Citations

Clear

33 citation(s) found for "Davis, Elizabeth J".

Outcomes of Patients Implanted Using a Left Thoracotomy Technique for a Miniaturized Centrifugal Continuous-Flow Pump
Sileshi, Bantayehu , O’Hara, Brian K., Haglund, Nicholas, Xu, Meng , Deegan, Robert , Stulak, John M., Kushwaha, Sudhir S. , Shaw, Andrew , Maltais, Simon, Davis, Mary Elizabeth

Mayo Clinic

ASAIO Journal | June 26, 2016 | Volume: 62 | Issue: 5 | Pages: 539-544

10.1097/mat.0000000000000407 | PMID 27347709 Get It

As ventricular-assist devices (VADs) are increasingly employed in heart failure management, a leading cause of mortality, new literature is consistently published on less-invasive implantation techniques. Although early perioperative outcomes have been shown to be favorable with minimally invasive left thoracotomy (LT) approaches compared with conventional sternotomy (CS), studies comparing long-term outcomes are lacking. We set out to evaluate long-term follow up between LT and CS approach. In a single center, retrospective review, data on patients with similar demographic profiles were collected. HeartWare (HVAD) implantation was performed by either CS or LT. Analysis was performed on perioperative adverse outcomes, and 6 month postoperative adverse events. Primary objectives of the study included comparative outcomes of morbidity and mortality between both groups at 180 days postimplantation. Eighty-one (n = 81) bridge to transplant (BTT) patients underwent CS or LT HVAD implantation. Perioperative transfusion (p = 0.04) favored the LT cohort compared with CS, with a median of 6 units and 8 units transfused for each group, respectively. No survival difference was observed between both groups at 6 months postimplantation (p = 0.52). Clinical outcomes at an average of 6 month follow up showed no difference in adverse events, including common postoperative VAD complications such as infection and right heart failure. Miniaturization of LVAD size and improvement in technology has allowed expansion of interest in alternative surgical approaches for HVAD implantation. For BTT patients, no difference in early outcome was observed 6 months after implantation using a left LT versus CS technique.
Outcomes After Concomitant Procedures with Left Ventricular Assist Device Implantation: Implications by Device Type and Indication
Maltais, Simon, Haglund, Nicholas, Pagani, Francis D. , Stulak, John M., Davis, Mary Elizabeth , Aaronson, Keith D. , Dunlay, Shannon M. , Pagani, Francis D

Mayo Clinic

ASAIO Journal | May 12, 2016 | Volume: 62 | Issue: 4 | Pages: 403-409

10.1097/mat.0000000000000383 | PMID 27164038 Get It

Guidelines for performing concomitant procedures (CPs) in patients undergoing continuous flow-left ventricular assist device (CF-LVAD) implantation are unclear. The impact of an increased surgical complexity outside the constraint of landmark clinical trials has not been reported. From May 2004 to December 2013, 614 patients (499 males, 81%) underwent CF-LVAD implant at our institutions. Median age was 57 ± 13 years and 364 (59%) were bridge to transplantation (BTT). Survival and device-related complications were analyzed and stratified based on the surgical intervention. A total of 398 patients (65%) underwent CF-LVAD implantation without CPs. The remaining patients (35%, n = 216) were grouped according to various CPs. Survival was comparable between groups and not influenced by the CP, device type, or indication for implant. Time-to-first device-related adverse event was shorter in patients with CPs. Regression analysis revealed only increased age (p = 0.03), increase in baseline creatinine (p = 0.002), cardiopulmonary bypass time (p = 0.03), and decreased body mass index (p = 0.03) were predictors of mortality, whereas only age (p = 0.006) and prior sternotomy (p = 0.02) were related to adverse device-related events. Performing CPs leads to comparable survival and device-related outcomes after implant. The decision to perform CPs should be balanced with age, preoperative renal dysfunction, and projected complexity of surgery.
Driveline Infection Risk with Utilization of a Temporary External Anchoring Suture After Implantation of a Left Ventricular Assist Device
Fudim, Marat , Brown, Christopher L. , Djunaidi, M., Danter, Matthew , Stulak, John M., Haglund, Nicholas, Maltais, Simon, Davis, Mary Elizabeth , Harrell, Frank E.

Mayo Clinic

ASAIO Journal | January 24, 2016 | Volume: 62 | Issue: 3 | Pages: 291-296

10.1097/mat.0000000000000346 | PMID 26809083 Get It

Driveline infections (DLI) are a cause of morbidity after continuous-flow left ventricular assist device (CF-LVAD) implantation. Because driveline trauma contributes to DLI, we assessed whether intraoperative placement of a temporary external anchoring suture (EAS) influenced DLI rate. We analyzed 161 consecutive patients with CF-LVAD (HMII 82; HW 79) implantation. Two groups were defined: placement of EAS (n = 85) or No EAS (n = 76). For NO EAS patients, the driveline was permanently anchored internally to the rectus fascia. Cox proportional analysis was performed to assess the effect of EAS on time to first confirmed DLI. Baseline characteristics were comparable between groups (all p = 0.3). Mean follow-up time was 0.93 years. A total of 18 (11.1%) patients developed confirmed culture positive DLI, with “first infection” rate of 0.13 events/year. Mean time to confirmed DLI was 0.69 years. Driveline infection was less likely (hazard ratio [HR] = 0.28, 0.95 confidence interval [CI] = 0.06–1.25, p = 0.056) to occur in NO EAS (2/18) then in EAS (16/18). Confirmed DLI was comparable between device types (p = 0.3). Multivariable regression adjusted for age, BMI, blood product use, device type, and diabetes showed equivocal effect of EAS (HR = 0.33, 0.95 CI = 0.07–1.54, p = 0.12). Patients with a temporary EAS may have an increased risk of confirmed DLI after device implantation.