Citations

Clear

37 citation(s) found for "Stybayeva, Gulnaz".

Automated Microfluidic System with Active Mixing Enables Rapid Analysis of Biomarkers in 5 μL of Whole Blood
Gonzalez‐Suarez, Alan M. , Carey, William A., Revzin, Alexander , Revzin, Alexander , Gonzalez-Suarez, Alan M , Stybayeva, Gulnaz

Mayo Clinic

Analytical Chemistry | May 23, 2022 | Volume: 94 | Issue: 27 | Pages: 9706-9714

10.1021/acs.analchem.2c01139 | PMID 35604796 Get It

Nanoparticle-Enabled Multiplexed Electrochemical Immunoassay for Detection of Surface Proteins on Extracellular Vesicles
Lee, Seonhwa , Verkhoturov, Stanislav V. , Verkhoturov, Dmitriy S., Eller, Michael J. , Revzin, Alexander , Crulhas, Bruno P. , Eller, Michael J , Schweikert, Emile A , Revzin, Alexander , Šuvakov, Sonja , Malhi, Harmeet , Garovic, Vesna D. , Stybayeva, Gulnaz

Mayo Clinic

ACS Applied Materials & Interfaces | October 28, 2021 | Volume: 13 | Issue: 44 | Pages: 52321-52332

10.1021/acsami.1c14506 | PMID 34709783 Get It

Hepatocyte cultures: From collagen gel sandwiches to microfluidic devices with integrated biosensors
Hoyos‐Vega, José M. de , Hong, Hye Jin , Stybayeva, Gulnaz , Revzin, Alexander , de Hoyos-Vega, Jose M , Stybayeya, Gulnaz

Mayo Clinic

APL Bioengineering | October 14, 2021 | Volume: 5 | Issue: 4 | Pages: No page available

10.1063/5.0058798 | PMID 34703968 Get It

Hepatocytes are parenchymal cells of the liver responsible for drug detoxification, urea and bile production, serum protein synthesis, and glucose homeostasis. Hepatocytes are widely used for drug toxicity studies in bioartificial liver devices and for cell-based liver therapies. Because hepatocytes are highly differentiated cells residing in a complex microenvironment in vivo, they tend to lose hepatic phenotype and function in vitro. This paper first reviews traditional culture approaches used to rescue hepatic function in vitro and then discusses the benefits of emerging microfluidic-based culture approaches. We conclude by reviewing integration of hepatocyte cultures with bioanalytical or sensing approaches.
Microfluidic confinement enhances phenotype and function of hepatocyte spheroids
Choi, Jong Hoon , Loarca, Lorena, Hoyos‐Vega, José M. de , Dadgar, Neda , Loutherback, Kevin , Shah, Vijay H. , Revzin, Alexander , De Hoyos-Vega, Jose M, de Hoyos-Vega, Jose M , Stybayeva, Gulnaz

Mayo Clinic

American Journal of Physiology-Cell Physiology | July 22, 2020 | Volume: 319 | Issue: 3 | Pages: C552-C560

10.1152/ajpcell.00094.2020 | PMID 32697600 Get It

A number of cell culture approaches have been described for maintenance of primary hepatocytes. Forming hepatocytes into three-dimensional (3-D) spheroids is one well-accepted method for extending epithelial phenotype of these cells. Our laboratory has previously observed enhanced function of two-dimensional (2-D, monolayer) hepatocyte cultures in microfluidic devices due to increased production of several hepato-inductive growth factors, including hepatocyte growth factor (HGF). In the present study, we wanted to test a hypothesis that culturing hepatocyte spheroids (3-D) in microfluidic devices will also result in enhanced phenotype and function. To test this hypothesis, we fabricated devices with small and large volumes. Both types of devices included a microstructured floor containing arrays of pyramidal wells to promote assembly of hepatocytes into spheroids with individual diameters of ~100 µm. The hepatocyte spheroids were found to be more functional, as evidenced by higher level of albumin synthesis, bile acid production, and hepatic enzyme expression, in low-volume compared with large-volume devices. Importantly, high functionality of spheroid cultures correlated with elevated levels of HGF secretion. Although decay of hepatic function (albumin secretion) was observed over the course 3 wk, this behavior could be abrogated by inhibiting TGF-β1 signaling. With TGF-β1 inhibitor, microfluidic hepatocyte spheroid cultures maintained high and stable levels of albumin synthesis over the course of 4 wk. To further highlight utility of this culture platform for liver disease modeling, we carried out alcohol injury experiments in microfluidic devices and tested protective effects of interleukin-22: a potential therapy for alcoholic hepatitis.
Fabrication of composite microfluidic devices for local control of oxygen tension in cell cultures
Gao, Yandong , Revzin, Alexander , Stybayeva, Gulnaz

Mayo Clinic

Lab on a Chip | December 5, 2018 | Volume: 19 | Issue: 2 | Pages: 306-315

10.1039/c8lc00825f | PMID 30547179 Get It

We developed a microfabrication strategy that integrated two materials with different gas permeability in a single microfluidic chip to enable local control of oxygen tension for cell cultures.
Nanowire Aptasensors for Electrochemical Detection of Cell-Secreted Cytokines
Liu, Ying , Rahimian, Ali , Vu, Tam , Crulhas, Bruno P. , Imanbekova, Meruyert , Revzin, Alexander , Revzin, Alexander , Krylyuk, Sergiy G. , Stybayeva, Gulnaz , Shin, Dong‐Sik , Davydov, Albert V.

Mayo Clinic

ACS Sensors | October 9, 2017 | Volume: 2 | Issue: 11 | Pages: 1644-1652

10.1021/acssensors.7b00486 | PMID 28991491 Get It

Harnessing endogenous signals from hepatocytes using a low volume multi-well plate
Gheibi, Pantea, Son, Kyung Jin, Revzin, Alexander , Stybayeva, Gulnaz

Mayo Clinic

Integrative Biology | March 13, 2017 | Volume: 9 | Issue: 5 | Pages: 427-435

10.1039/c7ib00010c | PMID 28353687 Get It