Citations

Clear

35 citation(s) found for "Herman, Michael".

Patient‐specific daily pretreatment setup protocol using electronic portal imaging for radiation therapy
Wittmer, Michael H., Pisansky, Thomas M. , Kruse, Jon J. , Herman, Michael

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 22, 2007 | Volume: 6 | Issue: 4 | Pages: 1-13

10.1120/jacmp.v6i4.1954 | PMID 16421496 Get It

The purpose of this study was to evaluate electronic portal imaging (EPI) as a means of identifying and correcting field displacement in patients with problematic external beam radiotherapy setups. Fourteen patients with problematic setups were identified for pretreatment daily EPI beam monitoring as part of a physician‐directed therapist intervention protocol. Pretreatment EPIs were used to realign fields as necessary to bring the setup within the physician‐prescribed tolerance level. For comparison, daily EPIs were available for 12 control patients who had no particular setup difficulties and for whom online beam realignment was not made. Anatomy‐matching software was used to measure setup variation along medial‐lateral, superior‐inferior, and anterior‐posterior axes. Online field realignment yielded a significant improvement when comparing initial and final setup variations. The mean standard deviation of setup displacement averaged over three axes was reduced from 6.4 mm to 3.1 mm after realignment. The final variation of protocol patients was comparable to that of control patients. In conclusion, EPI provided effective means to perform online beam realignment in a group of difficult‐to‐position patients. This procedure resulted in a reduction in setup displacement that was statistically significant, clinically relevant, and approached that of a more typical patient group.PACS number: 87.53.Oq
A buccal mucosa carcinoma treated with high dose rate brachytherapy
Prisciandaro, Joann I. , Foote, Robert L. , Herman, Michael , Lee, Sally J., LaJoie, Wayne N., Blarcom, Andrew B. Van, Yeakel, Peter D.

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 22, 2007 | Volume: 6 | Issue: 1 | Pages: 8-12

10.1120/jacmp.v6i1.2064 | PMID 15770193 Get It

This manuscript presents a case of early stage squamous cell carcinoma of the left buccal mucosa treated with intensity‐modulated radiation therapy (IMRT) followed by a high‐dose rate (HDR) brachytherapy boost. With limited literature available on HDR mold (stent) radiotherapy for oral cancer, a discussion on the issues encountered during treatment planning and delivery may prove to be insightful for facilities faced with a similar challenge.PACS numbers: 87.53.Jw, 87.53.Tf, 87.59.Ci, 87.59.Fm
Utilizing an electronic portal imaging device to monitor light and radiation field congruence
Prisciandaro, Joann I. , Herman, Michael , Kruse, Jon J.

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 22, 2007 | Volume: 4 | Issue: 4 | Pages: 315-320

10.1120/jacmp.v4i4.2502 | PMID 14604421 Get It

A method to investigate light and radiation field congruence utilizing a commercially available amorphous silicon electronic portal imaging device (EPID) was developed. This method employed an EPID, the associated EPI software, and a diamond‐shaped template. The template was constructed from a block tray in which Sn/Pb wires, 1 mm in diameter, were embedded into a diamond shaped groove milled into the tray. The collimator jaws of the linac were aligned such that the light field fell directly on the corners of the diamond. A radiation detection algorithm within the EPI software determined the extent of the radiation field. The light and radiation field congruence was evaluated by comparing the vertexes of the diamond reference structure to the detected radiation field. In addition, the digital jaw settings were recorded and later compared to the light field detected on the films and EPIs. Three linear accelerators were tracked for a period ranging from 2–8 months. Light radiation field congruence tests with films and EPIs were comparable, yielding a difference of less than 0.6 mm, well within the allowed 2‐mm tolerance. A disparity was observed in the magnitude of the detected light field. The X and Y dimensions of the light field measured with film differed by less than or equal to 1.4 mm from the digital collimator settings, whereas the values extracted from the EPIs differed by up to 2.5 mm. Based on these findings, EPIs were found to be a quick and reliable alternative to film for qualitative and relative analyses.PACS number(s): 87.53.Xd, 87.56.Fc, 87.53.Oq, 87.52.–g, 87.53.–j
Guide to clinical use of electronic portal imaging
Herman, Michael , Kruse, Jon J. , Hagness, C.R.

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 22, 2007 | Volume: 1 | Issue: 2 | Pages: 38-57

10.1120/jacmp.v1i2.2645 | PMID 11674818 Get It

The Electronic Portal Imaging Device (EPID) provides localization quality images and computer‐aided analysis, which should in principal, replace portal film imaging. Modern EPIDs deliver superior image quality and an array of analysis tools that improve clinical decision making. It has been demonstrated that the EPID can be a powerful tool in the reduction of treatment setup errors and the quality assurance and verification of complex treatments. However, in many radiation therapy clinics EPID technology is not in routine clinical use. This low utilization suggests that the capability and potential of the technology alone do not guarantee its full adoption. This paper addresses basic considerations required to facilitate clinical implementation of the EPID technology and gives specific examples of successful implementations. © 2000 American College of Medical Physics.PACS number(s): 87.53.–j, 87.57.–s
Reimbursement versus effort in medical physics practice in radiation oncology
Herman, Michael , Mills, Michael , Gillin, Michael T.

Mayo Clinic

Journal of Applied Clinical Medical Physics | February 22, 2007 | Volume: 4 | Issue: 2 | Pages: 179-187

10.1120/jacmp.v4i2.2533 | PMID 12777154 Get It

The changes in health care reimbursement have the potential to affect the availability of quality medical physicist service in patient care. A survey was conducted by the AAPM Professional Council and the ACMP to collect cost information for special medical physics consultation, CPT4‐77370 and continuing medical physics, CPT4‐77336. The data collected from the survey was compared to current reimbursement schemes for a number of special procedures. Under varying reimbursement schemes, the costs of the medical physics services provided cannot be recaptured by the institution. It remains important for medical physicists to assess our utilization of resources and allocation to each of the services we provide and to understand the implications of policy changes at the federal and local levels. PACS number(s): 87.90.+y, 87.53.–j