Citations

Clear

885 citation(s) found for "Roy, A".

The influence of acoustic radiation force beam shape and location on wave spectral content for arterial dispersion ultrasound vibrometry
Capriotti, Margherita , Roy, Tuhin , Hugenberg, Nicholas , Harrigan, Hadiya, Lee, Hon-Chi, Aquino, Wilkins , Guddati, Murthy N. , Greenleaf, James F. , Urban, Matthew W. , Hugenberg, Nicholas R , Urban, Matthew W

Mayo Clinic

Physics in Medicine & Biology | June 2, 2022 | Volume: 67 | Issue: 13 | Pages: 135002

10.1088/1361-6560/ac75a7 | PMID 35654033 Get It

Abstract Objective . Arterial dispersion ultrasound vibrometry (ADUV) relies on the use of guided waves in arterial geometries for shear wave elastography measurements. Both the generation of waves through the use of acoustic radiation force (ARF) and the techniques employed to infer the speed of the resulting wave motion affect the spectral content and accuracy of the measurement. In particular, the effects of the shape and location of the ARF beam in ADUV have not been widely studied. In this work, we investigated how such variations of the ARF beam affect the induced motion and the measurements in the dispersive modes that are excited. Approach. The study includes an experimental evaluation on an arterial phantom and an in vivo validation of the observed trends, observing the two walls of the waveguide, simultaneously, when subjected to variations in the ARF beam extension ( F / N ) and focus location. Main results. Relying on the theory of guided waves in cylindrical shells, the shape of the beam controls the selection and nature of the induced modes, while the location affects the measured dispersion curves (i.e. variation of phase velocity with frequency or wavenumber, multiple modes) across the waveguide walls. Significance. This investigation is important to understand the spectral content variations in ADUV measurements and to maximize inversion accuracy by tuning the ARF beam settings in clinical applications.
0407 Early Efficacy With Once-Nightly Sodium Oxybate (ON-SXB; FT218): Post-hoc Analyses From REST-ON
Krahn, Lois E., Roy, Asim, Winkelman, John W. , Morse, A.M., Seiden, David, Dubow, Jordan, Gudeman, Jennifer , Seiden, David , Dubow, Jordan S.

Mayo Clinic

Sleep | May 31, 2022 | Volume: 45 | Issue: Supplement_1 | Pages: A182-A182

10.1093/sleep/zsac079.404 Get It

Abstract Introduction Extended-release once-nightly sodium oxybate (ON-SXB; FT218) is in development for adults with narcolepsy. In REST-ON, significant improvements on the Maintenance of Wakefulness test, Clinical Global Impression of Improvement rating, and number of weekly cataplexy episodes occurred with all analyzed ON-SXB doses vs placebo (week 3, 6-g dose; week 8, 7.5-g dose; week 13, 9-g dose; all P<0.001). ON-SXB was superior to placebo on Epworth Sleepiness Scale (ESS) score and sleep quality and refreshing nature of sleep using visual analog scales (VAS; all P<0.001). ON-SXB 4.5 g significantly reduced cataplexy episodes vs placebo at week 1 (P<0.05). Post hoc analyses investigated ON-SXB efficacy on ESS score, VAS sleep quality, and VAS refreshing nature of sleep at weeks 1 and 2. Methods Participants in the double-blind, phase 3 REST-ON (NCT02720744) trial were ≥16 years old, had narcolepsy type 1 or 2, and were randomized 1:1 to ON-SXB (4.5 g, 1 week; 6 g, 2 weeks; 7.5 g, 5 weeks; 9 g, 5 weeks) or placebo. Participants recorded ESS scores and VAS for sleep quality and refreshing nature of sleep (1-100; 1=poor quality/unrefreshing sleep; 100=good quality/refreshing sleep) using electronic diaries. P-values were calculated using a mixed-effects model for repeated measures in the modified intent-to-treat (mITT) population (ie, participants receiving ≥1 dose of study drug having ≥1 efficacy assessment at week 3). Results In the mITT population (n=190; ON-SXB, n=97; placebo, n=93), baseline ESS scores were 16.6 and 17.5 with ON-SXB and placebo, respectively. At week 2, ESS score was significantly improved with ON-SXB vs placebo (P<0.02) with numerical improvement seen at week 1. At baseline, sleep quality was 53.8 and 55.9 on VAS in the ON-SXB and placebo groups, respectively, and baseline refreshing nature of sleep was 46.5 and 49.9. At weeks 1 and 2, sleep quality (P<0.01; P<0.001) and refreshing nature of sleep (P<0.05; P=0.001) were significantly improved for ON-SXB vs placebo. Conclusion Improvement in daytime sleepiness, sleep quality, and refreshing nature of sleep occurred with ON-SXB beginning the first week of treatment. Some patients may experience early narcolepsy symptom relief with ON-SXB. Support (If Any) Avadel Pharmaceuticals
Drug Interactions Affecting Oral Anticoagulant Use
Mar, Philip L. , Gopinathannair, Rakesh , Gengler, Brooke , Chung, Mina K. , Perez, Arturo, Dukes, Jonathan W., Ezekowitz, Michael D. , Lakkireddy, Dhanunjaya , Miletello, Mike, Reiffel, James A. , Gengler, Brooke E , Lip, Gregory Y H , Miletello, Mike , Noseworthy, Peter A , Reiffel, James A , Tisdale, James E , Olshansky, Brian , Gopinathannair, Rakesh , Noseworthy, Peter A. , Olshansky, Brian

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | May 27, 2022 | Volume: 15 | Issue: 6 | Pages: No page available

10.1161/circep.121.007956 | PMID 35622425 Get It

Oral anticoagulants (OACs) are medications commonly used in patients with atrial fibrillation and other cardiovascular conditions. Both warfarin and direct oral anticoagulants are susceptible to drug-drug interactions (DDIs). DDIs are an important cause of adverse drug reactions and exact a large toll on the health care system. DDI for warfarin mainly involve moderate to strong inhibitors/inducers of cytochrome P450 (CYP) 2C9, which is responsible for the elimination of the more potent S-isomer of warfarin. However, inhibitor/inducers of CYP3A4 and CYP1A2 may also cause DDI with warfarin. Recognition of these precipitating agents along with increased frequency of monitoring when these agents are initiated or discontinued will minimize the impact of warfarin DDI. Direct oral anticoagulants are mainly affected by medications strongly affecting the permeability glycoprotein (P-gp), and to a lesser extent, strong CYP3A4 inhibitors/inducers. Dabigatran and edoxaban are affected by P-gp modulation. Strong inducers of CYP3A4 or P-gp should be avoided in all patients taking direct oral anticoagulant unless previously proven to be otherwise safe. Simultaneous strong CYP3A4 and P-gp inhibitors should be avoided in patients taking apixaban and rivaroxaban. Concomitant antiplatelet/anticoagulant use confers additive risk for bleeding, but their combination is unavoidable in many cases. Minimizing duration of concomitant anticoagulant/antiplatelet therapy as indicated by evidence-based clinical guidelines is the best way to reduce the risk of bleeding.
Muscle oxygenation during normoxic and hypoxic cycling exercise in humans with high‐affinity haemoglobin
Webb, Kevin, Elshaer, Ahmed , Dominelli, Paolo B. , Senefeld, Jonathon W. , Hammer, Shane M. , Baker, Sarah E. , Shepherd, John R.A. , Roy, Tuhin K. , Joyner, Michael J. , Wiggins, Chad C. , Elshaer, Ahmed N, Wiggins, Chad C , Joyner, Michael J , Senefeld, Jonathon W , Roy, Tuhin K , Baker, Sarah E , Webb, Kevin L.

Mayo Clinic

Experimental Physiology | May 23, 2022 | Volume: 107 | Issue: 8 | Pages: 854-863

10.1113/ep090308 | PMID 35603981 Get It

New Findings What is the central question of this study? Do humans with high‐affinity haemoglobin (HAH) demonstrate attenuated skeletal muscle deoxygenation during normoxic and hypoxic exercise? What is the main finding and its importance? Examination of near‐infrared spectroscopy‐derived muscle oxygenation profiles suggests that fractional oxygen extraction is blunted during hypoxic exercise in humans with HAH compared with control subjects. However, muscle tissue oxygen saturation levels were higher in humans with HAH during exercise in normoxia compared with control subjects. These alterations in fractional oxygen extraction in humans with HAH might influence blood flow regulation and exercise capacity during hypoxia. AbstractRecently, researchers in our laboratory have shown that humans with genetic mutations resulting in high‐affinity haemoglobin (HAH) demonstrate better maintained aerobic capacity and peak power output during hypoxic exercise versus normoxic exercise in comparison to humans with normal‐affinity haemoglobin. However, the influence of HAH on tissue oxygenation within exercising muscle during normoxia and hypoxia is unknown. Therefore, we examined near‐infrared spectroscopy‐derived oxygenation profiles of the vastus lateralis during graded cycling exercise in normoxia and hypoxia among humans with HAH (n = 5) and control subjects with normal‐affinity haemoglobin (n = 12). The HAH group elicited a blunted increase of deoxygenated haemoglobin + myoglobin during hypoxic exercise compared with the control group (P = 0.03), suggesting reduced fractional oxygen extraction in the HAH group. In addition, the HAH group maintained a higher level of muscle tissue oxygen saturation during normoxic exercise (HAH, 75 ± 4% vs. controls, 65 ± 3%, P = 0.049) and there were no differences between groups in muscle tissue oxygen saturation during hypoxic exercise (HAH, 68 ± 3% vs. controls, 68 ± 2%, P = 0.943). Overall, our results suggest that humans with HAH might demonstrate divergent patterns of fractional oxygen extraction during hypoxic exercise and elevated muscle tissue oxygenation during normoxic exercise compared with control subjects.
Intraoperative defibrillation testing during replacements of implantable cardioverter-defibrillators: The Simpler trial
Nof, Eyal , Regev, Ehud , Rav, Moshe , Kutyifa, Valentina, Merkely, B, Biffi, M, Cha, YM, Ovdat, T, Klempfner, R., Glikson, Michael , Milman, Anat , Beinart, Roy , Kutyifa, Valentina , Biffi, Mauro , Ovdat, T, Glikson, Michael

Mayo Clinic

EP Europace | May 19, 2022 | Volume: 24 | Issue: Supplement_1 | Pages: No page available

10.1093/europace/euac053.461 Get It

Abstract Funding Acknowledgements Type of funding sources: Foundation. Main funding source(s): Maurice Kahn Foundation via the Mayo- Sheba Collaboration Fund. Background The need for intraoperative defibrillation testing (DFT) during implant and/or replacement of implantable cardioverter-defibrillators (ICDs) has been a matter of debate for many years. This debate was put to rest by the Simple and the Nordic ICD trials, and the practice of testing during new implantations has practically been nearly abandoned. Nevertheless, induction of VF for testing purposes (VFT) may still have an important role in selective populations at risk for defibrillation failure, who were not included in the SIMPLE and Nordic trials. One such population includes those who undergo device replacements. Old registries demonstrated an increased incidence of significant findings in VFT during replacements. In the present study, we sought to test this observation. Objectives Evaluate frequency of significant findings and the safety of VFT in subjects undergoing device replacement. Methods A prospective observational multi-center study of VFT included consecutive patients undergoing ICD generator replacement in 5 centers in Israel, Europe, and the US. All centers followed the same VFT protocol. The primary outcome was defined as failure to terminate induced VF with a single shock at 10 Joules below the maximal capacity of the device. Secondary outcomes included complications of VFT. Patients were followed-up at 1 month and 6 months post-procedure. Data collection included documentation of any peri-operative complications and clinical endpoints (occurrence of appropriate shock, inappropriate shocks, lead failure, need for re-intervention, and infection). Results A total of 92 patients were eligible, and consented for the study, of which 84 underwent DFT during battery replacement. The median age was 68 years and 79.8% were male subjects. Induction of VF was successful in all 84 patients as well as VFT with a successful conversion on first attempt. During follow up one patient had two appropriate ICD shock events. In four patients, the ICD programming was changed. None suffered an inappropriate shock. There was no evidence of lead malfunction. A total of two deaths occurred, none of which were related to the device. Conclusion The present study found VFT was not associated with complications in patients undergoing ICD/CRTD generator replacement but produced no clinically important information.
Functional implications of microvascular heterogeneity for oxygen uptake and utilization
Roy, Tuhin K. , Secomb, Timothy W. , Roy, Tuhin K , Secomb, Timothy W

Mayo Clinic

Physiological Reports | May 18, 2022 | Volume: 10 | Issue: 10 | Pages: No page available

10.14814/phy2.15303 | PMID 35581743 Get It

Abstract In the vascular system, an extensive network structure provides convective and diffusive transport of oxygen to tissue. In the microcirculation, parameters describing network structure, blood flow, and oxygen transport are highly heterogeneous. This heterogeneity can strongly affect oxygen supply and organ function, including reduced oxygen uptake in the lung and decreased oxygen delivery to tissue. The causes of heterogeneity can be classified as extrinsic or intrinsic. Extrinsic heterogeneity refers to variations in oxygen demand in the systemic circulation or oxygen supply in the lungs. Intrinsic heterogeneity refers to structural heterogeneity due to stochastic growth of blood vessels and variability in flow pathways due to geometric constraints, and resulting variations in blood flow and hematocrit. Mechanisms have evolved to compensate for heterogeneity and thereby improve oxygen uptake in the lung and delivery to tissue. These mechanisms, which involve long‐term structural adaptation and short‐term flow regulation, depend on upstream responses conducted along vessel walls, and work to redistribute flow and maintain blood and tissue oxygenation. Mathematically, the variance of a functional quantity such as oxygen delivery that depends on two or more heterogeneous variables can be reduced if one of the underlying variables is controlled by an appropriate compensatory mechanism. Ineffective regulatory mechanisms can result in poor oxygen delivery even in the presence of adequate overall tissue perfusion. Restoration of endothelial function, and specifically conducted responses, should be considered when addressing tissue hypoxemia and organ failure in clinical settings.
Outpatient Randomized Crossover Comparison of Zone Model Predictive Control Automated Insulin Delivery with Weekly Data Driven Adaptation Versus Sensor-Augmented Pump: Results from the International Diabetes Closed-Loop Trial 4
Pinsker, Jordan E. , Dassau, Eyal , Deshpande, Sunil , Raghinaru, Dan, Buckingham, Bruce A. , Kudva, Yogish C. , Laffel, Lori M. , Church, Mei Mei , Desrochers, Hannah, Ekhlaspour, Laya , Kaur, Ravinder Jeet , Levister, Camilla, Lum, John W. , Kollman, Craig, Ambler-Osborn, Louise, Freiner, Emily , O’Malley, Grenye , Brooks, Danielle , Ogyaadu, Selassie, Plesser, Mitchell, Simha, Vinaya , Desjardins, Donna, McCrady-Spitzer, Shelly , Nolander, Lisa, Hsu, Liana, Passman, Samantha, Campos, Tiffany, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreaza-Rubín, Guillermo , Eggerman, Thomas L., Green, Neal, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Ekhlaspour, Laya , Lum, John , Doyle, Francis J , Buckingham, Bruce , Levy, Carol J. , Shi, Dawei , Kollman, Craig , Doyle, Francis J. , Isganaitis, Elvira , Beck, Roy W. , Green, Jennifer Greif , Willi, Steven Matthew

Mayo Clinic

Diabetes Technology & Therapeutics | May 12, 2022 | Volume: 24 | Issue: 9 | Pages: 635-642

10.1089/dia.2022.0084 | PMID 35549708 Get It

Background: Automated insulin delivery (AID) systems have proven effective in increasing time-in-range during both clinical trials and real-world use. Further improvements in outcomes for single-hormone (insulin only) AID may be limited by suboptimal insulin delivery settings. Methods: Adults (≥18 years of age) with type 1 diabetes were randomized to either sensor-augmented pump (SAP) (inclusive of predictive low-glucose suspend) or adaptive zone model predictive control AID for 13 weeks, then crossed over to the other arm. Each week, the AID insulin delivery settings were sequentially and automatically updated by an adaptation system running on the study phone. Primary outcome was sensor glucose time-in-range 70–180 mg/dL, with noninferiority in percent time below 54 mg/dL as a hierarchical outcome. Results: Thirty-five participants completed the trial (mean age 39 ± 16 years, HbA1c at enrollment 6.9% ± 1.0%). Mean time-in-range 70–180 mg/dL was 66% with SAP versus 69% with AID (mean adjusted difference +2% [95% confidence interval: −1% to +6%], P = 0.22). Median time <70 mg/dL improved from 3.0% with SAP to 1.6% with AID (−1.5% [−2.4% to −0.5%], P = 0.002). The adaptation system decreased initial basal rates by a median of 4% (−8%, 16%) and increased initial carbohydrate ratios by a median of 45% (32%, 59%) after 13 weeks. Conclusions: Automated adaptation of insulin delivery settings with AID use did not significantly improve time-in-range in this very well-controlled population. Additional study and further refinement of the adaptation system are needed, especially in populations with differing degrees of baseline glycemic control, who may show larger benefits from adaptation.
NCCN Guidelines® Insights: Hematopoietic Growth Factors, Version 1.2022
Alwan, Laura, Bachiashvili, Kimo, Baird, John H. , Cool, Rita, Dinner, Shira, Gojo, Ivana , Hicks, Ashley, Kidwai, Wajih Zaheer, Kloth, Dwight D. , Kraut, Eric H., Mahajan, Anjlee , Miller, Ryan, Nachar, Victoria , Patel, Shiven B. , Perez, Lia, Poust, Adam, Riaz, Fauzia , Rosovsky, Rachel , Simon, Shayna, Vasu, Sumithira , Wadleigh, Martha , Westbrook, Kelly , Westervelt, Peter, Berardi, Ryan A., Pluchino, Lenora A. , Griffiths, Elizabeth A. , Roy, Vivek , Geyer, Mark Blaine , Glaspy, John A. , Kallam, Avyakta , Landsburg, Daniel J. , Lyman, Gary H , Patel, Seema V. , Rugo, Hope S. , Simon, Shayna

Mayo Clinic

Journal of the National Comprehensive Cancer Network | May 11, 2022 | Volume: 20 | Issue: 5 | Pages: 436-442

10.6004/jnccn.2022.0026 | PMID 35545171 Get It

The NCCN Guidelines for Hematopoietic Growth Factors provide recommendations for the appropriate use of growth factors in the clinical management of febrile neutropenia (FN), chemotherapy-induced thrombocytopenia (CIT), and chemotherapy-induced anemia (CIA). Management and prevention of these sequelae are an integral part of supportive care for many patients undergoing cancer treatment. The purpose of these guidelines is to operationalize the evaluation, prevention, and treatment of FN, CIT, and CIA in adult patients with nonmyeloid malignancies and to enable the patient and clinician to assess management options for FN, CIT, and CIA in the context of an individual patient’s condition. These NCCN Guidelines Insights provide a summary of the important recent updates to the NCCN Guidelines for Hematopoietic Growth Factors, with particular emphasis on the incorporation of a newly developed section on CIT.
Blood Flow Heterogeneity and Oxygenation in the Lung: Effect of the Hypoxic Pulmonary Vasoconstriction Response Curve
Roy, Tuhin K. , Roy, Tuhin K , Secomb, Timothy W.

Mayo Clinic

The FASEB Journal | May 3, 2022 | Volume: 36 | Issue: S1 | Pages: No page available

10.1096/fasebj.2022.36.s1.r6328 Get It

The ability of the lung to take up oxygen can be characterized by its effective diffusing capacity, which is determined by the transport characteristics of the alveolar‐capillary membrane as well as heterogeneity of pulmonary blood flow. At rest, the healthy lung has a high degree of tolerance for pulmonary flow heterogeneity, but under conditions of physiological stress such as exercise, oxygen uptake may be inadequate to satisfy tissue demand if flow is very heterogeneous. We previously used a mathematical model of pulmonary oxygen uptake to examine the ability of hypoxic pulmonary vasoconstriction (HPV) to mitigate flow heterogeneity. In the model, flow heterogeneity is characterized by the coefficient of variation (CV) of pulmonary capillary blood flow. Assuming an initial lognormal distribution of blood flow with a normal level of heterogeneity (CV = 1.66), we simulate flow regulation over a range of oxygen consumption from rest to maximal exercise by adjusting pulmonary flow resistance in each vessel in accordance with an HPV response curve obtained from previously published experimental data. The effect of HPV on vessel flow resistance is assumed to be characterized by a sigmoidal response dependent on the capillary oxygen tension, which is approximated as the mean of the venous and arterial values in each pulmonary capillary; its maximal sensitivity occurs at a stimulus oxygen tension of approximately 30 torr. The purpose of the present study was to determine whether altering the shape of the HPV response curve would result in an improvement in CV reduction. Altering the HPV by shifting the sigmoidal curve to the right by 10 or 20 torr worsened CV, extraction and total pulmonary vascular resistance (PVR). Similar detrimental results were obtained when the range of oxygen tensions over which HPV varied was expanded by a factor of two, increasing the oxygen tension at which the sensitivity of HPV to oxygen tension was maximal. On the other hand, shrinking the range of variation of the HPV curve by a factor of two neither improved nor significantly worsened the CV or extraction, and resulted in a PVR distribution similar to the case of the normal HPV curve. These results demonstrate that the observed shape of the HPV response tends to minimize heterogeneity of pulmonary flow under conditions of exercise.
Cardiac baroreflex sensitivity and heart rate variability are lower in humans with high affinity hemoglobin compared to typical affinity hemoglobin
Pruter, Wyatt W. , Dominelli, Paolo B. , Joyner, Michael J. , Joyner, Michael J , Klassen, Stephen A. , Wiggins, Chad C. , Senefeld, Jonathon W. , Roy, Tuhin K. , Baker, Sarah E.

Mayo Clinic

The FASEB Journal | May 3, 2022 | Volume: 36 | Issue: S1 | Pages: No page available

10.1096/fasebj.2022.36.s1.0r874 Get It

Background Humans with high O 2 affinity hemoglobin (HAH) have a markedly lower partial pressure of O 2 at which 50% of hemoglobin is saturated (P 50 ) and a leftward shift of the oxy‐hemoglobin dissociation curve. Humans with HAH have attenuated heart rate responses during both acute and chronic hypoxic exposure relative to humans with typical P 50 . Despite the attenuated heart rate responses to hypoxia, there are typically no blood pressure differences found in humans with HAH relative to humans with typical P 50 . Due to the blunted heart rate and normal blood pressure responses to hypoxia in humans with HAH, this study aimed to investigate the impact of HAH on cardiac autonomic function during normoxia and hypoxia. We hypothesized that humans with HAH would have lower cardiac baroreflex sensitivity (cBRS) and heart rate variability (HRV) during normoxia and hypoxia relative to individuals with typical P 50. Methods Nine humans with a HAH mutation (6 female, Age: 40±12yrs, P 50 : 16±1 mmHg) and 12 controls with typical affinity hemoglobin (6 female, Age: 40±10yrs, P 50 : 26±1 mmHg) laid supine for 10‐minutes prior to 20‐minutes of isocapnic hypoxia, titrated to reduce arterial O 2 pressure to ~50 mmHg (Avg. F i O 2 = 11.9±0.0%). Beat‐to‐beat arterial pressures (arterial catheter) and heart rate (electrocardiogram) were continuously recorded. Data were averaged in five‐minute segments starting with the last five minutes of supine normoxic rest. Spontaneous cBRS was quantified using the sequence method. HRV was measured in time and frequency domains. Standard deviation of the RR interval (SDRR) was calculated as the standard deviation of all RR intervals in a data segment. Low frequency (LF) HRV was calculated using Fast Fourier Transformation and assessed as absolute spectral intensity in the LF band (0.04‐0.15Hz). Results Arterial oxygen (P a O 2 ) and carbon dioxide (P a CO 2 ) pressures were not different between humans with HAH and controls during normoxia or isocapnic hypoxia [P a O 2 : (HAH vs. Control): 48±3 vs. 47±2 mmHg, p=0.612; P a CO 2 : (HAH vs. Control): 40±3 vs. 39±1 mmHg, p=0.328] exposure. cBRS was lower in humans with HAH compared to controls in normoxia and throughout isocapnic hypoxia [normoxia (HAH vs. Control): 7±4 vs. 16±10 ms/mmHg; hypoxia minutes 15‐20 (HAH vs. Control): 4±3 vs. 14±11 ms/mmHg; Hb type, p=0.024]. Several metrics of HRV were lower in humans with HAH relative to control (SDRR: Hb type, p≤0.001; LF: Hb type, p=0.030) and HRV was blunted to a similar extent in both groups with hypoxia (SDRR: time effect, p=0.009). Conclusion The findings of this study are twofold. Compared to controls, humans with HAH have: 1) attenuated cardiac baroreflex sensitivity and 2) lower heart rate variability in both normoxia and isocapnic hypoxia.