Citations

Clear

6730 citation(s) found for "Li, Mark".

Intravenous Tranexamic Acid Safely and Effectively Reduces Transfusion Rates in Revision Total Knee Arthroplasties
Hines, Jeremy T. , Petis, Stephen M. , Amundson, Adam W. , Pagnano, Mark W. , Sierra, Rafael J. , Abdel, Matthew P. , Petis, Stephen , Abdel, Matthew P , Sierra, Rafael J

Mayo Clinic

Journal of Bone and Joint Surgery | January 24, 2020 | Volume: 102 | Issue: 5 | Pages: 381-387

10.2106/jbjs.19.00857 | PMID 31977819 Get It

Background: The efficacy and safety of tranexamic acid (TXA) in primary total knee arthroplasty (TKA) have been well established. However, there have been limited data for revision TKAs. The primary aim was to assess the impact of intravenous TXA on transfusion rates and symptomatic venous thromboembolic events (VTEs) in a large revision TKA cohort with or without intravenous TXA utilization. Methods: A retrospective review of revision TKAs performed from 2005 to 2014 was performed, identifying 2,951 procedures (2,219 patients), in which TXA was utilized in 1,144 procedures (39%). The mean age was 65 years with 52% female patients in the TXA revision group and 67 years with 52% female patients in the non-TXA revision group. Transfusion rates and symptomatic VTEs were the primary outcomes assessed. Comparisons were performed between cohorts, utilizing a unique propensity model to mitigate bias, on the basis of TXA use and subsequently for aseptic or septic revision etiology. Results: Significant reductions in transfusion rates with use of TXA were identified in revision TKAs overall (13% compared with 39%; p < 0.001 [adjusted relative risk, 1.7]), including revisions for both aseptic etiology (6% with TXA compared with 28% without TXA; p < 0.001) and septic etiology (31% with TXA compared with 54% without TXA; p < 0.001). The risk of a postoperative symptomatic VTE was not significantly different (adjusted p = 0.63) with use of TXA at 11 events (1.0%) compared with 24 events (1.3%) in the non-TXA group). Conclusions: Intravenous TXA significantly reduced transfusion rates in revision TKAs by approximately twofold, including cohorts revised for aseptic and septic etiologies. There was a very low rate of VTEs (1.2%) with no significant difference in the number of VTEs between groups after adjusting risk utilizing propensity modeling. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Serum Transferrin Is an Independent Predictor of Mortality in Severe Alcoholic Hepatitis
Atkinson, Stephen R. , Hamesch, Karim , Spivak, Igor , Güldiken, Nurdan , Argemí, Josepmaria , Zoller, Heinz , Cao, Sheng , Mathurin, Philippe , Shah, Vijay H. , Trautwein, Christian, Thursz, Mark , Cabezas, Joaquín , Theurl, Igor , Bataller, Ramon A , Strnad, Pavel

Mayo Clinic

American Journal of Gastroenterology | January 24, 2020 | Volume: 115 | Issue: 3 | Pages: 398-405

10.14309/ajg.0000000000000492 | PMID 31985531 Get It

OBJECTIVES: Severe alcoholic hepatitis (sAH) confers substantial mortality, but the disease course is difficult to predict. As iron parameters are attractive outcome predictors in other liver diseases, we tested their prognostic ability in sAH. METHODS: Serum ferritin, transferrin, iron, transferrin saturation, nontransferrin-bound iron, soluble transferrin receptor, and hepcidin were measured in 828 patients with sAH recruited prospectively through the STOPAH trial. The cohort was randomly divided into exploratory (n = 200) and validation sets (n = 628). RESULTS: Patients with sAH had diminished serum transferrin but increased transferrin saturation. Among iron parameters, baseline transferrin was the best predictor of 28-day (area under the receiver operated characteristic 0.72 [95% confidence interval 0.67–0.78]) and 90-day survival (area under the receiver operated characteristic 0.65 [0.61–0.70]). Transferrin's predictive ability was comparable with the composite scores, namely model of end-stage liver disease, Glasgow alcoholic hepatitis score, and discriminant function, and was independently associated with survival in multivariable analysis. These results were confirmed in a validation cohort. Transferrin did not correlate with markers of liver synthesis nor with non–transferrin-bound iron or soluble transferrin receptor (as markers of excess unbound iron and functional iron deficiency, respectively). DISCUSSION: In patients with sAH, serum transferrin predicts mortality with a performance comparable with commonly used composite scoring systems. Hence, this routinely available parameter might be a useful marker alone or as a component of prognostic models.
In Response
Rice, Mark J., Brull, Sorin J. , Brull, Sorin J , Zdravković, Marko

Mayo Clinic

Anesthesia & Analgesia | January 24, 2020 | Volume: 132 | Issue: 2 | Pages: e24-e25

10.1213/ane.0000000000004658 | PMID 31977361 Get It

Liquid Chromatographic–Tandem Mass Spectrometric Method for the Determination of 5-Hydroxyindole-3-acetic Acid in Urine
Kroll, Charles, Magera, Mark J , Helgeson, Janice K, Matern, Dietrich , Rinaldo, Piero

Mayo Clinic

Clinical Chemistry | January 24, 2020 | Volume: 48 | Issue: 11 | Pages: 2049-2051

10.1093/clinchem/48.11.2049 Get It

Kidney Structural Features from Living Donors Predict Graft Failure in the Recipient
Issa, Naim , Lopez, Camden , Đenić, Aleksandar , Taler, Sandra J. , Larson, Joseph J. , Kremers, Walter K. , Ricaurte, Luisa , Merzkani, Massini , Alexander, Mariam P., Chakkera, Harini A. , Stegall, Mark D. , Augustine, Joshua J. , Alexander, Mariam Priya, Rule, Andrew D , Stegall, Mark D , Denic, Aleksandar , Lopez, Camden L , Chakkera, Harini A , Kremers, Walter K , Augustine, Joshua , Rule, Andrew D.

Mayo Clinic

Journal of the American Society of Nephrology | January 23, 2020 | Volume: 31 | Issue: 2 | Pages: 415-423

10.1681/asn.2019090964 | PMID 31974271 Get It

Significance Statement The quality of a kidney obtained from a living donor is often inferred from the donor’s age, risk factors, and kidney function. Little is known about the influence of a donated kidney’s structural features on the risk of death-censored graft failure in the recipient. In an analysis of 2293 kidney donor-recipient pairs, the authors identified subclinical nephrosclerosis, larger nephron size (but not nephron number), and smaller medullary volume as structural predictors of death-censored graft failure that were independent of both donor and recipient clinical characteristics. These findings provide important insights into the factors that define the “intrinsic quality” of the living kidney donor graft at the time of donation, and support use of intraoperative biopsies to identify donor kidneys that are at higher risk for failure. Background Nephrosclerosis, nephron size, and nephron number vary among kidneys transplanted from living donors. However, whether these structural features predict kidney transplant recipient outcomes is unclear. Methods Our study used computed tomography (CT) and implantation biopsy to investigate donated kidney features as predictors of death-censored graft failure at three transplant centers participating in the Aging Kidney Anatomy study. We used global glomerulosclerosis, interstitial fibrosis/tubular atrophy, artery luminal stenosis, and arteriolar hyalinosis to measure nephrosclerosis; mean glomerular volume, cortex volume per glomerulus, and mean cross-sectional tubular area to measure nephron size; and calculations from CT cortical volume and glomerular density on biopsy to assess nephron number. We also determined the death-censored risk of graft failure with each structural feature after adjusting for the predictive clinical characteristics of donor and recipient. Results The analysis involved 2293 donor-recipient pairs. Mean recipient follow-up was 6.3 years, during which 287 death-censored graft failures and 424 deaths occurred. Factors that predicted death-censored graft failure independent of both donor and recipient clinical characteristics included interstitial fibrosis/tubular atrophy, larger cortical nephron size (but not nephron number), and smaller medullary volume. In a subset with 12 biopsy section slides, arteriolar hyalinosis also predicted death-censored graft failure. Conclusions Subclinical nephrosclerosis, larger cortical nephron size, and smaller medullary volume in healthy donors modestly predict death-censored graft failure in the recipient, independent of donor or recipient clinical characteristics. These findings provide insights into a graft’s “intrinsic quality” at the time of donation, and further support the use of intraoperative biopsies to identify kidney grafts that are at higher risk for failure.
An Innovative and Accessible Biofeedback Intervention for Improving Self-Regulatory Skills in Pediatric Chronic Pain: A Pilot Study
Fahrenkamp, Amy J., Sim, Leslie , Roers, Lisbeth, Canny, Mark, Harrison, Tracy E. , Harbeck‐Weber, Cynthia , Fahrenkamp, Amy, Harrison, Tracy, Harbeck‐Weber, Cynthia

Mayo Clinic

The Journal of Alternative and Complementary Medicine | January 23, 2020 | Volume: 26 | Issue: 3 | Pages: 212-218

10.1089/acm.2019.0297 | PMID 31971811 Get It

Rapid Determination of Transferrin Isoforms by Immunoaffinity Liquid Chromatography and Electrospray Mass Spectrometry
Lacey, Jean M., Bergen, H. Robert, Magera, Mark J , Naylor, Stephen , O’Brien, John F.

Mayo Clinic

Clinical Chemistry | January 23, 2020 | Volume: 47 | Issue: 3 | Pages: 513-518

10.1093/clinchem/47.3.513 Get It

AbstractBackground: Congenital disorders of glycosylation (CDG) are autosomal recessive disorders that produce increased serum carbohydrate-deficient transferrin (CDT) isoforms. Methods to resolve CDT from fully glycosylated transferrin (Trf) have been based on a neutral shift in the isoelectric focusing (IEF) pattern or on a reduction in the negative charge, allowing resolution by anion-exchange chromatography. Our purpose was to develop a method of resolution and relative quantification of Trf isoforms using online immunoaffinity liquid chromatography–mass spectrometry (LC-MS).Methods: Serum (25 μL) was diluted with 100 μL of water before application to an immunoaffinity column that sequestered Trf isoforms. Trf isoforms were eluted from the immunoaffinity column, concentrated on a C4 column, eluted from the C4 column, and introduced into the mass spectrometer. Analysis of the Trf isoforms was entirely automated and completed in &lt;10 min per sample.Results: The LC-MS method demonstrated that the major abnormal Trf isoforms in CDG lack one complete oligosaccharide structure (mono-oligosaccharide) or both oligosaccharide structures (a-oligosaccharide), but not the sialic acids, as presumed on the basis of IEF methods. Calculation of relative ratios among three possible species (mono-/di-oligosaccharide and a-/di-oligosaccharide) is reproducible [mean intra- and interassay CVs were 9.3% (n = 10) and 10% (n = 5), respectively]. A reference range for patients &lt;18 years was determined by analysis of 209 samples (for mono-/di-oligosaccharide, the median was 0.041 and the range was 0.018–0.083; for a-/di-oligosaccharide, the median was 0.007 and the range was 0.002–0.036). Comparison of data obtained with an affinity chromatography-IEF method and the LC-MS method demonstrated equivalence in the interpreted results (n = 170).Conclusions: Advantages of the LC-MS method include improved sensitivity, minimal sample preparation, and an analysis time of &lt;10 min. The method was automated, which allowed high throughput, with &gt;100 samples analyzed in a single day. Moreover, the nature of the oligosaccharide defect in CDG is accurately reflected by mass resolution, and subtle oligosaccharide truncations may also be detected by this method.
Methylmalonic Acid Measured in Plasma and Urine by Stable-Isotope Dilution and Electrospray Tandem Mass Spectrometry
Magera, Mark J , Helgeson, Janice K, Matern, Dietrich , Rinaldo, Piero

Mayo Clinic

Clinical Chemistry | January 23, 2020 | Volume: 46 | Issue: 11 | Pages: 1804-1810

10.1093/clinchem/46.11.1804 Get It

Abstract Background: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionization is robust and allows accurate measurement of both low- and high-molecular weight components of complex mixtures. We developed a LC-MS/MS method for the analysis of methylmalonic acid (MMA), a biochemical marker for inherited disorders of propionate metabolism and acquired vitamin B12 deficiency. Methods: We added 1 nmol of the internal standard MMA-d3 to 500 μL of plasma or 100 μL of urine before solid-phase extraction. After elution with 18 mol/L formic acid, the eluate was evaporated, and butyl ester derivatives were prepared with 3 mol/L HCl in n-butanol at 65 °C for 15 min. For separation, we used a Supelcosil LC-18, 33 × 4.6 mm column with 60:40 (by volume) acetonitrile:aqueous formic acid (1 g/L) as mobile phase. The transitions m/z 231 to m/z 119 and m/z 234 to m/z 122 were used in the selected reaction monitoring mode for MMA and MMA-d3, respectively. The retention time of MMA was 2.2 min in a 3.0-min analysis, without interference of a physiologically more abundant isomer, succinic acid. Results: Daily calibrations between 0.25 and 8.33 nmol in 0.5 mL exhibited consistent linearity and reproducibility. At a plasma concentration of 0.12 μmol/L, the signal-to-noise ratio for MMA was 40:1. The regression equation for our previous gas chromatography-mass spectrometry (GC-MS) method (y) and the LC-MS/MS method (x) was: y = 1.030x − 0.032 (Sy|x = 1.03 μmol/L; n = 106; r = 0.994). Inter- and intraassay CVs were 3.8–8.5% and 1.3–3.4%, respectively, at mean concentrations of 0.13, 0.25, 0.60, and 2.02 μmol/L. Mean recoveries of MMA added to plasma were 96.9% (0.25 μmol/L), 96.0% (0.60 μmol/L), and 94.8% (2.02 μmol/L). One MS/MS system used only overnight (7.5 h) replaced two GC-MS systems (30 instrument-hours/day) to run 100–150 samples per day, with reductions of total cost (supplies plus equipment), personnel, and instrument time of 59%, 14%, and 75%, respectively. Conclusions: This method is well suited for large-scale MMA testing (≥100 samples per day) where a shorter analytical time is highly desirable. Reagents are less expensive than the anion-exchange/cyclohexanol-HCl method, and sample preparation of batches up to 100 specimens is completed in less than 8 h and is automated.
Quantitative Measurement of Porphobilinogen in Urine by Stable-Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry
Ford, Roddey E., Magera, Mark J , Kloke, Karen M., Chezick, Paul A., Fauq, Abdul H. , McConnell, Joseph P.

Mayo Clinic

Clinical Chemistry | January 23, 2020 | Volume: 47 | Issue: 9 | Pages: 1627-1632

10.1093/clinchem/47.9.1627 Get It

AbstractBackground: Measurement of porphobilinogen (PBG) is useful in the diagnosis of the acute neurologic porphyrias. Currently used colorimetric assays lack analytical and clinical sensitivity and specificity.Methods: We developed a liquid chromatography-electrospray tandem mass spectrometry (LC-MS/MS) method for the measurement of PBG in 1 mL of urine, using 5-(aminoethyl)-4-(carboxymethyl) 1H-2,4-[13C]pyrolle-3-propanoic acid ([2,4-13C]PBG; 2.75 μg) as internal standard. After solid-phase extraction, LC-MS/MS analysis was performed in the selected-reaction monitoring (SRM) mode. PBG and [2,4-13C]PBG were monitored through their own precursor and product ion settings (m/z 227 to 210 and m/z 229 to 212, respectively). The retention time of PBG and [2,4-13C]PBG was 1.0 min in a 2.3-min analysis.Results: Daily calibrations (n = 6) between 0.1 and 2.0 mg/L were linear and reproducible. Inter- and intraassay CVs were 3.2–3.5% and 2.6–3.1%, respectively, at mean concentrations of 0.24, 1.18, and 2.15 mg/L. The regression equation for the comparison between an anion-exchange column method (y) and the LC-MS/MS method (x) was: y = 0.84x + 0.74 (Sy|x = 5.8 mg/24 h; r = 0.85; n = 100). In 47 volunteers, PBG excretion was 0.02–0.42 mg/24 h, lower than reported reference intervals (up to 2.0 mg/24 h) based on colorimetric methods. In 85 samples with PBG ≤0.5 by LC-MS/MS, 8 (9.4%) had values ≥2.0 mg/24 h by the anion-exchange method (mean ± SD, 4.3 ± 1.8 mg/24 h). In 11 patients with confirmed diagnoses of acute porphyria and increased PBG by LC-MS/MS, 2 had values within the reported reference intervals by a quantitative anion-exchange method.Conclusions: The quantitative LC-MS/MS method for PBG measurement exhibits greater analytical specificity and improved clinical sensitivity and specificity than currently available methods.
Method for the Determination of Total Homocysteine in Plasma and Urine by Stable Isotope Dilution and Electrospray Tandem Mass Spectrometry
Magera, Mark J , Lacey, Jean M., Casetta, Bruno, Rinaldo, Piero

Mayo Clinic

Clinical Chemistry | January 23, 2020 | Volume: 45 | Issue: 9 | Pages: 1517-1522

10.1093/clinchem/45.9.1517 Get It

Abstract Background: Total homocysteine (tHcy) has emerged as an important independent risk factor for cardiovascular disease. Analytical methods are needed to accommodate the high testing volumes for tHcy and provide rapid turnaround. Methods: We developed liquid chromatography electrospray tandem mass spectrometry (LC-MS/MS) method based on the analysis of 100 μL of either plasma or urine with homocystine-d8 (2 nmol) added as internal standard. After sample reduction and deproteinization, the analysis was performed in the multiple reaction monitoring mode in which tHcy and Hcy-d4 were detected through the transition from the precursor to the product ion (m/z 136 to m/z 90 and m/z 140 to m/z 94, respectively). The retention time of tHcy and Hcy-d4 was 1.5 min in a 2.5-min analysis. Results: Daily calibrations between 2.5 and 60 μmol/L exhibited consistent linearity and reproducibility. At a plasma concentration of 0.8 μmol/L, the signal-to-noise ratio for tHcy was 17:1. The regression equation for the comparison between our previous HPLC method (y) and the LC-MS/MS method (x) was y = 1.097x − 1.377 (r = 0.975; Sy|x =1.595 μmol/L; n = 367), and for comparison between a fluorescence polarization immunoassay (Abbott IMx; y) and LC-MS/MS (x) was y = 1.039x + 0.025 (r = 0.969; Sy|x =1.146 μmol/L; n = 367). Inter- and intraassay CVs were 2.9–5.9% and 3.6–5.3%, respectively, at mean concentrations of 3.9, 22.7, and 52.8 μmol/L. Mean recovery of tHcy was 94.2% (20 μmol/L) and 97.8% (50 μmol/L). Conclusions: The sensitivity and specificity of tandem mass spectrometry are well suited to perform high-volume analysis of tHcy. Reagents are inexpensive and sample preparation of a batch of 40 specimens is completed in less than 1 h and is amenable to automation.