Citations

Clear

50 citation(s) found for "Thoreson, Andrew".

Interpreting oblique impact data from an accelerometer-instrumented ice hockey helmet
Jorgensen, Janelle, Thoreson, Andrew R. , Stuart, Michael, Loyd, Andre M., Smith, Aynsley M., Twardowski, Casey P., Gaz, Daniel V., Hollman, John H. , An, Kai , Krause, David A. , An, Kai Nan, Stuart, Michael J. , Hollman, John

Mayo Clinic

Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology | April 7, 2017 | Volume: 231 | Issue: 4 | Pages: 307-316

10.1177/1754337117700549 Get It

The purpose of this study was to assess the correlations of acceleration measurements between an instrumented hockey helmet and the Hybrid III headform and to determine whether collision with a broad surface affects the correlations between these data. A CCM Vector hockey helmet, instrumented with the Head Impact Telemetry System, was fitted onto an instrumented Hybrid III headform and dropped onto an inclined plate to simulate impacts in hockey. The helmet and headform were dropped from 0.15, 0.30, and 0.60 m at different orientations to create impacts to the vertex, occipital, right, left, and forehead surfaces. Peak linear and rotational acceleration magnitudes and head injury criteria were assessed for each system. Correlations were assessed with the Pearson correlation coefficient, and linear regression models were generated. Relative error was assessed, and results were compared with the Wilcoxon signed rank test. Peak acceleration magnitudes generally had strong mathematical correlations, although a 1:1 linear relationship for rotational acceleration data was not observed. Differences between helmet and head peak acceleration magnitudes were significant. The linear relationship varied according to the impact direction. Instrumented helmet and head data demonstrated a strong mathematical correlation, but measures of linear acceleration generally had better 1:1 agreement than rotational acceleration measures. There is some dependence in the relationship between the helmet and head data on the impact direction, with vertex strikes showing the weakest correlation. Although data generated from the helmet may be useful for interpreting head accelerations experienced by on-ice players, additional analysis of the time-series data should be performed to understand its full utility.
The revitalisation of flexor tendon allografts with bone marrow stromal cells and mechanical stimulation
Wu, Jingheng , Thoreson, Andrew R. , Gingery, Anne , An, Kai‐Nan , Moran, Steven L. , Amadio, Peter C. , Zhao, Chunfeng , Gingery, Anne

Mayo Clinic

Bone & Joint Research | March 31, 2017 | Volume: 6 | Issue: 3 | Pages: 179-185

10.1302/2046-3758.63.bjr-2016-0207.r1 | PMID 28360084 Get It

Objectives The present study describes a novel technique for revitalising allogenic intrasynovial tendons by combining cell-based therapy and mechanical stimulation in an ex vivo canine model. Methods Specifically, canine flexor digitorum profundus tendons were used for this study and were divided into the following groups: (1) untreated, unprocessed normal tendon; (2) decellularised tendon; (3) bone marrow stromal cell (BMSC)-seeded tendon; and (4) BMSC-seeded and cyclically stretched tendon. Lateral slits were introduced on the tendon to facilitate cell seeding. Tendons from all four study groups were distracted by a servohydraulic testing machine. Tensile force and displacement data were continuously recorded at a sample rate of 20 Hz until 200 Newton of force was reached. Before testing, the cross-sectional dimensions of each tendon were measured with a digital caliper. Young’s modulus was calculated from the slope of the linear region of the stress-strain curve. The BMSCs were labeled for histological and cell viability evaluation on the decellularized tendon scaffold under a confocal microscope. Gene expression levels of selected extracellular matrix tendon growth factor genes were measured. Results were reported as mean ± SD and data was analyzed with one-way ANOVAs followed by Tukey’s post hoc multiple-comparison test. Results We observed no significant difference in cross-sectional area or in Young’s modulus among the four study groups. In addition, histological sections showed that the BMSCs were aligned well and viable on the tendon slices after two-week culture in groups three and four. Expression levels of several extracellular matrix tendon growth factors, including collagen type I, collagen type III, and matrix metalloproteinase were significantly higher in group four than in group three (p < 0.05). Conclusion Lateral slits introduced into de-cellularised tendon is a promising method of delivery of BMSCs without compromising cell viability and tendon mechanical properties. In addition, mechanical stimulation of a cell-seeded tendon can promote cell proliferation and enhance expression of collagen types I and III in vitro. Cite this article: J. H. Wu, A. R. Thoreson, A. Gingery, K. N. An, S. L. Moran, P. C. Amadio, C. Zhao. The revitalisation of flexor tendon allografts with bone marrow stromal cells and mechanical stimulation: An ex vivo model revitalising flexor tendon allografts. Bone Joint Res 2017;6:179–185. DOI: 10.1302/2046-3758.63.BJR-2016-0207.R1.
Biomechanical analysis of the effect of congruence, depth and radius on the stability ratio of a simplistic ‘ball-and-socket’ joint model
Werthel, J-D., Thoreson, Andrew R. , Resch, Herbert, An, K-N, Moroder, Philipp , Ernstbrunner, Lukas , Werthel, J.D., Hatta, Taku , An, K-N.

Mayo Clinic

Bone & Joint Research | October 12, 2016 | Volume: 5 | Issue: 10 | Pages: 453-460

10.1302/2046-3758.510.bjr-2016-0078.r1 | PMID 27729312 Get It

ObjectivesThe bony shoulder stability ratio (BSSR) allows for quantification of the bony stabilisers in vivo. We aimed to biomechanically validate the BSSR, determine whether joint incongruence affects the stability ratio (SR) of a shoulder model, and determine the correct parameters (glenoid concavity versus humeral head radius) for calculation of the BSSR in vivo.MethodsFour polyethylene balls (radii: 19.1 mm to 38.1 mm) were used to mould four fitting sockets in four different depths (3.2 mm to 19.1mm). The SR was measured in biomechanical congruent and incongruent experimental series. The experimental SR of a congruent system was compared with the calculated SR based on the BSSR approach. Differences in SR between congruent and incongruent experimental conditions were quantified. Finally, the experimental SR was compared with either calculated SR based on the socket concavity or plastic ball radius.ResultsThe experimental SR is comparable with the calculated SR (mean difference 10%, sd 8%; relative values). The experimental incongruence study observed almost no differences (2%, sd 2%). The calculated SR on the basis of the socket concavity radius is superior in predicting the experimental SR (mean difference 10%, sd 9%) compared with the calculated SR based on the plastic ball radius (mean difference 42%, sd 55%).ConclusionThe present biomechanical investigation confirmed the validity of the BSSR. Incongruence has no significant effect on the SR of a shoulder model. In the event of an incongruent system, the calculation of the BSSR on the basis of the glenoid concavity radius is recommended. Cite this article: L. Ernstbrunner, J-D. Werthel, T. Hatta, A. R. Thoreson, H. Resch, K-N. An, P. Moroder. Biomechanical analysis of the effect of congruence, depth and radius on the stability ratio of a simplistic ‘ball-and-socket’ joint model. Bone Joint Res 2016;5:453–460. DOI: 10.1302/2046-3758.510.BJR-2016-0078.R1.
THE EFFECT OF FREEZING ON BIOMECHANICAL PROPERTIES OF THE CARPAL TUNNEL SUBSYNOVIAL CONNECTIVE TISSUE
Filius, Anika , Thoreson, Andrew R. , Dharan, Abhishek, Mara, Kristin C. , An, Kai‐Nan , Zhao, Chunfeng , Amadio, Peter C. , Mara, Kristin C

Mayo Clinic

Journal of Musculoskeletal Research | April 7, 2016 | Volume: 18 | Issue: 04 | Pages: 1550019

10.1142/s0218957715500190 Get It

Biomechanical evaluation of the subsynovial connective tissue (SSCT) provides insight into the causes of carpal tunnel syndrome. Studies of carpal tunnel mechanics have been performed using fresh-frozen cadaver tissue. Freezing can affect mechanical properties of some tissues, but its effect on SSCT is unknown. A total of 16 rabbit paws were harvested from eight New Zealand rabbits and subjected to mechanical testing consisting of three repeated tendon excursions in sets of three different excursion magnitudes. One paw from each animal was unfrozen. The contralateral paw was frozen and thawed before testing. Force, energy and stiffness of the first cycle of each set were evaluated, as were ratios of the second to first cycle for each parameter. Two-factor ANOVA with repeated measures over both factors was performed. No significant interactions between factors were found. There were no significant differences between fresh and frozen paws for any parameters, though there were significant differences between excursion amplitudes. The damage threshold was not different between fresh and frozen paws. This study demonstrated that freezing rabbit subsynovial connective tissue does not significantly change its mechanical properties. The same may be true for human cadaver tissues. Results of cadaver mechanical testing may not be influenced by this preservation technique.
Effects of lubricant and autologous bone marrow stromal cell augmentation on immobilized flexor tendon repairs
Zhao, Chunfeng , Ozasa, Yasuhiro , Shimura, Haruhiko , Reisdorf, Ramona L., Thoreson, Andrew R. , Jay, Gregory D. , Moran, Steven L. , An, Kai‐Nan, Amadio, Peter C. , An, Kai‐Nan

Mayo Clinic

Journal of Orthopaedic Research | July 16, 2015 | Volume: 34 | Issue: 1 | Pages: 154-160

10.1002/jor.22980 | PMID 26177854 Get It

ABSTRACTThe purpose of the study was to test a novel treatment that carbodiimide‐derivatized‐hyaluronic acid‐lubricin (cd‐HA‐lubricin) combined cell‐based therapy in an immobilized flexor tendon repair in a canine model. Seventy‐eight flexor tendons from 39 dogs were transected. One tendon was treated with cd‐HA‐lubricin plus an interpositional graft of 8 × 105 BMSCs and GDF‐5. The other tendon was repaired without treatment. After 21 day of immobilization, 19 dogs were sacrificed; the remaining 20 dogs underwent a 21‐day rehabilitation protocol before euthanasia. The work of flexion, tendon gliding resistance, and adhesion score in treated tendons were significantly less than the untreated tendons (p < 0.05). The failure strength of the untreated tendons was higher than the treated tendons at 21 and 42 days (p < 0.05). However, there is no significant difference in stiffness between two groups at day 42. Histologic analysis of treated tendons showed a smooth surface and viable transplanted cells 42 days after the repair, whereas untreated tendons showed severe adhesion formation around the repair site. The combination of lubricant and cell treatment resulted in significantly improved digit function, reduced adhesion formation. This novel treatment can address the unmet needs of patients who are unable to commence an early mobilization protocol after flexor tendon repair. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:154–160, 2016.
Biomechanical evaluation of flexor tendon graft with different repair techniques and graft surface modification
Wu, Jingheng , Thoreson, Andrew R. , Reisdorf, Ramona L., An, Kai‐Nan, Moran, Steven L. , Amadio, Peter C. , Zhao, Chunfeng , An, Kai‐Nan

Mayo Clinic

Journal of Orthopaedic Research | February 9, 2015 | Volume: 33 | Issue: 5 | Pages: 731-737

10.1002/jor.22844 | PMID 25665071 Get It

ABSTRACTThe purpose of this study was to investigate the biomechanical properties of modified repair techniques for flexor tendon reconstruction and the effects of surface modification using carbodiimide‐derivatized synovial fluid plus gelatin (cd‐SF‐G), compared to the traditional repair techniques. The second and fifth digits from 16 canine forepaws were randomly divided into 4 groups: (1) traditional graft repairs (TGR group) including distal Bunnell repair and proximal Pulvertaft weave repair; (2) modified graft repairs (MGR group) including distal graft bony attachment repair and proximal step‐cut repair; (3) group TGR coated with cd‐SF‐G (TGR‐C group); and (4) group MGR coated with cd‐SF‐G (MGR‐C group). Digit normalized work of flexion (nWOF), ultimate failure strength, and stiffness were measured. The nWOF in MGR group was significantly less than TGR group (p < 0.05). The nWOF in groups treated with cd‐SF‐G was significantly less than their untreated counterparts (p < 0.05). Ultimate load to failure of the MGR‐C group was significantly greater than the TGR‐C group (p < 0.05), but no significant difference in stiffness was found between these two groups. The modified techniques cannot only improve tendon gliding abilities but can also improve breaking strength. Additionally, surface modification with cd‐SF‐G significantly decreased the work of flexion. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:731–737, 2015.
The effect of tendon excursion velocity on longitudinal median nerve displacement: Differences between carpal tunnel syndrome patients and controls
Filius, Anika , Thoreson, Andrew R. , Passe, Sandra, Zhao, Chunfeng , An, Kai‐Nan, Amadio, Peter C. , Wang, Yuexiang , An, Kai‐Nan

Mayo Clinic

Journal of Orthopaedic Research | January 29, 2015 | Volume: 33 | Issue: 4 | Pages: 483-487

10.1002/jor.22804 | PMID 25640903 Get It

ABSTRACTThe subsynovial connective tissue (SSCT) is a viscoelastic structure connecting the median nerve (MN) and the flexor tendons in the carpal tunnel. Increased strain rates increases stiffness in viscoelastic tissues, and thereby its capacity to transfer shear load. Therefore, tendon excursion velocity may impact the MN displacement. In carpal tunnel syndrome (CTS) the SSCT is fibrotic and may be ruptured, and this may affect MN motion. In this study, ultrasonography was performed on 14 wrists of healthy controls and 25 wrists of CTS patients during controlled finger motions performed at three different velocities. Longitudinal MN and tendon excursion were assessed using a custom speckle tracking algorithm and compared across the three different velocities. CTS patients exhibited significantly less MN motion than controls (p ≤ 0.002). While in general, MN displacement increased with increasing tendon excursion velocity (p ≤ 0.031). These findings are consistent with current knowledge of SSCT mechanics in CTS, in which in some patients the fibrotic SSCT appears to have ruptured from the tendon surface. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:483–487, 2015.
Collagen gel contraction as a measure of fibroblast function in an animal model of subsynovial connective tissue fibrosis
Yang, Tai‐Hua , Thoreson, Andrew R. , Gingery, Anne , Passe, Sandra, An, Kai‐Nan, Zhao, Chunfeng , Amadio, Peter C. , Larson, Dirk R. , An, Kai‐Nan , Gingery, Anne

Mayo Clinic

Journal of Orthopaedic Research | January 28, 2015 | Volume: 33 | Issue: 5 | Pages: 668-674

10.1002/jor.22835 | PMID 25626430 Get It

ABSTRACTCarpal tunnel syndrome (CTS) is a peripheral neuropathy characterized by non‐inflammatory fibrosis of the subsynovial connective tissues (SSCT). A rabbit model of CTS was developed to test the hypothesis that SSCT fibrosis causes the neuropathy. We used a cell‐seeded collagen‐gel contraction model to characterize the fibrosis in this model in terms of cellular mechanics, specifically to compare the ability of SSCT cells from the rabbit model and normal rabbits to contract the gel, and to assess the effect of transforming growth factor‐β1,which is upregulated in CTS, on these cells. SSCT fibrosis was induced in six retired breeder female rabbits which were sacrificed at 6 weeks (N = 3) and 12 weeks (n = 3). An additional two rabbits served as controls. SSCT was harvested according to a standard protocol. Gels seeded with SSCT cells from rabbits sacrificed at 6 weeks had significantly higher tensile strength (p < 0.001) and Young's modulus (p < 0.001) than gels seeded with cells from rabbits sacrificed at 12 weeks or control animals. TGF‐β1 significantly increased the decay time constant (p < 0.001), tensile strength (p < 0.001), and Young's modulus (p < 0.001) regardless of the cell source. This model may be useful in screening therapeutic agents that may block SSCT fibrosis, identifying possible candidates for CTS treatment. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:668–674, 2015.
Effects of trypsinization and mineralization on intrasynovial tendon allograft healing to bone
Alphen, Nick A. van, Thoreson, Andrew R. , Chen, Qingshan , An, Kai‐Nan, Amadio, Peter C. , Zhao, Chunfeng , Qu, Jin, Qu, Jin , An, Kai‐Nan , Schmid, Thomas M

Mayo Clinic

Journal of Orthopaedic Research | January 21, 2015 | Volume: 33 | Issue: 4 | Pages: 468-474

10.1002/jor.22779 | PMID 25611186 Get It

ABSTRACTThe purpose of the current study was to develop a novel technology to enhance tendon‐to‐bone interface healing by trypsinizing and mineralizing (TM) an intrasynovial tendon allograft in a rabbit bone tunnel model. Eight rabbit flexor digitorum profundus (FDP) tendons were used to optimize the trypsinization process. An additional 24 FDP tendons were stratified into control and TM groups; in each group, 4 tendons were used for in vitro evaluation of TM and 8 were transplanted into proximal tibial bone tunnels in rabbits. The samples were evaluated histologically and with mechanical testing at postoperative week 8. Maximum failure strength and linear stiffness were not significantly different between the control and TM tendons. A thin fibrous band of scar tissue formed at the graft‐to‐bone interface in the control group. However, only the TM group showed obvious new bone formation inside the tendon graft and a visible fibrocartilage layer at the bone tunnel entrance. This study is the first to explore effects of TM on the intrasynovial allograft healing to a bone tunnel. TM showed beneficial effects on chondrogenesis, osteogenesis, and integration of the intrasynovial tendon graft, but mechanical strength was the same as the control tendons in this short‐term in vivo study. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:468–474, 2015.
Biomechanical aspects of trigger finger – which changed first, the pulley or the tendon?
Lu, Szu‐Ching , Su, Fong‐Chin , Zhao, Chunfeng , Thoreson, Andrew R. , Jou, I‐Ming , An, Kai‐Nan

Mayo Clinic

Journal of Biomechanical Science and Engineering | September 15, 2014 | Volume: 9 | Issue: 2 | Pages: 13-00237-13-00237

10.1299/jbse.13-00237 Get It