Citations

Clear

585 citation(s) found for "Tran, Ha".

The role of serologic testing for Zika virus infection
Tran, Anthony , Theel, Elitza S.

Mayo Clinic

Reviews in Medical Microbiology | December 12, 2017 | Volume: 29 | Issue: 1 | Pages: 1-7

10.1097/mrm.0000000000000122 Get It

Direct detection of Zika virus (ZIKV) nucleic acid with nucleic acid tests is definitive laboratory evidence of infection. Initial studies suggest that the ZIKV viremic period is limited, leading the Centers for Disease Control and Prevention to recommend that nucleic acid tests be utilized only up to 14 days postsymptom onset in serum and urine. The host immune response to flaviviruses, including to ZIKV, primarily targets the viral envelope (E) protein, which has three main domains (ED I–III). Recent studies suggest that neutralizing antibodies against the EDIII domain are relatively specific and potentially able to discriminate between ZIKV and dengue virus, which share 29% amino acid homology at that region. Comparatively, neutralizing antibodies to EDI and EDII, with amino acid homologies of 35 and 51% between these two viruses, respectively, are highly cross-reactive and likely responsible for the nonspecific reactions observed in the respective serologic assays. The current article describes the humoral immune response to ZIKV, reviews serologic assays for detection of antibodies to ZIKV, discusses performance characteristics of commercially available tests, and summarizes the strengths and limitations of currently available serologic methods. Assays examined in the review include the Centers for Disease Control and Prevention Zika IgM antibody capture ELISA, InBios ZIKV Detect IgM Capture ELISA, DiaSorin, LIAISON XL Zika Capture IgM Assay, Euroimmun anti-ZIKV IgM ELISA, and plaque reduction neutralization tests. Despite the availability of multiple diagnostic tests, there remains a need for modified and novel testing strategies, including the potential use of multiple enzyme immunoassays either in parallel or sequentially and IgG in addition to IgM determination.
A Novel Signaling Complex between TROY and EGFR Mediates Glioblastoma Cell Invasion
Ding, Zonghui , Roos, Alison , Kloss, Jean , Peng, Sen, Pirrotte, Patrick , Eschbacher, Jennifer M., Tran, Nhan L. , Loftus, Joseph C. , Dhruv, Harshil , Tran, Nhan L

Mayo Clinic

Molecular Cancer Research | November 8, 2017 | Volume: 16 | Issue: 2 | Pages: 322-332

10.1158/1541-7786.mcr-17-0454 | PMID 29117939 Get It

Abstract Glioblastoma is the most frequent primary brain tumor in adults and a highly lethal malignancy with a median survival of about 15 months. The aggressive invasion of the surrounding normal brain makes complete surgical resection impossible, increases the resistance to radiation and chemotherapy, and assures tumor recurrence. Thus, there is an urgent need to develop innovative therapeutics to target the invasive tumor cells for improved treatment outcomes of this disease. Expression of TROY (TNFRSF19), a member of the tumor necrosis factor (TNF) receptor family, increases with increasing glial tumor grade and inversely correlates with patient survival. Increased expression of TROY stimulates glioblastoma cell invasion in vitro and in vivo and increases resistance to temozolomide and radiation therapy. Conversely, silencing TROY expression inhibits glioblastoma cell invasion, increases temozolomide sensitivity, and prolongs survival in an intracranial xenograft model. Here, a novel complex is identified between TROY and EGFR, which is mediated predominantly by the cysteine-rich CRD3 domain of TROY. Glioblastoma tumors with elevated TROY expression have a statistically positive correlation with increased EGFR expression. TROY expression significantly increases the capacity of EGF to stimulate glioblastoma cell invasion, whereas depletion of TROY expression blocks EGF stimulation of glioblastoma cell invasion. Mechanistically, TROY expression modulates EGFR signaling by facilitating EGFR activation and delaying EGFR receptor internalization. Moreover, the association of EGFR with TROY increases TROY-induced NF-κB activation. These findings substantiate a critical role for the TROY–EGFR complex in regulation of glioblastoma cell invasion. Implications: The TROY–EGFR signaling complex emerges as a potential therapeutic target to inhibit glioblastoma cell invasion. Mol Cancer Res; 16(2); 322–32. ©2017 AACR.
Prospective Feasibility Trial for Genomics-Informed Treatment in Recurrent and Progressive Glioblastoma
Tran, Nhan L. , Halperin, Rebecca F. , Phillips, Joanna J. , Kuhn, John G. , Groot, John F. de, Colman, Howard , Wen, Patrick Y. , Mellinghoff, Ingo K. , Butowski, Nicholas , Taylor, Jennie , Clarke, Jennifer , Chang, Susan M. , Molinaro, Annette M. , Maggiora, Gerald M. , Peng, Sen, Liang, Winnie S. , Trent, Jeffrey M. , Berens, Michael E. , Carpten, John D. , Craig, David W. , Prados, Michael D. , Berens, Michael E , Byron, Sara A. , Colman, Howard , Ligon, Keith L , Wen, Patrick Yung , Cloughesy, Timothy F. , Chang, Susan Marina , Berger, Mitchel S. , Molinaro, Annette M. , Nasser, Sara A. , Mellinghoff, Ingo K , Tran, Nhan L

Mayo Clinic

Clinical Cancer Research | October 26, 2017 | Volume: 24 | Issue: 2 | Pages: 295-305

10.1158/1078-0432.ccr-17-0963 | PMID 29074604 Get It

Abstract Purpose: Glioblastoma is an aggressive and molecularly heterogeneous cancer with few effective treatment options. We hypothesized that next-generation sequencing can be used to guide treatment recommendations within a clinically acceptable time frame following surgery for patients with recurrent glioblastoma. Experimental Design: We conducted a prospective genomics-informed feasibility trial in adults with recurrent and progressive glioblastoma. Following surgical resection, genome-wide tumor/normal exome sequencing and tumor RNA sequencing were performed to identify molecular targets for potential matched therapy. A multidisciplinary molecular tumor board issued treatment recommendations based on the genomic results, blood–brain barrier penetration of the indicated therapies, drug–drug interactions, and drug safety profiles. Feasibility of generating genomics-informed treatment recommendations within 35 days of surgery was assessed. Results: Of the 20 patients enrolled in the study, 16 patients had sufficient tumor tissue for analysis. Exome sequencing was completed for all patients, and RNA sequencing was completed for 14 patients. Treatment recommendations were provided within the study's feasibility time frame for 15 of 16 (94%) patients. Seven patients received treatment based on the tumor board recommendations. Two patients reached 12-month progression-free survival, both adhering to treatments based on the molecular profiling results. One patient remained on treatment and progression free 21 months after surgery, 3 times longer than the patient's previous time to progression. Analysis of matched nonenhancing tissue from 12 patients revealed overlapping as well as novel putatively actionable genomic alterations. Conclusions: Use of genome-wide molecular profiling is feasible and can be informative for guiding real-time, central nervous system–penetrant, genomics-informed treatment recommendations for patients with recurrent glioblastoma. Clin Cancer Res; 24(2); 295–305. ©2017 AACR. See related commentary by Wick and Kessler, p. 256
MICRODOSIMETRIC APPLICATIONS IN PROTON AND HEAVY ION THERAPY USING SILICON MICRODOSIMETERS
Chartier, Lachlan, Tran, Linh T. , Bolst, David , Guatelli, Susanna , Pogossov, A, Prokopovich, Dale A., Reinhard, Mark I., Perevertaylo, Vladimir L. , Anderson, Sarah , Beltran, Chris , Matsufuji, Naruhiro, Jackson, Michael , Rosenfeld, Anatoly , Guatelli, S , Rosenfeld, A B , Beltran, Chris J , Anderson, S

Mayo Clinic

Radiation Protection Dosimetry | October 10, 2017 | Volume: 180 | Issue: 1-4 | Pages: 365-371

10.1093/rpd/ncx226 | PMID 29069515 Get It

Microdosimetric measurements of a clinical proton beam with micrometer‐sized solid‐state detector
Anderson, Sarah , Tran, Linh T. , Chartier, Lachlan, Petasecca, Marco , Lerch, Michael , Prokopovich, Dale A., Reinhard, Mark I., Perevertaylo, Vladimir L. , Rosenfeld, Anatoly , Herman, Michael , Beltran, Chris , Anderson, Sarah E, Furutani, Keith M. , Herman, Michael G., Rosenfeld, A B , Beltran, Chris J , Anderson, Sarah E.

Mayo Clinic

Medical Physics | September 14, 2017 | Volume: 44 | Issue: 11 | Pages: 6029-6037

10.1002/mp.12583 | PMID 28905399 Get It

PurposeMicrodosimetry is a vital tool for assessing the microscopic patterns of energy deposition by radiation, which ultimately govern biological effect. Solid‐state, silicon‐on‐insulator microdosimeters offer an approach for making microdosimetric measurements with high spatial resolution (on the order of tens of micrometers). These high‐resolution, solid‐state microdosimeters may therefore play a useful role in characterizing proton radiotherapy fields, particularly for making highly resolved measurements within the Bragg peak region. In this work, we obtain microdosimetric measurements with a solid‐state microdosimeter (MicroPlus probe) in a clinical, spot‐scanning proton beam of small spot size.MethodsThe MicroPlus probe had a 3D single sensitive volume on top of silicon oxide. The sensitive volume had an active cross‐sectional area of 250 μm × 10 μm and thickness of 10 μm. The proton facility was a synchrotron‐based, spot‐scanning system with small spot size (σ ≈ 2 mm). We performed measurements with the clinical beam current (≈1 nA) and had no detected pulse pile‐up. Measurements were made in a water‐equivalent phantom in water‐equivalent depth (WED) increments of 0.25 mm or 1.0 mm along pristine Bragg peaks of energies 71.3 MeV and 159.9 MeV, respectively. For each depth, we measured lineal energy distributions and then calculated the dose‐weighted mean lineal energy, . The measurements were repeated for two field sizes: 4 × 4 cm2 and 20 × 20 cm2.ResultsFor both 71.3 MeV and 159.9 MeV and for both field sizes, increased with depth toward the distal edge of the Bragg peak, a result consistent with Monte Carlo calculations and measurements performed elsewhere. For the 71.3 MeV, 4 × 4 cm2 beam (range at 80% distal falloff, R80 = 3.99 cm), we measured keV/μm at WED = 2 cm, and keV/μm at WED = 3.95 cm. For the 71.3 MeV, 20 × 20 cm2 beam, we measured keV/μm at WED = 2.6 cm, and keV/μm at WED = 3 cm. For the 159.9 MeV, 4 × 4 cm2 beam (R80 = 17.7 cm), keV/μm at WED = 5 cm, and keV/μm at WED = 17.6 cm. For the 159.9 MeV, 20 × 20 cm2 beam, keV/μm at WED = 5 cm, and keV/μm at WED = 17.6 cm.ConclusionsWe performed microdosimetric measurements with a novel solid‐state, silicon‐on‐insulator microdosimeter in a clinical spot‐scanning proton beam of small spot size and unmodified beam current. For all of the proton field sizes and energies considered, the measurements of were in agreement with expected trends. Furthermore, we obtained measurements with a spatial resolution of 10 μm in the beam direction. This spatial resolution greatly exceeded that possible with a conventional gaseous tissue‐equivalent proportional counter and allowed us to perform a high‐resolution investigation within the Bragg peak region. The MicroPlus probe is therefore suitable for applications in proton radiotherapy.
Characterization of proton pencil beam scanning and passive beam using a high spatial resolution solid‐state microdosimeter
Tran, Linh T. , Chartier, Lachlan, Bolst, David , Pogossov, Alex , Guatelli, Susanna , Petasecca, Marco , Lerch, Michael , Prokopovich, Dale A., Reinhard, Mark I., Clasie, B. , Depauw, Nicolas , Kooy, Hanne M., Flanz, J., McNamara, Aimee L. , Beltran, Chris , Perevertaylo, Vladimir L. , Jackson, Michael , Rosenfeld, Anatoly , Furutani, Keith, Guatelli, S , Rosenfeld, A B , Beltran, Chris J , Paganetti, Harald , Furutani, Keith M.

Mayo Clinic

Medical Physics | September 9, 2017 | Volume: 44 | Issue: 11 | Pages: 6085-6095

10.1002/mp.12563 | PMID 28887837 Get It

PurposeThis work aims to characterize a proton pencil beam scanning (PBS) and passive double scattering (DS) systems as well as to measure parameters relevant to the relative biological effectiveness (RBE) of the beam using a silicon on insulator (SOI) microdosimeter with well‐defined 3D sensitive volumes (SV). The dose equivalent downstream and laterally outside of a clinical PBS treatment field was assessed and compared to that of a DS beam.MethodsA novel silicon microdosimeter with well‐defined 3D SVs was used in this study. It was connected to low noise electronics, allowing for detection of lineal energies as low as 0.15 keV/μm. The microdosimeter was placed at various depths in a water phantom along the central axis of the proton beam, and at the distal part of the spread‐out Bragg peak (SOBP) in 0.5 mm increments. The RBE values of the pristine Bragg peak (BP) and SOBP were derived using the measured microdosimetric lineal energy spectra as inputs to the modified microdosimetric kinetic model (MKM). Geant4 simulations were performed in order to verify the calculated depth‐dose distribution from the treatment planning system (TPS) and to compare the simulated dose‐mean lineal energy to the experimental results.ResultsFor a 131 MeV PBS spot (124.6 mm R90 range in water), the measured dose‐mean lineal energy increased from 2 keV/μm at the entrance to 8 keV/μm in the BP, with a maximum value of 10 keV/μm at the distal edge. The derived RBE distribution for the PBS beam slowly increased from 0.97 ± 0.14 at the entrance to 1.04 ± 0.09 proximal to the BP, then to 1.1 ± 0.08 in the BP, and steeply rose to 1.57 ± 0.19 at the distal part of the BP. The RBE distribution for the DS SOBP beam was approximately 0.96 ± 0.16 to 1.01 ± 0.16 at shallow depths, and 1.01 ± 0.16 to 1.28 ± 0.17 within the SOBP. The RBE significantly increased from 1.29 ± 0.17 to 1.43 ± 0.18 at the distal edge of the SOBP.ConclusionsThe SOI microdosimeter with its well‐defined 3D SV has applicability in characterizing proton radiation fields and can measure relevant physical parameters to model the RBE with submillimeter spatial resolution. It has been shown that for a physical dose of 1.82 Gy at the BP, the derived RBE based on the MKM model increased from 1.14 to 1.6 in the BP and its distal part. Good agreement was observed between the experimental and simulation results, confirming the potential application of SOI microdosimeter with 3D SV for quality assurance in proton therapy.
Cold platelets for trauma‐associated bleeding: regulatory approval, accreditation approval, and practice implementation—just the “tip of the iceberg”
Stubbs, James R. , Tran, Sheryl A., Emery, Richard L., Hammel, Scott A., Haugen, De Anna L., Zielinski, Martin D. , Zietlow, Scott P., Jenkins, Donald H.

Mayo Clinic

Transfusion | September 7, 2017 | Volume: 57 | Issue: 12 | Pages: 2836-2844

10.1111/trf.14303 | PMID 28880362 Get It

BACKGROUNDLaboratory and clinical evidence suggest that cold‐stored platelets (CS‐PLTs) might be preferable to room temperature platelets (RT‐PLTs) for active bleeding. Ease of prehospital use plus potential hemostatic superiority led our facility to pursue approval of CS‐PLTs for actively bleeding trauma patients.STUDY DESIGN AND METHODSFrom November 18, 2013, through October 8, 2015, correspondence was exchanged between our facility, the AABB, and the US Food and Drug Administration (FDA). An initial AABB variance request was for 5‐day CS‐PLTs without agitation. The AABB deferred its decision pending FDA approval to use our platelet (PLT) bags for CS‐PLTs. On March 27, 2015, the FDA approved 3‐day CS‐PLTs without agitation. On October 8, 2015, the AABB approved 3‐day CS‐PLTs without agitation and without bacterial testing for actively bleeding trauma patients. Our facility's goal is to carry CS‐PLTs on air ambulances.RESULTSCS‐PLTs have been used for trauma patients at our facility since October 2015. As of August 2016, a total of 21 (19.1%) of 119 CS‐PLTs have been transfused. The short 3‐day storage period combined with the formation of clots in plasma‐rich CS‐PLTs during storage have been the major causes of a high (80.9%) discard rate.CONCLUSIONIn the future, pathogen‐reduced (PR), PLT additive solution (PAS) CS‐PLTs seem more practical due to low risks of bacterial contamination and storage‐related clotting. This should make longer storage of CS‐PLTs feasible (e.g., 10 days or more). With a longer shelf life, PR PAS CS‐PLTs could potentially be used in a wider range of patient populations.
Abstract LB-007: Leveraging spatial heterogeneity in tumor purity for improved somatic variant calling of archival tumor-only samples
Halperin, Rebecca F. , Tassone, Erica E. , Adkins, Jonathan, Russell, Megan, Tran, Nhan L. , Hank, Nicole C., Newell, James, Berens, Michael, Korn, Ronald L. , Craig, David W. , Liang, Winnie S. , Newell, James, Gupta, Sandeep , Byron, Sara A. , Tran, Nhan L

Mayo Clinic

Cancer Research | July 31, 2017 | Volume: 77 | Issue: 13_Supplement | Pages: LB-007-LB-007

10.1158/1538-7445.am2017-lb-007 Get It

Abstract Archival tumor samples present a rich resource of annotated specimens for genomics research. However, standard variant calling approaches require a matched normal sample from the same individual, which is often not available with archival tissue. Without a matched normal sample, it is very difficult to distinguish between true somatic variants and germline variants that are private to the individual. Archival FFPE sections often contain adjacent normal tissue, but this normal tissue is often contaminated with infiltrating tumor cells. Comparative somatic variant callers are designed to exclude variants present in the normal sample, so a novel approach is required to leverage sequencing of adjacent normal tissue. Here we present LumosVar 2.0, a software package designed to jointly analyze multiple samples from the same patient. The approach is based on the concept that the allelic fraction of somatic variants, but not germline variants, would be diluted by the presence of normal tissue. Given the allele specific copy number state and expected tumor fraction of each sample, one can model the expected allelic fractions of somatic and germline variants. LumosVar estimates allele specific copy number and tumor sample fractions from the data, and uses the model to call somatic and germline variants. LumosVar is also able to detect sub clonal events and spatial heterogeneity between samples. To evaluate this approach, we used a glioblastoma dataset, where enhancing (high tumor content) and non-enhancing (low tumor content) samples were available for each patient, as well as the matched normal sample to define the true somatic variants. We show that both sensitivity and positive predictive value are improved by analyzing the high tumor and low tumor jointly compared to analyzing the samples individually or in silico pooling of the two samples. Finally, we apply this approach to a set of breast and prostate archival FFPE tumor samples where normal samples were not available for germline sequencing. Citation Format: Rebecca F. Halperin, Winnie S. Liang, Erica Tassone, Jonathan Adkins, Megan Russell, Nhan Tran, Nicole Hank, James Newell, Sandeep Gupta, Michael Berens, Ronald Korn, David W. Craig, Sara A. Byron. Leveraging spatial heterogeneity in tumor purity for improved somatic variant calling of archival tumor-only samples [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2017; 2017 Apr 1-5; Washington, DC. Philadelphia (PA): AACR; Cancer Res 2017;77(13 Suppl):Abstract nr LB-007. doi:10.1158/1538-7445.AM2017-LB-007
Abstract 1878: PDZ-RhoGEF functions as a critical signaling effector for TROY
Roos, Alison , Kloss, Jean , Symons, Marc , Tran, Nhan L. , Loftus, Joseph C. , Ding, Zonghui , Dhruv, Harshil , Tran, Nhan L

Mayo Clinic

Cancer Research | July 31, 2017 | Volume: 77 | Issue: 13_Supplement | Pages: 1878-1878

10.1158/1538-7445.am2017-1878 Get It

Abstract Glioblastoma Multiforme (GBM) is the most common tumor of the CNS with a median survival of approximately 15 months. The highly aggressive invasion of malignant cells into the surrounding normal brain tissue renders complete surgical resection impossible, increases therapeutic resistance, and virtually assures tumor recurrence. We have previously demonstrated that TROY (TNFRSF19) has an important role in GBM invasion and resistance. TROY expression is correlated with glial tumor grade and inversely correlated with patient survival. Increased TROY expression stimulated cell migration/invasion in vitro and in vivo and confers resistance to both ionizing radiation- and temozolomide-induced apoptosis via activation of Akt and NF-κB. These data indicate that TROY stimulated migration/invasion is associated with signaling pathways that also increase survival and therapeutic resistance, however, the mechanistic basis of this signaling remains unclear. To investigate the mechanism by which TROY induces GBM cell invasion, we performed immunoprecipitation of the TROY receptor coupled with MALDI-TOF and MS/MS analysis and identified PDZ-RhoGEF as a binding partner for TROY. We validated the interaction of TROY with PDZ-RhoGEF by immunoprecipitation and western blotting, and demonstrated that PDZ-RhoGEF can exchange for both RhoA and RhoC in glioma cells and is implicated in GBM cell invasion, proliferation, and survival. In order to assess the specific role of PDZ-RhoGEF in TROY signaling, we examined the effects of PDZ-RhoGEF on TROY-mediated activation of NF-κB. While overexpression of TROY alone strongly stimulated NF-κB transcriptional activity in serum-free conditions, increased expression of PDZ-RhoGEF alone had no effect on NF-κB activity. Co-transfection of PDZ-RhoGEF with TROY synergistically promoted NF-κB activation. Mutation of the TRAF binding domain (TBD) in the cytoplasmic domain of TROY abolished its capacity to activate NF-κB, even in the presence of PDZ-RhoGEF, suggesting that the TBD is important for TROY induced NF-κB activation. Furthermore, knockdown of PDZ-RhoGEF by shRNA attenuated NF-κB activation in TROY expressing cells, blocked TROY mediated invasion of primary GBM xenograft cells and increased sensitivity to temozolomide. Collectively, these data indicate that PDZ-RhoGEF plays an important role in TROY signaling and provides insights into a potential node of vulnerability to limit GBM cell invasion and decrease therapeutic resistance. Citation Format: Zonghui Ding, Alison Roos, Jean Kloss, Harshil Dhruv, Marc Symons, Nhan L. Tran, Joseph C. Loftus. PDZ-RhoGEF functions as a critical signaling effector for TROY [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2017; 2017 Apr 1-5; Washington, DC. Philadelphia (PA): AACR; Cancer Res 2017;77(13 Suppl):Abstract nr 1878. doi:10.1158/1538-7445.AM2017-1878