Citations

Clear

6273 citation(s) found for "To, Andrew".

Delta screw versus RetroScrew tibial fixation for ACL reconstruction
Rhee, Peter C. , Dahm, Diane L., Thoreson, Andrew R. , An, Kai‐Nan , Levy, Bruce A. , Stuart, Michael J.

Mayo Clinic

Knee Surgery, Sports Traumatology, Arthroscopy | May 17, 2011 | Volume: 19 | Issue: S1 | Pages: 94-100

10.1007/s00167-011-1543-8 | PMID 22080349 Get It

AbstractPurposeThe purpose of this study is to determine whether the RetroScrew tibial fixation system offers a biomechanical advantage over the Delta screw for anterior cruciate ligament (ACL) reconstruction in cadaveric tibias with low bone mineral density (BMD).MethodsTen matched pairs of osteoporotic cadaveric tibiae underwent simulated ACL reconstruction using quadrupled hamstring grafts with one of the two tibial fixation constructs. Group 1 was fixed with the Delta screw (DS; 35‐mm antegrade biointerference screw), and group 2 was fixed with the RetroScrew system (RSS; 20‐mm retrograde and 17‐mm antegrade biointerference screws). Each construct was cyclically loaded (50–200 N, 1 Hz, 500 cycles) and subsequently loaded to failure (20 mm/s).ResultsAll specimens were osteoporotic without significant segmental (proximal, middle, and distal) BMD differences between groups by quantitative computed tomography (P = n.s.). A trend was noted for more construct failures due to graft slippage in the DS group (n = 3) over the RSS group (n = 1). There were no significant differences in cyclic displacement (P = n.s.), maximum cyclic stiffness (P = n.s.), maximum load at failure (P = n.s.), or pullout stiffness (P = n.s.) between groups.ConclusionsIn an osteoporotic cadaveric model, there was no significant biomechanical advantage of the RetroScrew system versus the Delta screw for tibial fixation in soft tissue graft ACL reconstruction. However, a trend toward lower graft fixation failure to cyclic loading was noted with the RetroScrew system.Level of evidenceBiomechanical comparative study, Level II.
Re: Ultrasound Estimated Bladder Weight and Measurement of Bladder Wall Thickness—Useful Noninvasive Methods for Assessing the Lower Urinary Tract?
Jacobson, Debra J., Sauver, Jennifer L. St. , Jacobsen, Steven J. , Rule, Andrew D. , St Sauver, Jennifer L

Mayo Clinic

Journal of Urology | April 24, 2011 | Volume: 185 | Issue: 6 | Pages: 2435-2435

10.1016/j.juro.2011.02.031 | PMID 21513957 Get It

Intracranial Fibromatosis
Mitchell, Andrew , Scheithauer, Bernd W., Ebersold, Michael J., Forbes, Glenn S.

Mayo Clinic

Neurosurgery | April 23, 2011 | Volume: 29 | Issue: 1 | Pages: 123-126

10.1227/00006123-199107000-00022 Get It

Abstract Fibromatoses are uncommon infiltrative lesions affecting musculoaponeurotic structures, most often of the limbs and trunk. Lesions involving the cranial cavity are rare and require the same aggressive surgical management as elsewhere in the body. This case illustrates their clinical and neuroradiological features and underscores the necessity for aggressive resection to avoid recurrence. The literature is reviewed. (Neurosurgery 29:123-126, 1991)
Acrocyanosis: The Flying Dutchman
Kurklinsky, Andrew K., Miller, Virginia M. , Rooke, Thom W.

Mayo Clinic

Vascular Medicine | March 22, 2011 | Volume: 16 | Issue: 4 | Pages: 288-301

10.1177/1358863x11398519 | PMID 21427140 Get It

Acrocyanosis is symmetric, painless, discoloration of different shades of blue in the distal parts of the body that is marked by symmetry, relative persistence of the skin color changes with aggravation by cold exposure, and frequent association with local hyperhidrosis of hands and feet. Described over a century ago and despite seeming familiarity, it remains a poorly understood condition that shares much in clinical presentation with other conditions characterized by skin color changes in the distal parts of the body. The diagnosis remains mostly clinical, and pathological mechanisms vary suggesting that acrocyanosis may not be a single entity. We performed an extensive literature review to summarize existing knowledge about the demographics, pathology, diagnosis, and treatment of this condition.
CSF complements serum for evaluating paraneoplastic antibodies and NMO-IgG
McKeon, Andrew , Pittock, Sean J. , Lennon, Vanda A. , Pittock, S J , McKeon, Andrew

Mayo Clinic

Neurology | March 21, 2011 | Volume: 76 | Issue: 12 | Pages: 1108-1110

10.1212/wnl.0b013e318211c379 | PMID 21422462 Get It

CD40 Pathway Activation Status Predicts Response to CD40 Therapy in Diffuse Large B Cell Lymphoma
Burington, Bart, Peng, Yue , Shi, Xiaoyan , Advani, Ranjana H. , Lau, Jeffrey , Stinson, Susanna, Stinson, Jeremy, Januario, Thomas, Vos, Sven de , Ansell, Stephen M. , Forero‐Torres, Andres , Fedorowicz, Grazyna, Yang, Teddy , Elkins, Kristi , Du, Changchun, Mohan, Sankar, Modrušan, Zora , Seshagiri, Somasekar , Yu, Shang‐Fan , Pandita, Ajay , Koeppen, Hartmut , French, Dorothy, Polson, Andrew G. , Offringa, Rienk , Whiting, Nancy, Ebens, Allen , Dornan, David, Tan, Jenille , Yu, Nancy , Advani, Ranjana H , Modrusan, Zora

Mayo Clinic

Science Translational Medicine | March 16, 2011 | Volume: 3 | Issue: 74 | Pages: No page available

10.1126/scitranslmed.3001620 | PMID 21411738 Get It

A 15-gene expression signature predicts whether a patient with diffuse large B cell lymphoma will respond to dacetuzumab, a therapeutic antibody.
Recurrent syncope as a manifestation of a dopamine-secreting glomus vagale tumor
Benarroch, Eduardo E. , McKeon, Andrew , McKeon, Andrew

Mayo Clinic

Neurology | March 15, 2011 | Volume: 76 | Issue: 11 | Pages: 1021-1022

10.1212/wnl.0b013e31821043e3 | PMID 21403114 Get It

Transverse connectors providing increased stability to the cervical spine rod-screw construct: an in vitro human cadaveric study
Shaw, Miranda N., Morel, É., UTTER, PHILLIP ANDREW, Gussous, Yazeed M., Ginoux, Lise, Berglund, Lawrence J., Gay, Ralph E. , Krauss, William E.

Mayo Clinic

Journal of Neurosurgery: Spine | March 11, 2011 | Volume: 14 | Issue: 6 | Pages: 719-725

10.3171/2011.1.spine10411 | PMID 21395395 Get It

Object The object of this study was to determine if the addition of transverse connectors (TCs) to a rod-screw construct leads to increased stabilization of the cervical spine. Methods Eleven human cadaveric cervical spines (C2–T1) were used to examine the effect of adding connectors to a C3–7 rod-screw construct in 3 models of instability: 1) C3–6 wide laminectomy, 2) wide laminectomy and 50% foraminotomy at C4–5 and C5–6, and 3) wide laminectomy with full medial to lateral foraminotomy. Following each destabilization procedure, specimens were tested with no TC, 1 TC between the C-5 screws, and 2 TCs between the C-4 and C-6 screws. Testing of the connectors was conducted in random order. Specimens were subjected to ± 2 Nm of torque in flexion and extension, lateral bending, and axial rotation. Range of motion was determined for each experimental condition. Statistical comparisons were made between the destabilized and intact conditions, and between the addition of TCs and the absence of TCs. Results The progressive destabilization procedures significantly increased motion. The addition of TCs did not significantly change motion in flexion and extension. Lateral bending was significantly decreased with 2 connectors, but not with 1 connector. The greatest effect was on axial rotation. In general, 2 TCs were more restrictive than 1 TC, and decreased motion 10% more than fixation alone. Conclusions Regardless of the degree of cervical destabilization, 1 or 2 TCs decreased motion compared with rods and screws alone. Axial rotation was most affected. Transverse connectors effectively increase the rigidity of rod-screw constructs in the cervical spine. Severe cervical instability can be overcome with the use of 2 TCs, but in cases in which 2 cannot be used, 1 should be adequate and superior to none.
Importance of Each Residue within Secretin for Receptor Binding and Biological Activity
Dong, Maoqing , Le, Angela, Te, Jerez A., Pinon, Delia I., Bordner, Andrew J., Miller, Laurence J.

Mayo Clinic

Biochemistry | March 9, 2011 | Volume: 50 | Issue: 14 | Pages: 2983-2993

10.1021/bi200133u | PMID 21388146 Get It

Neurohospitalists Reduce Length of Stay for Patients With Ischemic Stroke
Dawson, Sophie , Raper, Carol C., Thiemann, Kay, Josephson, S. Andrew , Barrett, Kevin M. , Freeman, William D. , Thiemann, Kay M.B.

Mayo Clinic

The Neurohospitalist | March 4, 2011 | Volume: 1 | Issue: 2 | Pages: 67-70

10.1177/1941875210394202 | PMID 23983839 Get It

Background: Neurohospitalists may improve the efficiency and quality of care delivered to hospitalized patients with neurological disease. However, there is limited systematic data to support this hypothesis. The primary purpose of this study was to compare length of stay (LOS) for patients with ischemic stroke cared for by either neurohospitalists or community-based neurologists at a single institution. Methods: A retrospective chart review was performed for all patients with ischemic stroke discharged from St. Luke’s Hospital in Jacksonville, Florida, between January 2006 and December 2007. The LOS for patients cared for by neurohospitalists was compared to the LOS for patients cared for by community neurologists. Compliance with Joint Commission inpatient stroke quality metrics was also compared. Results: A total of 533 patients were discharged with a principal diagnosis of ischemic stroke over the 24-month study period. Neurohospitalists cared for 313 patients with mean (± SD) LOS of 4.9 (5.2) days (95% CI: 4.3-5.5 days), and community-based neurologists cared for 220 patients with a mean LOS of 6.5 (8.2) days (95% CI: 5.4-7.6 days). The mean LOS was significantly less for the neurohospitalists compared to the community-based neurologists ( P = .005). Neurohospitalists achieved a higher compliance rate in 10 of 11 inpatient stroke quality metrics and achieved significantly higher compliance rate of smoking cessation education ( P = .019). Conclusions: Neurohospitalists achieved significantly shorter LOS for patients with ischemic stroke compared to community-based neurologists. These data suggest that neurohospitalists can also improve compliance with quality metrics necessary for Joint Commission Primary Stroke Center designation.