Citations

Clear

72 citation(s) found for "Meeusen, J".

A-221 Evaluation of Apolipoprotein B Equivalent Low-density Lipoprotein Cholesterol Measurements
Hornseth, Jean M, Jaffe, Allan S. , Meeusen, Jeffrey W. , Donato, Leslie J. , Jaffe, Allan S.

Mayo Clinic

Clinical Chemistry | September 27, 2023 | Volume: 69 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvad097.199 Get It

Abstract Background Low-density lipoprotein cholesterol (LDL-C) is the primary biomarker for assessing risk for atherosclerotic cardiovascular disease (ASCVD). However, multiple large studies have demonstrated greater accuracy using Apolipoprotein B (apoB). One obstacle to its widespread use is the lack of guideline endorsed apoB treatment targets. A recently published solution has proposed using population percentiles to calculate LDL-C using apoB values (PMID: 36366949). The LDL-C concentration correlated to an individual’s ApoB percentile may more appropriately reflect ASCVD risk compared to lipid panel LDL-C. Here we evaluated this approach using a cohort where LDL-C was measured with the gold-standard beta-quantification method (LDL-CBQ). Method Results from clinically ordered apoB, LDL-CBQ, and lipid panel were included (n = 18 852). Samples with triglycerides >1000 mg/dL or LpX were excluded. Total cholesterol, high-density lipoprotein cholesterol (HDL-C), triglycerides (TG), and apoB were measured using Roche Cobas c501 analyzers. LDL-CBQ was performed using Beckman LE-80K ultracentrifuge and dextran sulfate-Mg/Cl precipitation. ApoB equivalent LDL-C (eqLDL-CapoB) was calculated according to linear regression of LDL-C percentiles against apoB percentiles described by the equation eqLDL-CapoB = 1.45(apoB)-25. Concordance was determined based on clinical thresholds for LDL-CBQ and eqLDL-CapoB. Results Median (IQR) apoB and LDL-CBQ was 98 (79−119) mg/dL and 120 (94−150) mg/dL, respectively. LDL-CBQ and eqLDL-CapoB were concordant in 60% of samples overall. Discordance between eqLDL-CapoB and LDL-CBQ shifted from primarily overestimating to underestimating as LDL-CBQ increased. Discordant eqLDL-CapoB was directly associated with TG and inversely associated with HDL-C. Conclusion The eqLDL-CapoB calculation is a useful tool to present apoB results in a more familiar context of LDL-C-equivalent units. The concordance findings largely confirm previously published results using eqLDL-CapoB. Furthermore, the pattern of HDL-C and TG suggests that a discordantly elevated eqLDL-CapoB is an indicator of a higher risk lipid profile. More investigation is needed to determine if eqLDL-CapoB is appropriate for widespread adoption.
B-044 Analytical validation of an serum glycerol measured by nuclear magnetic resonance spectroscopy NMR
Wang, Qin , Scott, Renee, Meeusen, J, Donato, Leslie J.

Mayo Clinic

Clinical Chemistry | September 27, 2023 | Volume: 69 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvad097.387 Get It

Abstract Background Glycerol kinase deficiency (GKD) is a rare X-linked recessive disorder biochemically characterized by hyperglycerolaemia. Adults with GKD are usually asymptomatic. However, they often present with pseudohypertriglyceridemia because most clinical triglyceride methods measure enzymatically generated glycerol from triglycerides. Currently, assays for measuring plasma glycerol are lacking. We describe a preliminary validation of glycerol measured by nuclear magnetic resonance spectroscopy (NMR). Methods Serum glycerol was measured by NMR (Numares AG, Regensberg, Germany) using a Ascend 600 NMR (Bruker, Billerica, MA). Stability and matrix effects were determined by repeat measurement of 10 freshly collected samples following various storage conditions. Normal donors were recruited for reference interval (n = 143). Analytical specificity was assessed by spiking red cell lysate, bilirubin and intralipid. Precision was assessed by measuring three pools five times for five days. Accuracy was performed by spiking known concentrations of glycerol. Accuracy was assessed using an enzymatic method (Randox Laboratories, Ltd. County Antrim, UK) on a Roche Cobas c501 (Roche Diagnostics, Indianapolis, IN) as reference. Results Measured glycerol increased over time in both serum and plasma, however, prepared samples were stable on the instrument for up to 24 hours. Measured glycerol was not impacted by hemoglobin (1000 mg/dL) or bilirubin (625 mg/dL), however, spiking Intralipid® prevented any measurement. NMR and enzymatic assays strongly correlated, with a constant bias (Table 1). Repeatability and reproducibility were <10% CV and % recovery from glycerol standard were >80% for all concentrations. Conclusion Pre-analytical stability, imprecision and accuracy were acceptable for clinical measurement of glycerol using NMR. While there is a significant systematic bias with enzymatic methods, further studies in normal and disease populations will be necessary to determine clinical impact.
A-127 Bias and Precision of a NMR-based GFR Estimating Equation in Kidney Transplant Recipients
Santamaría, A N Schwäble, Meeusen, J, Scott, Rodney J. , Grassi, M , Schiffer, Eric, Santamaría, Amauri Schwäble , Schwäble Santamaria, Amauri , Lieske, John C. , Robertson, A N, Grassi, M

Mayo Clinic

Clinical Chemistry | September 27, 2023 | Volume: 69 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvad097.117 Get It

Abstract Background An accurate and reliable measurement of glomerular filtration rate (GFR) is essential to monitor for rejection and disease progression post-kidney transplantation. Measured GFR (mGFR) is the current gold standard. However, it has scarce availability at many centers and is labor intensive. Newer estimated GFR (eGFR) methods containing cystatin-C and/or other biomarkers have not been clinically validated in a post-transplant cohort. In this study, we evaluated a new NMR-based GFR (GFRNMR) equation that contains serum creatinine, cystatin C, myoinositol, and valine in post-kidney transplant recipients in a clinical routine setting. Methods Venipuncture for serum collection was performed immediately prior to mGFR measurement with urinary iothalamate clearance in 67 post-kidney transplant recipients. Serum was stored at 4°C and measured by NMR no later than four days after collection. eGFR was assessed using the following equations: i) GFRNMR, ii) CKD-EPI2021Cr (creatinine) and iii) CKD-EPI2021Cr,Cys (creatinine and cystatin-C). Bias was calculated as “eGFR—mGFR” for all equations. The Bootstrap method was employed to assess pairwise significance levels between bias distributions interquartile ranges (IQR), and P-value correction was determined with the Benjamini & Hochberg method. Precision, which was defined as percentage of samples within ±30% and ±15% from the mGFR value (P30 and P15, respectively), was calculated for each equation. Pairwise comparisons were made using McNemar’s Chi-squared and Benjamini & Hochberg correction. Precision was defined as the proportion of eGFR values concordant with mGFR values by CKD clinical stage. Results P30 for GFRNMR was significantly higher than CKD-EPI2021 Cr,Cys (97% vs 84%, P < 0.01) and higher than CKD-EPI2021 Cr (88%, P = 0.08). Similarly, P15 for GFRNMR was 63%; higher than for CKD-EPI2021 Cr (54%, P = 0.35) and CKD-EPI2021 Cr,Cys (51%, P = 0.19). Bias IQR for GFRNMR was 9.5 mL/min/1.73 m2 (median bias 2.0 mL/min/1.73 m2); significantly smaller than for CKD-EPI2021 Cr (Bias IQR 15.55 mL/min/1.73 m2, P < 0.05; median bias 1.47 mL/min/1.73 m2), and smaller than CKD-EPI2021 Cr,Cys (Bias IQR 14.4 mL/min/1.73 m2, P = 0.09; median bias 2.3 mL/min/1.73 m2). A broad range of medications such as immune modulators, and comorbidities such as hypertension, thyroid dysfunction, and coronary artery disease, did not interfere with GFRNMR performance. Conclusion NMR-based eGFR was less biased, more precise, and more accurate compared to creatinine and cystatin-C CKD-EPI eGFR equations in a post-kidney transplant setting. These findings suggest GFRNMR may more closely resemble mGFR in post-transplant patients and warrants further study on its potential use to improve clinical management in this patient group.
A-203 An Equation based on the Standard Lipid Panel for Calculating Low-Density Lipoproteins-Triglycerides
Meeusen, Jeffrey W. , Jaffe, Allan S. , Remaley, Alan T. , Wolska, Anna , Sampson, Maureen , Donato, Leslie J. , Jaffe, Allan S.

Mayo Clinic

Clinical Chemistry | September 27, 2023 | Volume: 69 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvad097.182 Get It

Abstract Background There is growing evidence that low-density lipoprotein-triglyceride (LDL-TG) may be a better biomarker to define atherosclerotic cardiovascular disease (ASCVD) risk than LDL-cholesterol (LDL-C), which is currently used to stratify risk and as a treatment goal. Because LDL-TG typically requires additional advanced lipid testing, we developed an equation for estimating LDL-TG (eLDL-TG) from the results of the standard lipid panel. Methods Results from a general dyslipidemic population (N = 40 202), which were obtained with beta-quantification (BQ) reference method, were randomly divided into a training and validation datasets and used to develop the equation for estimating LDL-TG shown in Fig. 1A. Association of Sampson-NIH-LDL-C (NIH-LDL-C) and eLDL-TG with ASCVD risk markers was done in the National Heart and Nutrition Examination Survey (NHANES) (N = 37 053) and with ASCVD events in the Atherosclerosis Risk in Communities (ARIC) study (N = 14 749). Results The comparison between eLDL-TG and measured LDL-TG was only modest (R2 = 0.601, slope = 0.611), but eLDL-TG (Fig. 1B) showed better risk stratification than NIH-LDL-C (Fig. 1C) by survival curve analysis in ARIC. Moreover, receiver-operating characteristic (ROC) analysis showed that eLDL-TG was better than all other lipid-marker tests for ASCVD events (AUC: eLDL-TG = 0.633, HDL-C = 0.627, sdLDL-C = 0.621, remnant-cholesterol = 0.613, NonHDL-C = 0.613, TG = 0.603, apoB = 0.598, NIH-LDL-C = 0.590, TC = 0.568). In NHANES, eLDL-TG was more strongly associated with hypertriglyceridemia, obesity, diabetes, metabolic syndrome and increased high-sensitivity C-reactive protein than NIH-LDL-C. Inclusion of eLDL-TG in a Cox-Proportional Hazards Model along with other conventional risk factors (age, sex, race, diabetes, systolic blood pressure, smoking, HDL-C, and total cholesterol) did not further improve risk prediction. Conclusions Like LDL-C, LDL-TG can also be estimated from the results of the standard lipid panel. It is a better univariate risk marker than LDL-C and hence can be useful for initial ASCVD risk stratification.
A-208 An Improved Formula for Predicting Low LDL-C Based on an Enhanced Sampson-NIH Equation
Coverdell, Tatiana C., Meeusen, Jeffrey W. , Jaffe, Allan S. , Remaley, Alan T. , Sampson, Maureen , Donato, Leslie J. , Jaffe, Allan S.

Mayo Clinic

Clinical Chemistry | September 27, 2023 | Volume: 69 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvad097.187 Get It

Abstract Background Low-density lipoprotein cholesterol (LDL-C) is used to assess atherosclerotic cardiovascular disease (ASCVD) risk and to manage lipid-lowering therapy. Proprotein convertase subtilisin/kexin (type 9) serine protease (PCSK9) inhibitors decrease LDL-C by up to 70% when used in conjunction with statins. Due to cost, insurance companies restrict their use. To be eligible for PCSK9 therapy, a patient must have pre-existing ASCVD and LDL-C > 70 mg/dL, while on a maximally tolerated dose of statins. Most clinical laboratories calculate LDL-C by the Friedewald Equation (FWLDL-C), which utilizes results from the standard lipid panel (total cholesterol (TC), triglycerides (TG), and high-density lipoprotein cholesterol (HDL-C)). However, this often leads to an underestimation of LDL-C, especially when TG concentrations are elevated. More accurate equations have recently been developed, such as the Martin (MLDL-C), Sampson-NIH (SLDL-C) and extended Martin (ext-MLDL-C) equations. Using LDL-C determined by the beta-quantification reference method (BQ), we developed the following enhanced version of the Sampson-NIH Equation (eSLDL-C), which includes apoB as an independent variable: eSLDL-C = TC/1.15-(HDL-C)/1.25-TG/6.98-(TG × NonHDL-C)/1115 + TG2/8903.23 + (TG × ApoB)/1237 + ApoB/4.54–4.73 Methods Results for clinically ordered ApoB, BQ, and lipid panels were used. To test the accuracy of the various equations, we compared BQLDL-C to FWLDL-C, MLDL-C, extMLDL-C, SLDL-C and eSLDL-C by regression analysis (N = 12 101, TG < 800). Accuracy of each equation was compared to the BQ reference method for classifying patients (LDL-C ≤ 150, n = 9374) as either being below or above the 70 mg/dL treatment decision threshold for PCSK9 therapy. Results The eSLDL-C equation performed substantially better than the other equations for estimating low LDL-C (BQLDL-C ≤ 100 mg/dL, TG 5–800 mg/dL, n = 4115), with a mean absolute difference (MAD) of 3.80 mg/dL (compared to SLDL-C: 6.05; FWLDL-C: 8.71; MLDL-C: 6.43; extMLDL-C: 6.39). It also had the best overall normalized Matthew’s Correlation Coefficient (nMCC) for the best balance of sensitivity and specificity for identifying patients that are above the 70 mg/dL treatment threshold (eSLDL-C-94.7% (92.2% spec, 98.5% sen), SLDL-C-90.7% (94.8% spec, 95.5% sen), FWLDL-C-88.2% (98.0% spec, 92.7% sen), MLDL-C-90.3% (88.9% spec, 96.5% sen), and extMLDL-C-90.1% (88.4% spec, 96.5% sen)). In our dataset with 1125 subjects being below the 70 mg/dL threshold by BQLDL-C, FWLDL-C misclassified an additional 601 subjects below this threshold (Negative Predictive Value 65%). MLDL-C and extMLDL-C misclassified 289 subjects falsely low, whereas eSLDL-C only has 126 subjects falsely classified lower than the 70 mg/dL threshold. Conclusion We show that the enhanced Sampson-NIH equation, which includes apoB, estimates low LDL-C more accurately than other equations. The use of the new equation would improve access to those patients who might benefit from PCSK9 therapy but have falsely low LDL-C by the FWLDL-C equation or other LDL-C equations. The new equation is also more specific than the MLDL-C and extMLDL-C equations and would, therefore, also reduce the overutilization of PCSK9 therapy by these particular equations for those patients who do not require it, according to the reference BQ method and current guidelines.
A-207 Analytical Validation of Helena SPIFE Touch to Determine ApoB-Containing Lipoproteins Lp(a)-P, LDL-P and VLDL-P
Scott, Rodney J. , Jaffe, Allan S. , Meeusen, J, Vasile, Vlad C. , Donato, Leslie J. , Jaffe, Allan S.

Mayo Clinic

Clinical Chemistry | September 27, 2023 | Volume: 69 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvad097.186 Get It

Abstract Background Elevated Lp(a) is an independent risk factor for atherosclerotic (ASCVD) events and associates with aortic stenosis. Accurate immunochemical measurement of Lp(a) is complicated by heterogeneity of Lp(a) molecular size. The objective of this study was to validate the analytical performance of an electrophoretic assay for measurement of ApoB-containing lipoprotein particles including Lp(a)-P, LDL-P, and VLDL-P and to compare results to other standard clinical methods. Method Lp(a)-P, LDL-P, and VLDL-P were quantified by electrophoretic serum separation followed by immuno-staining with an ApoB antibody using the SPIFE Touch (Helena Laboratories, Beaumont, TX). Stability was evaluated by comparison to results at time zero (n = 10). Precision was assessed by 5 measurements twice daily for five days. Limit of quantitation (LoQ) was determined by 20 replicate measurements. Linearity was assessed by mixing high and low concentrations at various ratios. Accuracy was assessed by split sample comparison (n = 126) with Helena Laboratories. Lp(a)-P and LDL-P results were compared to nuclear magnetic resonance (NMR) using a Bruker Ascend 600 NMR (Bruker, Billerica, MA) with AXINON software (numares, AG, Regensberg, Germany) (n = 114). Lp(a)-P is included with LDL-P by NMR. Therefore, the SPIFE Lp(a)-P + LDL-P was compared to NMR LDL-P. SPIFE Lp(a)-P was compared directly to Roche cobas c501 Lp(a) immunoassay calibrated to molar units (Roche Diagnostics, Indianapolis, IN) (n = 126). Results The analytical performance of Lp(a)-P, LDL-P, and VLDL-P measured on the SPIFE Touch met all acceptance criteria. Bias to the reference method was <20% with R2 > 0.98. All analytes were stable 14 days refrigerated and 14 days frozen. Lipoprotein particle measurements on SPIFE Touch correlated to those obtained by both NMR and Roche assays. Conclusion The analytical performance of the SPIFE Touch for measuring the concentration of ApoB-containing lipoproteins is acceptable. Further studies are needed to determine clinical implications and utility compared to NMR and Roche assays.
Performance of Nuclear Magnetic Resonance-Based Estimated Glomerular Filtration Rate in a Real-World Setting
Santamaría, Amauri Schwäble , Grassi, M , Meeusen, Jeffrey W. , Lieske, John C. , Scott, Renee, Robertson, Andrew, Schiffer, Eric, Schwäble Santamaria, Amauri , Grassi, Marcello , Lieske, John C

Mayo Clinic

Bioengineering | June 14, 2023 | Volume: 10 | Issue: 6 | Pages: 717

10.3390/bioengineering10060717 | PMID 37370648 Get It

An accurate estimate of glomerular filtration rate (eGFR) is essential for proper clinical management, especially in patients with kidney dysfunction. This prospective observational study evaluated the real-world performance of the nuclear magnetic resonance (NMR)-based GFRNMR equation, which combines creatinine, cystatin C, valine, and myo-inositol with age and sex. We compared GFRNMR performance to that of the 2021 CKD-EPI creatinine and creatinine-cystatin C equations (CKD-EPI2021Cr and CKD-EPI2021CrCys), using 115 fresh routine samples of patients scheduled for urinary iothalamate clearance measurement (mGFR). Median bias to mGFR of the three eGFR equations was comparably low, ranging from 0.4 to 2.0 mL/min/1.73 m2. GFRNMR outperformed the 2021 CKD-EPI equations in terms of precision (interquartile range to mGFR of 10.5 vs. 17.9 mL/min/1.73 m2 for GFRNMR vs. CKD-EPI2021CrCys; p = 0.01) and accuracy (P15, P20, and P30 of 66.1% vs. 48.7% [p = 0.007], 80.0% vs. 60.0% [p < 0.001] and 95.7% vs. 86.1% [p = 0.006], respectively, for GFRNMR vs. CKD-EPI2021CrCys). Clinical parameters such as etiology, comorbidities, or medications did not significantly alter the performance of the three eGFR equations. Altogether, this study confirmed the utility of GFRNMR for accurate GFR estimation, and its potential value in routine clinical practice for improved medical care.
Estimating glomerular filtration rate with new equations: can one size ever fit all?
Kasozi, Ramla N. , Meeusen, Jeffrey W. , Lieske, John C. , Lieske, John C

Mayo Clinic

Critical Reviews in Clinical Laboratory Sciences | June 1, 2023 | Volume: 60 | Issue: 7 | Pages: 549-559

10.1080/10408363.2023.2214812 | PMID 37259709 Get It

Accuracy and Clinical Impact of Estimating Low-Density Lipoprotein-Cholesterol at High and Low Levels by Different Equations
Sampson, Maureen , Wolska, Anna , Cole, Justine , Zubirán, Rafael , Otvos, James D. , Meeusen, Jeff W., Jaffe, Allan S. , Remaley, Alan T. , Donato, Leslie J. , Meeusen, Jeffrey W. , Jaffe, Allan S.

Mayo Clinic

Biomedicines | December 7, 2022 | Volume: 10 | Issue: 12 | Pages: 3156

10.3390/biomedicines10123156 | PMID 36551912 Get It

New more effective lipid-lowering therapies have made it important to accurately determine Low-density lipoprotein-cholesterol (LDL-C) at both high and low levels. LDL-C was measured by the β-quantification reference method (BQ) (N = 40,346) and compared to Friedewald (F-LDL-C), Martin (M-LDL-C), extended Martin (eM-LDL-C) and Sampson (S-LDL-C) equations by regression analysis, error-grid analysis, and concordance with the BQ method for classification into different LDL-C treatment intervals. For triglycerides (TG) < 175 mg/dL, the four LDL-C equations yielded similarly accurate results, but for TG between 175 and 800 mg/dL, the S-LDL-C equation when compared to the BQ method had a lower mean absolute difference (mg/dL) (MAD = 10.66) than F-LDL-C (MAD = 13.09), M-LDL-C (MAD = 13.16) or eM-LDL-C (MAD = 12.70) equations. By error-grid analysis, the S-LDL-C equation for TG > 400 mg/dL not only had the least analytical errors but also the lowest frequency of clinically relevant errors at the low (<70 mg/dL) and high (>190 mg/dL) LDL-C cut-points (S-LDL-C: 13.5%, F-LDL-C: 23.0%, M-LDL-C: 20.5%) and eM-LDL-C: 20.0%) equations. The S-LDL-C equation also had the best overall concordance to the BQ reference method for classifying patients into different LDL-C treatment intervals. The S-LDL-C equation is both more analytically accurate than alternative equations and results in less clinically relevant errors at high and low LDL-C levels.
More Than Just Heart Disease: Predicting the Presence of Lipoprotein X using Lipid Panel Results
Fyffe-Freil, Ria , Vanderboom, Patrick M. , Remaley, Alan T. , Meeusen, Jeffrey W. , Sampson, Maureen , Donato, Leslie J.

Mayo Clinic

American Journal of Clinical Pathology | November 9, 2022 | Volume: 158 | Issue: Supplement_1 | Pages: S4-S4

10.1093/ajcp/aqac126.006 Get It

Abstract Cholestatic liver diseases, such as primary sclerosing cholangitis and primary biliary cirrhosis, can lead to serum accumulation of lipoprotein X (LpX). LpX is a multilamellar particle high in cholesterol but lacking structural apolipoproteins A1 or B. The absence of ApoB results in no negative feedback on cholesterol biosynthesis and prevents LpX clearance from the liver. While clinical signs and symptoms typically precede laboratory findings, it is possible that in medically complex patients the identification of LpX could be the first observation of cholestatic liver disease. Traditional laboratory methods are insufficient to identify LpX as it is of similar density to low-density lipoprotein (LDL). LpX contains a high concentration of cholesterol which is erroneously reported as LDL-C by routine clinical methods. As LpX is a rare complication of liver disease, clinicians may presume the elevation is a coincidental familial hypercholesterolemia rather than a sequela of liver disease. Currently, lipoprotein gel electrophoresis is the only laboratory method to identify LpX. In this method only performed in specialty lipid laboratories, LpX is readily identified by its unique reverse electrophoretic mobility relative to other lipoproteins. The objective of this study was to characterize lipid panels from LpX-positive samples and develop a suitable mechanism to identify LpX-containing samples with good clinical validity. From 21,377 clinical electrophoresis results reported between Nov 2011 to Nov 2021, LpX was identified in 157 serum samples. Overall, patients with LpX were younger (median 44y vs. 55y, p&lt;0.0001) with significantly higher total cholesterol (812mg/dL vs 190mg/dL, p&lt;0.0001) and lower high density lipoprotein-cholesterol (HDL-C; 3mg/dL vs 45mg/dL, p&lt;0.0001). Data were randomly split (70/30) into training (n=14,964) and testing (n=6,413) cohorts. Receiver operator characteristic curve analysis identified optimal thresholds of 22.5 mg/dL HDL-C (AUC = 0.94) and 378.5 mg/dL total cholesterol (AUC = 0.91), as well as a nonHDL-C/HDL-C ratio of 9.2 (AUC = 0.995). Applying these cutoffs to the testing cohort achieved a sensitivity/specificity of 98%/81% for HDL-C, 96%/87% for total cholesterol, and 98%/94% for nonHDL-C/HDL-C ratio. A multivariate model combining these three parameters showed a sensitivity/specificity of 97%/85%, respectively. In conclusion, low HDL-C, elevated total cholesterol and a ratio of nonHDL-C/HDL-C &gt;9.2 are associated with the presence of LpX. The ratio of nonHDL-C/HDL-C is the most sensitive and specific predictor of LpX. If confirmed in other cohorts, laboratories could include a reporting comment on lipid panels with a nonHDL-C/HDL-C ratio &gt;9.2 cautioning a high suspicion for the presence of LpX and recommending confirmatory testing. It may also be prudent to caution that LDL-C results may not be accurate. In conclusion, identifying patients with high suspicion of LpX based on abnormal lipid panel results may aide in clinical diagnosis, even when an assay to detect LpX is not readily available.