Citations

Clear

55 citation(s) found for "Rizzo, Marco".

Pyrolytic Carbon Arthroplasty versus Suspensionplasty for Trapezial-Metacarpal Arthritis
Rizzo, Marco , Moran, Steven L. , Vitale, Mark A. , Hsu, Chao‐Yu

Mayo Clinic

Journal of Wrist Surgery | October 14, 2016 | Volume: 06 | Issue: 02 | Pages: 134-143

10.1055/s-0036-1593735 | PMID 28428915 Get It

Total Wrist Arthroplasty Versus Wrist Fusion: Utilization and Complication Rates as Reported by ABOS Part II Candidates
Hinds, Richard M., Capo, John T., Rizzo, Marco , Roberson, James R., Gottschalk, Michael B.

Mayo Clinic

HAND | September 12, 2016 | Volume: 12 | Issue: 4 | Pages: 376-381

10.1177/1558944716668846 | PMID 28644942 Get It

Background: The aim of this study was to assess national trends in the utilization and complication rates of total wrist arthroplasty (TWA) and total wrist fusion (WF) as identified via review of the American Board of Orthopedic Surgery (ABOS) Part II candidate database. Methods: The ABOS Part II candidate database is a collection of cases reported by candidates of the ABOS Part II board certification oral exam. The ABOS database was queried for all TWA and WF cases performed from 2005 to 2014. Linear regression analyses were used to assess trends in procedure utilization. Treatment diagnoses, patient characteristics, and reported complications were also compared between the 2 treatment cohorts. Results: No significant increases in the proportion of candidates performing TWA or WF, number of TWA or WF cases, nor the number of TWA or WF cases performed per candidate performing those procedures were noted during the study period. Significantly less TWA cases were performed when compared with WF cases (68 vs 327; P = .006). Patients undergoing TWA were significantly older ( P = .005), more likely female ( P < .001), and more likely to have a diagnosis of osteoarthritis ( P = .003) than patients undergoing WF. There were no significant differences in complication rates, including postoperative infection, nerve palsy, or rate of secondary surgery, between the TWA and WF cohorts. Conclusions: Utilization of both TWA and WF has remained unchanged among emerging career orthopedic surgeons. Although WF is performed nearly 5 times more frequently than TWA, our short-term findings suggest that TWA compares favorably with WF.
Trends in the Utilization of Total Wrist Arthroplasty versus Wrist Fusion for Treatment of Advanced Wrist Arthritis
Marascalchi, Bryan J. , Hinds, Richard , Rizzo, Marco , Capo, John, Melamed, Eitan

Mayo Clinic

Journal of Wrist Surgery | February 9, 2016 | Volume: 05 | Issue: 03 | Pages: 211-216

10.1055/s-0036-1571841 | PMID 27468371 Get It

An Anatomic and Kinematic Analysis of a New Total Wrist Arthroplasty Design
Hooke, Alexander W. , Pettersson, Kurt, Sagerfors, Marcus , An, Kai‐Nan, Rizzo, Marco , Sagerfors, Marcus

Mayo Clinic

Journal of Wrist Surgery | April 23, 2015 | Volume: 04 | Issue: 02 | Pages: 121-127

10.1055/s-0035-1549288 | PMID 25945297 Get It

PATIENT RELATED FUNCTIONAL OUTCOME AFTER TOTAL WRIST ARTHROPLASTY: A SINGLE CENTER STUDY OF 206 CASES
Sagerfors, Marcus , Gupta, Anil , Brus, Ole, Rizzo, Marco , Pettersson, Kurt, Sagerfors, Marcus

Mayo Clinic

Hand Surgery | January 22, 2015 | Volume: 20 | Issue: 01 | Pages: 81-87

10.1142/s0218810415500112 | PMID 25609279 Get It

Objectives: To prospectively evaluate patient related outcome measures after total wrist arthroplasty (TWA) using four different total wrist implants operated at a single referral center in Sweden. Methods: 206 primary TWAs were assessed preoperatively and after one year postoperatively with respect to the following eight outcome measures: Range of motion (flexion/extension, radial/ulnar deviation, pronation/supination), hand grip strength, Canadian Occupational Performance Measure (COPM), performance and satisfaction, Visual Analog Scale (VAS) pain scores at rest and in activity. Results: The Maestro TWA had a significantly greater improvement of radial/ulnar deviation than the Biax and Remotion TWAs. COPM performance and satisfaction improved more for the Maestro and Universal 2 prostheses than the Biax and Remotion. Conclusions: All four TWAs offer reduced VAS-scores and improved COPM-scores with preserved hand grip strength and somewhat improved range of motion. The Maestro TWA performed favorably compared to the Remotion TWA. Implant design may affect patient related outcome.
Mycobacterium arupense Flexor Tenosynovitis: Case Report and Review of Antimicrobial Susceptibility Profiles for 40 Clinical Isolates
Beam, Elena , Vasoo, Shawn , Simner, Patricia J. , Rizzo, Marco , Mason, Erin L., Walker, Randall C., Deml, Sharon M., Brown‐Elliott, Barbara A. , Wallace, Richard J. , Wengenack, Nancy L. , Sia, Irene G. , Beam, Elena , Sia, Irene G

Mayo Clinic

Journal of Clinical Microbiology | May 1, 2014 | Volume: 52 | Issue: 7 | Pages: 2706-2708

10.1128/jcm.00277-14 | PMID 24789193 Get It

ABSTRACT We describe a case of chronic tenosynovitis in the hand of a 58-year-old cattle farmer. Surgical biopsy specimens grew Mycobacterium arupense . The patient responded to surgery and antimicrobial therapy based on in vitro susceptibility testing. The antimicrobial susceptibility profiles of the isolate from this patient and 39 additional clinical isolates are presented.
Pathogenesis and Treatment of Dupuytren Disease
Riester, Scott M. , Wijnen, André J. van , Rizzo, Marco , Riester, Scott, Kakar, Sanjeev , van Wijnen, Andre J

Mayo Clinic

JBJS Reviews | April 9, 2014 | Volume: 2 | Issue: 4 | Pages: No page available

10.2106/jbjs.rvw.m.00072 | PMID 27490872 Get It

Tenosynovitis of the Wrist and Thumb and Carpal Tunnel Syndrome Caused by Histoplasma Capsulatum : Case Report and Review of the Literature
Vitale, Mark A. , Roden, Anja C. , Rizzo, Marco

Mayo Clinic

HAND | February 17, 2014 | Volume: 10 | Issue: 1 | Pages: 54-59

10.1007/s11552-014-9611-4 | PMID 25762883 Get It

A patient presenting with acute carpal tunnel syndrome and swelling and pain in the wrist and thumb is presented. An open carpal tunnel release and tenosynovectomy were performed with biopsy specimen revealing infection with Histoplasma capsulatum. The case is discussed in context of the prior scant literature of tenosynovitis of the wrist and hand caused by histoplasmosis.
Reconstruction of Swan Neck Deformities after Proximal Interphalangeal Joint Arthroplasty
Froelich, John M., Rizzo, Marco

Mayo Clinic

HAND | December 9, 2013 | Volume: 9 | Issue: 1 | Pages: 93-98

10.1007/s11552-013-9571-0 | PMID 24570644 Get It

Background The authors report the use of a single slip of the flexor digitorum superficialis (FDS) as a hemitenodesis through the A2 pulley in treating swan neck deformities after previous unconstrained proximal interphalangeal joint (PIP) arthroplasty. Methods A retrospective chart review was undertaken to identify non-constrained PIP joint arthroplasties that underwent a subsequent soft tissue hemitenodesis for swan neck deformities. The range of motion (ROM), implant design, preoperative diagnosis, and surgical approach were collected. The Michigan Hand Outcomes Questionnaire and patient satisfaction questionnaire were collected. Results There were 12 patients with 14 procedures reviewed. There were seven surface replacement arthroplasties (SRA) (cobalt chrome on polyethylene) and eight pyrocarbon prostheses. The primary diagnosis for the initial joint arthroplasty was osteoarthritis (8), post-traumatic (2), and rheumatoid arthritis (5). The primary dorsal approach was a longitudinal split in eleven cases, Chamay in two, and unknown in one case. Nine of the 14 revision procedures had a concomitant dorsal approach to the joint. The average final position intra-operatively was 24.2° of flexion (range 15°–40°). Final ROM was 39° with average follow-up of 30 months. The average postoperative radiographic position was 20.3° flexion with an average of 24.8° hyperextension preoperatively. There was one failure secondary to implant loosening requiring fusion. Discussion For patients with a swan neck deformity after PIP arthroplasty, a FDS hemitenodesis provides a treatment option with a low revision rate, retained motion, and maintenance of the original implant with no shortening of the digit.
Total Wrist Replacement: A Retrospective Comparative Study
Cooney, William P., Manuel, Jennifer, Rizzo, Marco , Froelich, John M.

Mayo Clinic

Journal of Wrist Surgery | December 20, 2012 | Volume: 01 | Issue: 02 | Pages: 165-172

10.1055/s-0032-1326728 | PMID 24179722 Get It