AbstractMSCs are known as multipotent mesenchymal stem cells that have been found capable of differentiating into various lineages including cartilage. However, recent studies suggest MSCs are pericytes that stimulate tissue repair through trophic signaling. Aimed at articular cartilage repair in a one-stage cell transplantation, this study provides first clinical evidence that MSCs stimulate autologous cartilage repair in the knee without engrafting in the host tissue. A phase I (first-in-man) clinical trial studied the one-stage application of allogeneic MSCs mixed with 10% or 20% recycled defect derived autologous chondrons for the treatment of cartilage defects in 35 patients. No treatment-related serious adverse events were found and statistically significant improvement in clinical outcome shown. Magnetic resonance imaging and second-look arthroscopies showed consistent newly formed cartilage tissue. A biopsy taken from the center of the repair tissue was found to have hyaline-like features with a high concentration of proteoglycans and type II collagen. DNA short tandem repeat analysis delivered unique proof that the regenerated tissue contained patient-DNA only. These findings support the hypothesis that allogeneic MSCs stimulate a regenerative host response. This first-in-man trial supports a paradigm shift in which MSCs are applied as augmentations or “signaling cells” rather than differentiating stem cells and opens doors for other applications.
Effects of primary and recurrent sacral chordoma on the motor and nociceptive function of hindlimbs in rats: an orthotopic spine model
OBJECTIVEChordoma is a slow-growing, locally aggressive cancer that is minimally responsive to conventional chemotherapy and radiotherapy and has high local recurrence rates after resection. Currently, there are no rodent models of spinal chordoma. In the present study, the authors sought to develop and characterize an orthotopic model of human chordoma in an immunocompromised rat.METHODSThirty-four immunocompromised rats were randomly allocated to 4 study groups; 22 of the 34 rats were engrafted in the lumbar spine with human chordoma. The groups were as follows: UCH1 tumor–engrafted (n = 11), JHC7 tumor–engrafted (n = 11), sham surgery (n = 6), and intact control (n = 6) rats. Neurological impairment of rats due to tumor growth was evaluated using open field and locomotion gait analysis; pain response was evaluated using mechanical or thermal paw stimulation. Cone beam CT (CBCT), MRI, and nanoScan PET/CT were performed to evaluate bony changes due to tumor growth. On Day 550, rats were killed and spines were processed for H & E–based histological examination and immunohistochemistry for brachyury, S100β, and cytokeratin.RESULTSThe spine tumors displayed typical chordoma morphology, that is, physaliferous cells filled with vacuolated cytoplasm of mucoid matrix. Brachyury immunoreactivity was confirmed by immunostaining, in which samples from tumor-engrafted rats showed a strong nuclear signal. Sclerotic lesions in the vertebral body of rats in the UCH1 and JHC7 groups were observed on CBCT. Tumor growth was confirmed using contrast-enhanced MRI. In UCH1 rats, large tumors were observed growing from the vertebral body. JHC7 chordoma–engrafted rats showed smaller tumors confined to the bone periphery compared with UCH1 chordoma–engrafted rats. Locomotion analysis showed a disruption in the normal gait pattern, with an increase in the step length and duration of the gait in tumor-engrafted rats. The distance traveled and the speed of rats in the open field test was significantly reduced in the UCH1 and JHC7 tumor–engrafted rats compared with controls. Nociceptive response to a mechanical stimulus showed a significant (p < 0.001) increase in the paw withdrawal threshold (mechanical hypalgesia). In contrast, the paw withdrawal response to a thermal stimulus decreased significantly (p < 0.05) in tumor-engrafted rats.CONCLUSIONSThe authors developed an orthotopic human chordoma model in rats. Rats were followed for 550 days using imaging techniques, including MRI, CBCT, and nanoScan PET/CT, to evaluate lesion progression and bony integrity. Nociceptive evaluations and locomotion analysis were performed during follow-up. This model reproduces cardinal signs, such as locomotor and sensory deficits, similar to those observed clinically in human patients. To the authors’ knowledge, this is the first spine rodent model of human chordoma. Its use and further study will be essential for pathophysiology research and the development of new therapeutic strategies.
Analysis of Postoperative Venous Thromboembolism in Patients With Chronic Ulcerative Colitis: Is It the Disease or the Operation?
BACKGROUND: Patients with IBD have a higher baseline risk of venous thromboembolism, which further increases with surgery. Therefore, extended venous thromboembolism chemoprophylaxis has been suggested in certain high-risk cohorts. OBJECTIVE: The purpose of this study was to determine whether the underlying diagnosis, operative procedure, or both influence the incidence of postoperative venous thromboembolism. DESIGN: This was a retrospective review. SETTINGS: The American College of Surgeons–National Surgical Quality Improvement Project database was analyzed. PATIENTS: The NSQIP database was queried for patients with chronic ulcerative colitis and non-IBD undergoing colorectal resections using surgical Current Procedural Terminology codes modeled after the 3 stages used for the surgical management of chronic ulcerative colitis from 2005 to 2013. MAIN OUTCOME MEASURES: We measured 30-day postoperative venous thromboembolism risk in patients with chronic ulcerative colitis based on operative stage and risk factors for development of venous thromboembolism. RESULTS: A total of 18,833 patients met inclusion criteria, with an overall rate of venous thromboembolism of 3.8. Among procedure risk groups, venous thromboembolism rates were high risk, 4.4%; intermediate risk, 1.6%; and low risk, 0.7% (across risk groups, p < 0.01). Emergent case subjects exhibited a higher rate of venous thromboembolism than their elective counterparts (6.9% vs 3.1%). Factors significantly associated with venous thromboembolism on adjusted analysis included emergent risk case (adjusted OR = 7.85), high-risk elective case (adjusted OR = 5.07), intermediate-risk elective case (adjusted OR = 2.69), steroid use (adjusted OR = 1.54), and preoperative albumin <3.5 g/dL (adjusted OR = 1.45). LIMITATIONS: Because of its retrospective nature, correlation between procedures and venous thromboembolism risk can be demonstrated, but causation cannot be proven. In addition, data on inpatient and extended venous thromboembolism prophylaxis use are not available. CONCLUSIONS: Emergent status and operative procedure are the 2 highest risk factors for postoperative venous thromboembolism. Extended venous thromboembolism prophylaxis might be appropriate for patients undergoing these high-risk procedures or any emergent colorectal procedures. See Video Abstract at http://links.lww.com/DCR/A339.
Performance characterization of a 3D liquid scintillation detector for discrete spot scanning proton beam systems
Abstract Existing systems for proton beam dosimetry are limited in their ability to provide a complete, accurate, and detailed account of volumetric dose distribution. In this work, we describe the design and development of a portable, fast, and reusable liquid scintillator-based three-dimensional (3D) optical detection system for use in proton therapy. Our long-term goal is to use this system clinically for beam characterization, dosimetry, and quality assurance studies of discrete spot scanning proton beam systems. The system used a 20 × 20 × 20 cm 3 liquid scintillator volume. Three mutually orthogonal cameras surrounding this volume captured scintillation photons emitted in response to the proton beams. The cameras exhibited a mean spatial resolution of 0.21 mm over the complete detection volume and a temporal resolution of 11 ms. The system is shown to be capable of capturing all 94 beam energies delivered by a synchrotron and performing rapid beam range measurements with a mean accuracy of 0.073 ± 0.030 mm over all energies. The range measurement uncertainty for doses less than 1 cGy was found to be ±0.355 mm, indicating high precision for low dose detection. Finally, we demonstrated that using multiple cameras allowed for the precise locations of the delivered beams to be tracked in 3D. We conclude that this detector is capable of real-time and accurate tracking of dynamic spot beam deliveries in 3D. The high-resolution light profiles it generates will be useful for future 3D construction of dose maps.
Breast cysts rapidly enlarging with replacement of breast parenchyma and asymmetry
Intraoperative Infusion of Dexmedetomidine for Prevention of Postoperative Delirium and Cognitive Dysfunction in Elderly Patients Undergoing Major Elective Noncardiac Surgery
Insertion of tympanostomy tubes is a common elective pediatric surgical procedure and is typically performed under general anesthesia. The potential to reduce general anesthetic requirements for young children has led to increased interest in alternatives for tympanostomy tube placement. A tympanostomy tube system, developed to enable tympanostomy tube placement in a single pass on conscious patients under moderate sedation, was evaluated. A prospective study on 128 children and 253 tympanostomy tube placements conducted at 4 centers in the United States demonstrated an 88.3% success rate in performing the procedure under moderate sedation with adverse events within normal rates reported in the literature. The feasibility of completing tympanostomy tube placement under moderate sedation enables avoidance of general anesthesia and provides additional choices to physicians and parents.
Does Provider Self‐Reporting of Etiquette Behaviors Improve Patient Experience? A Randomized Controlled Trial
BACKGROUNDThere is a glaring lack of published evidence‐based strategies to improve the Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) patient experience scores on the physician domain. Strategies that have been used are resource intensive and difficult to sustain.OBJECTIVEWe hypothesized that prompting providers to assess their own etiquette‐based practices every 2 weeks over the course of 1 year would improve patient experience on the physician domain.DESIGNRandomized controlled trial.SETTING4 acute care hospitals.PARTICIPANTSHospitalists.INTERVENTIONHospitalists were randomized to the study or the control arm. The study arm was prompted every 2 weeks for 12 months to report how frequently they engaged in 7 best‐practice bedside etiquette behaviors. Control arm participants received similarly worded questions on quality improvement behaviors.MEASUREMENTProvider experience scores were calculated from the physician HCAHPS and Press Ganey survey provider items.RESULTSPhysicians reported high rates of etiquette‐based behavior at baseline, and this changed modestly over the study period. Self‐reported etiquette behaviors were not associated with experience scores. The difference in difference analysis of the baseline and postintervention physician experience scores between the intervention arm and the control arm was not statistically significant (P = 0.71).CONCLUSIONIn this 12‐month study, biweekly reflection and reporting of best‐practice bedside etiquette behaviors did not result in significant improvement on physician domain experience scores. It is likely that hospitalists' self‐assessment of their bedside etiquette may not reflect patient perception of these behaviors. Furthermore, hospitalists may be resistant to improvement in this area since they rate themselves highly at baseline.
Impact of perioperative anticoagulation on artificial urinary sphincter device survival