Citations

Clear

77 citation(s) found for "Bilgin, C".

Comparative analysis of single plane and biplane angiography systems for mechanical thrombectomy for acute ischemic stroke: a systematic review and meta-analysis
Orscelik, Atakan , Bilgin, Cem , Cortese, Jonathan , Cayme, Joshua J , Şenol, Yiğit Can , Musmar, Basel , Ghozy, Sherief , Bayraktar, Esref Alperen , Beizavi, Zahra , Brinjikji, Waleed , Kallmes, David F. , Senol, Yigit Can , Musmar, Basel , Ghozy, Sherief , Bayraktar, Esref Alperen , Brinjikji, Waleed , Orscelik, Atakan , Cortese, Jonathan , Zandpazandi, Sara

Mayo Clinic

Journal of NeuroInterventional Surgery | October 22, 2024 | Volume: 17 | Issue: 6 | Pages: 567-573

10.1136/jnis-2024-022381 | PMID 39438134 Get It

Background The choice of angiography system could influence the outcomes of mechanical thrombectomy (MT) in the treatment of acute ischemic stroke (AIS), but its impact is not yet well understood. This study aims to compare the clinical and technical outcomes of MT performed with single plane versus biplane angiography systems. Method We conducted a systematic review and meta-analysis, following PRISMA guidelines, by searching PubMed, Embase, Web of Science, and Scopus to include studies on patients with AIS who underwent MT with either single plane or biplane angiography up to May 4, 2024. The primary outcome was a favorable outcome defined as a modified Rankin Scale (mRS) score of 0–2 at 90 days after the procedure. Data were analyzed using a random-effects model and heterogeneity was assessed using the I2 test and Q statistics. Results Five studies with a total of 1562 patients were analyzed. Of these, 68.4% were treated with biplane systems and 31.6% with single plane systems. Single plane angiography was associated with a significantly higher rate of favorable outcomes (OR 1.43; 95% CI 1.13 to 1.80; P<0.01). There were no significant differences in successful recanalization, periprocedural complications, procedure time, total fluoroscopy time, or contrast volume between the two systems. Conclusion While single plane angiography systems may offer slightly better outcomes in MT for AIS, both systems appear equally effective in most clinical and technical perspectives, suggesting that system selection may be more dependent on availability and procedural requirements rather than inherent superiority. Our findings may encourage clinicians to use single-plane angiography in settings where the biplane angiography suite availability is limited, but it should be noted that this observation may have been influenced by selection bias, particularly since the larger studies included in our meta-analysis did not observe this effect in adjusted analyses for potential confounder factors.
Effect of the Effective Metal Surface Area of Two Different Flow Diverter Stents on the Stagnation Region Formation Inside the Aneurysm Sac
Gunaydin, Muhammed Talha, Güçlü, Görkem , Orscelik, Atakan , Bilgin, Cem , Hakyemez, Bahattin , Orscelik, Atakan , Olcay, Ali Bahadır , Bilgin, Cem

Mayo Clinic

Asian Journal of Neurosurgery | October 21, 2024 | Volume: 20 | Issue: 01 | Pages: 061-068

10.1055/s-0044-1791842 | PMID 40041585 Get It

Abstract Objective Flow diversion (FD) is a relatively new technique for treating large, wide-necked, or fusiform aneurysms. Although FD is a more preferred option than coiling or clipping techniques in neurosurgery and neuroradiology clinics, the blood flow mechanism inside the aneurysm sac is not fully understood after the treatment. Besides, effective metal surface area (EMSA), a property of an FD related to porosity, shows variation at the patient's aneurysm neck by providing more or less blood flow inside an aneurysm sac than planned, causing nonstagnant or stagnant fluid region formation in the sac, respectively. Thus, the change in FD's EMSA can significantly affect the treatment's effectiveness, making even operation unsuccessful when variation in FD's EMSA at the aneurysm neck is overlooked. Materials and Methods In this study, a large aneurysm of a 52-year-old female patient was numerically investigated by virtually placing two commercially available FDs with different EMSA values one by one into the aneurysm-carrying artery. Results While FD stents at the aneurysm site substantially reduced the blood flow into the aneurysm, an FD with a 15.6% EMSA caused blood to flow in the aneurysm sac to have six times more kinetic energy than that of FD with a 29.5% EMSA. Conclusion Although FD's EMSA value demonstrated nearly up to 20% reduction at the patient's aneurysm neck based on a product catalog value, numerical model results revealed that the stagnated region's formation inside the aneurysm sac could be determined within a 9% difference based on digital subtraction angiography reformat image.
Optimizing the hemodynamics of hand injections in neuroangiography
Bayraktar, Esref Alperen , Bilgin, Cem , Ueki, Yasuhito , Kadirvel, Ramanathan , Brinjikji, Waleed , Cloft, Harry J. , Kallmes, David F. , Bilgin, Cem , Kadirvel, Ram , Kallmes, David F , Bayraktar, Esref Alperen , Li, Jiahui , Cortese, Jonathan

Mayo Clinic

Interventional Neuroradiology | September 23, 2024 | Volume: 30 | Issue: 6 | Pages: 833-838

10.1177/15910199241285944 | PMID 39311020 Get It

Purpose Optimizing the preparation of a 10 ml syringe for manual injection of contrast media can help operators obtain easier and faster injections. This study aims to compare the flow rates of different contrast media injection methods. Methods Different contrast media solutions were compared: 100% contrast (10 ml contrast), mixed contrast solution (8:2 contrast/saline), and layered contrast below saline (“Parfait”) in different volumes. Contrast media were injected at room temperature (20°C) and after heating (37°C). Four operators injected 10 ml syringes filled with different mediums through 5-French angiographic catheters. The average flow rate was used to compare different contrast injection mediums. The Kruskal-Wallis test with post-hoc pairwise comparisons using Bonferroni correction or Mann-Whitney U-tests were employed depending on the type of comparison. Results Compared to the 100% contrast solution, every Parfait media and mixed contrast solution demonstrated significantly higher flow rates (p < 0.001). The 5 ml saline Parfait had the highest flow rate among the Parfait solutions. The 5 ml saline Parfait and the mixed solution had comparable flow rates (p = 0.237). Higher flow rates were observed upon heating both 100% contrast (p < 0.001) and mixed contrast solutions (p < 0.001) in comparison to their flow rates at room temperature. Conclusion This study demonstrates the capability of the Parfait and mixed contrast injections to achieve higher flow rates than the 100% contrast solutions. Heating the contrast media to 37°C also proves to be a viable strategy for further enhancing the flow rates for 100% and mixed contrast solutions.
E-164 Safety profile of surgical embolectomy in acute ischemic stroke patients: a systematic review and meta-analysis
Pakkam, Madona , Bilgin, Cem , Kadirvel, R, Kallmes, D, Orscelik, Atakan , Musmar, Basel , Senol, Y, Ghozy, Sherief , Kadirvel, Ramanathan , Kallmes, David F.

Mayo Clinic

SNIS 21st annual meeting electronic poster abstracts | July 22, 2024 | Volume: No volume available | Issue: No issue available | Pages: A183.2-A184

10.1136/jnis-2024-snis.269 Get It

Pipeline versus non-pipeline flow diverter treatment for M1 aneurysms: A systematic review and meta-analysis
Şenol, Yiğit Can , Orscelik, Atakan , Bilgin, Cem , Kallmes, David F. , Kadirvel, Ramanathan , Arul, Santhosh , Orscelik, Atakan , Senol, Yigit Can , Kobeissi, Hassan , Ghozy, Sherief

Mayo Clinic

The Neuroradiology Journal | July 21, 2024 | Volume: 38 | Issue: 2 | Pages: 133-141

10.1177/19714009241260805 | PMID 39033417 Get It

Background The flow diversion treatment of aneurysms located distal to the Circle of Willis has recently increased in frequency. We conducted a systematic review and meta-analysis of the clinical and radiological outcomes of flow diverter (FD) embolization in treating M1 aneurysms. Methods PubMed, Web of Science, Ovid Medline, Ovid Embase, and Scopus were searched up to May 2024 using the Nested Knowledge platform. We included studies assessing the long-term clinical and radiological outcomes for M1 aneurysms. Results of FDs classified as Pipeline Embolization Devices (PED) versus other types of FDs. Angiographic occlusion rates, ischemic and hemorrhagic complications, and favorable clinic outcomes were included. All data were analyzed using R software version 4.2.2. Results Thirteen studies with 112 total patients (58 patients for PED and 54 patients for other FD devices) were included in our meta-analysis. The overall adequate (complete + near-complete) occlusion rates were 85.1%. The complete occlusion rate was higher with PED than with other FD devices (72.9% PED and 41.6% for non-PED FDs, respectively, p -value <.01). The ischemic complications were 9.9% and 9.0% for the PED and non-PED groups, respectively ( p -value = .89). The overall modified Rankin Scale 0–2 was 100% for the non-PED and 97.1% for the PED group ( p -value = .51). In-stent stenosis rate was 7.5% for PED devices compared to 2.6% in the non-PED group ( p -value = .35). Conclusions This relatively small meta-analysis showed high rates of adequate and complete occlusion in FD treatment of M1 segment aneurysms, with favorable safety profiles. PEDs were associated with higher rates of complete aneurysm occlusion compared to other types of FDs.
In vitro evaluation of flow diverter performance using a human fibrinogen–based flow model
Bilgin, Cem , Kallmes, David F. , Kadirvel, Ramanathan , Bayraktar, Esref Alperen , Oliver, Alexander A , Li, Jiahui , Cebral, Juan R.

Mayo Clinic

Journal of Neurosurgery | July 12, 2024 | Volume: 142 | Issue: 1 | Pages: 154-161

10.3171/2024.4.jns232567 | PMID 38996402 Get It

OBJECTIVE Fibrin deposition represents a key step in aneurysm occlusion, promoting endothelization of implants and connective tissue organization as part of the aneurysm-healing mechanism. In this study, the authors introduce a novel in vitro testing platform for flow diverters based on human fibrinogen. METHODS A flow diverter was deployed in 4 different glass models. The glass models had the same internal parent artery (4 mm) and aneurysm (8 mm) diameters with varying parent artery angulations (paraophthalmic, sidewall, bifurcation, and slightly curved models). The neck size and area were 4 mm and 25 mm 2 , respectively. Human fibrinogen (330 mg/dl) was circulated within the glass models at varying flow rates (0, 3, 4, and 5 ml/sec) with or without heparin, calcium chloride, and thrombin for as long as 6 hours or until complete fibrin coverage of the flow diverter’s neck was achieved. Aneurysm neck coverage was defined as macroscopic fibrin deposition occluding the flow diverters’ pores. Flow characteristics after flow diverter deployment were assessed with computational fluid dynamics analysis. The effects of flow rates, heparin, calcium chloride, and thrombin on fibrin deposition rates were tested using 1-way ANOVA and the Tukey test. RESULTS A total of 84 replicates were performed. Human fibrin did not accumulate on the flow diverter stents under static conditions. The fibrin deposition rate on the aneurysm neck was significantly greater with the 5 ml/sec flow rate as compared to 3 ml/sec for all models. The paraophthalmic model had the highest inflow velocity of 48.7 cm/sec. The bifurcation model had the highest maximum shear stress (SS) and maximum normalized shear stress values at the device cells at 843.3 dyne/cm 2 and 35.1 SS/SS inflow , respectively. The fibrin deposition rates of the paraophthalmic and bifurcation models were significantly higher than those of sidewall and slightly curved models for all additive or flow rate comparisons (p = 0.001 for all comparisons). The incorporation of thrombin significantly increased the fibrin deposition rates across all models (p = 0.001 for all models). CONCLUSIONS Rates of fibrin deposition varied widely across different configurations and additive conditions in this novel in vitro model system. Fibrin accumulation started at the aneurysm inflow zone where flow velocity and shear stress were the highest. The primary factors influencing fibrin deposition included flow velocities, shear stress, and the addition of thrombin at a physiological concentration. Further research is needed to test the clinical utility of fibrinogen-based models for patient-specific aneurysms.
How Flow Diverter Selection Can Affect the Flow Changes within a Jailed Ophthalmic Artery: A Computational Fluid Dynamics Study
Ünsal, Can, Güçlü, Görkem , Hassankhani, Amir , Bilgin, Cem , Hakyemez, Bahattin , Olcay, Ali Bahadır , Bilgin, Cem

Mayo Clinic

Asian Journal of Neurosurgery | June 27, 2024 | Volume: 19 | Issue: 03 | Pages: 426-434

10.1055/s-0044-1787868 | PMID 39205892 Get It

Abstract Introduction Flow diverter (FD) stents are widely used to treat giant aneurysms by reducing blood flow into the aneurysm sac. However, choosing the optimal FD for a patient can be challenging when a nearby artery, such as the ophthalmic artery (OA), is jailed by the FD placement. This study compares the impact of two FD stents with different effective metal surface area (EMSA) values on OA occlusion. Materials and Methods A numerical model of a 59-year-old female patient with a giant aneurysm in the left internal carotid artery and a jailed OA was created based on clinical data. Two FD stents, FRED4017 and FRED4518, with different EMSA values at the aneurysm neck and OA inlet, were virtually deployed in the model. Blood flow and occlusion amount in the OA were simulated and compared between the two FD stents. Results FRED4017 had higher EMSA values than FRED4518 at the aneurysm neck (35% vs. 24.6%) and lower EMSA values at the OA inlet (15% vs. 21.2%). FRED4017 caused more occlusion in the OA than FRED4518 (40% vs. 28%), indicating a higher risk of ocular ischemic syndrome. Conclusion The EMSA value of FD stents affects the blood flow and occlusion amount in the jailed OA. Therefore, selecting an FD stent with a low EMSA value at the OA inlet may be beneficial for patients with a nearby jailed artery at the aneurysm neck.
Comparative meta-analysis of endovascular strategies for intracranial dissecting aneurysms: Flow diverters versus stents with or without coiling
Amoukhteh, Melika , Hassankhani, Amir , Jannatdoust, Payam , Valizadeh, Parya , Ghozy, Sherief , Bilgin, Cem , Kallmes, David F. , Ghozy, Sherief , Bilgin, Cem

Mayo Clinic

Interventional Neuroradiology | June 14, 2024 | Volume: 32 | Issue: 4 | Pages: 1669-1679

10.1177/15910199241262070 | PMID 38873695 Get It

Background Intracranial dissecting aneurysms present a challenging subset linked to considerable morbidity and mortality, necessitating effective therapeutic strategies to prevent complications. Traditional treatments face technical limitations, while emerging endovascular modalities like stent-assisted coiling, multiple stenting, and flow-diverting devices (FDDs) offer promise in reducing periprocedural risks and enhancing patient outcomes. The aim of this study is to compare the safety and efficacy outcomes of endovascular treatment for intracranial dissecting aneurysms using FDDs versus stents (with or without coiling). Methods A systematic review and meta-analysis were conducted following established guidelines. The search included PubMed, Scopus, Web of Science, and Embase databases up to July 30, 2023. Eligible studies reporting outcomes of interest in both FDD and stent-treated groups were included, and the data was extracted and analyzed using STATA software. Results Six studies were analyzed, involving 131 patients in the FDD group and 199 patients in the stent group. The pooled rates for favorable functional outcomes (86.8% vs. 86%), mortality (3.9% vs. 6%), adequate occlusion (79.7% vs. 86.3%), aneurysm recurrence (1.3% vs. 13.3%), in-stent stenosis/thrombosis (7% vs. 6.9%), ischemic events/infarctions (6.7% vs. 7.8%), retreatment (7% vs. 8.6%), and technical success (100% vs. 98.7%) were comparable in individuals treated with FDDs and stents (p > 0.05 in all cases). Additionally, complete occlusion rates were not significantly different between FDD (62.7%) and stent-treated patients (75.2%) (p = 0.06). However, after excluding one study in a leave-one-out analysis of the random effects meta-analysis, a significant difference in the pooled rates of this outcome was observed between the FDD (59.2%) and stent (75.2%) groups (p = 0.034). Conclusion FDDs present a promising approach for the treatment of intracranial dissecting aneurysms, yielding outcomes that are roughly comparable to stent-based methods. However, the absence of randomized trials and data limitations highlight the need for further research to enhance treatment strategies.
Creating elastase aneurysms in rabbits: a video primer
Cortese, Jonathan , Bayraktar, Esref Alperen , Oliver, Alexander A , Bilgin, Cem , Ding, Yong-Hong, Ueki, Yasuhito , Lortscher, Sarah, Brinjikji, Waleed , Kadirvel, Ramanathan , Kallmes, David F. , Cortese, Jonathan , Bayraktar, Esref Alperen , Oliver, Alexander A , Ding, Yonghong

Mayo Clinic

Journal of NeuroInterventional Surgery | June 11, 2024 | Volume: 17 | Issue: 10 | Pages: 1133-1133

10.1136/jnis-2024-021912 | PMID 38862208 Get It

The New Zealand rabbit elastase-induced arterial aneurysm of the right common carotid artery remains a widely used model for assessing the effectiveness and safety of new neuroendovascular devices.1 This model offers a simple and reliable platform for pre-clinical in vivo investigations, crucial for comprehending the biological processes underlying aneurysm healing after endovascular treatment.2 Notably, the induced aneurysm exhibits morphological, hemodynamic, and histological characteristics similar to human intracranial aneurysms. The creation of the aneurysm is performed using open and endovascular techniques. Each step of the procedure requires a meticulous and controlled gesture to ensure reproducibility of the aneurysm and minimize animal misuse. In video 1 we present a step-by-step procedural guide for aneurysm creation and follow-up. We hope this resource will help in promoting this model and provide useful guidance for researchers in the field. Video 1 Surgical procedure of creating elastase-induced aneurysms in rabbits.
How the elastase-induced rabbit aneurysm heals following flow diverter treatment: a histopathological study
Bilgin, Cem , Kallmes, David F. , Kadirvel, Ramanathan , Dai, Daying , Ding, Yonghong , Ghozy, Sherief , Mereuta, Oana Madalina

Mayo Clinic

Journal of Neurosurgery | May 17, 2024 | Volume: 141 | Issue: 5 | Pages: 1262-1269

10.3171/2024.2.jns232262 | PMID 38759235 Get It

OBJECTIVE Fibrin deposition is integral to thrombus formation and wound healing. The role of fibrin deposition and subsequent metabolism following flow diversion for aneurysm treatment remains poorly characterized. This study aimed to evaluate the role of fibrin in early thrombus organization after flow diverter treatment. METHODS Thirty-five elastase-induced aneurysms were induced in New Zealand white rabbits and subjected to endoluminal flow diversion treatment. The device-bearing arteries were harvested at 1, 3, and 6 months postimplantation and processed for histopathological examination, including a modified picro-Mallory stain (Carstairs method) to visualize fibrin and platelets, immunohistochemical targeting of smooth muscle actin (SMA), and H&E staining for conventional morphological evaluation. Quantitative analysis of tissue components was carried out using the Orbit Image Analysis software. The samples were also assessed qualitatively to investigate the morphology and location of fibrin and other thrombus components within the intra-aneurysmal thrombi. Statistical analyses were conducted using R software version 4.3.1. RESULTS Fibrin constituted 27.9% of the thrombus tissue within the aneurysm sac for aneurysms harvested at 1 month, and this rate was significantly lower in the 3-month group (10.2%, p = 0.018). The proportion of blood cells within the sac was also notably higher in the 1-month group compared with other time points. The primary tissue filling the dome at 1 month (14/15, 93%) was an unorganized thrombus primarily composed of fibrin, platelets, and red blood cells. Conversely, aneurysms harvested at 1 month had the lowest collagen level (25.6%). However, collagen became the dominant tissue component within the aneurysm sac, accounting for 71.8% of tissue in the 3-month group (p = 0.007). There were no differences observed among the examined components between the 3-month and 6-month groups. On qualitative analysis, collagen-producing SMA-positive myofibroblasts were located near or in between fibrin molecules. Healed aneurysms exhibited myofibroblasts, collagen, and a well-organized fibrin network on the aneurysm neck. In contrast, unhealed aneurysms displayed a poorly organized fibrin network with scattered myofibroblasts at the neck area. CONCLUSIONS These findings indicate that fibrin plays a foundational role in the gradual occlusion of aneurysms after flow diverter treatment. Endovascular approaches that enhance fibrin accumulation could potentially improve aneurysm occlusion rates. Further research is needed to establish the precise role of fibrin in aneurysm occlusion.