Citations

Clear

7737 citation(s) found for "Ma, Daniel".

A rapid and reliable chromosome analysis method for products of conception using interphase nuclei
Babu, Ramesh , Dyke, Daniel L. Van , Bhattacharya, Saurabh Kumar , Dev, Vaithilingam G., Liu, Mingya, Kwon, Minjae, Gu, Guangyu , Koduru, Prasad , Rao, Nagesh, Williamson, Cynthia M., Fuentes, Sarah, Papa, Stephen, Kopuri, Srikanthi, Lal, Vandana , Van Dyke, Daniel L, Williamson, Cynthia, Fuentes, Ernesto J.

Mayo Clinic

Molecular Genetics & Genomic Medicine | March 24, 2018 | Volume: 6 | Issue: 3 | Pages: 370-381

10.1002/mgg3.381 | PMID 29573570 Get It

AbstractBackgroundKaryotype determination has a central role in the genetic workup of pregnancy loss, as aneuploidy (trisomy and monosomy) and polyploidy (triploidy and tetraploidy) are the cause in at least 50% of first trimester, 25% of second trimester, and 11% of third trimester miscarriages. There are several limitations with the current approaches of obtaining a karyotype using traditional cytogenetics, fluorescence in situ hybridization with a limited number of probes, and chromosomal microarray. These include culture failure, incomplete results, lower sensitivity, and longer reporting time.MethodsTo overcome current limitations, a novel molecular assay is developed with a Standard Resolution Interphase Chromosome Profiling probe set which is a variation of the recently developed High Resolution probe set. It generates a molecular karyotype that can detect all major changes commonly associated with pregnancy loss. Initial familiarization of signal patterns from the probe set was used, followed by validation of the method using 83 samples from miscarriages in a blind study from three different laboratories. Finally, the clinical utility of the method was tested on 291 clinical samples in two commercial reference laboratory settings on two different continents.ResultsThe new molecular approach not only identified all the chromosome changes observed by current methods, but also significantly improved abnormality detection by characterizing derivative chromosomes and finding subtle subtelomeric rearrangements, balanced and unbalanced. All Robertsonian translocations were also detected. The abnormality rate was 54% on clinical samples from commercial laboratory 1 and 63% from laboratory 2.ConclusionThe attributes of this method make it an ideal choice for the genetic workup of miscarriages, namely (1) near 100% successful results, (2) greater sensitivity than conventional chromosome analysis or FISH panels, (3) rapid reporting time, and (4) favorable comparisons with chromosomal microarray.
Ossabaw Pigs With a PCSK9 Gain‐of‐Function Mutation Develop Accelerated Coronary Atherosclerotic Lesions: A Novel Model for Preclinical Studies
Yuan, Fang , Guo, Liang , Park, Kyoung‐Ha , Woollard, John R. , Kwon, Taek‐Geun , Melkamu, Tamene, Zang, Bin , Fahrenkrug, Scott C. , Kolodgie, Frank D. , Lerman, Lilach O. , Carlson, Daniel F. , Jiang, Kai , Jiang, Kai , Smith, Samantha Louise , Lerman, Amir , Virmani, Renu

Mayo Clinic

Journal of the American Heart Association | March 23, 2018 | Volume: 7 | Issue: 6 | Pages: No page available

10.1161/jaha.117.006207 | PMID 29572319 Get It

Background Ossabaw pigs are unique miniature swine with genetic predisposition to develop metabolic syndrome and coronary atherosclerosis after extended periods receiving atherogenic diets. We have hypothesized that transgenic Ossabaw swine expressing chimp PCSK9 (proprotein convertase subtilisin‐like/kexin type 9) containing the D374Y gain of function would develop familial hypercholesterolemia and coronary artery plaques more rapidly than Landrace swine with the same transgene. Methods and Results Ossabaw and Landrace PCSK9 gain‐of‐function founders were generated by Sleeping Beauty transposition and cloning. Histopathologic findings in the Ossabaw founder animal showed more advanced plaques and higher stenosis than in the Landrace founder, underscoring the Ossabaw genetic predisposition to atherosclerosis. We chose to further characterize the Ossabaw PCSK9 gain‐of‐function animals receiving standard or atherogenic diets in a 6‐month longitudinal study using computed tomography, magnetic resonance (MR) imaging, intravascular ultrasound, and optical coherence tomography, followed by pathological analysis of atherosclerosis focused on the coronary arteries. The Ossabaw model was consistently hypercholesterolemic, with or without dietary challenge, and by 6 months had consistent and diffuse fibrofatty or fibroatheromatous plaques with necrosis, overlying fibrous caps, and calcification in up to 10% of coronary plaques. Conclusions The Ossabaw PCSK9 gain‐of‐function model provides consistent and robust disease development in a time frame that is practical for use in preclinical therapeutic evaluation to drive innovation. Although no animal model perfectly mimics the human condition, this genetic large‐animal model is a novel tool for testing therapeutic interventions in the context of developing and advanced coronary artery disease.
Matrix-Applied Characterized Autologous Cultured Chondrocytes Versus Microfracture: Five-Year Follow-up of a Prospective Randomized Trial
Recker, David P., Ilgenfritz, John, Saris, Daniël B.F. , Group, on behalf of the SUMMIT Extension Study, Brittberg, Mats , Group, on behalf of the SUMMIT Extension Study

Mayo Clinic

The American Journal of Sports Medicine | March 22, 2018 | Volume: 46 | Issue: 6 | Pages: 1343-1351

10.1177/0363546518756976 | PMID 29565642 Get It

Background: Matrix-based cell therapy improves surgical handling, increases patient comfort, and allows for expanded indications with better reliability within the knee joint. Five-year efficacy and safety of autologous cultured chondrocytes on porcine collagen membrane (MACI) versus microfracture for treating cartilage defects have not yet been reported from any randomized controlled clinical trial. Purpose: To examine the clinical efficacy and safety results at 5 years after treatment with MACI and compare these with the efficacy and safety of microfracture treatment for symptomatic cartilage defects of the knee. Study Design: Randomized controlled trial; Level of evidence, 1. Methods: This article describes the 5-year follow-up of the SUMMIT (Superiority of MACI Implant Versus Microfracture Treatment) clinical trial conducted at 14 study sites in Europe. All 144 patients who participated in SUMMIT were eligible to enroll; analyses of the 5-year data were performed with data from patients who signed informed consent and continued in the Extension study. Results: Of the 144 patients randomized in the SUMMIT trial, 128 signed informed consent and continued observation in the Extension study: 65 MACI (90.3%) and 63 microfracture (87.5%). The improvements in Knee injury and Osteoarthritis Outcome Score (KOOS) Pain and Function domains previously described were maintained over the 5-year follow-up. Five years after treatment, the improvement in MACI over microfracture in the co-primary endpoint of KOOS pain and function was maintained and was clinically and statistically significant ( P = .022). Improvements in activities of daily living remained statistically significantly better ( P = .007) in MACI patients, with quality of life and other symptoms remaining numerically higher in MACI patients but losing statistical significance relative to the results of the SUMMIT 2-year analysis. Magnetic resonance imaging (MRI) evaluation of structural repair was performed in 120 patients at year 5. As in the 2-year SUMMIT (MACI00206) results, the MRI evaluation showed improvement in defect filling for both treatments; however, no statistically significant differences were noted between treatment groups. Conclusion: Symptomatic cartilage knee defects 3 cm 2 or larger treated with MACI were clinically and statistically significantly improved at 5 years compared with microfracture treatment. No remarkable adverse events or safety issues were noted in this heterogeneous patient population.
Networking Matters: A Social Network Analysis of the Association of Program Directors of Internal Medicine
Warm, Eric J. , Arora, Vineet M. , Chaudhry, Saima , Halvorsen, Andrew J. , Schauer, Daniel P. , Thomas, Kris G., McDonald, Furman S., Warm, Eric , Halvorsen, Andrew, Thomas, Kris

Mayo Clinic

Teaching and Learning in Medicine | March 22, 2018 | Volume: 30 | Issue: 4 | Pages: 415-422

10.1080/10401334.2018.1441715 | PMID 29565686 Get It

Cerebrospinal fluid chitinase-3-like protein 1 level is not an independent predictive factor for the risk of clinical conversion in radiologically isolated syndrome
Thouvenot, Éric , Hinsinger, Geoffrey, Dematteï, Christophe , Uygunoğlu, Uğur , Castelnovo, Giovanni, Pittion‐Vouyovitch, S., Okuda, Darin T. , Kantarci, Orhun H. , Pelletier, Daniel , Lehmann, Sylvain , Marin, Philippe , Sıva, Aksel , Lebrun‐Frénay, Christine , Lebrun‐Frénay, Christine , Siva, Aksel , Thouvenot, Eric , Okuda, Darin T , Lehmann, Sylvain

Mayo Clinic

Multiple Sclerosis Journal | March 22, 2018 | Volume: 25 | Issue: 5 | Pages: 669-677

10.1177/1352458518767043 | PMID 29564952 Get It

Background: Younger age, male sex and presence of spinal cord lesion(s) increase the risk of conversion from radiologically isolated syndrome (RIS) to relapsing-remitting multiple sclerosis (RRMS). Elevated cerebrospinal fluid (CSF) chitinase-3-like protein 1 (CHI3L1) levels predict conversion from clinically isolated syndrome (CIS) to RRMS. Objective: To evaluate the prognostic value of CSF CHI3L1 in RIS patients for conversion to RRMS. Methods: We compared CSF CHI3L1 concentrations in RIS, CIS, RRMS and symptomatic controls (SCs). We analysed the influence of epidemiological, radiological and CSF parameters on the risk of clinical event. Results: A total of 211 patients (71 RIS, 48 CIS, 50 RRMS and 42 SC) were included. CSF CHI3L1 levels were lower in RIS than in RRMS and higher in RIS with positive CSF versus negative CSF and SC. The presence of at least one spinal cord lesion was the only independent predictor of faster conversion to RRMS. Association of high CSF CHI3L1 levels, positive CSF (presence of oligoclonal bands and/or an elevated IgG index) or four Barkhof criteria with any spinal cord lesion showed a tendency for reduced mean conversion time. Conclusion: CSF CHI3L1 correlates with positive CSF but is not an independent predictor of the risk of conversion from RIS to RRMS.
Physical Activity and Outcomes in Patients with Stage III Colon Cancer: A Correlative Analysis of Phase III Trial NCCTG N0147 (Alliance)
Phipps, Amanda I. , Shi, Qian , Dotan, Efrat , Goldberg, Richard M. , Hardikar, Sheetal , Jahagirdar, Balkrishna, Shields, Anthony F. , Zemla, Tyler J, Limburg, Paul J. , Shi, Qian , Zemla, Tyler , Gill, Sharlene , Newcomb, Polly A. , Sinicrope, Frank A. , Sargent, Daniel J. , Alberts, Steven R.

Mayo Clinic

Cancer Epidemiology, Biomarkers & Prevention | March 21, 2018 | Volume: 27 | Issue: 6 | Pages: 696-703

10.1158/1055-9965.epi-17-0769 | PMID 29563133 Get It

AbstractBackground: Prior studies have supported an inverse association between physical activity and colon cancer risk and suggest that higher physical activity may also improve cancer survival. Among participants in a phase III adjuvant trial for stage III colon cancer, we assessed the association of physical activity around the time of cancer diagnosis with subsequent outcomes.Methods: Before treatment arm randomization (FOLFOX or FOLFOX + cetuximab), study participants completed a questionnaire including items regarding usual daily activity level and frequency of participation in recreational physical activity (N = 1,992). Using multivariable Cox models, we calculated HRs for associations of aspects of physical activity with disease-free (DFS) and overall survival (OS).Results: Over follow-up, 505 participants died and 541 experienced a recurrence. Overall, 75% of participants reported recreational physical activity at least several times a month; for participants who reported physical activity at least that often (vs. once a month or less), the HRs for DFS and OS were 0.82 [95% confidence interval (CI), 0.69–0.99] and 0.76 (95% CI, 0.63–0.93), respectively. There was no evidence of material effect modification in these associations by patient or tumor attributes, except that physical activity was more strongly inversely associated with OS in patients with stage T3 versus T4 tumors (Pinteraction = 0.03).Conclusions: These findings suggest that higher physical activity around the time of colon cancer diagnosis may be associated with more favorable colon cancer outcomes.Impact: Our findings support further research on whether colon cancer survival may be enhanced by physical activity. Cancer Epidemiol Biomarkers Prev; 27(6); 696–703. ©2018 AACR.
Effect of Postoperative Mechanical Axis Alignment on Survival and Functional Outcomes of Modern Total Knee Arthroplasties with Cement
Abdel, Matthew P. , Ollivier, Matthieu , Parratte, Sébastien , Trousdale, Robert T. , Berry, Daniel J. , Pagnano, Mark W. , Abdel, Matthew P , Berry, Daniel J

Mayo Clinic

Journal of Bone and Joint Surgery | March 21, 2018 | Volume: 100 | Issue: 6 | Pages: 472-478

10.2106/jbjs.16.01587 | PMID 29557863 Get It

Abstract: We previously compared the 15-year survivorship of total knee arthroplasty (TKA) implants that were mechanically aligned (0° ± 3° relative to the mechanical axis) compared with those that were outside that range and considered outliers. The original publication included 398 TKAs (292 in the aligned group and 106 in the outlier group) performed from 1985 to 1990. At the time of follow-up in the previous study, 138 patients (155 TKAs) had died and 59 knees had been revised. Since that publication, 49 additional patients (87 knees) have died. At 20 years, 57 (19.5%) of the 292 knees in the mechanically aligned group had been revised compared with 16 (15.1%) of the 106 knees in the outlier group (p = 0.97). Postoperative alignment within 0° ± 3° of the mechanical axis did not provide a functional advantage at 1, 5, 10, 15, and/or 20 years postoperatively as demonstrated by the Knee Society scores being similar between the groups (p ≥ 0.2 at all intervals). At 20 years, we once again did not find that neutral mechanical alignment provided better implant survivorship than that found in the outlier group. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Articular Contact Area and Pressure in Posteromedial Rotatory Instability of the Elbow
Bellato, Enrico , Kim, Young Bok , Bachman, Daniel R. , Berglund, Lawrence J., Hooke, Alexander W. , O’Driscoll, Shawn W. , Fitzsimmons, James S. , Kim, Youngbok, O'Driscoll, Shawn W., Fitzsimmons, James S

Mayo Clinic

Journal of Bone and Joint Surgery | March 21, 2018 | Volume: 100 | Issue: 6 | Pages: e34

10.2106/jbjs.16.01321 | PMID 29557868 Get It

Background: Joint incongruity in posteromedial rotatory instability (PMRI) has been theorized to determine early articular degenerative changes. Our hypothesis was that the articular contact area and contact pressure differ significantly between an intact elbow and an elbow affected by PMRI. Methods: Seven cadaveric elbows were tested under gravity varus stress using a custom-made machine designed to simulate muscle loads and allow passive elbow flexion (0° to 90°). The mean contact area and contact pressure data were collected and processed using the Tekscan sensor and software. After testing the intact specimen (intact elbow), a PMRI injury was simulated (PMRI elbow) and the specimen was tested again. Results: The PMRI elbows were characterized by initial joint subluxation and significantly elevated articular contact pressure. Both worsened, corresponding with a reduction in contact area, as the elbow was flexed from 0° until the joint subluxation and incongruity spontaneously reduced (at a mean [and standard error] of 60° ± 5° of flexion), at which point the mean contact pressure decreased from 870 ± 50 kPa (pre-reduction) to 440 ± 40 kPa (post-reduction) (p < 0.001) and the mean contact area increased from 80 ± 8 mm 2 to 150 ± 58 mm 2 (p < 0.001). This reduction of the subluxation was also followed by a shift of the contact area from the coronoid fracture edge toward the lower portion of the coronoid. At the flexion angle at which the PMRI elbows reduced, both the contact area and the contact pressure of the intact elbows differed significantly from those of the PMRI elbows, both before and after the elbow reduction (p < 0.001). Conclusions: The reduction in contact area and increased contact pressures due to joint subluxation and incongruity could explain the progressive arthritis seen in some elbows affected by PMRI. Clinical Relevance: This biomechanical study suggests that the early degenerative changes associated with PMRI reported in the literature could be subsequent to joint incongruity and an increase in contact pressure between the coronoid fracture surface and the trochlea.
Determining the Validity and Accuracy of Multiple Activity-Tracking Devices in Controlled and Free-Walking Conditions
Gaz, Daniel V., Rieck, Thomas , Peterson, Nolan W., Ferguson, Jennifer A., Schroeder, Darrell R. , Dunfee, Heather A., Henderzahs-Mason, Jill M., Hagen, Philip T., Rieck, Thomas M, Schroeder, Darrell

Mayo Clinic

American Journal of Health Promotion | March 21, 2018 | Volume: 32 | Issue: 8 | Pages: 1671-1678

10.1177/0890117118763273 | PMID 29558811 Get It

Purpose: Clinicians and fitness professionals are increasingly recommending the use of activity trackers. This study compares commercially available activity tracking devices for step and distance accuracy in common exercise settings. Design: Cross sectional. Setting: Rochester, Minnesota. Participants: Thirty-two men (n = 10) and women (n = 22) participated in the study. Measures: Researchers manually counted steps and measured distance for all trials, while participants wore 6 activity tracking devices that measured steps and distance. Analysis: We computed the difference between the number of steps measured by the device and the actual number of steps recorded by the observers, as well as the distance displayed by the device and the actual distance measured. Results: The analyses showed that both the device and walking trials affected the accuracy of the results (steps or distance, P < .001). Hip-based devices were more accurate and consistent for measuring step count. No significant differences were found among devices or locations for the distance measured. Conclusions: Hip-based activity tracking devices varied in accuracy but performed better than their wrist-based counterparts for step accuracy. Distance measurements for both types of devices were more consistent but lacked accuracy.
Medicare Accountable Care Organization Enrollment and Appropriateness of Cancer Screening
Resnick, Matthew J., Graves, Amy J., Thapa, Sunita, Gambrel, Robert, Tyson, Mark D. , Buntin, Melinda Beeuwkes, Penson, David F. , Lee, Daniel

Mayo Clinic

JAMA Internal Medicine | March 19, 2018 | Volume: 178 | Issue: 5 | Pages: 648

10.1001/jamainternmed.2017.8087 | PMID 29554179 Get It