraction method is commonly used for beam on/off control. When the Hitachi synchrotron receives a beam off signal the control system stops the RFKO and after some delay time (t‐delay) during which the beam intensity declines, a high‐speed steering magnet (HSST) is used to sweep the remaining beam from isocenter to a beam dump for safety reasons. Mayo Clinic Florida (MCF) will use a very short delay of the HSST operation from the RFKO beam OFF signal to minimize the delay time and delayed dose. MCF clinical beam intensity, a tenfold increase over HIMAK, is still less than 100 mMU/ms (approximately 4.9 × 109 pps for 430 MeV/u).PurposeThe rapid beam off control (RBOC) proposed for MCF is associated with the occurrence of flap dose (FD), which refers to the asymmetric shoulder of the spot dose profile formed from the beam bent by HSST deviating from its planned spot position on the isocenter plane. In this study, we quantitatively assessed FD, proposed a treatment planning system (TPS) implementation using a flap spot (FS) and evaluated its impact on dose distribution.MethodThe experiments were conducted at the Osaka Heavy Ion Therapy Center (HIMAK) varying the t‐delay from 0.01 to 1 ms in a research environment to simulate the MCF RBOC. We studied the dependence of FD position on beam transport and its dependence on energy and beam intensity. FD was generated by delivering 10000 continuous spots on the central axis that are occasionally triggered by an external 10 Hz gate signal. Measurements were conducted using an oscilloscope, and the nozzle's spot position monitor (SPM) and dose monitor (DM).ResultAll spot profile data were corrected for the gain of the SPM's beam intensity dependence. FD was determined by fitting the (SPM) Profile data to a double Gaussian. The position of the FS was found to be transport path dependent, with FS occurring on the opposite sides of the scanning x‐direction for vertical and horizontal ports, respectively, as predicted by transport calculations. It was observed that the FD increases with beam intensity and did not exhibit a significant dependence on energy. The effect of FD on treatment planning is shown to have no significant dose impact on the organs at risk (OARs) near the target for clinical beam intensities and a modest increase for very high intensities.ConclusionUsing HIMAK in research mode the implications are that the FD has no clinical impact on the clinical CIRT beam intensities for MCF and maybe planned for higher intensities by incorporating FS into the TPS to predict the modest increased dose to OARs. A method for commissioning and quality assurance of FD has been proposed.
Comparative Evaluation of Two Analytical Functions for the Microdosimetry of Ions from 1H to 238U
The analytical microdosimetric function (AMF) implemented in the Monte Carlo code PHITS is a unique tool that bridges the gap between macro- and microscopic scales of radiation interactions, enabling accurate microdosimetric calculations over macroscopic bodies. The original AMF was published in 2006, based on the results of track structure calculations. Recently, a newer version of the AMF was proposed, incorporating an improved description of the energy loss at the microscopic scale. This study compares the older and the newer AMFs in computing microdosimetric probability distributions, mean values, and the relative biological effectiveness (RBE). To this end, 16000 microdosimetric lineal energy probability density distributions were simulated with PHITS for ions from 1H to 238U over a broad energy range (1–1000 MeV/n). The newer AMF was found to offer superior performance, particularly for very heavy ions, producing results that align more closely with published in vitro clonogenic survival experiments. These findings suggest that the updated AMF provides a more reliable tool for microdosimetric calculations and RBE modeling, essential for ion radiation therapy and space radiation protection.
Optimizing spot intensity with lower bound constraints for IMPT: Exposing shortcomings and introducing an enhanced strategy
AbstractBackgroundIntensity Modulated Proton Therapy (IMPT) is a sophisticated radiation treatment allowing for precise dose distributions. However, conventional spot selection strategies in IMPT face challenges, particularly with minimum monitor unit (MU) constraints, affecting planning quality and efficiency.PurposeThis study introduces an innovative Two‐Stage Mixed Integer Linear Programming (MILP) method to optimize spot intensity in IMPT with Lower Bound (LB) constraints. This method seeks to improve treatment planning efficiency and precision, overcoming limitations of existing strategies.MethodsOur approach evaluates prevalent IMPT spot selection strategies, identifying their limitations, especially concerning MU constraints. We integrated LB constraints into a MILP framework, using a novel three‐phase strategy for spot pool selection, to enhance performance over traditional heuristic methods and L1 + L∞ strategies. The method's efficacy was tested in eight study cases, using Dose‐Volume Histograms (DVHs), spot selection efficiency, and computation time analysis for benchmarking against established methods.ResultsThe proposed method showed superior performance in DVH quality, adhering to LB constraints while maintaining high‐quality treatment plans. It outperformed existing techniques in spot selection, reducing unnecessary spots and balancing precision with efficiency. Cases studies confirmed the method's effectiveness in producing clinically feasible plans with enhanced dose distributions and reduced hotspots, especially in cases with elevated LB constraints.ConclusionsOur Two‐Stage MILP strategy signifies a significant advancement in IMPT treatment planning. By incorporating LB constraints directly into the optimization process, it achieves superior plan quality and deliverability compared to current methods. This approach is particularly advantageous in clinical settings requiring minimum spot number and high MU LB constraints, offering the potential for improved patient outcomes through more precise and efficient radiation therapy plans.
A phase 2 trial of ADT interruption in patients responding exceptionally to AR-pathway inhibitor in metastatic hormone-sensitive prostate cancer (A-DREAM/Alliance A032101).
TPS5118 Background: Novel androgen receptor pathway inhibitors (ARPIs) improve overall survival (OS) in patients (pts) with metastatic hormone-sensitive prostate cancer (mHSPC) in conjunction with testosterone suppression (TS) relative to TS alone. However, the duration of treatment required to derive clinical benefit is unclear, as is whether continuous treatment is requisite for optimal cancer outcomes. Favorable PSA declines have been associated with prolonged OS in clinical trials testing TS + ARPIs. We thus designed this single-arm Phase 2 trial to test the hypothesis that pts who achieve exceptional response to upfront TS + ARPI can suspend treatment, allowing for T recovery and improvement in quality of life while maintaining favorable clinical outcomes. Methods: Eligible pts had mHSPC by conventional imaging with PSA ≥ 5 ng/ml and T ≥ 150 ng/dl (or not known to have been hypogonadal) prior to starting treatment, have been receiving TS for 540-750 days and ARPI for ≥ 360 days, and have achieved PSA < 0.2 ng/ml (stable or falling for 3 consecutive measurements) with castrate T <50 ng/dl at the time of enrollment. Intermittent ADT for biochemical recurrence prior to mHSPC diagnosis, prior local therapy, prior radiation to metastatic sites, and up to 6 cycles of docetaxel in mHSPC are permitted. Pts who underwent surgical castration, received ARPI prior to mHSPC diagnosis, or are receiving experimental treatment for mHSPC or participating in a clinical trial that does not allow for TS or ARPI interruption are excluded. After enrollment, pts discontinue both TS and ARPI and are followed with PSA and T levels every 3 months, conventional CT/MRI and bone scan at least every 6 months, and FACT-P questionnaire for patient-reported outcomes every 6 months. Treatment re-initiation triggers are PSA increase to ≥ 5 ng/ml, radiographic change (progressive disease per modified RECIST 1.1 on CT/MRI or unconfirmed progressive disease per PCWG3 on bone scan), or symptoms attributable to prostate cancer. Subsequent management is per physician discretion. The primary endpoint is remaining treatment-free with eugonadal T (> 150 mg/dl) 18 months after the start of treatment interruption, with 75 pts to be enrolled to differentiate 18-month treatment free rates of 0.30 (null hypothesis) and 0.45 (alternative hypothesis). Secondary endpoints include time to eugonadal T, duration off treatment, and changes in patient-reported outcomes. Exploratory endpoints include radiographic progression-free survival, time to next treatment, OS, and correlation of tissue- and blood-based biomarkers with clinical endpoints. The study was activated in July 2022 and accrual is ongoing throughout the NCTN. Support: U10CA180821, U10CA180882, UG1CA189823, https://acknowledgments.alliancefound.org , Veracyte Inc. Clinical trial information: NCT05241860 .
Final results of a phase I/II dose-escalation study of fractionated dose 177Lu-PSMA-617 for progressive metastatic castration resistant prostate cancer (mCRPC).
5074 Background: PC commonly expresses PSMA and has dose-responsive radiosensitivity. 177Lu-based radioligands usually use an empiric dosing regimen. This 1st dose-escalation study of 177Lu-PSMA-617 employed a dose-dense fractionation schedule intended to allow delivery of higher total doses to overcome radioresistance due to repopulation. Here, we report mature results of the study. Methods: Progressive mCRPC following > 1 potent ARPI (e.g., abi/enza) and chemo (or unfit/refuse taxane) without limit of # prior therapies provided adequate organ function and ECOG PS 0-2. Treatment: single cycle of fractionated dose 177Lu-PSMA-617 on D1 and D15. In Ph I dose-escalation, patients (pts) received one cycle of 7.4 - 22 GBq followed by Simon 2-stage Ph II at 22.2 GBq. PSMA expression was not required for treatment, but pre- and post-treatment 68Ga-PSMA11 PET/CT and/or 177Lu-PSMA-617 SPECT done. Primary efficacy by PSA changes with 2ndary outcomes with CT/bone scans, PSMA PET, circulating tumor cell (CTC; CellSearch) counts, plasma DNA (PCF_SELECT), and survival. Results: Between 1/2017 – 2/2021, 50 pts treated with median PSA 164.3, 35 (70%) CALGB (Halabi) poor risk. 47 (94%) bone, 38 (76%) nodal, 12 (24%) lung, 5 (10%) liver mets (4 additional pts with PSMA PET+ liver mets not apparent on CT). 29 (58%) with prior >2 ARPI, 29 (58%) with >1 chemo, 14 (28%) with Ra-223, 2 (4%) with 177Lu-J591. 27 (54%) treated at 22 GBq. No dose-limiting toxicity during Ph I. 38 (76%) with any PSA decline, 27 (54%) with >50% PSA. Median rPFS 8.3 mo [5.6-16.7], and OS 15.7 mo [10.9-20.6]. Of 17 RECIST measurable, 6 (35.3%) responded, 7 (41.2%) stable, 4 (23.5%) progressed. Of 31 with paired CTC counts, 16 (52%) decreased, 5 (16%) were stable; 10 (32.3%) converted to favorable/undetectable. Plasma DNA with high allele-specific ploidy and ARcopy number gain associated with OS (univariate). Treatment emergent adverse events (TEAE): 32 (64%) dry mouth, 22 (44%) pain flare, 22 (44%) fatigue, 19 (38%) nausea, 15 (30%) anemia, 15 (28%) thrombocytopenia (plts), 9 (18%) neutropenia (ANC). All TEAEs restricted to grade (Gr) 1-2 except 6 (12%) with Gr 3 anemia, 2 (4%) Gr 3/4 plts, 1 (2%) Gr 3 ANC. TEAE incidence and Gr were not related to dose. On multivariable analysis, 177Lu dose administered (p=0.09), CALGB risk (p=0.04), prior chemo (p=0.009), associated with OS; dose (p=0.1), CALGB risk (p=0.2), and AR copy number (p=0.2) associated with PSA50 decline. Baseline PSMA imaging (by imaging score or SUVmax) was not associated with OS or response. Conclusions: A single-cycle of fractionated-dose 177Lu-PSMA-617 is safe. Despite no pre-selection for PSMA expression, most had PSA decline with favorable PFS and OS compared to historical controls and similar to PSMA-selected targeted radionuclide studies administering multiple cycles in a less dose-intense approach. Clinical trial information: NCT03042468 .
Impact of Relative Biologic Effectiveness for Proton Therapy for Head and Neck and Skull-Base Tumors: A Technical and Clinical Review
Proton therapy has emerged as a crucial tool in the treatment of head and neck and skull-base cancers, offering advantages over photon therapy in terms of decreasing integral dose and reducing acute and late toxicities, such as dysgeusia, feeding tube dependence, xerostomia, secondary malignancies, and neurocognitive dysfunction. Despite its benefits in dose distribution and biological effectiveness, the application of proton therapy is challenged by uncertainties in its relative biological effectiveness (RBE). Overcoming the challenges related to RBE is key to fully realizing proton therapy’s potential, which extends beyond its physical dosimetric properties when compared with photon-based therapies. In this paper, we discuss the clinical significance of RBE within treatment volumes and adjacent serial organs at risk in the management of head and neck and skull-base tumors. We review proton RBE uncertainties and its modeling and explore clinical outcomes. Additionally, we highlight technological advancements and innovations in plan optimization and treatment delivery, including linear energy transfer/RBE optimizations and the development of spot-scanning proton arc therapy. These advancements show promise in harnessing the full capabilities of proton therapy from an academic standpoint, further technological innovations and clinical outcome studies, however, are needed for their integration into routine clinical practice.