Citations

Clear

81 citation(s) found for "Grebe, S K".

Spectrum of Mutations Associated with Hereditary Erythrocytosis
Oliveira, Jennifer L. , Frederick, Lori, Coon, Lea M., Hein, Molly S., Patnaik, Mrinal M. , Tefferi, Ayalew , Pardanani, Animesh , Grebe, Stefan K., Viswanatha, David S., Hoyer, James D.

Mayo Clinic

Blood | October 11, 2019 | Volume: 126 | Issue: 23 | Pages: 2140-2140

10.1182/blood.v126.23.2140.2140 Get It

Abstract Background: Mechanisms of hereditary erythrocytosis have been elucidated recently. These include high oxygen affinity (HOA) hemoglobin (Hb) variants, bisphosphoglycerate mutase (BPGM) deficiency, abnormalities in the erythropoietin receptor (EPOR) and oxygen-sensing pathway (OSP) proteins prolyl hydroxylase domain-2 (PHD2), hypoxia-inducible factor-2 alpha subunit (HIF2A), and von Hippel-Lindau (VHL). We present our experience with these disorders. Methods: Evaluation of erythrocytosis patients' blood samples for HOA Hb variants by protein or DNA sequencing methods has been performed in our laboratory for over 30 years. Testing has included alkaline/acid electrophoresis, isoelectric focusing, capillary electrophoresis, high performance liquid chromatography, mass spectrometry and Sanger sequencing. BPGM deficiency was determined by enzyme activity assay and/or genetic testing. Since 2012 we have evaluated the EPOR, EGLN1 (PHD2), EPAS1(HIF2A), and VHL genes. Reflexive evaluations, which include testing for p50 and pertinent Sanger sequencing of HBB, HBA1, HBA2, EPOR (exon 8), EGLN1 (exons 1-5), EPAS1 (exon 12) and VHL, have been performed on a subset of cases. Genetic results were correlated with clinical and phenotypic data. Results: Retrospective database review identified 62 confirmed HOA Hb variants (48β, 14α) with clinical erythrocytosis (Table 1). Multiple Hb variants were silent on at least one protein method but showed decreased p50 values. One homozygous BPGM mutation case was identified. Of the 394 cases evaluated for EPOR and OSP abnormalities, 39 cases (10%) contained genetic alterations. Of these, 11 were known pathogenic mutations and 28 were novel alterations including 4 pathogenic, 12 likely pathogenic and 12 variants of unknown significance (VUS). Eighteen EGLN1, 10 EPAS1, and 7 EPOR alterations were detected, all heterozygous. Four VHL mutation cases were identified: 3 homozygous/compound heterozygous known mutations and one novel heterozygous VUS (p.R200Q). All EPOR mutations resulted in a premature stop codon. Most of the EPAS1 alterations were located near proline 531, although two predicted splice site disturbances were found. The EGLN1 alterations were novel, variable, and affect the enzyme's catalytic domain. All 4 VHL cases involved the R200 amino acid position in at least one allele. Serum Epo levels varied: decreased in EPOR (5/5); normal in PHD2 (11/11) and most HIF2A (6/7) and VHL (3/4) cases; increased in 1 HIF2A and 1 VHL case. p50 was normal in EPOR and OSP cases (31/31 tested). Conclusion: A spectrum of abnormalities was identified. Salient points include: 1) Diagnostically, a high index of suspicion for HOA Hb variants is required as they can give false negative results by routine protein detection methods. p50 and Epo levels were useful for triage. 2) Phenotypically, serum Epo levels were low in EPOR and normal in PHD2 and HIF2A cases. Unexpectedly, the two classic Chuvash polycythemia VHL cases were associated with normal Epo levels. 3) Mechanistically, the alterations were truncating in EPOR, variable and scattered in EGLN1 and clustered near proline 531 in EPAS1. VHL mutations were rare and consistently affected the R200 amino acid position in at least one allele. Novel alterations were frequent, especially in EGLN1. 4) Clinically, many patients were asymptomatic but a subset demonstrated recurrent headaches and one had chest pain. Clotting complications included cerebrovascular accident in one EPAS1 and EGLN1 case each and portal vein thrombosis in one EGLN1 case. Table 1. Clinically significant high oxygen affinity Hb variants at Mayo Clinic n Beta Alpha >30 Malmo Tarrant 10 - 20 Bethesda, San Diego, Andrew-Minneapolis, M-Saskatoon, Olympia, Syracuse, Abruzzo Dallas 5 - 10 Ty Gard, Ypsilanti, Alberta, Coimbra, North Chicago J-Cape Town 2 - 4 Brigham, Kempsey, Little Rock, Puttelange, Wood, Brisbane, Cowtown, Creteil, Linkoping, Osler, Potomac, Providence, Ranier, Sparta, Vanderbilt, Heathrow, Helsinki, Hiroshima, Homozygous HPFH, McKees-Rocks, Pierre Benite, Regina Chesapeake, Ethiopia, Chiapas, Columbia Missouri, Burlington, Legnano 1 Alcorn County*, Bologna-St. Orsola, Bunbury, Cambridge-MA, Cardarelli, Chandigarh, Johnstown, Nantes, Nebraska, Olomouc, Palmerston North, Pitie-Salpetriere, Saint-Jacques, South Milwaukee Linwood, Longview*, Milledgeville, Sarasota Springs, Voorhees * novel Disclosures Pardanani: Stemline: Research Funding.
Adrenal Cortical Carcinoma Associated With Lynch Syndrome: A Case Report and Review of Literature
Kaur, Ravinder Jeet , Pichurin, Pavel N. , Hines, Jolaine M., Grebe, Stefan K., Singh, Ravinder J. , Bancos, Irina

Mayo Clinic

Journal of the Endocrine Society | March 5, 2019 | Volume: 3 | Issue: 4 | Pages: 784-790

10.1210/js.2019-00050 | PMID 30963136 Get It

Applying Standard Clinical Chemistry Assay Validation to Droplet Digital PCR Quantitative Liquid Biopsy Testing
Mills, John R. , Campion, Michael B., Vidal‐Folch, Noemi, Voss, Jesse S. , Halling, Kevin C. , Highsmith, W. Edward, Liu, Minetta C. , Kipp, Benjamin R. , Grebe, Stefan K. , Vidal-Folch, Noemi, Grebe, Stefan K G, Milosevic, Dragana

Mayo Clinic

Clinical Chemistry | September 20, 2018 | Volume: 64 | Issue: 12 | Pages: 1732-1742

10.1373/clinchem.2018.291278 | PMID 30237149 Get It

AbstractBACKGROUNDDroplet digital PCR (ddPCR) is an emerging technology for quantitative cell-free DNA oncology applications. However, assay performance criteria must be established in a standardized manner to harness this potential. We reasoned that standard protocols used in clinical chemistry assay validation should be able to fill this need.METHODSWe validated KRAS, EGFR, and BRAF quantitative ddPCR assays based on the Clinical Laboratory Improvement Act regulations for laboratory-developed tests in clinical chemistry and the matching Clinical and Laboratory Standards Institute guidelines. This included evaluation of limit of the blank (LOB), limit of detection (LOD), limit of quantification (LOQ), intraassay and interassay imprecision, analytical range, dilution linearity, accuracy (including comparison with orthogonal platforms), reference range study, interference, and stability studies.RESULTSFor the ddPCR assays, the LOB was 4 mutant copies, LODs were 12 to 22 copies, and LOQs were 35 to 64 copies. The upper limit of the dynamic range was 30000 copies, and dilutions were linear down to the LOQs with good accuracy of spike recovery of Horizon reference material. Method comparisons with next-generation sequencing and an alternative ddPCR platform showed complete qualitative agreement and quantitative concordance, with slopes of 0.73 to 0.97 and R2s of 0.83 to 0.99. No substantial interferences were discovered. Wild-type copy numbers in plasma ranged from 462 to 6169/mL in healthy individuals.CONCLUSIONSStandard clinical chemistry assay validation protocols can be applied to quantitative ddPCR assays. This should facilitate comparison of the performance of different assays and allow establishment of minimal significant change thresholds in monitoring applications.
Development of Vitamin D Toxicity from Overcorrection of Vitamin D Deficiency: A Review of Case Reports
Galior, Kornelia , Grebe, Stefan K., Grebe, Stefan, Singh, Ravinder J.

Mayo Clinic

Nutrients | July 24, 2018 | Volume: 10 | Issue: 8 | Pages: 953

10.3390/nu10080953 | PMID 30042334 Get It

Over the past two decades, vitamin D level measurements have become some of the most frequently ordered tests in the laboratory. This increase is due to a growing awareness of widespread vitamin D deficiency and scientific data suggesting the beneficial effects of vitamin D in various diseases. A literature search was carried out in PubMed for cases reporting vitamin D intoxication and overdose. Thirteen articles were included in this review. Intoxication was severe in the reported cases. Patients presented with serum vitamin D concentrations ranging between 150 and 1220 ng/mL and serum calcium concentrations between 11.1 and 23.1 mg/dL. Most of the reported patients showed symptoms of vitamin D toxicity such as vomiting, dehydration, pain, and loss of appetite. The underlying causes included manufacturing errors, overdosing by patients or prescribers, and combinations of these factors. Our literature search highlights the fact that even though vitamin D intoxication is rare, it does occur and therefore patients and prescribers should be more cognizant of the potential dangers of vitamin D overdose.
In Reply
Hines, Jolaine, Grebe, Stefan K., Grebe, Stefan K G, Bancos, Irina , Singh, Ravinder

Mayo Clinic

Clinical Chemistry | May 30, 2018 | Volume: 64 | Issue: 8 | Pages: 1258-1259

10.1373/clinchem.2018.290205 | PMID 29848546 Get It

Methodology, Criteria, and Characterization of Patient-Matched Thyroid Cell Lines and Patient-Derived Tumor Xenografts
Rohl, Stephen D., Miller, James L. , Knauf, Jeffrey A. , Ryder, Mabel , Milosevic, Dragana , Netzel, Brian C., Grebe, Stefan K., Smallridge, Robert C., Copland, John A. , Marlow, Laura A. , Knauf, Jeffrey A , Fagin, James A. , Reddi, Honey V. , Ryder, Mabel

Mayo Clinic

The Journal of Clinical Endocrinology & Metabolism | May 25, 2018 | Volume: 103 | Issue: 9 | Pages: 3169-3182

10.1210/jc.2017-01845 | PMID 29846633 Get It

Genotype–phenotype correlation of hereditary erythrocytosis mutations, a single center experience
Oliveira, Jennifer L. , Coon, Lea M., Frederick, Lori, Hein, Molly S., Swanson, Kenneth C., Savedra, Michelle E., Porter, Tavanna R. , Patnaik, Mrinal M. , Tefferi, Ayalew , Pardanani, Animesh , Grebe, Stefan K., Viswanatha, David S., Hoyer, James D., Herrick, Jennifer L. , Frederick, Lori A, Hein, Molly

Mayo Clinic

American Journal of Hematology | May 23, 2018 | Volume: 93 | Issue: 8 | Pages: 1029-1041

10.1002/ajh.25150 | PMID 29790589 Get It

Hereditary erythrocytosis is associated with high oxygen affinity hemoglobin variants (HOAs), 2,3‐bisphosphoglycerate deficiency and abnormalities in EPOR and the oxygen‐sensing pathway proteins PHD, HIF2α, and VHL. Our laboratory has 40 years of experience with hemoglobin disorder testing and we have characterized HOAs using varied protein and molecular techniques including functional assessment by p50 analysis. In addition, we have more recently commenced adding the assessment of clinically relevant regions of the VHL , BPGM, EPOR , EGLN1 (PHD2), and EPAS1 (HIF2A) genes in a more comprehensive hereditary erythrocytosis panel of tests. Review of our experience confirms a wide spectrum of alterations associated with erythrocytosis which we have correlated with phenotypic and clinical features. Through generic hemoglobinopathy testing, we have identified 762 patients with 81 distinct HOA Hb variants (61 β, 20 α), including 12 that were first identified by our laboratory. Of the 1192 cases received for an evaluation specific for hereditary erythrocytosis, approximately 12% had reportable alterations: 85 pathogenic/likely pathogenic mutations and 58 variants of unknown significance. Many have not been previously reported. Correlation with clinical and phenotypic data supports an algorithmic approach to guide economical evaluation; although, testing is expanded if the suspected causes are negative or of uncertain significance. Clinical features are similar and range from asymptomatic to recurrent headaches, fatigue, restless legs, chest pain, exertional dyspnea and thrombotic episodes. Many patients were chronically phlebotomized with reported relief of symptoms.
Laboratory Services for Managing Thyroid Disease: Different and Common Viewpoints of American Thyroid Association Members and of Members of the Endocrine Division of the American Association for Clinical Chemistry
Grebe, Stefan K., A, on behalf of the American Thyroid, Grebe, Stefan K G, Algeciras‐Schimnich, Alicia

Mayo Clinic

Thyroid | November 8, 2017 | Volume: 27 | Issue: 12 | Pages: 1583-1585

10.1089/thy.2017.0387 | PMID 29113554 Get It

High-Resolution, Accurate-Mass (HRAM) Mass Spectrometry Urine Steroid Profiling in the Diagnosis of Adrenal Disorders
Hines, Jolaine M., Bancos, Cristian, Singh, Raman Deep , Avula, Aditya V, Grebe, Stefan K., Singh, Raman D., Bancos, Irina , Young, William F. , Singh, Ravinder J.

Mayo Clinic

Clinical Chemistry | August 16, 2017 | Volume: 63 | Issue: 12 | Pages: 1824-1835

10.1373/clinchem.2017.271106 | PMID 28814383 Get It

Abstract BACKGROUND Steroid profiling is a promising diagnostic tool with adrenal tumors, Cushing syndrome (CS), and disorders of steroidogenesis. Our objective was to develop a multiple-steroid assay using liquid-chromatography, high-resolution, accurate-mass mass spectrometry (HRAM LC-MS) and to validate the assay in patients with various adrenal disorders. METHODS We collected 24-h urine samples from 114 controls and 71 patients with adrenal diseases. An HRAM LC-MS method was validated for quantitative analysis of 26 steroid metabolites in hydrolyzed urine samples. Differences in steroid excretion between patients were analyzed based on Z-score deviation from control reference intervals. RESULTS Limits of quantification were 20 ng/mL. Dilution linearity ranged from 80% to 120% with means of 93% to 110% for all but 2 analytes. Intraassay and interassay imprecision ranged from 3% to 18% for all but 1 analyte. Control women had lower excretion of androgen and glucocorticoid precursors/metabolites than men (P < 0.001), but no difference in mineralocorticoids was seen (P = 0.06). Androgens decreased with age in both sexes (P < 0.001). Compared with patients with adrenocortical adenoma (ACA), patients with adrenocortical carcinoma (ACC) had 11 steroids with increased Z scores, especially tetrahydro-11-deoxycortisol (14 vs 0.5, P < 0.001), pregnanetriol (7.5 vs −0.4, P = 0.001), and 5-pregnenetriol (5.4 vs −0.4, P = 0.01). Steroid profiling also demonstrated metabolite abnormalities consistent with enzymatic defects in congenital adrenal hyperplasia and differences in pituitary vs adrenal CS. CONCLUSIONS Our HRAM LC-MS assay successfully quantifies 26 steroids in urine. The statistically significant differences in steroid production of ACC vs ACA, adrenal vs pituitary CS, and in congenital adrenal hyperplasia should allow for improved diagnosis of patients with these diseases.
First Steps toward Harmonization of LC-MS/MS Thyroglobulin Assays
Netzel, Brian C., Grant, Russell P. , Hoofnagle, Andrew N. , Rockwood, Alan L. , Shuford, Christopher M. , Grebe, Stefan K., Grebe, Stefan K G

Mayo Clinic

Clinical Chemistry | October 1, 2015 | Volume: 62 | Issue: 1 | Pages: 297-299

10.1373/clinchem.2015.245266 | PMID 26430076 Get It