Citations

Clear

4564 citation(s) found for "Yu, Virginia".

Echocardiographic Evaluation of Aorta to Right Atrial Fistula Secondary to Ruptured Sinus of Valsalva Aneurysm
Fritz, Ashley Virginia , Boles, Kathryn S., Fritz, Ashley V, Martin, Archer Kilbourne , Boles, Kathryn S.

Mayo Clinic

Annals of Cardiac Anaesthesia | July 25, 2018 | Volume: 21 | Issue: 3 | Pages: 313-314

10.4103/aca.aca_229_17 | PMID 30052225 Get It

We present the case of a 37 year old male who presented with new onset dyspnea, tachycardia, palpitations, and chest tightness. His initial work up demonstrated a dilated pulmonary artery with reflux of contrast dye in to the IVC. Transthoracic echocardiogram identified a “windsock” appearance indicating Sinus of Valsalva aneurysm (SVA) and severe aortic regurgitation. As a result, the patient was taken for emergent surgery where the windsock tissue was surgically repaired with bovine pericardial patch. This case illuminates the uncommon occurrence of SVA and the ability to recognize these findings on multiple imaging modalities including transthoracic, transesophageal two and three dimensional echocardiography as well as direct surgical field visualization.
A Call to Action for Optimizing the Electronic Health Record in the Parenteral Nutrition Workflow
Vanek, Vincent W., Ayers, Phil , Kraft, Michael D. , Bouche, Jean M., Do, Van T., Durham, Charles W., Guenter, Peggi , Hoggle, Lindsey, Kent, Sue, Lin, Emily T., Molinar, L. Steven , Plogsted, Steven W., Poehls, Jessica M., Turner, Peggy, Way, Charles W. Van , Kraft, Michael , Van Way, Charles , Durham, Charles W.

Mayo Clinic

Nutrition in Clinical Practice | July 25, 2018 | Volume: 33 | Issue: 5 | Pages: No page available

10.1002/ncp.10095 | PMID 30043492 Get It

AbstractParenteral nutrition (PN) is a complex therapeutic modality provided to neonates, children, and adults for various indications. Surveys have shown that current electronic health record (EHR) systems are in need of functionality enhancement for safe and optimal delivery of PN. This is a consensus statement from the American Society for Parenteral and Enteral Nutrition, the Academy of Nutrition and Dietetics, and the American Society of Health‐System Pharmacists outlining some of the key challenges to prescribing, order review/verification, compounding, and administration of PN using EHRs today and is a call to action for clinicians and vendors to optimize their EHRs regarding the PN build and workflow.
Multicenter Laboratory Comparison of Iohexol Measurement
Schwartz, George J. , Wang, Hongyue , Erway, Brian, Seegmiller, Jesse C. , Bäck, Sten-Erik, Miller, W. Greg , Eckfeldt, John H., Nordin, Gunnar , Lieske, John C.

Mayo Clinic

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 2 | Issue: 5 | Pages: 711-724

10.1373/jalm.2017.024240 | PMID 31276084 Get It

Abstract Background Iohexol is used for measurement of kidney glomerular filtration rate (GFR). Until recently, there have not been available proficiency standards to assist in calibrating a laboratory's results. In view of a shift in calibration at the University of Rochester Medical Center (URMC) laboratory, serving as Central Biochemistry Laboratory for the CKiD study, we performed a multicentered laboratory comparison. Methods Two batches of 30 fortified sera and patient samples from serum or heparinized plasma were sent for duplicate analysis to URMC, University of Minnesota (UMN), Mayo Clinic, and University of Lund. Five proficiency testing materials from Equalis AB were also provided. Iohexol calibration was performed using dilutions of OmnipaqueTM 300 and concentrations measured by HPLC or LC-MS/MS (Mayo). Results The 2 batches sent to UMN and University of Lund agreed well. URMC calibration was 11%–13% lower, and Mayo was 4%–8% lower for fortified samples. URMC corrected calibration was 3%–8% higher for these samples. When measured values were adjusted for the results of the Equalis samples, all laboratories agreed within 1%–2% on all iohexol concentrations. Conclusions For 12 URMC calibrator lots from November 2006 to March 2016, the factor quantifying the underestimation of measured to true iohexol concentration was 0.89. If each concentration was divided by 0.89, the calculated GFRs would be reduced by 10%–11%. GFR results for CKiD were adjusted for this shift in calibration. Regular examination of iohexol proficiency testing materials, free exchange of samples among laboratories, and standardized dilution of the stock iohexol for calibration would help to bring more universal agreement to this assay.
Standardization of Urine Albumin Measurements: Status and Performance Goals
Miller, W. Greg , Seegmiller, Jesse C. , Narva, Andrew S., Bachmann, Lorin M, Lieske, John C.

Mayo Clinic

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 2 | Issue: 3 | Pages: 423-429

10.1373/jalm.2017.023614 | PMID 33636850 Get It

Abstract Background Urine albumin is a key laboratory test used for classification, assessment of risk, and monitoring treatment of patients with chronic kidney disease. Urine albumin measurement results are not standardized among different measurement procedures. Consequently, clinical guidelines using fixed decision values for urine albumin cannot be applied consistently. Content Isotope dilution mass spectrometry reference measurement procedures and certified reference materials are being developed to enable standardization of immunoassay measurement procedures for urine albumin. A previous report determined calibration bias was the major error source for differences in results among different measurement procedures for urine albumin. Performance goals for between-day precision, ≤6% CV above 15 mg/L, and for specimen-specific effects, ≤6% CV, were established on the basis of the performance capability of current measurement procedures. The biological variation model was used to estimate a total allowable error of ≤24%–30% and from that the goal for bias of ≤7%–13%. Summary A reference system of higher-order certified reference materials and reference measurement procedures is being developed to enable standardization of urine albumin measurement results. Goals have been established for total allowable error, specimen-specific effects, imprecision, and bias to facilitate efforts to standardize urine albumin measurement results.
Executive Summary: American Association of Clinical Chemistry Laboratory Medicine Practice Guideline—Using Clinical Laboratory Tests to Monitor Drug Therapy in Pain Management Patients
Jannetto, Paul J. , Bratanow, Nancy C, Clark, William , Hamill-Ruth, Robin J. , Hammett‐Stabler, Catherine A. , Kassed, Cheryl A., McMillin, Gwendolyn A. , Melanson, Stacy E.F. , Langman, Loralie J., Clark, William A, Huestis, Marilyn Ann

Mayo Clinic

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 2 | Issue: 4 | Pages: 489-526

10.1373/jalm.2017.023341 | PMID 33636890 Get It

Old Remedies to Heal the Liver: Novel Effects of Digoxin in Hepatic Sterile Inflammation
Arab, Juan Pablo , Arab, Juan P, Arab, Juan P , Arrese, Marco

Mayo Clinic

Hepatology | July 23, 2018 | Volume: 69 | Issue: 2 | Pages: 904-906

10.1002/hep.30188 | PMID 30033594 Get It

Managing Recurrent Urinary Tract Infections in Postmenopausal Women
Seaberg, Preston H. , Jadoon-Khamash, Erum, Vegunta, Suneela , Seaberg, Preston

Mayo Clinic

Journal of Women's Health | July 18, 2018 | Volume: 27 | Issue: 7 | Pages: 856-858

10.1089/jwh.2018.7105 | PMID 30020847 Get It

Quantitative Spatial Profiling of PD-1/PD-L1 Interaction and HLA-DR/IDO-1 Predicts Improved Outcomes of Anti–PD-1 Therapies in Metastatic Melanoma
Johnson, Douglas B. , Bordeaux, Jennifer , Kim, Ju Young, Vaupel, Christine, Rimm, David L. , Ho, Thai H. , Joseph, Richard W. , Daud, Adil , Conry, Robert M. , Gaughan, Elizabeth , Hernandez‐Aya, Leonel F. , Funchain, Pauline , Smithy, James W. , Witte, John S. , McKee, Svetlana B., Wrangle, John M., Dabbas, Bashar , Tangri, Shabnam, Lameh, Jelveh, Hall, Jeffrey M., Markowitz, Joseph , Balko, Justin M. , Dakappagari, Naveen, Daud, Adil I , Smithy, James , Ko, Jennifer , Wrangle, John M , Ho, Thai , Funchain, Pauline , Rimm, David , Dimou, Anastasios , Ko, Jennifer S.

Mayo Clinic

Clinical Cancer Research | July 18, 2018 | Volume: 24 | Issue: 21 | Pages: 5250-5260

10.1158/1078-0432.ccr-18-0309 | PMID 30021908 Get It

Abstract Purpose: PD-1/L1 axis–directed therapies produce clinical responses in a subset of patients; therefore, biomarkers of response are needed. We hypothesized that quantifying key immunosuppression mechanisms within the tumor microenvironment by multiparameter algorithms would identify strong predictors of anti–PD-1 response. Experimental Design: Pretreatment tumor biopsies from 166 patients treated with anti–PD-1 across 10 academic cancer centers were fluorescently stained with multiple markers in discovery (n = 24) and validation (n = 142) cohorts. Biomarker-positive cells and their colocalization were spatially profiled in pathologist-selected tumor regions using novel Automated Quantitative Analysis algorithms. Selected biomarker signatures, PD-1/PD-L1 interaction score, and IDO-1/HLA-DR coexpression were evaluated for anti–PD-1 treatment outcomes. Results: In the discovery cohort, PD-1/PD-L1 interaction score and/or IDO-1/HLA-DR coexpression was strongly associated with anti–PD-1 response (P = 0.0005). In contrast, individual biomarkers (PD-1, PD-L1, IDO-1, HLA-DR) were not associated with response or survival. This finding was replicated in an independent validation cohort: patients with high PD-1/PD-L1 and/or IDO-1/HLA-DR were more likely to respond (P = 0.0096). These patients also experienced significantly improved progression-free survival (HR = 0.36; P = 0.0004) and overall survival (HR = 0.39; P = 0.0011). In the combined cohort, 80% of patients exhibiting higher levels of PD-1/PD-L1 interaction scores and IDO-1/HLA-DR responded to PD-1 blockers (P = 0.000004). In contrast, PD-L1 expression was not predictive of survival. Conclusions: Quantitative spatial profiling of key tumor-immune suppression pathways by novel digital pathology algorithms could help more reliably select melanoma patients for PD-1 monotherapy. Clin Cancer Res; 24(21); 5250–60. ©2018 AACR.
Changes in carotid artery intima-media thickness 3 years after cessation of menopausal hormone therapy: follow-up from the Kronos Early Estrogen Prevention Study
Miller, Virginia M. , Hodis, Howard N., Lahr, Brian D. , Bailey, Kent R. , Jayachandran, Muthuvel

Mayo Clinic

Menopause | July 16, 2018 | Volume: 26 | Issue: 1 | Pages: 24-31

10.1097/gme.0000000000001167 | PMID 30020254 Get It

AbstractObjective:Little is known regarding the progression of preclinical atherosclerosis upon cessation of menopausal hormone therapy (MHT). This study evaluated changes in carotid artery intima-media thickness (CIMT) in a subgroup of participants during 4 years and 3 years after the Kronos Early Estrogen Prevention Study (KEEPS).Methods:Of the women enrolled in KEEPS at Mayo Clinic (n = 118), a subset (n = 76) agreed to participate in this follow-up study. KEEPS MHT assignments were placebo (PBO),n = 33; transdermal 17β-estradiol (tE2),n = 23; and oral conjugated equine estrogens group (oCEE),n = 20. CIMT was measured by B-mode ultrasonography. Longitudinal analysis of CIMT was performed using all available data from pre-, on-, and post-treatment periods.Results:At 7 years, median age of participants was 60.2 years; median time since menopause was 8.5 years. The mean difference in rates of increase was significantly greater over the post- than on-treatment period within the oCEE group (0.010 [0.002-0.017] mm/y), but not within the PBO (0.006 [−0.001 to 0.012] mm/y;P = 0.072)or tE2(0.002 [−0.005 to 0.010] mm/y;P = 0.312) groups. There were, however, no significant treatment differences in the linear trends over those intervals (P = 0.524).Conclusions:Cessation of MHT at the lower doses and formulations used in KEEPS did not appear to alter the trajectory of CIMT over a 3-year follow-up period. CIMT, however, increased in all groups over the entire 7-year timeframe as expected with age and timing of menopause possibly key contributors.
Cryptic ETV6–PDGFRB fusion in a highly complex rearrangement of chromosomes 1, 5, and 12 due to a chromothripsis-like event in a myelodysplastic syndrome/myeloproliferative neoplasm
Singh, Zeba N. , Richards, Stephanie , Chaer, Firas El , Gudipati, Mary A. , Waters, Elizabeth, Koon, Sarah, Webley, Matthew, Pitel, Beth A. , Hoppman, Nicole L., Baer, Maria R. , Zou, Ying , Pitel, Beth, Pitel, Beth A , Zou, Ying S , Duong, Vu H.

Mayo Clinic

Leukemia & Lymphoma | July 11, 2018 | Volume: 60 | Issue: 5 | Pages: 1304-1307

10.1080/10428194.2018.1480774 | PMID 29992858 Get It