Citations

Clear

44 citation(s) found for "Watson, Robert".

Magnetic Resonance Imaging in Nondependent Pacemaker Patients with Pacemakers and Defibrillators with a Nearly Depleted Battery
Okamura, Hideo , Padmanabhan, Deepak , Watson, Robert E. , Dalzell, Connie, Acker, Nancy, Jondal, Mary Lou, ROMME, ABBY L., Cha, Yong‐Mei , Asirvatham, Samuel J. , Felmlee, Joel P. , Friedman, Paul A. , Jondal, Mary, Asirvatham, Samuel J

Mayo Clinic

Pacing and Clinical Electrophysiology | February 7, 2017 | Volume: 40 | Issue: 5 | Pages: 476-481

10.1111/pace.13042 | PMID 28169434 Get It

BackgroundMagnetic resonance imaging (MRI) in patients with non‐MRI‐conditional cardiac implantable electronic devices (CIEDs) has been shown to be safe when performed under closely monitored protocols. However, the safety of MRI in patients with devices with a nearly depleted battery has not been reported.MethodsProspective data were collected between January 2008 and May 2015 in patients with non‐MRI‐conditional CIEDs undergoing clinically indicated MRI under institutional protocol. Patients who were pacemaker dependent were excluded. Patients whose devices were at elective replacement indicator (ERI) at the time of MRI or close to ERI (ERI or replacement for battery depletion within 3 months of scan) were identified through database review and analyzed for clinical events.ResultsMRI scans (n = 569) were performed in 442 patients. Of these, we identified 13 scans performed with a nearly depleted battery in nine patients. All scans with implantable cardioverter defibrillators (ICDs, n = 9) were uneventful. However, two scans with pacemakers close to ERI resulted in a power‐on‐reset (PoR) event. One scan with a pacemaker close to ERI that was programmed to DOO mode reached ERI during MRI and automatically changed to VVI mode. Additionally, one scan with a pacemaker at ERI did not allow programming. All pacemakers with events were implanted before 2005.ConclusionPatients with pacemakers and ICDs with a nearly depleted battery can safely undergo MRI when patients are not pacemaker dependent. Attention should be paid because old devices can result in PoR or ERI during MRI, which may lead to oversensing and inhibition of pacing.
Magnetic resonance imaging–guided laser interstitial thermal therapy for previously treated hypothalamic hamartomas
Burrows, Anthony M. , Marsh, W. Richard , Woodrum, David A. , Pollock, Bruce E. , Gorny, Krzysztof R. , Felmlee, Joel P. , Watson, Robert E. , Goerss, Steven, Worrell, Gregory A. , Kaufmann, Timothy J. , Goerss, S, Gompel, Jamie J. Van

Mayo Clinic

Neurosurgical Focus | October 1, 2016 | Volume: 41 | Issue: 4 | Pages: E8

10.3171/2016.7.focus16218 | PMID 27690651 Get It

OBJECTIVE Hypothalamic hamartomas (HHs) are associated with gelastic seizures and the development of medically refractory epilepsy. Magnetic resonance imaging–guided laser interstitial thermal therapy (MRg-LITT) is a minimally invasive ablative treatment that may have applicability for these deep-seated lesions. Here, the authors describe 3 patients with refractory HHs who they treated with MRg-LITT. METHODS An institutional review board–approved prospective database of patients undergoing Visualase MRg-LITT was retrospectively reviewed. Demographic and historical medical data, including seizure and medication histories, previous surgeries, procedural details, and surgical complications, along with radiological interpretation of the HHs, were recorded. The primary outcome was seizure freedom, and secondary outcomes included medication reduction, seizure frequency, operative morbidity, and clinical outcome at the latest follow-up. RESULTS All 3 patients in the multi-institutional database had developed gelastic seizures related to HH at the ages of 7, 7, and 9 years. They presented for further treatment at 25, 28, and 48 years of age, after previous treatments with stereotactic radiosurgery in all cases and partial hamartoma resection in one case. One ablation was complicated by a small tract hemorrhage, which was stable on postoperative imaging. One patient developed hyponatremia and experienced weight gain, which were respectively managed with fluid restriction and counseling. At the most recent follow-up at a mean of 21 months (range 1–32 months), one patient was seizure free while another had meaningful seizure reduction. Medication was reduced in one case. CONCLUSIONS Adults with gelastic seizures despite previous treatments can undergo MRg-LITT with reasonable safety and efficacy. This novel therapy may provide a minimally invasive alternative for primary and recurrent HH as the technique is refined.
Basal ganglia T1 hyperintensity in LGI1-autoantibody faciobrachial dystonic seizures
Flanagan, Eoin P. , McKeon, Andrew , Watson, Robert E. , Klein, Christopher J. , Lowe, Val J. , Ahlskog, J. Eric , Shin, Cheolsu, Laughlin, Ruple S. , Pittock, Sean J. , Kotsenas, Amy L. , Boes, Christopher J. , Crum, Brian A. , Pittock, S J , Britton, Jeffrey W. , Boeve, Bradley F. , Flanagan, E P , Klein, Christopher J , McKeon, Andrew

Mayo Clinic

Neurology Neuroimmunology & Neuroinflammation | October 2, 2015 | Volume: 2 | Issue: 6 | Pages: No page available

10.1212/nxi.0000000000000161 | PMID 26468474 Get It

Paraspinal neurofibromas and hypertrophic neuropathy in Noonan syndrome with multiple lentigines
Conboy, Erin , Dhamija, Radhika , Wang, Margaret , Xie, Jing , Dyck, P. James B. , Bridges, Alina G. , Spinner, Robert J. , Clayton, Amy C., Watson, Robert E. , Messiaen, Ludwine , Babovic‐Vuksanovic, Dusica , Dyck, P James, Dhamija, Radhika

Mayo Clinic

Journal of Medical Genetics | September 2, 2015 | Volume: 53 | Issue: 2 | Pages: 123-126

10.1136/jmedgenet-2015-103177 | PMID 26337637 Get It

Background Noonan syndrome with multiple lentigines (NSML), formerly known as LEOPARD syndrome, is an autosomal-dominant disorder characterised by lentigines, EKG abnormalities, ocular hypertelorism, pulmonic stenosis, abnormal genitalia, growth retardation and deafness. There is significant clinical overlap between NSML and other disorders that result from dysregulated rat sarcoma/mitogen-activated protein kinase pathway (RASopathies). Except for neurofibromatosis type 1, other RASopathies are not known to be typically associated with neurogenic tumours. Methods and results We evaluated patients from three families with pigmentary skin lesions, progressive neuropathy, enlarged nerves, massive burden of paraspinal tumours (neurofibroma was confirmed in one patient) and a clinical diagnosis of NSML. All patients had a mutation in the protein tyrosine phosphatase catalytic domain of the PTPN11 gene; two unrelated patients had the p.Thr468Met mutation, while the family consisting of two affected individuals harboured the p.Thr279Cys mutation. Molecular analysis performed on hypertrophic nerve tissue did not disclose a second somatic hit in NF1, PTPN11, NF2 or SMARCB1 genes. Conclusions Neurogenic tumours and hypertrophic neuropathy are unusual complications of NSML and may be an under-recognised manifestation that would warrant surveillance. Our observation may also have implications for other disorders caused by RAS-pathway dysregulation.
Florida Initiative for Quality Cancer Care: Changes in Psychosocial Quality of Care Indicators Over a 3-Year Interval
Jacobsen, Paul B. , Lee, Ji‐Hyun , Fulp, William J. , Siegel, Erin M. , Shibata, David , Laronga, Christine , Gray, Jhanelle E. , Schreiber, Fred, Brown, R. H. , Levine, Richard M., Cartwright, Thomas H. , Abesada‐Terk, Guillermo, Kim, George , Alemany, Carlos, Faig, Douglas, Sharp, Philip, Markham, Merry Jennifer , Malafa, Mokenge P. , Fulp, William, Gray, Jhanelle, Tanvetyanon, Tawee , BROWN, RICHARD, Levine, Richard, Cartwright, Thomas, Abesada-Terk, Guillermo, Malafa, Mokenge, Markham, Merry J

Mayo Clinic

Journal of Oncology Practice | February 26, 2015 | Volume: 11 | Issue: 1 | Pages: e103-e109

10.1200/jop.2014.001525 | PMID 25352389 Get It

Findings suggest that more intensive efforts than audit and feedback will be required to improve the quality of psychosocial care, and that greater recognition of problems with emotional well-being may tax the ability of practices to link patients with appropriate services.
Safety and Outcomes of Magnetic Resonance Imaging in Patients with Abandoned Pacemaker and Defibrillator Leads
Higgins, John V., Gard, Joseph J., Espinosa, Raúl E. , Wood, Christopher P. , Felmlee, Joel P. , Cha, Yong‐Mei , Asirvatham, Samuel J. , Dalzell, Connie, Acker, Nancy, Watson, Robert E. , Friedman, Paul A. , Sheldon, Seth H. , Asirvatham, Samuel J

Mayo Clinic

Pacing and Clinical Electrophysiology | May 9, 2014 | Volume: 37 | Issue: 10 | Pages: 1284-1290

10.1111/pace.12419 | PMID 24809591 Get It

IntroductionAbandoned cardiovascular implantable electronic device (CIED) leads remain a contraindication to magnetic resonance imaging (MRI) studies, largely due to in vitro data showing endocardial heating secondary to the radiofrequency field. We tested the hypothesis that abandoned CIED leads do not pose an increased risk of clinical harm for patients undergoing MRI.MethodsThis single‐center retrospective study examined the outcomes of patients who had device generators removed before MRI, rendering the device leads abandoned. Information was gathered through chart review. Data collected included lead model, pacing threshold before MRI, anatomic region examined, threshold data after generator reimplantation, and clinical patient outcome.ResultsPatients (n = 19, 11 men and eight women) ranged in age from 19 to 85 at the time of MRI. There was a mean of 1.63 abandoned leads at the time of imaging; none of the leads were MRI conditional. Of the three implantable cardioverter defibrillator (ICD) leads, two of three were dual coil. Most (31/35) of the scans performed were of the central nervous system, including head and spinal imaging. There were no adverse events associated with MRI in any of these patients with abandoned leads within 7 days of the scan. No lead malfunctions or clinically significant change in pacing thresholds were noted with generator reimplantation.ConclusionThe use of MRI in patients with abandoned cardiac device leads appears feasible when performed under careful monitoring, with no adverse events, although the experience is small. MRI did not affect the function of leads that were subsequently reconnected to a cardiac device.
Interictal Scalp Electroencephalography and Intraoperative Electrocorticography in Magnetic Resonance Imaging–Negative Temporal Lobe Epilepsy Surgery
Burkholder, David B. , Šulc, Vlastimil , Hoffman, E. Matthew , Cascino, Gregory D. , So, Elson L., Marsh, W. Richard , Meyer, Fredric B. , Wass, C. Thomas, Watson, Robert E. , Van Gompel, Jamie J, Britton, Jeffrey W. , Gompel, Jamie J. Van , Giannini, Caterina , Worrell, Gregory A. , Burkholder, David B

Mayo Clinic

JAMA Neurology | April 28, 2014 | Volume: 71 | Issue: 6 | Pages: 702

10.1001/jamaneurol.2014.585 | PMID 24781216 Get It

Magnetic Resonance Imaging in Patients with Recently Implanted Pacemakers
Friedman, Hannah, Acker, Nancy, Dalzell, Connie, Shen, Win K., Asirvatham, Samuel J. , Cha, Yong‐Mei , Hodge, David O. , Felmlee, Joel P. , Watson, Robert E. , Friedman, Paul A. , Friedman, Hannah L, Asirvatham, Samuel J

Mayo Clinic

Pacing and Clinical Electrophysiology | July 4, 2013 | Volume: 36 | Issue: 9 | Pages: 1090-1095

10.1111/pace.12213 | PMID 23826621 Get It

BackgroundRecent studies have shown that magnetic resonance imaging (MRI) of patients with pacemakers can be safely performed under careful monitoring, but they excluded patients with recently implanted devices. Patients with recent implants may be at a greater risk for complications during MRI imaging due to lack of lead and wound maturity.MethodsWe implemented a clinical protocol for MRI imaging of patients with implanted cardiac devices, and prospectively collected data. For this study, we retrospectively analyzed two groups of patients: those with recently implanted (≤42 days) and nonrecently implanted (>42 days) leads at the time of MRI scanning. All devices were interrogated before and after scanning, and were reprogrammed during the scan as per protocol.ResultsOf the 219 scans (in 171 patients), eight included patients with recently implanted (range: 7–36 days) and 211 with only nonrecently implanted pacemaker leads. During the scan, there were no complications in the early or late group. In one patient imaged 79 days postimplant, frequent premature ventricular complexes were noted during the scan, requiring no action. No patient reported pain during or immediately after the procedure. No clinically significant changes in function were seen at subsequent follow up (average 104 days post‐MRI). Compared to patients with nonrecently implanted leads, there was no difference in any parameter between the two groups.ConclusionsWith a strong clinical indication and with careful monitoring, MRI imaging is feasible in patients with recently implanted pacemakers, although experience is limited.
Scalp and Intracranial EEG in Medically Intractable Extratemporal Epilepsy with Normal MRI
Zakaria, Tarek, So, Elson, Cascino, Gregory D. , Wetjen, Nicholas M. , Marsh, W. Richard , Meyer, Fredric B. , Watson, Robert E. , Noe, Katherine H. , So, Elson L., Gompel, Jamie J. Van , Giannini, Caterina , Worrell, Gregory A.

Mayo Clinic

ISRN Neurology | July 29, 2012 | Volume: 2012 | Issue: No issue available | Pages: 1-9

10.5402/2012/942849 | PMID 22792484 Get It

Purpose. To investigate EEG and SPECT in the surgical outcome of patients with normal MRI (nonlesional) and extratemporal lobe epilepsy. Methods. We retrospectively identified 41 consecutive patients with nonlesional extratemporal epilepsy who underwent epilepsy surgery between 1997 and 2007. The history, noninvasive diagnostic studies (scalp EEG, MRI, and SPECT) and intracranial EEG (iEEG) monitoring was reviewed. Scalp and iEEG ictal onset patterns were defined. The association of preoperative studies and postoperative seizure freedom was analyzed using Kaplan-Meier analysis, log-rank test, and Cox proportional hazard. Results. Thirty-six of 41 patients had adequate information with a minimum of 1-year followup. Favorable surgical outcome was identified in 49% of patients at 1 year, and 35% at 4-year. On scalp EEG, an ictal onset pattern consisting of focal beta-frequency discharge (>13–125 Hz) was associated with favorable surgical outcome (P=0.02). Similarly, a focal fast-frequency oscillation (>13–125 Hz) on iEEG at ictal onset was associated with favorable outcome (P=0.03). Discussion. A focal fast-frequency discharge at ictal onset identifies nonlesional MRI, extratemporal epilepsy patients likely to have a favorable outcome after resective epilepsy surgery.