Aims Concurrent hip and spine pathologies can alter the biomechanics of spinopelvic mobility in primary total hip arthroplasty (THA). This study examines how differences in pelvic orientation of patients with spine fusions can increase the risk of dislocation risk after THA. Patients and Methods We identified 84 patients (97 THAs) between 1998 and 2015 who had undergone spinal fusion prior to primary THA. Patients were stratified into three groups depending on the length of lumbar fusion and whether or not the sacrum was involved. Mean age was 71 years (40 to 87) and 54 patients (56%) were female. The mean body mass index (BMI) was 30 kg/m2 (19 to 45). Mean follow-up was six years (2 to 17). Patients were 1:2 matched to patients with primary THAs without spine fusion. Hazard ratios (HR) were calculated. Results Dislocation in the fusion group was 5.2% at one year versus 1.7% in controls but this did not reach statistical significance (HR 1.9; p = 0.33). Compared with controls, there was no significant difference in rate of dislocation in patients without a sacral fusion. When the sacrum was involved, the rate of dislocation was significantly higher than in controls (HR 4.5; p = 0.03), with a trend to more dislocations in longer lumbosacral fusions. Patient demographics and surgical characteristics of THA (i.e. surgical approach and femoral head diameter) did not significantly impact risk of dislocation (p > 0.05). Significant radiological differences were measured in mean anterior pelvic tilt between the one-level lumbar fusion group (22°), the multiple-level fusion group (27°), and the sacral fusion group (32°; p < 0.01). Ten-year survival was 93% in the fusion group and 95% in controls (HR 1.2; p = 0.8). Conclusion Lumbosacral spinal fusions prior to THA increase the risk of dislocation within the first six months. Fusions involving the sacrum with multiple levels of lumbar involvement notably increased the risk of postoperative dislocation compared with a control group and other lumbar fusions. Surgeons should take care with component positioning and may consider higher stability implants in this high-risk cohort.
Abstract WP403: Factors Associated With Patient-Reported Shared Decision-Making for Stroke Prevention in Atrial Fibrillation
Introduction: Shared decision making (SDM) incorporates patient and physician values and preferences into treatment selection. While multiple therapeutic options are available for stroke prevention in atrial fibrillation (AF), few studies have examined factors associated with SDM regarding choice of antithrombotic strategy. Methods: We evaluated survey data from 1006 patients with new-onset AF enrolled at 56 sites participating in a substudy of the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation (ORBIT II), an outpatient AF registry in the US. Patients were asked: “When choosing your blood thinner(s), who made this treatment decision?”, and SDM was defined as a response of “equally me and my healthcare provider (HCP)”, “mostly me” or “entirely me”, while no SDM was defined as a response of “mostly my HCP” or “entirely my HCP”. Multivariable logistic regression models evaluated associations between 13 patient-level factors, self-reported understanding of treatment options, and SDM for antithrombotic therapy. Results: Most patients allowed their HCP to make the therapeutic decisions on antithrombotic strategy, with 246 (24.5%) reporting SDM. Patients reporting SDM were more often female (47.2% vs. 40.5%) and were more frequently insured by Medicare (40.2% vs. 34.5%) than patients reporting no SDM. Among patients taking warfarin, median time in therapeutic range was higher among patients reporting SDM than among those not reporting SDM. In multivariable models, chronic obstructive pulmonary disease was associated with lower odds of SDM while self-reported understanding of blood thinner options was associated with higher odds of SDM (Table). Conclusion: One in four patients in an outpatient AF registry reported that their current antithrombotic strategy was the result of a shared decision making process. Additional work is need to determine whether patient-reported SDM is associated with medication adherence and outcomes of therapy.
Abstract WP161: Computational Fluid Dynamics Using SAMMPRIS CT Angiography Quantifies Pro-Atherogenic Shear Stress Linked With Post-Stenotic Flow Vortices
Background: Low wall shear stress (LSS) is an established cause of pro-atherogenic endothelial pathophysiology, yet it has never been demonstrated in the cerebral circulation affected by intracranial atherosclerotic disease (ICAD). Noninvasive CT angiography (CTA) computational fluid dynamics (CFD) enables high-resolution investigation of detailed post-stenotic phenomena. We used all available CTA data in the SAMMPRIS trial of ICAD to detect and quantify post-stenotic LSS. Methods: CTA source images from SAMMPRIS were reconstructed in 3D followed by geometry refinements to generate a mesh of the diseased arterial lesion and adjacent segments. CFD was performed with Ansys (ICEM, Fluent), applying reference boundary conditions with k-omega turbulence and non-Newtonian modeling of the traversing blood viscosity. 3D CFD parameter maps illustrated velocity, velocity swirling and corresponding wall shear stress. Results: 144 subjects enrolled in SAMMPRIS had CTA at baseline, including 140 with CTA source images enabling CFD. Post-stenotic velocity profiles revealed vortices in all cases, quantified by swirling and turbulent kinetic energy. These luminal flow changes were adjacent to focal regions of LSS in the post-stenotic region (Figure). Conclusions: Low wall shear stress is associated with vortices of fluid flow in CTA CFD modeling of ICAD from SAMMPRIS. CTA source images may be used to noninvasively quantify LSS and model this pro-atherogenic factor in ICAD across a wide variety of lesions. Future studies should examine the related endothelial biology and potential link with plaque evolution.
Abstract TP582: A Multi-Site Validation of MRI Biomarkers of Vascular Leak and Hemorrhage for Forthcoming Clinical Trials
Background: Cerebral cavernous malformation is a genetic neurovascular disorder causing aberrant angiogenesis and lesion development within capillary beds. Lesions exhibit impaired endothelial barrier function, causing blood-brain barrier leakage and hemorrhage. Quantitative MRI biomarkers (dynamic contrast-enhanced quantitative permeability (DCEQP) and quantitative susceptibility mapping (QSM)) have been shown to correlate with CCM disease progression as measures of barrier leakage and hemorrhagic iron deposition, and there is interest in utilizing these biomarkers as endpoints in clinical trials. However, their consistencies across multiple platforms and institutions has not yet been rigorously verified. Materials and Methods: Instruments used were a 3T Philips Ingenia at University of Chicago and a 3T Siemens Prisma at Northwestern University. QSM was assessed by five balloons filled with varying concentrations of MultiHance, corresponding to magnetic susceptibilities of 0, 0.1, 0.2, 0.4, and 0.8, surrounded by an agarose gel. Permeability was assessed by the injection of a bolus of MultiHance through a coiled hose inside a water-filled shell, and the consistency of the peak-to-peak ratio of the curves at the input and output was measured. Each biomarker was assessed by accuracy (to expected values, Pearson correlation), precision (between repeated measurements, paired t-test), and reproducibility (between instruments, paired t-test). Results: QSM measured with an accuracy of r 2 = 0.997 on the Philips Achieva and r 2 = 0.999 on the Siemens Prisma. Each scanner had adequate precision between measurements, showing no significant difference by a paired t-test (p = 0.66 Achieva, p = 0.45 Prisma), and the reproducibility between scanners also showed no significant difference (p = 0.89). The peak-to-peak ratio on DCEQP scans was accurate (r 2 = 0.998), precise between measurements (p = 0.54), and repeatable between instruments (p = 0.49). Conclusion: Quantitative imaging biomarkers DCEQP and QSM are accurate, consistent across multiple measurements, and between platforms and will be useful for future clinical trials in CCM.