Citations

Clear

635 citation(s) found for "Carter, R".

Risk Factors for Readmission with Cerebrospinal Fluid Leakage Within 30 Days of Vestibular Schwannoma Surgery
Alattar, Ali , Hirshman, Brian R. , McCutcheon, Brandon A., Chen, Clark C. , Alexander, Thomas H., Harris, Jeffrey P. , Carter, Bob S.

Mayo Clinic

Neurosurgery | June 6, 2017 | Volume: 82 | Issue: 5 | Pages: 630-637

10.1093/neuros/nyx197 | PMID 28633408 Get It

Abstract BACKGROUND Cerebrospinal fluid (CSF) leak is a well-recognized complication after surgical resection of vestibular schwannomas and is associated with a number of secondary complications, including readmission and meningitis. OBJECTIVE To identify risk factors for and timing of 30-d readmission with CSF leak. METHODS Patients who had undergone surgical resection of a vestibular schwannoma from 1995 to 2010 were identified in the California Office of Statewide Health Planning and Development database. The most common admission diagnoses were identified by International Classification of Disease, ninth Revision, diagnosis codes, and predictors of readmission with CSF leak were determined using logistic regression. RESULTS A total of 6820 patients were identified. CSF leak, though a relatively uncommon cause of admission after discharge (3.52% of all patients), was implicated in nearly half of 490 readmissions (48.98%). Significant independent predictors of readmission with CSF leak were male sex (odds ratio [OR] 1.72, 95% confidence interval [CI] 1.32-2.25), first admission at a teaching hospital (OR 3.32, 95% CI 1.06-10.39), CSF leak during first admission (OR 1.84, 95% CI 1.33-2.55), obesity during first admission (OR 2.10, 95% CI 1.20-3.66), and case volume of first admission hospital (OR of log case volume 0.82, 95% CI 0.70-0.95). Median time to readmission was 6 d from hospital discharge. CONCLUSION This study has quantified CSF leak as an important contributor to nearly half of all readmissions following vestibular schwannoma surgery. We propose that surgeons should focus on technical factors that may reduce CSF leakage and take advantage of potential screening strategies for the detection of CSF leakage prior to first admission discharge.
Automated low‐contrast pattern recognition algorithm for magnetic resonance image quality assessment
Ehman, Morgan O., Bao, Zhonghao , Stiving, Scott O., Kasam, Mallikarjunarao , Lanners, Dianna , Peterson, Teresa, Jonsgaard, Renee , Carter, Rickey E. , McGee, Kiaran P. , Kasam, Mallik, Carter, Rickey, Carter, Rickey E

Mayo Clinic

Medical Physics | May 25, 2017 | Volume: 44 | Issue: 8 | Pages: 4009-4024

10.1002/mp.12370 | PMID 28543961 Get It

PurposeLow contrast (LC) detectability is a common test criterion for diagnostic radiologic quality control (QC) programs. Automation of this test is desirable in order to reduce human variability and to speed up analysis. However, automation is challenging due to the complexity of the human visual perception system and the ability to create algorithms that mimic this response. This paper describes the development and testing of an automated LC detection algorithm for use in the analysis of magnetic resonance (MR) images of the American College of Radiology (ACR) QC phantom.MethodsThe detection algorithm includes fuzzy logic decision processes and various edge detection methods to quantify LC detectability. Algorithm performance was first evaluated using a single LC phantom MR image with the addition of incremental zero mean Gaussian noise resulting in a total of 200 images. A c‐statistic was calculated to determine the role of CNR to indicate when the algorithm would detect ten spokes. To evaluate inter‐rater agreement between experienced observers and the algorithm, a blinded observer study was performed on 196 LC phantom images acquired from nine clinical MR scanners. The nine scanners included two MR manufacturers and two field strengths (1.5 T, 3.0 T). Inter‐rater and algorithm‐rater agreement was quantified using Krippendorff's alpha.ResultsFor the Gaussian noise added data, CNR ranged from 0.519 to 11.7 with CNR being considered an excellent discriminator of algorithm performance (c‐statistic = 0.9777). Reviewer scoring of the clinical phantom data resulted in an inter‐rater agreement of 0.673 with the agreement between observers and algorithm equal to 0.652, both of which indicate significant agreement.ConclusionsThis study demonstrates that the detection of LC test patterns for MR imaging QC programs can be successfully developed and that their response can model the human visual detection system of expert MR QC readers.
Prognostic and biological significance of the proangiogenic factor EGFL7 in acute myeloid leukemia
Papaioannou, Dimitrios , Shen, Changxian , McNeil, Betina, Bill, Marius , Karunasiri, Malith, Burke, Matthew H. , Özer, Hatice Gülçin , Yilmaz, Selen, Zitzer, Nina C. , Behbehani, Gregory K. , Oakes, Christopher C. , Steiner, Damian J., Marcucci, Guido , Powell, Bayard L., Kolitz, Jonathan E. , Carter, Thomas H. , Wang, Eunice S. , Mrózek, Krzysztof , Bloomfield, Clara D. , Garzon, Ramiro , Dorrance, Adrienne M. , Nicolet, Deedra , Wang, Eunice S. , Croce, Carlo Maria , Caligiuri, Michael A.

Mayo Clinic

Proceedings of the National Academy of Sciences | May 22, 2017 | Volume: 114 | Issue: 23 | Pages: No page available

10.1073/pnas.1703142114 | PMID 28533390 Get It

Significance In this work we report on the previously uncharacterized clinical and biological role for EGFL7 in acute myeloid leukemia (AML). Patients with increased EGFL7 mRNA expression had lower complete remission rates and shorter overall and event-free survival, demonstrating the clinical relevance of EGFL7 expression in cytogenetically normal AML. Our results show that AML blasts are able to synthesize and secrete EGFL7 protein, promoting autocrine blast cell growth. Inhibition of EGFL7 results in decreased proliferation and induces apoptosis of AML cells. Taken together, our data provide the rationale for targeting EGFL7 using blocking antibodies as a therapy for patients with AML.
Percutaneous Pericardial Resection
Borlaug, Barry A. , Carter, Rickey E. , Melenovský, Vojtěch , Gaba, Prakriti , Killu, Ammar M. , Naksuk, Niyada , Lerman, Lilach O. , Asirvatham, Samuel J. , Killu, Ammar, Lerman, Lilach, DeSimone, Christopher V. , Asirvatham, Samuel J , Borlaug, Barry A , Carter, Rickey E , Melenovský, Vojtěch

Mayo Clinic

Circulation: Heart Failure | April 11, 2017 | Volume: 10 | Issue: 4 | Pages: No page available

10.1161/circheartfailure.116.003612 | PMID 28396500 Get It

Background— People with heart failure and preserved ejection fraction develop increases in left ventricular (LV) end-diastolic pressures during exercise that contribute to dyspnea. In normal open-chest animal preparations, the pericardium restrains LV filling when central blood volume increases. We hypothesized that resection of the pericardium using a minimally invasive epicardial approach would mitigate the increase in LV end-diastolic pressure that develops during volume loading in normal and diseased hearts with the chest intact. Methods and Results— Invasive hemodynamic assessment was performed at baseline and after saline load before and after pericardial resection in normal canines with open (n=3) and closed chest (n=5) and in a pig model with features of human heart failure and preserved ejection fraction with sternum intact (n=4). In closed-chest animals, pericardiotomy was performed using a novel subxiphoid procedure. In both experimental preparations of normal dogs, pericardiotomy blunted the increase in LV end-diastolic pressure with saline infusion, while enhancing the saline-mediated increase in LV end-diastolic volume. With chest intact in the pig model, percutaneous pericardial resection again blunted the increase in LV end-diastolic pressure secondary to volume expansion (+4±3 versus +13±5 mm Hg; P =0.014), while enhancing the saline-mediated increase in LV end-diastolic volume (+17±1 versus +10±2 mL; P =0.016). Conclusions— This proof of concept study demonstrates that pericardial resection through a minimally invasive percutaneous approach mitigates the elevation in LV filling pressures with volume loading in both normal animals and a pig model with diastolic dysfunction. Further study is warranted to determine whether this method is safe and produces similar acute and chronic hemodynamic benefits in people with heart failure and preserved ejection fraction.
Changes in the Expression of Genes Associated with Intraneuronal Amyloid-β and Tau in Alzheimer's Disease
Fujimura, Robert K., Reiner, Teresita, Ma, Fangchao , Phillips, Virginia , Pozas, Alicia de las, Dickson, Dennis W. , Roos, Bernard A., Howard, Guy A., Perez‐Stable, Carlos , Dickson, Dennis W

Mayo Clinic

Journal of Alzheimer's Disease | April 5, 2017 | Volume: 19 | Issue: 1 | Pages: 97-109

10.3233/jad-2010-1216 | PMID 20061629 Get It

Continuous Glucose Monitor Interference With Commonly Prescribed Medications: A Pilot Study
Basu, Ananda , Slama, Michael , Nicholson, Wayne T. , Langman, Loralie J., Peyser, Thomas A. , Carter, Rickey E. , Basu, Rita , Slama, Michael Q, Langman, Loralie, Carter, Rickey E

Mayo Clinic

Journal of Diabetes Science and Technology | March 23, 2017 | Volume: 11 | Issue: 5 | Pages: 936-941

10.1177/1932296817697329 | PMID 28332406 Get It

Background: Reliability of continuous glucose monitors (CGM) is a prerequisite for therapeutic dosing of insulin without the need for confirmatory blood glucose meter measurements. Interference of CGMs with commonly prescribed substances has not been extensively evaluated. Methods: We sought to undertake a novel pilot study to determine the susceptibility of FDA-approved CGM systems (Medtronic Guardian Sof-Sensor, Dexcom G4 Platinum) to erroneous readings in the presence of common medications. CGMs were placed on the abdomen of healthy subjects 48 hours prior to study. Subjects were admitted to the Clinical Research Trials Unit (CRTU) on the evening before study and fed a standard supper. The following morning, an oral medication was administered in the fasted state and blood was sampled for 9 hours. CGM values were compared to ambient glucose (measured with YSI) to observe variations in CGM readings. Microdialysis catheters were also placed in the abdomen to sample interstitial fluid (ISF) for drug concentrations. Results: Nineteen healthy drug-naïve subjects without diabetes participated in the study. A drug/substance was tested up to a maximum of nine times on separate occasions. Comparison of CGM glucose patterns to actual plasma glucose concentrations show several drugs, including lisinopril, albuterol, and acetaminophen, appear to interfere with commonly used CGM devices. Wine also interfered with CGM readings. Conclusions: We conclude there is some evidence of CGM interference with lisinopril, albuterol, acetaminophen, atenolol, and red wine. Future studies are required to address interference with newer sensors being approved or in the process of approval.
A multi-reader in vitro study using porcine kidneys to determine the impact of integrated circuit detectors and iterative reconstruction on the detection accuracy, size measurement, and radiation dose for small (
Wells, Michael , Froemming, Adam T. , Vrtiska, Terri J., Hartman, Robert P. , Holmes, David R. , Carter, Rickey E. , Bartley, Adam C. , Wells, Michael L, Kawashima, Akira , Kim, Bohyun , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G. , Carter, Rickey E

Mayo Clinic

Acta Radiologica | March 6, 2017 | Volume: 58 | Issue: 8 | Pages: 1012-1019

10.1177/0284185116682382 | PMID 28273736 Get It

Background Detection of small renal calculi has benefitted from recent advances in computed tomography (CT) scanner design. Information regarding observer performance when using state-of-the-art CT scanners for this application is needed. Purpose To assess observer performance and the impact of radiation dose for detection and size measurement of <4 mm renal stones using CT with integrated circuit detectors and iterative reconstruction. Material and Methods Twenty-nine <4 mm calcium oxalate stones were randomly placed in 20 porcine kidneys in an anthropomorphic phantom. Four radiologists used a workstation to record each calculus detection and size. JAFROC Figure of Merit (FOM), sensitivity, false positive detections, and calculus size were calculated. Results Mean calculus size was 2.2 ± 0.7 mm. The CTDI vol values corresponding to the automatic exposure control settings of 160, 80, 40, 25, and 10 Quality Reference mAs (QRM) were 15.2, 7.9, 4.2, 2.7, and 1.3 mGy, respectively. JAFROC FOM was ≥ 0.97 at ≥ 80 QRM, ≥ 0.89 at ≥ 25 QRM, and was inferior to routine dose (160 QRM) at 10 QRM (0.72, P < 0.05). Per-calculus sensitivity remained ≥ 85% for every reader at ≥ 25 QRM. Mean total false positive detections per reader were ≤ 3 at ≥ 80 QRM, but increased substantially for two readers ( ≥ 12) at ≤ 40 QRM. Measured calculus size significantly decreased at ≤ 25 QRM ( P ≤ 0.01). Conclusion Using low dose renal CT with iterative reconstruction and ≥ 25 QRM results in high sensitivity, but false positive detections increase for some readers at very low dose levels (≤ 40 QRM). At very low doses with iterative reconstruction, measured calculus size will artifactually decrease.
A new model for predicting breast cancer risk in women with atypical hyperplasia.
Dupont, William D. , Frank, Ryan D. , Frost, Marlene H., Vachon, Celine M, Ghosh, Karthik , Haddad, Tufia C. , Denison, Lori A., Visscher, Daniel W., Hartmann, Lynn C. , Degnim, Amy C. , Pankratz, V. Shane , Winham, Stacey J. , Vierkant, Robert A. , Hieken, Tina J. , Carter, Jodi M. , Radisky, Derek C.

Mayo Clinic

Journal of Clinical Oncology | February 24, 2017 | Volume: 33 | Issue: 28_suppl | Pages: 2-2

10.1200/jco.2015.33.28_suppl.2 Get It

2 Background: Women with atypical hyperplasia (AH) on breast biopsy have an aggregate increased risk of breast cancer (BC), but accurate personalized risk prediction is desirable to facilitate individual clinical management decisions. Currently used models provide poor BC risk prediction for women with AH. Our goal was to develop and validate an improved risk prediction model for women with AH. Methods: From a cohort of 13,538 women with benign breast disease from 1967-2001, pathology review confirmed 699 with AH. Clinical risk factors and histologic features of the tissue biopsy were recorded, and BC events were ascertained from study questionnaires, tumor registry, and review of medical records. Using a lasso approach, 23 variables were assessed for model inclusion. Lasso-identified features were then fit in a Cox regression model to estimate BC risk. Model discrimination was assessed with C-statistics in the model-building set and in a separate external validation set. Calibration was assessed by comparing observed to predicted breast cancer counts. Results: The model-building set comprised 699 women with 142 BC events (median follow-up 8.1 years), and the external validation set comprised 461 women with 114 BC events (median follow-up 11.4 years). The final model included three covariates: age at biopsy, age squared, and number of foci of AH. Model performance was good, with a C-statistic of 0.622 (SE = 0.027) in the model-building set and 0.594 (SE = 0.029) in the external validation set. The model is well-calibrated, with observed to expected numbers of BCs nearly equal across all post-biopsy follow-up years. Conclusions: We propose a new model for predicting BC risk in women with AH based on age at biopsy and number of foci of atypia. This model provides absolute risk estimates for women with AH, has good discriminatory ability, is well-calibrated, and validates in an external cohort.
Breast Cancer Risk and Progressive Histology in Serial Benign Biopsies
Visscher, Daniel W., Frank, Ryan D. , Carter, Jodi M. , Vierkant, Robert A. , Heinzen, Ethan P. , Broderick, Brendan T., Denison, Lori A., Allers, Teresa M., Johnson, Joanne L., Frost, Marlene H., Hartmann, Lynn C. , Winham, Stacey J. , Radisky, Derek C. , Degnim, Amy C. , Vierkant, Robert A , Carter, Jodi

Mayo Clinic

JNCI: Journal of the National Cancer Institute | February 16, 2017 | Volume: 109 | Issue: 10 | Pages: No page available

10.1093/jnci/djx035 | PMID 28376198 Get It

Alterations in the Immune Cell Composition in Premalignant Breast Tissue that Precede Breast Cancer Development
Arshad, Muhammad Usman , Frost, Marlene H., Winham, Stacey J. , Brahmbhatt, Rushin, Peña, Alvaro, Carter, Jodi M. , Stallings‐Mann, Melody , Murphy, Linda M., Miller, Erin , Denison, Lori A., Vachon, Celine M. , Knutson, Keith L. , Visscher, Daniel W., Hoskin, Tanya L. , Brahmbhatt, Rushin A, Stallings-Mann, Melody L, Miller, Erin E, Radisky, Derek C. , Degnim, Amy C. , Vachon, Celine M. , Knutson, Keith L. , Winham, Stacey J , Carter, Jodi

Mayo Clinic

Clinical Cancer Research | January 26, 2017 | Volume: 23 | Issue: 14 | Pages: 3945-3952

10.1158/1078-0432.ccr-16-2026 | PMID 28126725 Get It

Abstract Purpose: Little is known about the role of the immune system in the earliest stages of breast carcinogenesis. We studied quantitative differences in immune cell types between breast tissues from normal donors and those from women with benign breast disease (BBD). Experimental Design: A breast tissue matched case–control study was created from donors to the Susan G. Komen for the Cure Tissue Bank (KTB) and from women diagnosed with BBD at Mayo Clinic (Rochester, MN) who either subsequently developed cancer (BBD cases) or remained cancer-free (BBD controls). Serial tissue sections underwent immunostaining and digital quantification of cell number per mm2 for CD4+ T cells, CD8+ T cells, CD20+ B cells, and CD68+ macrophages and quantification of positive pixel measure for CD11c (dendritic cells). Results: In 94 age-matched triplets, BBD lobules showed greater densities of CD8+ T cells, CD11c+ dendritic cells, CD20+ B cells, and CD68+ macrophages compared with KTB normals. Relative to BBD controls, BBD cases had lower CD20+ cell density (P = 0.04). Nearly 42% of BBD cases had no CD20+ B cells in evaluated lobules compared with 28% of BBD controls (P = 0.02). The absence of CD20+ cells versus the presence in all lobules showed an adjusted OR of 5.7 (95% confidence interval, 1.4–23.1) for subsequent breast cancer risk. Conclusions: Elevated infiltration of both innate and adaptive immune effectors in BBD tissues suggests an immunogenic microenvironment. The reduced B-cell infiltration in women with later breast cancer suggests a role for B cells in preventing disease progression and as a possible biomarker for breast cancer risk. Clin Cancer Res; 23(14); 3945–52. ©2017 AACR.