Citations

Clear

7554 citation(s) found for "Ku, Matthew".

Can the Severe Acute Respiratory Syndrome Coronavirus 2 Polymerase Chain Reaction Cycle Threshold Value and Time From Symptom Onset to Testing Predict Infectivity?
Binnicker, Matthew J.

Mayo Clinic

Clinical Infectious Diseases | June 4, 2020 | Volume: 71 | Issue: 10 | Pages: 2667-2668

10.1093/cid/ciaa735 | PMID 32504529 Get It

Perioperative Opioid Use Predicts Postoperative Opioid Use and Inferior Outcomes After Shoulder Arthroscopy
Lu, Yining , Beletsky, Alexander , Patel, Bhavik H. , Cancienne, Jourdan M. , Nemsick, Michael , Skallerud, William K., Yanke, Adam B. , Verma, Nikhil N. , Cole, Brian J. , Lu, Yining , Cohn, Matthew R. , Forsythe, Brian

Mayo Clinic

Arthroscopy | June 4, 2020 | Volume: 36 | Issue: 10 | Pages: 2645-2654

10.1016/j.arthro.2020.05.044 | PMID 32505708 Get It

Purpose The purpose of this study is to define the impact of preoperative opioid use on postoperative opioid use, patient‐reported outcomes, and revision rates in a cohort of patients receiving arthroscopic shoulder surgery. Methods Patients who underwent shoulder arthroscopy were identified from an institutional database. Inclusion criteria were completion of preoperative and postoperative patient‐reported outcome measures (PROMs) at 1‐year follow‐up and completion of a questionnaire on use of opioids and number of pills per day. Outcomes assessed included postoperative PROM scores, postoperative opioid use, persistent pain, and achievement of the patient acceptable symptomatic state. A matched cohort analysis was performed to evaluate the impact of opioid use on achievement of postoperative outcomes, whereas a multivariate regression was performed to determine additional risk factors. Receiver operating characteristic curves were used to establish threshold values in oral morphine equivalents (OMEs) that predicted each outcome. Results A total of 184 (16.3%) patients were included in the opioid use (OU) group and 1,058 in the no opioid use (NOU) group. The OU and NOU groups showed statistically significant differences in both preoperative and postoperative scores across all PROMs ( P < .001). Multivariate logistic regression identified preoperative opioid use as a significant predictor of reduced achievement of the patient acceptable symptomatic state (odds ratio [OR], 0.69, 95% confidence interval [CI], 0.29‐0.83, P = .008), increased likelihood of endorsing persistent pain (OR, 1.73, 95% CI, 1.17‐2.56, P = .006), and increased opioid use at 1 year (OR, 21.3, 95% CI, 12.2‐37.2, P < .001). Consuming a high dosage during the perioperative period increased risk of revision surgery (OR, 8.59, 95% CI, 2.12‐34.78, P < .003). Results were confirmed by matched cohort analysis. Receiver operating characteristic analysis found that total OME >1430 mg/d in the perioperative period (area under the curve, 0.76) and perioperative daily OME >32.5 predicted postoperative opioid consumption (area under the curve, 0.79). Conclusions Patients with a history of preoperative opioid use can achieve significant improvements in patient‐reported outcomes after arthroscopic shoulder surgery. However, preoperative opioid use negatively impacts patients’ level of satisfaction and is a significant predictor of pain and continued opioid usage. Level of evidence Level III, retrospective cohort study
Electrocochleography in cochlear implantation: Development, applications, and future directions
Barnes, Jason H. , Saoji, Aniket A. , Carlson, Matthew L. , Yin, Linda X.

Mayo Clinic

World Journal of Otorhinolaryngology - Head and Neck Surgery | June 4, 2020 | Volume: 7 | Issue: 2 | Pages: 94-100

10.1016/j.wjorl.2020.04.006 | PMID 33997718 Get It

Electrocochleography (ECochG) is an electrophysiological technique that records electrical potentials generated by different components of the inner ear and peripheral cochlear nerve in response to acoustic stimulation. ECochG responses can be analyzed into (1) cochlear microphonics (CM), (2) auditory nerve neurophonics, (3) summating potential, and (4) compound action potential. Over the past few decades, there have been ongoing refinements in technique and updates in the understanding of recorded potentials. Historically, ECochG found its main application in the diagnostic evaluation of Meniere's disease (MD). However, in the last decade, the focus has shifted towards cochlear implantation (CI). In patients with residual hearing after CI, combined electric and acoustic stimulation has resulted in improved hearing and speech outcomes. Despite efforts to mitigate trauma during electrode insertion, hearing preservation rates vary after surgery. During implantation, real‐time ECochG offers an opportunity to measure frequency specific CMs elicited from a localized region in the cochlea as the surgeon inserts the electrode array. In extracochlear ECochG recordings, the recording electrode can be placed on the promontory, the stapes, or the tympanic membrane. Intracochlear ECochG can be performed by inserting a recording electrode into the cochlea or by using one of the CI electrodes as the recording electrode. The loss of intraoperative ECochG signal may indicate cochlear trauma from electrode insertion, but the association between intraoperative ECochG changes and cochlear trauma remains controversial. The ability to monitor cochlear trauma during CI electrode placement holds promise to improve hearing preservation outcomes, modify surgical techniques, and change electrode design. The goal of this review is to provide a comprehensive overview of the electrophysiology and history of ECochG, discuss its recent applications in CI, and explore the ongoing research in this expanding field.
Long-term Outcomes of MCP Surface Replacement Arthroplasty in Patients With Rheumatoid Arthritis
Mohney, Brian G. , Rizzo, Marco , Claxton, Matthew R , Rizzo, Marco , Wagner, Eric R.

Mayo Clinic

HAND | June 3, 2020 | Volume: 17 | Issue: 2 | Pages: 271-277

10.1177/1558944720926631 | PMID 32486855 Get It

Background: Surface replacement arthroplasty (SRA) can be used in the treatment of rheumatoid arthritis (RA) affecting the metacarpophalangeal (MCP) joint. The authors of this study sought to investigate the outcomes of MCP SRA in patients with RA. Methods: Retrospective review of medical records and an institutional joint registry were used to gather data on 80 MCP SRAs performed in 27 patients with RA. Data collected included demographics, SRA revisions, reoperations, complications, pain, and MCP arc of motion. Results: The mean postoperative follow-up was 9.5 years (range, 2.1-20.5 years), with all SRAs achieving at least 2 years of follow-up. Thirteen digits (16%) underwent revision arthroplasty, and 29 (36%) required reoperation. The 5-, 10-, 15-, and 20-year rates of survival from implant revision were 95%, 85%, 80%, and 69%, respectively. The 5-, 10-, 15-, and 20-year rates of survival from overall reoperation were 80%, 65%, 55%, and 46%, respectively. Metacarpophalangeal joint arc of motion, grip strength, and pain levels significantly improved following surgery. Conclusions: Metacarpophalangeal SRA can offer benefit to patients with RA for improvement in function and pain. High overall reoperation rates remain concerning; however, most do not involve arthroplasty revision.
Comparative analysis of 23 synovial fluid biomarkers for hip and knee periprosthetic joint infection detection
Sharma, Katyayini , Ivy, Morgan I. , Block, Darci R , Abdel, Matthew P. , Hanssen, Arlen D. , Beauchamp, Christopher , Perry, Kevin I. , Rosemark, Christopher L., Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jay , Patel, Robin , Ivy, Morgan, Patel, Robin , Abdel, Matthew P

Mayo Clinic

Journal of Orthopaedic Research | June 2, 2020 | Volume: 38 | Issue: 12 | Pages: 2664-2674

10.1002/jor.24766 | PMID 32485031 Get It

AbstractThere is interest in novel synovial fluid biomarkers for the detection of periprosthetic joint infection (PJI). Here, we assessed the diagnostic accuracy of 23 simple or sophisticated synovial fluid biomarkers for periprosthetic hip or knee infection detection. One hundred seven subjects were studied, 57 of whom had aseptic failure (AF) and 50 PJI. The following synovial fluid biomarkers were tested using spectrophotometric assays, immunoassays, lateral flow tests, or test strips: leukocyte count, monocyte percentage, lymphocyte percentage, neutrophil percentage, C‐reactive protein (CRP), glucose, lactate, granulocyte‐macrophage colony‐stimulating factor, interferon‐γ, interleukin‐1β (IL‐1β), IL‐2, IL‐4, IL‐5, IL‐6, IL‐8, IL‐10, IL‐12p70, IL‐13, IL‐17A, IL‐23, tumor necrosis factor‐α, α‐defensin, and leukocyte esterase. The best‐performing synovial fluid biomarkers to differentiate PJI from AF—that is, those with highest area under the curve compared to all other biomarkers—were leukocyte count, percent neutrophils and percent monocytes, CRP, and α‐defensin (P < .0001).
Etiology of Papilledema in Patients in the Eye Clinic Setting
Crum, Olivia M. , Kilgore, Khin P. , Spiegel, Matthew R. , Bhatti, M. Tariq , Chen, John J. , Chen, John J , Sharma, Rishi , Lee, Michael S. , McClelland, Collin M.

Mayo Clinic

JAMA Network Open | June 2, 2020 | Volume: 3 | Issue: 6 | Pages: e206625

10.1001/jamanetworkopen.2020.6625 | PMID 32484553 Get It

Phage Therapy for Limb-threatening Prosthetic Knee Klebsiella pneumoniae Infection: Case Report and In Vitro Characterization of Anti-biofilm Activity
Caflisch, Katherine M., Patel, Robin , Fackler, Joseph , Brownstein, Michael, Horne, Bri’Anna , Biswas, Biswajit , Henry, Matthew, Malagón, Francisco , Lewallen, David G. , Cano, Edison J, Patel, Robin , Cevallos, Edison Cano , Bollyky, Paul L. , Belleghem, Jonas D. Van , Suh, Gina A.

Mayo Clinic

Clinical Infectious Diseases | June 1, 2020 | Volume: 73 | Issue: 1 | Pages: e144-e151

10.1093/cid/ciaa705 | PMID 32699879 Get It

Abstract Background Prosthetic joint infection (PJI) is a potentially limb-threatening complication of total knee arthroplasty. Phage therapy is a promising strategy to manage such infections including those involving antibiotic-resistant microbes, and to target microbial biofilms. Experience with phage therapy for infections associated with retained hardware is limited. A 62-year-old diabetic man with a history of right total knee arthroplasty 11 years prior who had suffered multiple episodes of prosthetic knee infection despite numerous surgeries and prolonged courses of antibiotics, with progressive clinical worsening and development of severe allergies to antibiotics, had been offered limb amputation for persistent right prosthetic knee infection due to Klebsiella pneumoniae complex. Intravenous phage therapy was initiated as a limb-salvaging intervention. Methods The patient received 40 intravenous doses of a single phage (KpJH46Φ2) targeting his bacterial isolate, alongside continued minocycline (which he had been receiving when he developed increasing pain, swelling, and erythema prior to initiation of phage therapy). Serial cytokine and biomarker measurements were performed before, during, and after treatment. The in vitro anti-biofilm activity of KpJH46Φ2, minocycline and the combination thereof was evaluated against a preformed biofilm of the patient’s isolate and determined by safranin staining. Results Phage therapy resulted in resolution of local symptoms and signs of infection and recovery of function. The patient did not experience treatment-related adverse effects and remained asymptomatic 34 weeks after completing treatment while still receiving minocycline. A trend in biofilm biomass reduction was noted 22 hours after exposure to KpJH46Φ2 (P = .063). The addition of phage was associated with a satisfactory outcome in this case of intractable biofilm-associated prosthetic knee infection. Pending further studies to assess its efficacy and safety, phage therapy holds promise for treatment of device-associated infections.
Antimicrobial properties of antibiotic-loaded implants
Griseti, Quentin, Jacquet, Christophe , Sautet, Pierre, Parratte, Sébastien , Ollivier, Matthieu , Abdel, Matthew P. , Argenson, Jean‐Noël

Mayo Clinic

The Bone & Joint Journal | May 31, 2020 | Volume: 102-B | Issue: 6_Supple_A | Pages: 158-162

10.1302/0301-620x.102b6.bjj-2019-1636.r1 | PMID 32475268 Get It

Aims The aim of this study was to compare the ability of tantalum, 3D porous titanium, antibiotic-loaded bone cement, and smooth titanium alloy to inhibit staphylococci in an in vitro environment, based on the evaluation of the zone of inhibition (ZOI). The hypothesis was that there would be no significant difference in the inhibition of methicillin-sensitive or methicillin-resistant Staphylococcus aureus (MSSA/MRSA) between the two groups. Methods A total of 30 beads made of three different materials (tantalum/3D porous titanium and smooth titanium alloy) were bathed for one hour in a solution of 1 g vancomycin in 20 ml of sterile water for injection (bath concentration: 50 mg/mL). Ten 1 cm3 cylinders of antibiotic-loaded cement were also created by mixing standard surgical cement with 1 g of vancomycin in standardized sterile moulds. The cylinders were then placed on agar plates inoculated with MSSA and MRSA. The ZOIs were measured each day and the cylinders were transferred onto a new inoculated plate. Results For MSSA and MRSA, no inhibitory effect was found in the control group, and antibiotic-loaded smooth titanium alloy beads showed a short inhibitory effect until day 2. For MSSA, both tantalum and 3D porous titanium beads showed significantly larger mean ZOIs than cement beads (all p < 0.01) each day until day 7 for tantalum and until day 3 for 3D porous titanium. After six days, antibiotic-loaded cement had significantly larger mean ZOIs than the 3D porous titanium (p = 0.027), but no significant difference was found with tantalum (p = 0.082). For MRSA, both tantalum and 3D porous titanium beads had significantly larger mean ZOIs than antibiotic-loaded cement each day until day 6 for tantalum (all p < 0.01) and until day 3 for 3D porous titanium (all p < 0.04). Antibiotic-loaded cement had significantly larger mean ZOIs than tantalum and 3D porous titanium from day 7 to 9 (all p < 0.042). Conclusion These results show that porous metal implants can deliver local antibiotics over slightly varying time frames based on in vitro analysis. Cite this article: Bone Joint J 2020;102-B(6 Supple A):158–162.
Two-stage arthrodesis for complex, failed, infected total knee arthroplasty
Matrka, Alexis K., Sems, S.A. , Hanssen, Arlen D. , Pagnano, Mark W. , Mabry, Tad M. , Perry, Kevin I. , Chalmers, Brian P. , Sems, Stephen A, Abdel, Matthew P. , Sierra, Rafael J.

Mayo Clinic

The Bone & Joint Journal | May 31, 2020 | Volume: 102-B | Issue: 6_Supple_A | Pages: 170-175

10.1302/0301-620x.102b6.bjj-2019-1554.r1 | PMID 32475264 Get It

Aims Arthrodesis is rarely used as a salvage procedure for patients with a chronically infected total knee arthroplasty (TKA), and little information is available about the outcome. The aim of this study was to assess the reliability, durability, and safety of this procedure as the definitive treatment for complex, chronically infected TKA, in a current series of patients. Methods We retrospectively identified 41 patients (41 TKAs) with a complex infected TKA, who were treated between 2002 and 2016 using a deliberate, two-stage knee arthrodesis. Their mean age was 64 years (34 to 88) and their mean body mass index (BMI) was 39 kg/m2 (25 to 79). The mean follow-up was four years (2 to 9). The extensor mechanism (EM) was deficient in 27 patients (66%) and flap cover was required in 14 (34%). Most patients were host grade B (56%) or C (29%), and limb grade 3 (71%), according to the classification of McPherson et al. A total of 12 patients (29%) had polymicrobial infections and 20 (49%) had multi-drug resistant organisms; fixation involved an intramedullary nail in 25 (61%), an external fixator in ten (24%), and dual plates in six (15%). Results Survivorship free from amputation, persistent infection, and reoperation, other than removal of an external fixator, at five years was 95% (95% confidence interval (CI) 89% to 100%), 85% (95% CI 75% to 95%), and 64% (95% CI 46% to 82%), respectively. Reoperation, other than removal of an external fixator, occurred in 13 patients (32%). After the initial treatment, radiological nonunion developed in ten knees (24%). Nonunion was significantly correlated with persistent infection (p = 0.006) and external fixation (p = 0.005). Of those patients who achieved limb salvage, 34 (87%) remained mobile and 31 (79%) had ‘absent’ or ‘minimal’ pain ratings. Conclusion Knee arthrodesis using a two-stage protocol achieved a survivorship free from amputation for persistent infection of 95% at five years with 87% of patients were mobile at final follow-up. However, early reoperation was common (32%). This is not surprising as this series included worst-case infected TKAs in which two-thirds of the patients had a disrupted EM, one-third required flap cover, and most had polymicrobial or multi-drug resistant organisms. Cite this article: Bone Joint J 2020;102-B(6 Supple A):170–175.
Excellent two-year survivorship of 3D-printed metaphyseal cones in revision total knee arthroplasty
Perry, Kevin I. , Pagnano, Mark W. , Hanssen, Arlen D. , Tetreault, Matthew W. , Abdel, Matthew P.

Mayo Clinic

The Bone & Joint Journal | May 31, 2020 | Volume: 102-B | Issue: 6_Supple_A | Pages: 107-115

10.1302/0301-620x.102b6.bjj-2019-1544.r1 | PMID 32475272 Get It

AimsMetaphyseal fixation during revision total knee arthroplasty (TKA) is important, but potentially difficult when using historical designs of cone. Material and manufacturing innovations have improved the size and shape of the cones which are available, and simplified the required bone preparation. In a large series, we assessed the implant survivorship, radiological results, and clinical outcomes of new porous 3D-printed titanium metaphyseal cones featuring a reamer-based system.MethodsWe reviewed 142 revision TKAs in 139 patients using 202 cones (134 tibial, 68 femoral) which were undertaken between 2015 and 2016. A total of 60 involved tibial and femoral cones. Most cones (149 of 202; 74%) were used for Type 2B or 3 bone loss. The mean age of the patients was 66 years (44 to 88), and 76 (55 %) were female. The mean body mass index (BMI) was 34 kg/m2(18 to 60). The patients had a mean of 2.4 (1 to 8) previous operations on the knee, and 68 (48%) had a history of prosthetic infection. The mean follow-up was 2.4 years (2 to 3.6).ResultsSurvivorship free of cone revision for aseptic loosening was 100% and survivorship free of any cone revision was 98%. Survivorships free of any revision and any reoperation were 90% and 83%, respectively. Five cones were revised: three for infection, one for periprosthetic fracture, and one for aseptic tibial loosening. Radiologically, three unrevised femoral cones appeared loose in the presence of hinged implants, while the remaining cones appeared stable. All cases of cone loosening occurred in patients with Type 2B or 3 defects. The mean Knee Society score (KSS) improved significantly from 50 (0 to 94) preoperatively to 87 (72 to 94) (p < 0.001). Three intraoperative fractures with cone impaction (two femoral, one tibial) healed uneventfully.ConclusionNovel 3D-printed titanium cones, with a reamer-based system, yielded excellent early survivorship and few complications in patients with severe bone loss undergoing difficult revision TKA. The diversity of cone options, relative ease of preparation, and outcomes rivalling those of previous designs of cone support their continued use. Cite this article: Bone Joint J 2020;102-B(6 Supple A):107–115.