Citations

Clear

142 citation(s) found for "Hsieh, TC".

(149) NEW FINDINGS REGARDING PERIOPERATIVE INFLATABLE PENILE PROSTHESIS ANTIMICROBIAL PROPHYLAXIS PATTERNS FROM A LARGE MULTINATIONAL COLLABORATION
Hammad, MAM, Gross, MS, Swerdloff, Daniel , Miller, Justin , Alkhayal, A, Alrabeeah, K, Andrianne, Robert, Burnett, AL, Gross, Kelli, Hatzichristodoulou, G, Lentz, A, Osmonov, Daniar , Jones, Adam , Modgil, Vaibhav , Perito, P, Hotaling, JM, Pearce, Ian , Sadeghi‐Nejad, Hossein , Sempels, Maxime, Suarez-Sarmiento, A, Warner, J, Ziegelmann, Matthew , Hsieh, TC, Simhan, Jay , Yafi, FA, collaborators, on behalf of the PUMP (Prosthetic Urology Multi-institutional Partnership), Barham, DW, Hammad, Muhammed , Azad, Babak Kazemzadeh , Chawareb, Elia Abou , Hatzichristodoulou, Georgios , Park, SH, Suarez‐Sarmiento, Alfredo, Renterghem, Koenraad van , Jenkins, Lawrence C. , Jones, James M. , collaborators, on behalf of the PUMP (Prosthetic Urology Multi-institutional Partnership), Barham, DW

Mayo Clinic

The Journal of Sexual Medicine | December 10, 2024 | Volume: 21 | Issue: Supplement_6 | Pages: No page available

10.1093/jsxmed/qdae161.121 Get It

Abstract Introduction Inflatable penile prosthesis (IPP) surgery is a well-established treatment for erectile dysfunction (ED). There is little information in the literature regarding the utilization of perioperative antimicrobial prophylaxis in primary and revision IPP surgeries. Objective We investigated the patterns of perioperative antimicrobial prophylaxis among a large multinational cohort of primary and revision IPP surgeries. Methods We conducted a retrospective analysis of 5400 patients (4187 primary IPP patients and 849 revision IPP patients) from our Prosthetic Urology Multi-Institutional Partnership (PUMP) institutions. Usage data for intravenous (IV), preoperative oral, and postoperative oral antimicrobials were analyzed. We specifically assessed patient profiles, antimicrobial selection, and antimicrobial duration. Multivariate statistical analyses were conducted to identify significant variations between primary and revision surgeries. Results For patients undergoing primary IPP placement, 81.9% received IV antibiotics for <24 hours whereas 18.1% received IV antibiotics for >24 hours. Preoperative oral antimicrobials were used in 59.4% of patients and 99.4% received postoperative oral antimicrobials. The overall infection rate for primary implants was 2%. Notably, quinolone administration shows a higher postoperative infection rate (11.4%) compared to gentamicin (1.9%), cephalosporin (0%), and vancomycin (1.0%). Multivariable regression analysis identifies factors such as a history of infection, diabetes, and priapism as predictors for postoperative infections. Furthermore, the study finds that perioperative antifungal use is associated with a decreased risk of infection. Conclusions This study provides valuable insights into the patterns of perioperative antimicrobial prophylaxis. Duration, type, and route of antibiotics given preoperatively or postoperatively do not affect postoperative infection rates among high volume prosthetic urologists. Giving IV antibiotics for more than 24 hours does not affect postoperative infection. Perioperative antifungals are a protective factor. Disclosure Any of the authors act as a consultant, employee or shareholder of an industry for: Coloplast, Clarus Therapeutics, Antares Pharma, Acerus.
Imaging performance of a LaBr3:Ce scintillation detector for photon counting x‐ray computed tomography: Simulation study
Goorden, Marlies C , Hsieh, Scott S. , Taguchi, Katsuyuki , Schaart, Dennis R.

Mayo Clinic

Medical Physics | October 3, 2024 | Volume: 52 | Issue: 1 | Pages: 158-170

10.1002/mp.17436 | PMID 39361516 Get It

AbstractBackgroundPhoton counting detectors (PCDs) for x‐ray computed tomography (CT) are the future of CT imaging. At present, semiconductor‐based PCDs such as cadmium telluride (CdTe), cadmium zinc telluride, and silicon have been either used or investigated for clinical PCD CT. Unfortunately, all of them have the same major challenges, namely high cost and limited spectral signal‐to‐noise ratio (SNR). Recent studies showed that some high‐quality scintillators, such as lanthanum bromide doped with cerium (LaBr3:Ce), are less expensive and almost as fast as CdTe.PurposeThe objective of this study is to assess the performance of a LaBr3:Ce PCD for clinical x‐ray CT.MethodsWe performed Monte Carlo simulations and compared the performance of 3 mm thick LaBr3:Ce and 2 mm thick CdTe for PCD CT with x‐rays at 120 kVp and 20–1000 mA. The two PCDs were operated with either a threshold–subtract (TS) counting scheme or a direct energy binning (DB) counting scheme. The performance was assessed in terms of the accuracy of registered spectra, counting capability, and count‐rate‐dependent spectral imaging‐task performance, for conventional CT imaging, water–bone material decomposition, and K‐edge imaging with tungsten as the K‐edge material. The performance for these imaging‐tasks was quantified by nCRLB, that is, the Cramér–Rao lower bound on the variance of basis line‐integral estimation, normalized by the corresponding value of CdTe at 20 mA.ResultsThe spectrum recorded by CdTe was distorted significantly due to charge sharing, whereas the spectra recorded by LaBr3:Ce better matched the incident spectrum. The dead time, estimated by fitting a paralyzable detector model to the count‐rate curves, was 20.7, 15.0, 37.2, and 13.0 ns for CdTe with TS, CdTe with DB, LaBr3:Ce with TS, and LaBr3:Ce with DB, respectively. Conventional CT imaging showed an adverse effect of reduced geometrical efficiency due to optical reflectors in LaBr3:Ce PCD. The nCRLBs (a lower value indicates a better SNR) for CdTe with TS, CdTe with DB, LaBr3:Ce with TS, LaBr3:Ce with DB, and the ideal PCD, were 1.00 ± 0.01, 1.00 ± 0.01, 1.18 ± 0.02, 1.18 ± 0.02, and 0.79 ± 0.01, respectively, at 20 mA. The nCRLBs for water–bone material decomposition, in the same order, were 1.00 ± 0.02, 1.00 ± 0.02, 0.85 ± 0.02, 0.85 ± 0.02, and 0.24 ± 0.02, respectively, at 20 mA; and 0.98 ± 0.02, 0.98 ± 0.02, 1.09 ± 0.02, 0.83 ± 0.02, and 0.24 ± 0.02, respectively, at 1000 mA. Finally, the nCRLBs for K‐edge imaging, the most demanding task among the five, were 1.00 ± 0.02, 1.00 ± 0.02, 0.55 ± 0.02, 0.55 ± 0.02, and 0.13 ± 0.02, respectively, at 20 mA; and 2.45 ± 0.02, 2.29 ± 0.02, 3.12 ± 0.02, 2.11 ± 0.02, and 0.13 ± 0.02, respectively, at 1,000 mA.ConclusionThe Monte Carlo simulations showed that, compared to CdTe with either TS or DB, LaBr3:Ce with DB provided more accurate spectra, comparable or better counting capability, and superior spectral imaging‐task performances, that is, water–bone material decomposition and K‐edge imaging. CdTe had a better performance than LaBr3:Ce for the conventional CT imaging task due to its higher geometrical efficiency. LaBr3:Ce PCD with DB scheme may be an excellent alternative option for CdTe PCD.
Asian Pacific Society of Cardiology Consensus Statements on the Use of Percutaneous Coronary Intervention on Stenosis of the Left Main Coronary Artery
Tan, Jack Wei Chieh , Tan, Huay Cheem , Lee, Michael , Seth, Ashok , Sin, Kenny YK, Firman, Doni , Yap, Jonathan , Sison, Eric Oliver D, Yahya, Achmad Fauzi , Chan, Kok Meng, Chan, Howard Ho Yan, Murasato, Yoshinobu , Malik, Fazila‐Tun‐Nesa , Nguyen, Michael C., Zhang, Bin , Kim, Hyo-Soo , Nguyen, Quang Ngoc , Ako, Junya , Bhindi, Ravinay, Zhang, Junjie , Tam, Frankie Chor-Cheung, Sengottuvelu, G., Ramaiah, Asri Ranga Bin Abdullah, Ali, Rosli Bin Mohd, Harding, S. , Wong, Aaron Sung Lung , Loh, Poay Huan , Hsieh, I-Chang , Kehasukcharoen, Wirash , Linh, Dinh Huynh, Henry, Timothy D. , Tan, Jack Wei Chieh , Lo, Sidney, Sin, Kenny Yoong Kong , Park, Duk‐Woo , Chan, Kok Meng John, Chan, Ho Yan Howard, Nguyen, Michael C, Lee, Kwan , Santoso, Teguh Iman , Wongpraparut, Nattawut , Ramaiah, Asri Ranga Abdullah, Yeo, Khung Keong , Stankovic, Goran R.

Mayo Clinic

Journal of Asian Pacific Society of Cardiology | October 2, 2024 | Volume: 3 | Issue: No issue available | Pages: No page available

10.15420/japsc.2024.27 Get It

Stenosis of the left main coronary artery (LM stenosis) is associated with significant mortality and morbidity due to the large area of affected myocardium. Evidence on the use of percutaneous coronary intervention (PCI) for the treatment of LM stenosis is growing. However, the role of Western guidelines on patients in the Asian-Pacific region is unclear due to anatomical variations, substantial heterogeneity in healthcare resources and infrastructure, and the lack of consensus on the optimal management of LM stenosis in the Asia-Pacific region. Hence, an Asian Pacific Society of Cardiology (APSC) working group developed consensus recommendations on the use of PCI in the management of LM stenosis in the Asia-Pacific region. The APSC expert panel reviewed and appraised the available evidence using the Grading of Recommendations Assessment, Development, and Evaluation system. Consensus recommendations were developed and put to an online vote. Consensus was reached when 80% of votes for a given recommendation were in support of ‘agree’ or ‘neutral’. The resulting 12 statements provide guidance for clinical practitioners in the region on the use of PCI in the treatment of patients with LM stenosis.
Performance of scintillator-based detectors for photon counting x-ray computed tomography
Goorden, Marlies C , Taguchi, Katsuyuki , Schaart, Dennis R. , Hsieh, S.

Mayo Clinic

2024 IEEE Nuclear Science Symposium (NSS), Medical Imaging Conference (MIC) and Room Temperature Semiconductor Detector Conferen | September 25, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-1

10.1109/nss/mic/rtsd57108.2024.10656151 Get It

Loss‐of‐Function Variants in CUL3 Cause a Syndromic Neurodevelopmental Disorder
Blackburn, Patrick R. , Herkert, Johanna C. , Rinne, Tuula , Thiffault, Isabelle, Rapp, Michele, Alders, Mariel, Maas, Saskia M. , Gérard, Bénédicte, Smol, Thomas , Vincent‐Delorme, Catherine , Isidor, Bertrand , Joset, Pascal , Husson, Thomas , Guerrot, Anne‐Marie , Bacino, Carlos A. , Macmurdo, Colleen, Thompson, Stephanie S., Faivre, Laurence , Deb, Wallid , Vignard, Virginie , Goldenberg, Alice, Lecoquierre, François , Zech, Michael , Necpál, Ján , Winkelmann, Juliane , Koprušáková, Monika Turčanová , Konstantopoulou, Vassiliki , Younce, John R. , Mighton, Chloe, Fung, Charlotte, Morel, Chantal F. , Barth, Magalie , Krapels, Ingrid P.C. , Schoot, Vyne van der , Bußmann, Cornelia, Wortmann, Saskia B. , Ravelli, Claudia , Keren, Boris , Ziegler, Alban , Hasadsri, Linda , Pichurin, Pavel N. , Klee, Eric W. , Grand, Katheryn , Sanchez‐Lara, Pedro A. , Krüger, Elke , Klinkhammer, Hannah , Tartaglia, Marco , Wang, Tianyun , Prokisch, Holger , Shinawi, Marwan , Brunet, Theresa , Tartaglia, Marco , Wang, Tianyun , Lecoquierre, Francois , Faivre, Laurence , Ebstein, Frédéric , Hsieh, Tzung‐Chien , Motta, Marialetizia , Radio, Francesca Clementina , Cogné, Benjamin , Vincent, Marie , Bachmann‐Gagescu, Ruxandra , Rauch, Anita , Ferrero, Giovanni Battista , Ciolfi, Andrea , Rosenfeld, Jill A. , Mau‐Them, Frédéric Tran , Agrawal, Pankaj B. , Madden, Jill A. , Goldenberg, Alice , Jech, Robert , Shinawi, Marwan , Lerner‐Ellis, Jordan P. , DiTroia, Stephanie P. , Bonneau, Dominique , Stegmann, Alexander P.A. , Mignot, Cyril , Zampino, Giuseppe , Mayr, Johannes A , Feichtinger, René G. , Courtin, Thomas , Bezieau, Stéphane , Krawitz, Peter Michael , Eichler, Evan E , Küry, Sébastien

Mayo Clinic

Annals of Neurology | September 20, 2024 | Volume: 97 | Issue: 1 | Pages: 76-89

10.1002/ana.27077 | PMID 39301775 Get It

ObjectiveDe novo variants in cullin‐3 ubiquitin ligase (CUL3) have been strongly associated with neurodevelopmental disorders (NDDs), but no large case series have been reported so far. Here, we aimed to collect sporadic cases carrying rare variants in CUL3, describe the genotype–phenotype correlation, and investigate the underlying pathogenic mechanism.MethodsGenetic data and detailed clinical records were collected via multicenter collaboration. Dysmorphic facial features were analyzed using GestaltMatcher. Variant effects on CUL3 protein stability were assessed using patient‐derived T‐cells.ResultsWe assembled a cohort of 37 individuals with heterozygous CUL3 variants presenting a syndromic NDD characterized by intellectual disability with or without autistic features. Of these, 35 have loss‐of‐function (LoF) and 2 have missense variants. CUL3 LoF variants in patients may affect protein stability leading to perturbations in protein homeostasis, as evidenced by decreased ubiquitin‐protein conjugates in vitro. Notably, we show that 4E‐BP1 (EIF4EBP1), a prominent substrate of CUL3, fails to be targeted for proteasomal degradation in patient‐derived cells.InterpretationOur study further refines the clinical and mutational spectrum of CUL3‐associated NDDs, expands the spectrum of cullin RING E3 ligase‐associated neuropsychiatric disorders, and suggests haploinsufficiency via LoF variants is the predominant pathogenic mechanism. ANN NEUROL 2025;97:76–89
Existence, uniqueness, and efficiency of numerically unbiased attenuation pathlength estimators for photon counting detectors at low count rates
Hsieh, Scott S. , Rajbhandary, Paurakh L.

Mayo Clinic

Medical Physics | September 17, 2024 | Volume: 51 | Issue: 12 | Pages: 8742-8750

10.1002/mp.17406 | PMID 39287477 Get It

AbstractBackgroundThe first step in computed tomography (CT) reconstruction is to estimate attenuation pathlength. Usually, this is done with a logarithm transformation, which is the direct solution to the Beer‐Lambert Law. At low signals, however, the logarithm estimator is biased. Bias arises both from the curvature of the logarithm and from the possibility of detecting zero counts, so a data substitution strategy may be employed to avoid the singularity of the logarithm. Recent progress has been made by Li et al. [IEEE Trans Med Img 42:6, 2023] to modify the logarithm estimator to eliminate curvature bias, but the optimal strategy for mitigating bias from the singularity remains unknown.PurposeThe purpose of this study was to use numerical techniques to construct unbiased attenuation pathlength estimators that are alternatives to the logarithm estimator, and to study the uniqueness and optimality of possible solutions, assuming a photon counting detector.MethodsFormally, an attenuation pathlength estimator is a mapping from integer detector counts to real pathlength values. We constrain our focus to only the small signal inputs that are problematic for the logarithm estimator, which we define as inputs of <100 counts, and we consider estimators that use only a single input and that are not informed by adjacent measurements (e.g., adaptive smoothing). The set of all possible pathlength estimators can then be represented as points in a 100‐dimensional vector space. Within this vector space, we use optimization to select the estimator that (1) minimizes mean squared error and (2) is unbiased. We define “unbiased” as satisfying the numerical condition that the maximum bias be less than 0.001 across a continuum of 1000 object thicknesses that span the desired operating range. Because the objective function is convex and the constraints are affine, optimization is tractable and guaranteed to converge to the global minimum. We further examine the nullspace of the constraint matrix to understand the uniqueness of possible solutions, and we compare the results to the Cramér‐Rao bound of the variance.ResultsWe first show that an unbiased attenuation pathlength estimator does not exist if very low mean detector signals (equivalently, very thick objects) are permitted. It is necessary to select a minimum mean detector signal for which unbiased behavior is desired. If we select two counts, the optimal estimator is similar to Li's estimator. If we select one count, the optimal estimator becomes non‐monotonic. The oscillations cause the unbiased estimator to be noise amplifying. The nullspace of the constraint matrix is high‐dimensional, so that unbiased solutions are not unique. The Cramér‐Rao bound of the variance matches well with the expected scaling law and cannot be attained.ConclusionIf arbitrarily thick objects are permitted, an unbiased attenuation pathlength estimator does not exist. If the maximum thickness is restricted, an unbiased estimator exists but is not unique. An optimal estimator can be selected that minimizes variance, but a bias‐variance tradeoff exists where a larger domain of unbiased behavior requires increased variance.
Outcomes of mechanical thrombectomy in anticoagulated patients with acute distal and medium vessel stroke
Salim, Hamza , Musmar, Basel , Adeeb, Nimer , Yedavalli, Vivek , Lakhani, Dhairya A. , Grewal, Sahibjot , Henninger, Nils , Sundararajan, Sri Hari , Khalife, Jane , Tan, Benjamin Yong‐Qiang , Regenhardt, Robert W. , Heit, Jeremy J. , Cancelliere, Nicole M , Rouchaud, Aymeric , Sheth, Sunil G. , Puri, Ajit S , Dyzmann, Christian , Colasurdo, Marco , Barreau, Xavier , Filipe, João Pedro , Abdalkader, Mohamad , Marotta, Thomas R. , Spears, Julian , Biswas, Arundhati , Clarençon, Frédéric , Varela, Ricardo , Baker, Amanda , Essibayi, Muhammed Amir , Altschul, David , Gonzalez, Nestor R. , Möhlenbruch, Markus , Costalat, Vincent , Gory, Benjamin , Stracke, Christian Paul , Shaikh, Hamza , Liebeskind, David S. , Alexandre, Andrea , Tancredi, Illario , Faizy, Tobias D. , Kalsoum, Erwah , Lubicz, Boris , Patel, Aman B. , Guenego, Adrien , Investigators, for the MAD MT, Valente, Iacopo , Hsieh, Cheng‐Yang , Lakhani, Dhairya , Scarcia, Luca , Regenhardt, Robert W , Fiehler, Jens , Alexandru Radu, Răzvan , Klein, Piers , Ota, Takahiro , Jabbour, Pascal , Nguyen, Thanh N , Essibayi, Muhammed Amir , Gonzalez, Nestor R , Möhlenbruch, Markus A , Liebeskind, David S. , Heit, Jeremy J , Altschul, David J , Musmar, Basel , Salim, Hamza , Yedavalli, Vivek S , Cancelliere, Nicole M , Rouchaud, Aymeric , Colasurdo, Marco , Henninger, Nils , Tan, Benjamin Yq , Alexandre, Andrea M , Varela, Ricardo , Naamani, Kareem El , Kühn, Anna Luisa , Ghozy, Sherief , Bernstock, Joshua D. , Fiehler, Jens , Sheth, Sunil, Renieri, Leonardo , Harker, Pablo , Radu, Răzvan Alexandru , Klein, Piers , Mowla, Ashkan , Jabbour, Pascal , Siegler, James E. , Nguyen, Thanh N. , Baker, Amanda, Aziz‐Sultan, Mohammad Ali , Hecker, Constantin , Pedicelli, Alessandro , Mendes Pereira, Vitor , Dmytriw, Adam A.

Mayo Clinic

European Stroke Journal | May 10, 2024 | Volume: 9 | Issue: 4 | Pages: 896-906

10.1177/23969873241249295 | PMID 38726983 Get It

Abstract Background: Stroke remains a major health concern globally, with oral anticoagulants widely prescribed for stroke prevention. The efficacy and safety of mechanical thrombectomy (MT) in anticoagulated patients with distal medium vessel occlusions (DMVO) are not well understood. Methods: This retrospective analysis involved 1282 acute ischemic stroke (AIS) patients who underwent MT in 37 centers across North America, Asia, and Europe from September 2017 to July 2023. Data on demographics, clinical presentation, treatment specifics, and outcomes were collected. The primary outcomes were functional outcomes at 90 days post-MT, measured by modified Rankin Scale (mRS) scores. Secondary outcomes included reperfusion rates, mortality, and hemorrhagic complications. Results: Of the patients, 223 (34%) were on anticoagulation therapy. Anticoagulated patients were older (median age 78 vs 74 years; p &lt; 0.001) and had a higher prevalence of atrial fibrillation (77% vs 26%; p &lt; 0.001). Their baseline National Institutes of Health Stroke Scale (NIHSS) scores were also higher (median 12 vs 9; p = 0.002). Before propensity score matching (PSM), anticoagulated patients had similar rates of favorable 90-day outcomes (mRS 0–1: 30% vs 37%, p = 0.1; mRS 0–2: 47% vs 50%, p = 0.41) but higher mortality (26% vs 17%, p = 0.008). After PSM, there were no significant differences in outcomes between the two groups. Conclusion: Anticoagulated patients undergoing MT for AIS due to DMVO did not show significant differences in 90-day mRS outcomes, reperfusion, or hemorrhage compared to non-anticoagulated patients after adjustment for covariates.
Stripping versus ligation of vas deferens in microscopic denervation of spermatic cord in men with chronic orchialgia: A multicenter study
El‐Achkar, Adnan , Hammad, Muhammed , Barham, David , Service, C Austin, Hsieh, Tung- Chin, Mills, Jesse N. , Ziegelmann, Matthew , Smith, Ryan P. , Bernie, Helen L. , Egert, Melissa , Gross, Kelli, Pastuszak, Alex, Hotaling, James M. , Yafi, Faysal A. , Hammad, Muhammed A M , Patel, Darshan P. , Kianian, Reza , Eleswarapu, Sriram Venkata , Bryk, Darren J. , Raheem, Omer A. , Fendereski, Kiarad

Mayo Clinic

Andrology | April 19, 2024 | Volume: 13 | Issue: 2 | Pages: 268-274

10.1111/andr.13650 | PMID 38639020 Get It

AbstractBackgroundMicrodenervation of the spermatic cord (MSCD) is an effective treatment modality for men with intractable scrotal content pain. For patients not interested in preserving fertility, some centers advocate ligation of the vas during denervation, while others prefer stripping of the vas deferens to preserve the vasal artery, hence preserving vasculature to the testis and possibly decreasing post‐operative congestion pain.ObjectiveTo compare outcomes of patients with chronic orchialgia, who underwent MSCD by either stripping or ligating the vas deferens.Materials and methodsA retrospective chart review of 85 patients who underwent MSCD from 2017–2023 was performed. Patients’ demographics including history of prior surgical procedures were recorded. Response to surgery was evaluated as either complete resolution of pain, partial resolution of pain, or no improvement in pain.ResultsEighty‐five patients underwent MSCD with a median (interquartile range, IQR) age of 36 (25.5–46.5) years and median duration of pain of 16 (6–31) months. Thirty‐seven patients underwent stripping of vas, while 48 underwent ligation of vas during MSCD. Median follow up was 12 months. Twenty‐one (43.5%) patients had prior inguinal scrotal surgery in the ligation group compared to 5 (13.5%) in the stripping group, p = 0.003. The etiology of pain was similar between the groups. The response to MSCD between the two groups was similar, 67.6% of patients who underwent stripping had complete resolution of pain versus 66.7% of those who had ligation (p = 0.968), with similar rates of post‐operative complications (p‐value = 0.132).ConclusionsIn men with intractable chronic scrotal content pain with no interest in preserving fertility, ligation, or stripping of the vas deferens yields similar outcomes with regard to pain resolution. Both techniques are safe with no reports of any testicular atrophy.
3D printed phantom with 12 000 submillimeter lesions to improve efficiency in CT detectability assessment
Shunhavanich, Picha , Shapira, Nadav , Gang, Grace J. , Geagan, Michael, Yu, Lifeng , Noël, Peter B. , Hsieh, Scott S. , Mei, Kai , Stayman, Joseph Webster , McCollough, Cynthia H. , Leng, Shuai , Yu, Lifeng

Mayo Clinic

Medical Physics | April 8, 2024 | Volume: 51 | Issue: 5 | Pages: 3265-3274

10.1002/mp.17064 | PMID 38588491 Get It

AbstractBackgroundThe detectability performance of a CT scanner is difficult to precisely quantify when nonlinearities are present in reconstruction. An efficient detectability assessment method that is sensitive to small effects of dose and scanner settings is desirable. We previously proposed a method using a search challenge instrument: a phantom is embedded with hundreds of lesions at random locations, and a model observer is used to detect lesions. Preliminary tests in simulation and a prototype showed promising results.PurposeIn this work, we fabricated a full‐size search challenge phantom with design updates, including changes to lesion size, contrast, and number, and studied our implementation by comparing the lesion detectability from a nonprewhitening (NPW) model observer between different reconstructions at different exposure levels, and by estimating the instrument sensitivity to detect changes in dose.MethodsDesigned to fit into QRM anthropomorphic phantoms, our search challenge phantom is a cylindrical insert 10 cm wide and 4 cm thick, embedded with 12 000 lesions (nominal width of 0.6 mm, height of 0.8 mm, and contrast of −350 HU), and was fabricated using PixelPrint, a 3D printing technique. The insert was scanned alone at a high dose to assess printing accuracy. To evaluate lesion detectability, the insert was placed in a QRM thorax phantom and scanned from 50 to 625 mAs with increments of 25 mAs, once per exposure level, and the average of all exposure levels was used as high‐dose reference. Scans were reconstructed with three different settings: filtered‐backprojection (FBP) with Br40 and Br59, and Sinogram Affirmed Iterative Reconstruction (SAFIRE) with strength level 5 and Br59 kernel. An NPW model observer was used to search for lesions, and detection performance of different settings were compared using area under the exponential transform of free response ROC curve (AUC). Using propagation of uncertainty, the sensitivity to changes in dose was estimated by the percent change in exposure due to one standard deviation of AUC, measured from 5 repeat scans at 100, 200, 300, and 400 mAs.ResultsThe printed insert lesions had an average position error of 0.20 mm compared to printing reference. As the exposure level increases from 50 mAs to 625 mAs, the lesion detectability AUCs increase from 0.38 to 0.92, 0.42 to 0.98, and 0.41 to 0.97 for FBP Br40, FBP Br59, and SAFIRE Br59, respectively, with a lower rate of increase at higher exposure level. FBP Br59 performed best with AUC 0.01 higher than SAFIRE Br59 on average and 0.07 higher than FBP Br40 (all P < 0.001). The standard deviation of AUC was less than 0.006, and the sensitivity to detect changes in mAs was within 2% for FBP Br59.ConclusionsOur 3D‐printed search challenge phantom with 12 000 submillimeter lesions, together with an NPW model observer, provide an efficient CT detectability assessment method that is sensitive to subtle effects in reconstruction and is sensitive to small changes in dose.