Citations

Clear

6423 citation(s) found for "Su, Christopher".

Abstract 20188: The Effect of Disclosing Genetic Risk for Coronary Heart Disease on Perceived Personal Control and Genetic Counseling Satisfaction: The MI-GENES Study
Robinson, Christopher L , Jouni, Hayan, Kruisselbrink, Teresa , Christensen, Kurt D. , Green, Robert C. , Kullo, Iftikhar J.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 130 | Issue: suppl_2 | Pages: No page available

10.1161/circ.130.suppl_2.20188 Get It

Background: Perceived personal control (PPC) represents the belief that a person can alter his/her own situation or state. Higher PPC has been associated with increased health-related quality of life and helps facilitate healthy behavioral changes. We investigated whether disclosure of coronary heart disease (CHD) genetic risk influences PPC and genetic counseling satisfaction (GCS) in the myocardial infarction genes (MI-GENES) study, a randomized controlled trial of disclosing genetic risk of CHD. Methods: Participants (40-65 year-old, at intermediate 10-year CHD risk, and not on statins) were randomized to receive estimated 10-year risk of CHD based on their Framingham Risk Score (FRS) or FRS plus a 28 SNP genetic risk score (FRS*GRS). CHD risk was disclosed in each arm by a genetic counselor during a 30-minute scripted session that included a discussion of the impact of family history on CHD risk. For FRS*GRS participants, the genetic counselor also reviewed how their genetic risk score altered their FRS. Each participant then met with a physician to engage in shared-decision making regarding the need for statin therapy. Afterwards, study participants were asked to complete validated surveys to assess PPC and GCS. The 9-item PPC questionnaire was scored 0-9, with higher scores indicating greater control beliefs. The 5-item GCS questionnaire was scored 0-10, with greater scores indicating greater satisfaction with the disclosure session. Results: 207 patients (mean age 58.8±5 years, 46.7% males) were randomized to receive either FRS or FRS*GRS. Patients randomized to receive FRS*GRS had higher PPC compared to FRS although the absolute difference was small (8.85±0.77 vs. 8.54±1.31, P=0.016). Patients randomized to receive FRS*GRS also had a higher GCS score than FRS patients (9.08±2.67 vs. 8.3±3.67, P=0.050]. Conclusions: Disclosure of genetic risk for CHD did not adversely affect PPC or GCS. In fact, patients who received CHD genetic risk information had higher PPC and GCS. Our findings suggest that disclosure of CHD genetic risk is appreciated by patients and may empower them to improve health-related behaviors.
Abstract 18318: Percutaneous Epicardial Access for Mapping and Ablation is Feasible in Patients With Prior Cardiac Surgery, Including Coronary Bypass Surgery
Killu, Ammar M. , Ebrille, Elisa , Munger, Thomas M. , Packer, Douglas L. , Friedman, Paul A. , Mulpuru, Siva K. , Asirvatham, Samuel J. , McLeod, Christopher J.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 130 | Issue: suppl_2 | Pages: No page available

10.1161/circ.130.suppl_2.18318 Get It

Introduction: Prior cardiac surgery, especially the presence of coronary bypass grafts, is thought to preclude percutaneous epicardial access (EpiAcc) and, due to limited catheter maneuverability, mapping and ablation. The objective of our study was to evaluate the feasibility and safety of EpiAcc in patients with prior cardiac surgery. Methods: We retrospectively analyzed all patients who underwent EpiAcc as part of an ablation procedure between 01/01/2004-06/30/2013 at Mayo Clinic, Rochester, MN. All had documented VT or recurring, symptomatic PVCs. Baseline clinical characteristics and procedural characteristics were collected. Results: Of 162 patients that underwent EpiAcc, 18 had prior cardiac surgery (mean age 61 years, all male). This included 10 CABG, 2 epicardial ICD placement, 5 valve surgery (3 aortic valve, 2 mitral valve), 2 septal myectomy, 1 aortic arch replacement, 1 myocardial bridge unroofing and 1 myocardial perforation repair (3 patients had multiple procedures). Access was successful in 12 patients (66.7%); the inferior approach was utilized in 78%. Of patients with prior CABG, successful access was attained in 6 (60%). The average procedural time was 441.6 ± 141.3 minutes. Adhesiolysis was required in 10 patients with the sheath, access wire, pigtail catheter or ablation catheter. Intra-procedural coronary angiography was performed in 8 patients. There were a total of 45 VTs/PVCs ablated in 18 patients (average 2.5 ± 1.7), mean cycle length 463.6 ± 95.9ms. Ultimately, 12 patients (66.7%) underwent endocardial only ablation, 1 (5.5%) had epicardial only ablation while 5 (27.8%) had endocardial/epicardial ablation. The procedure was deemed successful in 13 patients (72.2%). Four patients had bleeding complications (pericardial effusion, pericardial hematoma, hemoperitoneum and pericardial tamponade [the latter required repair of the RV wall]). In patients with coronary grafts, there was no evidence of acute graft disruption. Conclusions: Percutaneous epicardial access is feasible in patients with previous cardiac surgery, including CABG. However, adhesiolysis is frequently required. Although the risk of coronary graft injury is low, life-threatening complications may occur.
Assessment of serological assays for identifying high titer convalescent plasma
Farnsworth, Christopher W , Hock, Karl , Chen, Rita E. , O’Halloran, Jane A. , Goss, Charles W. , Rauseo, Adriana M. , Theel, Elitza S. , Diamond, Michael , Case, James Brett , Presti, Rachel M. , Ellebedy, Ali H. , Henderson, Jeffrey P.

Mayo Clinic

Transfusion | July 3, 2021 | Volume: 61 | Issue: 9 | Pages: 2658-2667

10.1111/trf.16580 | PMID 34216156 Get It

Abstract Background The COVID‐19 pandemic has been accompanied by the largest mobilization of therapeutic convalescent plasma (CCP) in over a century. Initial identification of high titer units was based on dose–response data using the Ortho VITROS IgG assay. The proliferation of severe acute respiratory syndrome coronavirus 2 serological assays and non‐uniform application has led to uncertainty about their interrelationships. The purpose of this study was to establish correlations and analogous cutoffs between multiple serological assays. Methods We compared the Ortho, Abbott, Roche, an anti‐spike (S) ELISA, and a virus neutralization assay. Relationships relative to FDA‐approved cutoffs under the CCP emergency use authorization were identified in convalescent plasma from a cohort of 79 donors from April 2020. Results Relative to the neutralization assay, the spearman r value of the Ortho Clinical, Abbott, Roche, anti‐S ELISA assays was 0.65, 0.59, 0.45, and 0.76, respectively. The best correlative index for establishing high‐titer units was 3.87 signal‐to‐cutoff (S/C) for the Abbott, 13.82 cutoff index for the Roche, 1:1412 for the anti‐S ELISA, 1:219 by the neutralization assay, and 15.9 S/C by the Ortho Clinical assay. The overall agreement using derived cutoffs compared to a neutralizing titer of 1:250 was 78.5% for Abbott, 74.7% for Roche, 83.5% for the anti‐S ELISA, and 78.5% for Ortho Clinical. DISCUSSION Assays based on antibodies against the nucleoprotein were positively associated with neutralizing titers and the Ortho assay, although their ability to distinguish FDA high‐titer specimens was imperfect. The resulting relationships help reconcile results from the large body of serological data generated during the COVID‐19 pandemic.
Abstract 18299: Device Selection: Does Ventricular Size Matter in LVAD Recipients?
Maltais, Simon, Xu, Meng , Desai, Shashank , Singh, Ramesh , Haglund, Nicholas, Stulak, John M., Salerno, Christopher T. , Shah, Palak , Dunlay, Shannon M. , Aaronson, Keith D. , Davis, Mary B, Pagani, Francis D. , Cowger, Jennifer

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.18299 Get It

Introduction: Axial and centrifugal-flow left ventricular assist devices (LVAD) have varied response to changes in loading conditions. Whether ventricular size modulates the response to LVAD therapy between the axial flow Heartmate II (HMII) and centrifugal flow Heartware (HVAD) is unknown. Hypothesis: Adverse event and survival rates between devices are affected by recipient pre-op left ventricular end-diastolic diameter (LVEDD). Methods: Data on 1,149 continuous-flow LVAD recipients from May 2004 to May 2015 was pooled from the Mechanical Circulatory Support Research Network (MCSRN). The effect of pre-op LVEDD on the instantaneous hazard of death and adverse events was evaluated between HMII (n=864) and HVAD (n=283). Results: The average LVEDD was 7.0cm and did not differ between the device recipients. Patients with a smaller LVEDD (≤ 6.3cm) were more likely female 39% v. 24% (p < 0.0001) and to have an ischemic cardiomyopathy (30% v. 24%, p = 0.045). For every 1cm increase in pre-op LVEDD, the adjusted hazard ratio (HR) for mortality increased with HVAD (HR 1.31, 95% CI 0.94-1.82, p = 0.005) and decreased with HMII (HR 0.78, 95% CI 0.67-0.92, p = 0.005), Figure 1a. Other predictors of mortality included age (HR 1.31, 95% CI 1.12 - 1.53 per 10y, p < 0.001) and bilirubin (HR 1.15, 95% CI 0.94-1.42 per mg/dL, p = 0.027). LVEDD by device type interaction was not a significant predictor of gastrointestinal bleeding or pump thrombosis. The risk of stroke increased with LVEDD for HVAD and decreased for HMII, but this did not reach statistical significance, Figure 1b. Ischemic etiology of heart failure (HR 1.7 95% CI 1.14 - 2.55, p = 0.01) and HVAD device use (HR 1.47 95% CI 1.00 - 2.17, p = 0.03) were significant predictors of stroke. Conclusions: Our data suggest important differences exist in patient outcomes between HMII and HVAD based on pre-op ventricular size. Studies are needed to determine if these differences in outcome are due to device or flow-specific differences in patient support.
Abstract 17277: Apixaban Use in Patients With Atrial Fibrillation With Bioprosthetic Valves: Insights From ARISTOTLE
Rao, Meena P., Wojdyla, Daniel , Hanna, Michael G. , Wallentin, Lars , Pokorney, Sean D. , Gersh, Bernard J. , Lópes, Renato D. , Lewis, Basil S. , Avezum, Álvaro , Alexander, John H. , Granger, Christopher B.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.17277 Get It

Background: The package insert for apixaban recommends against its use for stroke prevention in patients with atrial fibrillation (AF) with prosthetic heart valves. There are no published data on the use of apixaban in patients with AF with bioprosthetic valves. This analysis provides preliminary exploratory data on the safety and efficacy of apixaban in these patients. Methods: The ARISTOTLE trial randomized patients with AF to apixaban versus warfarin, and patients with a history of bioprosthetic valve replacement were eligible for inclusion in the trial. In this secondary analysis, baseline characteristics of patients with bioprosthetic valves were compared between apixaban and warfarin patients using Wilcoxon tests for continuous variables and chi-square tests for categorical variables. Unadjusted endpoints were compared between randomized treatments using a Cox regression model. With data collection on these valve patients ongoing, this interim report represents 82 of 260 patients with a history of valve surgery from ARISTOTLE. Results: Among 82 patients with bioprosthetic valves, 41 patients each were in the apixaban and warfarin arms. The patients had a median age of 78 years (vs. 70 years in overall trial), 18% had prior stroke (vs. 19% in overall trial), and 41% had concomitant aspirin use (vs. 31% in overall trial). Other than a higher rate of hypertension in the warfarin arm (98% vs. 81%, p=0.03), there were no statistically significant differences in baseline characteristics between the two groups. There were few events in patients with bioprosthetic valves. There were 2 stroke events, and there were no statistically significant differences between the apixaban and warfarin groups for major bleeding, stroke/systemic embolism, all-cause death, or cardiovascular death (Table). Conclusions: Among the small number of patients in ARISTOTLE with bioprosthetic valves, there were few events with similar event rates in both the apixaban and warfarin groups.
Abstract 16138: Chest and Cardiac Compression on CT/MRI and on TEE Predicts Improvement in Right Heart Chamber Size and Right Ventricular Deformation Post Pectus Excavatum Repair Surgery
Jaroszewski, Dawn E. , Lester, S.C., Unzek, Samuel , Wilansky, Susan , Chaliki, Hari P. , Appleton, Christopher P., Mookadam, Farouk , Naqvi, Tasneem Z. , Chao, Chieh‐Ju , Gotway, Michael B. , Lester, Steven

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.16138 Get It

Background: Pectus excavatum (PE) deformity involves posterior depression of the sternum and adjacent costal cartilages. The relationship of CT/MRI chest cardiac compression indices used as indications for surgical repair of PE with echocardiographic findings and with improvement in cardiac chamber compression and function post PE repair is unknown. Methods: We evaluated right atrial (RA) size, tricuspid annulus (TA size, right ventricular (RV) outflow tract size as well as RV 2D strain on intra-operative trans-esophageal echocardiography (TEE) immediately pre and post surgical PE repair. Inspiratory and expiratory Haller Index (HI) and cardiac compression indices (CCI) were measured on pre op CT/MR scans (Figure). Offline measurement of chamber dimensions on TEE images was performed and Speckle tracking strain measurements were made using Syngo US Workplace software (Siemens). P<0.05 was considered significant. Results: 60 patients, 73% male, 27% female, age 33.6±10.3 yrs underwent PE repair following CT/MRI from 2010-2014 (Figure). There was a strong correlation between expiratory CT/MRI chest AP diameter and pre-op RA size (panel A). Pre op RA and TA compression on TEE inversely correlated with pre op RV global longitudinal strain rate(RVGLSR) (panels B & C). CCI predicted improvement in RA size post PE repair (panels D & E). In addition pre op RA size on TEE correlated with improvement in RVGLSR post PE repair surgery (panel F). Conclusion: In patients with PE deformity, pre surgical CCI correlated with right-sided cardiac chamber compression on pre op TEE. Severity of chest and cardiac compression also predicted magnitude of improvement in right-sided chamber size and RV longitudinal deformation post PE repair. Our findings provide insight regarding the beneficial effects of PE surgery on right heart chamber compression and improvement in RV function and the important role of intraoperative TEE for patients undergoing PE repair surgery.
Abstract 15331: Ventricular Conduction and Repolarization Prolongation Noted During Right Ventricular Pacing as Predictors of Ventricular Arrhythmias and Cardiac Mortality in Subjects With Cardiomyopathy
Carpio, Freddy Del, Gharacholou, S. Michael , Scott, Christopher S, Nkomo, Vuyisille T., Nkomo, Vuyisile T. , López-Jiménez, Francisco , Asirvatham, Samuel J.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.15331 Get It

Introduction: Clinical predictive value of transient prolonged ventricular conduction and repolarization during right ventricular (RV) pacing have not been studied. Hypothesis: Ventricular conduction and repolarization prolongation during RV pacing predict risk of arrhythmic and mortality events. Methods: Electrophysiology studies in 501 patients with cardiomyopathy (CM) were reviewed. Duration changes of QRS and QT interval during pacing from the RV apex were measured. Subjects were followed up for a mean of 3.2 years for arrhythmic events and total mortality. Results: Participants had a mean age 65 yrs, 80% male, 74% funcional class II or III, and a mean EF of 33.1%. A paced QRS duration > 190 ms was associated with more severe CM and in multi-variable analysis it was associated with a 3.5 times higher risk of ventricular arrhythmias or appropriate defibrillator therapy (HR 3.5, 95% CI 2.3-5.4, p<0.01) and 2.6 times higher risk of total mortality or arrhythmic events (HR 2.6, 95% CI 2.3-3.4, p<0.01) compared to a paced QRS duration <190 ms, independent of baseline EF or baseline QRS duration, and after adjustment for electrophysiology study results, baseline functional class, type of cardiomyopathy and other relevant clinical factors. Similarly a QTc interval during RV pacing > 620 ms was associated with a 2.7 times higher risk of arrhythmic events compared to a QTc interval during RV pacing < 620 ms. Conclusions: Prolongation of ventricular conduction (QRS > 190 ms) and repolarization (QTc > 620 ms) observed during RV pacing in subjects with CM are associated with higher risk of arrhythmic events, defibrillator therapies and all-cause mortality.
Abstract 12776: Long Term Mortality With Right Ventricular Apical Versus Septal Pacing
Witt, Chance M. , Lenz, Charles J., Shih, Henry, Ebrille, Elisa , Rosenbaum, Andrew , Aung, Htin , Zyl, Martin van , Manocha, Kevin K. , Deshmukh, Abhishek , Hodge, David O. , Aung, Htin, Asirvatham, Samuel J. , McLeod, Christopher J.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.12776 Get It

Introduction: Right ventricular apical (RVA) pacing appears to have detrimental effects on cardiac function and long term outcomes. Right ventricular non-apical (RVNA) pacing, especially in the septal position, has been postulated as an alternative that may lead to less morbidity and mortality. Prior studies have shown conflicting results and been limited by small numbers and short follow-up. We aimed to determine if right ventricular septal lead position was associated with a reduction in long-term mortality compared to RVA lead position. Methods: Patients who underwent dual-chamber pacemaker implantation from 2004 through 2013 were evaluated for right ventricular lead position based on chest radiographs. Lead positions were divided in to apical or non-apical. Non-apical lead positions were subdivided to isolate a septal lead position group. Mortality was compared between these groups. Results: During the study period, 3456 patients underwent dual-chamber pacemaker placement and had images appropriate for lead position evaluation. The group was 53.5% male with a mean age of 74 ± 13 years. RVNA lead position was found in 976 (28.2%) patients, including 243 (7.0%) with a septal position. There was no significant difference in age or prior heart failure diagnosis between groups. Kaplan-Meier survival analysis did not reveal a significant difference in mortality between patients with RVA versus RVNA lead position during 5 year follow-up (p = 0.82). However, septal lead position was associated with a significantly lower mortality compared with RVA position (p = 0.03) (figure). Conclusions: Right ventricular septal lead position is associated with a lower long-term mortality than RVA lead position. This has substantial implications regarding the preferred site for ventricular pacing lead placement.
Abstract 12732: Risk of Heart Failure After Contemporary Radiotherapy for Breast Cancer in the Community
Finley, Randi R., Yan, Elizabeth , Petersen, Ivy A. , Redfield, Margaret M. , Saiki, Hirofumi , Scott, Christopher G.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.12732 Get It

Background: Contemporary breast cancer radiotherapy (RT) results in variable cardiac radiation exposure. While cardiomyocytes are radio-resistant, radiation induces coronary microvascular endothelial damage and inflammation which may ultimately lead to myocardial inflammation, ischemia and fibrosis and put patients at risk for heart failure (HF) and particularly, HF with preserved ejection fraction (HFpEF). Methods: Community based (Olmsted County, MN), HF case-control study of contemporary (1999-2014) breast cancer RT patients with CT-based RT planning for precise mean cardiac radiation dose (MCRD) calculation. HF cases (n=66) and controls (n=129) were matched (1:2) for age at RT, HF risk factors, tumor side and chemotherapy use. Matched controls and cases had identical follow-up (index interval). Proportion of HF and clinical characteristics in categories of MCRD were reported (table) and conditional logistic regression was used to estimate the HF odds ratio (OR) associated with MCRD as a continuous variable. Results: Of the 66 HF cases, 46 (70%) had HFpEF and 20 (30%) had HF with reduced ejection fraction (HFrEF). The proportion of patients with HF (any) or HFpEF increased and proportion with HFrEF tended to increase with increasing MCRD. The prevalence of HF risk factors (hypertension, diabetes, coronary disease) at time of RT did not vary by MCRD while left sided tumor, cancer stage and adriamycin use increased with increasing MCRD. The OR per 1 unit increase in log MCRD was 3.71 (1.98, 6.94) for total HF (p<0.001), 4.91 (1.93, 9.09) for HFpEF (p<0.001) and 2.78 (0.91, 8.47) for HFrEF (p=0.07). The mean index interval was 5.0±3.2 years. Conclusion: Cardiac radiation incident to contemporary breast RT increases the risk of HF, and particularly HFpEF over a short post-RT interval. These data may guide use of proton beam therapy in breast cancer. These data also provide support for the role of coronary microvascular compromise in the pathophysiology of HFpEF.
Abstract 12112: Clinical Outcomes of Percutaneous Epicardial Ablation
Killu, Ammar M. , Sugrue, Alan , Hodge, David O. , Munger, Thomas M. , Mulpuru, Siva K. , Packer, Douglas L. , Friedman, Paul A. , Al‐Hijji, Mohammed , McLeod, Christopher J. , Asirvatham, Samuel J.

Mayo Clinic

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.12112 Get It

Introduction: Percutaneous epicardial access (EAc) is increasingly performed as part of VT/PVC ablation, especially in those that have failed prior ablation. We aimed to delineate the outcomes of EAc. Methods: We retrospectively analyzed individuals undergoing EAc for arrhythmia ablation between June 2004 and July 2014. Acute procedural success was defined as elimination/non-inducibility of the clinical arrhythmia after ablation; clinical success was defined as absence of symptoms/arrhythmia. Results: Of 175 patients, 126 (72%) were male with a mean age of 52.8±15.7 years. Eighty-three (47.4%) patients had NICM, 25 (14.3%) had ICM and 34 (19.4%) had normal hearts. Baseline EF was 44±16%. Patients had failed an average of 1.7±1.2 antiarrhythmic drugs; 139 patients (79%) had failed prior endocardial (endo) ablation (average 1.3±1.1). Six (3.4%) had prior EAc and 18 (10.3%) prior cardiac surgery. The indication for ablation was VT or PVC in 113 (64.6%) and 60 (34.3%) patients, respectively. Successful access was obtained in 168 (98%) patients. Anterior access, inferior access, or both, was utilized in 89 (52.7%), 77 (45.6%) and 2 (1.2%) patients, respectively. There were an average of 2.7±2.2 VT/PVCs identified, and 1.6±1.1 ablated. Endo, epicardial (epi) or combined ablation was performed in 58 (33.1%), 14 (8%), and 100 (57.1%) patients, respectively; 3 did not undergo ablation. Procedural success was obtained in 158 of 173 (91.3%) patients for whom data was available. At 12 months, clinical success was maintained in 62% with no difference between endo, epi or combined ablation (figure). Cardiac tamponade requiring repeat EAc occurred in 12 (6.9%) patients. There were no procedural related deaths. Conclusion: Epicardial access is feasible in almost all patients with no prior cardiac surgery, and permits acute procedural success in 91.3% of patients, most of whom had failed previous ablation. Furthermore, complications are relatively infrequent in this complex cohort.