Citations

Clear

97 citation(s) found for "Zhao, Chunfeng".

Decellularized Fetal Matrix Suppresses Fibrotic Gene Expression and Promotes Myogenesis in a Rat Model of Volumetric Muscle Loss
Mazzucchelli, Lorenzo , Amadio, Peter C. , Kuroiwa, Tomoyuki , Zhao, Chunfeng

Mayo Clinic

Plastic & Reconstructive Surgery | October 28, 2021 | Volume: 148 | Issue: 4 | Pages: 670e-670e

10.1097/prs.0000000000008350 | PMID 34550953 Get It

The Effect of Gelatin Molecular Weight on Tendon Lubrication Utilizing an Extrasynovialized Turkey Flexor Tendon Model
Forthofer, BS Michael J, Arnold, Katherine M. , Reisdorf, Ramona L., Amadio, Peter C. , Zhao, Chunfeng , Forthofer Bs, Michael J, Arnold Ms, Katherine M, Reisdorf Bs, Ramona L, Amadio Md, Peter C, Zhao Md, Chunfeng, Forthofer, Michael

Mayo Clinic

Military Medicine | January 26, 2021 | Volume: 186 | Issue: Supplement_1 | Pages: 729-736

10.1093/milmed/usaa265 | PMID 33499438 Get It

ABSTRACT Introduction Flexor tendon injuries are common hand injuries among the military population often resulting in functional impairment. Flexor tendon gliding friction has been linked to adhesion formation, especially with the use of extrasynovial grafts. Carbodiimide-derivatized hyaluronic acid with gelatin (cd-HA-gelatin) can reduce gliding friction of the tendon graft; however, the effects of gelatin molecular weight (MW) have not been studied. The turkey model has been shown to better match humans, but extrasynovial tendons are unavailable. The purpose of this study was to (1) manually roughen turkey flexor digitorum profundus (FDP) tendons to simulate extrasynovial tendons and (2) investigate the effects of gelatin MW on tendon friction. Materials and Methods The third digit of (n = 48) turkeys were dissected with the proximal pulley, and FDP tendon and the flexor superficialis tendon were preserved. Digits were randomly assigned into four groups: one saline control and three cd-HA-gelatin-treated groups of varying gelatin MW. Flexor digitorum profundus tendon friction was measured at its original condition, serving as a baseline. Tendons were roughened using a custom rig, and tendon friction was measured again. All four groups received treatment and gliding friction was measured every 100 cycles to a total of 1,000 cycles. Results Tendon friction significantly increased (P < 0.05) after roughening. Friction in the saline control group increased steadily over repeated cycles, whereas friction of all gelatin-treated tendons decreased significantly compared with the saline control group (P < 0.05), maintaining low friction to 1,000 cycles representing human tendons. There was no significant difference found between gelatin-treated groups. Conclusions We have developed a method to roughen synovial FDP tendons to create extrasynovial-like tendons for lubrication material evaluations. Cd-HA-gelatin effectively reduces tendon friction in this model. Our data suggest medium or low MW gelatin may provide a better reduction in friction compared with high MW gelatin.
A novel engineered purified exosome product patch for tendon healing: An explant in an ex vivo model
Shi, Guidong , Wang, Zhanwen , Thoreson, Andrew R. , Jacobson, Daniel S. , Amadio, Peter C. , Behfar, Atta , Moran, Steven L. , Zhao, Chunfeng , Wang, Yicun , Zhao, Chunfeng , Behfar, Atta , Wang, Yicun , Shi, Guidong

Mayo Clinic

Journal of Orthopaedic Research | September 16, 2020 | Volume: 39 | Issue: 8 | Pages: 1825-1837

10.1002/jor.24859 | PMID 32936480 Get It

AbstractReducing tendon failure after repair remains a challenge due to its poor intrinsic healing ability. The purpose of this study is to investigate the effect of a novel tissue‐engineered purified exosome product (PEP) patch on tendon healing in a canine ex vivo model. Lacerated flexor digitorum profundus (FDP) tendons from three canines' paws underwent simulated repair with Tisseel patch alone or biopotentiated with PEP. For the ex vivo model, FDP tendons were randomly divided into three groups: FDP tendon repair alone group (Control), Tisseel patch alone group, and the Tisseel plus PEP (TEPEP) patch group. Following 4 weeks of tissue culture, the failure load, stiffness, histology, and gene expression of the healing tendon were evaluated. Transmission electron microscopy revealed that in exosomes of PEP the diameters ranged from 93.70 to 124.65 nm, and the patch release test showed this TEPEP patch could stably release the extracellular vesicle over 2 weeks. The failure strength of the tendon in the TEPEP patch group was significantly higher than that of the Control group and Tisseel alone group. The results of histology showed that the TEPEP patch group had the smallest healing gap and the largest number of fibroblasts on the surface of the injured tendon. Quantitative reverse transcription polymerase chain reaction showed that TEPEP patch increased the expression of collagen type III, matrix metallopeptidase 2 (MMP2), MMP3, MMP14, and reduced the expression of transforming growth factor β1, interleukin 6. This study shows that the TEPEP patch could promote tendon repair by reducing gap formation and inflammatory response, increasing the activity of endogenous cells, and formation of type III collagen.
Biomechanical Comparison of Augmentation of Engineered Tendon-Fibrocartilage-Bone Composite With Acellular Dermal Graft Using Double Rip-Stop Technique for Canine Rotator Cuff Repair
Wang, Zhanwen , Long, Zeling , Amadio, Peter C. , Gingery, Anne , Moran, Steven L. , Steinmann, Scott P. , Zhao, Chunfeng , Gingery, Anne

Mayo Clinic

Orthopaedic Journal of Sports Medicine | September 2, 2020 | Volume: 8 | Issue: 9 | Pages: No page available

10.1177/2325967120939001 | PMID 32953920 Get It

Background: The retear rate after rotator cuff repair remains unacceptably high. Various biological engineered scaffolds have been proposed to reduce the retear rate. We have developed a double rip-stop repair with medial row knot (DRSK) technique to enhance suture-tendon strength and a novel engineered tendon-fibrocartilage-bone composite (TFBC) for rotator cuff repair. Hypothesis: DRSK rotator cuff repair augmented with TFBC will have better biomechanical properties than that of DRSK repair with an acellular dermal graft (DG). Study Design: Controlled laboratory study. Methods: Fresh-frozen canine shoulders (n = 30) and knees (n = 10) were used. TFBCs were harvested from the patellar tendon–tibia complex and prepared for rotator cuff repair. The infraspinatus tendon was sharply detached from its bony attachment and randomly assigned to the (1) control group: DRSK repair alone, (2) TFBC group: DRSK repair with TFBC, and (3) DG group: DRSK repair with DG. All specimens were tested to failure, and videos were recorded. The footprint area, tendon thickness, load to create 3-mm gap formation, failure load, failure modes, and stiffness were recorded and compared. Data were recorded as mean ± SD. Results: The mean load to create a 3-mm gap in both the control group (206.8 ± 55.7 N) and TFBC group (208.9 ± 39.1 N) was significantly higher than that in the DG group (157.7 ± 52.3 N) ( P < .05 for all). The failure load of the control group (275.7 ± 75.0 N) and TFBC group (275.2 ± 52.5 N) was significantly higher compared with the DG group (201.5 ± 49.7 N) ( P < .05 for both comparisons). The stiffness of the control group (26.4 ± 4.7 N/mm) was significantly higher than of the TFBC group (20.4 ± 4.4 N/mm) and the DG group (21.1 ± 4.8 N/mm) ( P < .05 for both comparisons). Conclusion: TFBC augmentation showed superior biomechanical performance to DG augmentation in rotator cuff tears repaired using the DRSK technique, while there was no difference between the TFBC and control groups. Clinical Relevance: TFBC may help to reduce retear or gap formation after rotator cuff repair using the DRSK technique.
Recent Advances in Ultrasound Diagnosis of Carpal Tunnel Syndrome
Yoshii, Yuichi , Zhao, Chunfeng , Amadio, Peter C.

Mayo Clinic

Diagnostics | August 17, 2020 | Volume: 10 | Issue: 8 | Pages: 596

10.3390/diagnostics10080596 | PMID 32824261 Get It

With the widespread use of high-resolution ultrasonography, ultrasonic examination has been shown to be useful as a diagnostic method for carpal tunnel syndrome. The main advantages of ultrasonography are that it is simple, quick, non-invasive, and economical. Another advantage is that tissue dynamics can be observed with real-time imaging. In recent reports, it has been shown that ultrasonic examination can provide similar diagnostic accuracy as nerve conduction study in the diagnosis of carpal tunnel syndrome. It has been expected that ultrasound demand in daily medical care will continue to increase. Ultrasonography in carpal tunnel syndrome shows an enlarged median nerve in proximal carpal tunnel, thickening of the flexor retinaculum, and edema around flexor tendons in cross-sectional images. In addition, with the introduction of new technologies such as ultrasonic elastography and speckle tracking, it has become possible to quantify dynamics and material property changes of nerves, tendons, and their surrounding structures. In this review, we describe recent advancements of carpal tunnel syndrome diagnosis based on ultrasound dynamic images, and discuss its pathology.
Biomechanical evaluation of a novel double rip-stop technique with medial row knots for rotator cuff repair
Wang, Zhanwen , Long, Zeling , Lin, Subin, Thoreson, Andrew R. , Moran, Steven L. , Gingery, Anne , Amadio, Peter C. , Steinmann, Scott P. , Zhao, Chunfeng , Li, Hong , Gingery, Anne , Li, Hong

Mayo Clinic

Bone & Joint Research | June 16, 2020 | Volume: 9 | Issue: 6 | Pages: 285-292

10.1302/2046-3758.96.bjr-2019-0196.r1 | PMID 32728429 Get It

AimsMany biomechanical studies have shown that the weakest biomechanical point of a rotator cuff repair is the suture-tendon interface at the medial row. We developed a novel double rip-stop (DRS) technique to enhance the strength at the medial row for rotator cuff repair. The objective of this study was to evaluate the biomechanical properties of the DRS technique with the conventional suture-bridge (SB) technique and to evaluate the biomechanical performance of the DRS technique with medial row knots.MethodsA total of 24 fresh-frozen porcine shoulders were used. The infraspinatus tendons were sharply dissected and randomly repaired by one of three techniques: SB repair (SB group), DRS repair (DRS group), and DRS with medial row knots repair (DRSK group). Specimens were tested to failure. In addition, 3 mm gap formation was measured and ultimate failure load, stiffness, and failure modes were recorded.ResultsThe mean load to create a 3 mm gap formation in the DRSK and DRS groups was significantly higher than in the SB group. The DRSK group had the highest load to failure with a mean ultimate failure load of 395.0 N (SD 56.8) compared to the SB and DRS groups, which recorded 147.1 N (SD 34.3) and 285.9 N (SD 89.8), respectively (p < 0.001 for both). The DRS group showed a significantly higher mean failure load than the SB group (p = 0.006). Both the DRS and DRSK groups showed significantly higher mean stiffness than the SB group.ConclusionThe biomechanical properties of the DRS technique were significantly improved compared to the SB technique. The DRS technique with medial row knots showed superior biomechanical performance than the DRS technique alone.
Sustained release of collagen‐affinity SDF‐1α from book‐shaped acellular fibrocartilage scaffold enhanced bone‐tendon healing in a rabbit model
Li, Muzhi , Chen, Yang , Shi, Qiang , Zhao, Chunfeng , Chen, Can , Lü, Hongbin , Lu, Hongbin , Chen, Yang , Hu, Jianzhong , Li, Xing

Mayo Clinic

Journal of Orthopaedic Research | April 10, 2020 | Volume: 39 | Issue: 6 | Pages: 1331-1343

10.1002/jor.24687 | PMID 32275087 Get It

AbstractRapid and functional bone‐tendon (B‐T) healing remains a difficulty in clinical practice. Tissue engineering has emerged as a promising strategy to address this problem. However, the majority of tissue engineering scaffolds are loaded with stem cells to enhance the regenerability in B‐T healing, which is complicated and inconvenient for clinical application. Accordingly, developing a cell‐free scaffold with chemotactic function and chondrogenic inducibility may be an effective approach. In this study, a collagen affinity peptide derived from the A3 domain of von Willebrand factor (a hemostasis factor) was fused into the C‐terminal of a stromal cell‐derived factor‐1α (SDF‐1α) to synthesize a recombinant SDF‐1α capable of binding collagen and chemotactic activity. The recombinant SDF‐1α was then tethered on the collagen fibers of a book‐shaped acellular fibrocartilage scaffold (BAFS), thus fabricating a novel scaffold (C‐SDF‐1α/BAFS) with chemotactic function and chondrogenic inducibility. In vitro tests determined that this scaffold was noncytotoxic and biomimetic, could attract stem cells migrating to the scaffold using sustainably released C‐SDF‐1α, and inducedthe interacting stem cells down the chondrogenic lineage. In vivo, the C‐SDF‐1α/BAFS significantly enhanced the B‐T healing in a rabbit partial patellectomy model, as shown by the larger cartilaginous metaplasia region, better fibrocartilage regeneration, additional bone formation, and improved biomechanical properties. Therefore, the findings of the study demonstrate that the C‐SDF‐1α/BAFS could potentially be applied for B‐T healing.
Characterization of a purified exosome product and its effects on canine flexor tenocyte biology
Qi, Jun , Liu, Qian , Reisdorf, Ramona L., Boroumand, Soulmaz, Behfar, Atta , Moran, Steven L. , Amadio, Peter C. , Gingery, Anne , Zhao, Chunfeng , Liu, Qian , Behfar, Atta , Gingery, Anne

Mayo Clinic

Journal of Orthopaedic Research | January 13, 2020 | Volume: 38 | Issue: 8 | Pages: 1845-1855

10.1002/jor.24587 | PMID 31930553 Get It

AbstractFlexor tendon injuries and tendinopathy are very common but remain challenging in clinical treatment. Exosomes‐based cell‐free therapy appears to be a promising strategy for tendon healing, while limited studies have evaluated its impacts on tenocyte biology. The objective of this study was to characterize a novel purified exosome product (PEP) derived from plasma, as well as to explore its cellular effects on canine tenocyte biology. The transmission electron microscope revealed that exosomes of PEP present cup‐shaped structures with the diameters ranged from 80 to 141 nm, and the NanoSight report presented that their size mainly concentrated around 100 nm. The enzyme‐linked immunosorbent assay kits analysis showed that PEP was positive for CD63 and AChE expression, and the cellular uptake of exosomes internalized into tenocyte cytoplasm was observed. The cell growth assays displayed that tenocyte proliferation ability was enhanced by PEP solution in a dose‐dependent manner. Tenogenic phenotype was preserved as is evident by that tendon‐related genes expression (SCX, COL1A, COL3A1, TNMD, DCN, and MKX) were expressed insistently in a high level, while tenocytes were treated with 5% PEP solution. Furthermore, migration capability was maintained and total collagen deposition was increased. More interesting, dexamethasone‐induced cellular apoptosis was attenuated during the incubation of tenocytes with a 5% PEP solution. These findings will provide the basic understandings about the PEP, and support the potential use of this biological strategy for tendon healing.
Human synoviocyte lubricin and bovine synovial fluid lubricin equally improve gliding resistance in a canine model in vitro
Kohn, Mark D. , Sun, Yu-Long, Zhao, Chunfeng , Thoreson, Andrew R. , Jay, Gregory D. , An, Kai‐Nan , Amadio, Peter C.

Mayo Clinic

Bio-Medical Materials and Engineering | December 2, 2019 | Volume: 21 | Issue: 5-6 | Pages: 281-289

10.3233/bme-2012-0676 | PMID 22561248 Get It

A Quick and Reliable Method to Decellularize a Gracilis Flap
Sabbagh, M. Diya , Roh, Si-Gyun, Liu, Junting , Morsy, Mohamed , Carlsen, Brian T. , Abu-Ghname, Amjed, Roh, Si‐Gyun , Abu‐Ghname, Amjed , Zhao, Chunfeng

Mayo Clinic

Annals of Plastic Surgery | November 12, 2019 | Volume: 83 | Issue: 6 | Pages: 709-715

10.1097/sap.0000000000002054 | PMID 31714296 Get It

Introduction Tissue loss as a consequence of congenital anomalies, trauma, malignancy, or gangrene represents a major health care problem in the United States. Because younger individuals are disproportionately affected, the costs are magnified over time and the resultant individual and societal effects are tremendous. The currently available options to restore soft tissue defects are associated with donor site morbidities. Vascularized composite allotransplantation may provide form, function, and esthetics without a donor site; however, it comes with the significant risk associated with toxic immunosuppression (Biomaterials. 2015;61:246-256, Ann Plast Surg. 2015;75(1):112-116, Transplantation. 2009;88(2):203-210). Engineered tissues offer promise in finding viable alternatives to allograft and autologous tissues. In this study, we present our simple and quick method to decellularize a muscle without disrupting the vascular network integrity or the extracellular matrix. Optimizing the decellularization process is a crucial step toward creating an “off-the-shelf” flap that can be used for soft tissue reconstruction. Methods The superficial gracilis muscle of 20 rats were harvested on their circulation and decellularized using perfusion with Krebs-Henseleit buffer and sodium dodecyl sulfate for 6 hours. These flaps were evaluated by gross morphology, histology, DNA quantification, integrity of the vascular network, scanning electron microscopy, and transmission electron microscopy. Results All samples were decellularized successfully as determined by DNA content and histological analysis for cellular content. The vascular network was preserved in all samples. Conclusions We present a quick, simple, and affordable method to decellularize a muscle flap through the vascular network. Our proposed method is efficient and can be completed in a significantly shorter time when compared with other methods. It is also safe and does not affect integrity of tissue, and this is essential for a reliable recellularization.