Background: Recent literature has suggested that capsular closure following hip arthroscopy restores native hip-joint kinematics and may lead to better patient-reported outcomes, especially in high-level athletes 1–4 . Description: Capsular closure of the hip occurs following standard hip arthroscopy, which typically includes labral repair and osteoplasty of the femoral neck and/or acetabulum accessed through an interportal capsulotomy. Viewing through an anterolateral portal with use of a 70° scope, a suture-passing device loaded with a #2 FiberWire (Arthrex) is passed down into the mid-anterior portal. The suture is then passed through the anterior aspect of the proximal leaflet of the capsulotomy. The suture-passing device is then passed through the distal leaflet, and the previously passed suture is grasped and brought out of the cannula. The capsular bites are typically made 1 cm from the edge of the capsule. This process is repeated 1.5 cm posteriorly to the initially placed suture. Typical capsular closure takes 2 to 3 sutures for complete closure. Once the sutures are passed, they are tied with use of half-hitches and excess suture is cut. Alternatives: Alternatives include capsular plication, which is more frequently performed in the setting of capsular laxity preoperatively or connective-tissue disorders 5,6 . Additionally, there is evidence suggesting that leaving the capsulotomy unrepaired may lead to similar results in select populations 7 . Rationale: This procedure is performed largely secondary to the restoration of native anatomy and kinematics of the hip joint 3,8 . Arthroscopy of the hip requires a capsulotomy in order to access the joint, unlike other, more superficial joints such as the shoulder. Capsular closure is often technically challenging and adds length to the procedure. However, recent literature has shown improved patient-reported outcomes with routine capsular closure specifically among high-level athletes 9,10 . Expected Outcomes: Routine capsular closure has been associated with good mid-term patient-reported outcomes 10 . Patients who undergo hip arthroscopy and routine capsular closure can expect to meet the minimal clinically important difference and the patient acceptable symptomatic state for the modified Harris hip score and the Hip Outcome Score Activities of Daily Living component. Patients who participate in high-level sports activities may experience a quicker return to play and more normal kinematics with routine capsular closure. Important Tips: Clear off the capsule immediately following the capsulotomy. Utilize an over-the-top view to better visualize the capsule. Place the sutures from anterior to posterior.
Systematic Review of Technical Variations for Mohs Micrographic Surgery for Melanoma
BACKGROUND Mohs micrographic surgery (MMS) for cutaneous melanoma is becoming more prevalent, but surgical technique varies. OBJECTIVE To define variations in published techniques for MMS for melanoma. METHODS AND MATERIALS A systematic review was performed of PubMed, EMBASE, and Scopus databases to identify all articles describing surgical techniques for MMS for melanoma. Technical details were recorded for the preoperative, intraoperative, and postoperative phases of MMS. RESULTS Twenty-four articles were included. Mohs surgeons vary in how they assess clinical margins, how wide a margin they excise on the first MMS layer, and how they process tissue to determine tumor stage and margin clearance during MMS for melanoma. CONCLUSION Mohs micrographic surgery for melanoma is performed with varied surgical techniques. To establish best practices, additional research is necessary to determine how different techniques affect outcomes.
Correction to: Pain Experience in Pancreatitis: Strong Association of Genetic Risk Loci for Anxiety and PTSD in Patients With Severe, Constant, and Constant-Severe Pain
Variation in Use of Repurposed Medications Among Patients With Coronavirus Disease 2019. From The Society of Critical Care Medicine Discovery Viral Infection and Respiratory Illness Universal Study: Coronavirus Disease 2019 Registry Investigator Group
IMPORTANCE: At the start of the coronavirus disease 2019 pandemic, medications repurposed for management of coronavirus disease 2019 were used in the absence of clinical trial evidence. OBJECTIVES: To describe the variation and evolution in use of repurposed medications for coronavirus disease 2019. DESIGN, SETTING, AND PARTICIPANTS: Observational cohort study of adults hospitalized with coronavirus disease 2019 between February 15, 2020, and April 12, 2021, across 76 United States and international hospitals within the Society of Critical Care Medicine’s Discovery Viral Infection and Respiratory Illness Universal Study coronavirus disease 2019 registry. MAIN OUTCOMES AND MEASURES: Hospital variation was quantified using multivariable adjusted random effects logistic regression models and unsupervised clustering. Repurposed medications included antivirals, corticosteroids, hydroxychloroquine, immunomodulators, and therapeutic dose anticoagulants. RESULTS: Among 7,069 adults hospitalized with coronavirus disease 2019, 1,979 (28%) received antivirals, 2,876 (41%) received corticosteroids, 1,779 (25%) received hydroxychloroquine, 620 (9%) received immunomodulators, and 2,154 (31%) received therapeutic dose anticoagulants. Contribution of hospital site to risk-adjusted variation was 46% for antivirals, 30% for corticosteroids, 48% for hydroxychloroquine, 46% for immunomodulators, and 52% for therapeutic dose anticoagulants. Compared with the early pandemic, the later pandemic practice phenotypes converged with increased use of antivirals (odds ratio, 3.14; 95% CI, 2.40–4.10) and corticosteroids (odds ratio, 5.43; 95% CI, 4.23–6.97), with decreased use of hydroxychloroquine (odds ratio, 0.02; 95% CI, 0.01–0.04) and immunomodulators (odds ratio, 0.49; 95% CI, 0.34–0.70). There was no clinically significant change in the use of therapeutic dose anticoagulants (odds ratio, 1.01; 95% CI, 1.01–1.02). There were no differences in risk-adjusted mortality between hospitals with high rates of repurposed medication use compared with hospitals with low rates of use. CONCLUSIONS AND RELEVANCE: Hospital variation in the use of repurposed medications varied widely across hospitals early in the pandemic and later converged with the emergence of randomized clinical trials. Platforms developed for rapid activation and enrollment in clinical trials of repurposed medications are needed prior to the next pandemic to expedite effective, evidence-based practice.
Clinical and Infection Prevention Applications of Severe Acute Respiratory Syndrome Coronavirus 2 Genotyping: an Infectious Diseases Society of America/American Society for Microbiology Consensus Review Document
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) emerged into a world of maturing pathogen genomics, with more than 2 million genomes sequenced at the time of writing. The rise of more transmissible variants of concern that impact vaccine and therapeutic effectiveness has led to widespread interest in SARS-CoV-2 evolution.
Incorporating Robustness to Imaging Physics into Radiomic Feature Selection for Breast Cancer Risk Estimation
Digital mammography has seen an explosion in the number of radiomic features used for risk-assessment modeling. However, having more features is not necessarily beneficial, as some features may be overly sensitive to imaging physics (contrast, noise, and image sharpness). To measure the effects of imaging physics, we analyzed the feature variation across imaging acquisition settings (kV, mAs) using an anthropomorphic phantom. We also analyzed the intra-woman variation (IWV), a measure of how much a feature varies between breasts with similar parenchymal patterns—a woman’s left and right breasts. From 341 features, we identified “robust” features that minimized the effects of imaging physics and IWV. We also investigated whether robust features offered better case-control classification in an independent data set of 575 images, all with an overall BI-RADS® assessment of 1 (negative) or 2 (benign); 115 images (cases) were of women who developed cancer at least one year after that screening image, matched to 460 controls. We modeled cancer occurrence via logistic regression, using cross-validated area under the receiver-operating-characteristic curve (AUC) to measure model performance. Models using features from the most-robust quartile of features yielded an AUC = 0.59, versus 0.54 for the least-robust, with p < 0.005 for the difference among the quartiles.
Investigation of the correlation between immature reticulocyte fraction and reticulocyte hemoglobin content with common tests for iron deficiency anemia
Abstract Reticulocyte hemoglobin content (Ret-He, the hemoglobin within reticulocytes or immature red blood cells) and immature reticulocyte fraction (IRF, the immature fraction of the absolute-reticulocyte-count) are tests that provide insight into erythropoiesis and iron status earlier than conventional iron studies offering the added benefit of not being acute-phase-reactants. Studies have shown that Ret-He is a diagnostic marker for iron-deficiency-anemia (IDA), but fewer studies have investigated IRF. Our laboratory is currently planning to report these parameters when reticulocyte is ordered. Since these are new parameters, we wanted to investigate their overall correlation with complete blood count (CBC) and other iron studies to gain a better appreciation of their utility in our patient population. The aim of this study was to compare the overall correlation of Ret-He and IRF with seven tests used in the evaluation of IDA. To our knowledge these parameters have not all been directly correlated within a single study. CBC and reticulocytes were quantified using XN 9000 hematology analyzers (Sysmex Corporation), ferritin (DXI 800, Beckman Coulter Inc.), and % iron-saturation (measured using total iron-binding-capacity (TIBC)=transferrin*1.18 on Cobas 6000, Roche Diagnostics). Two de-identified cohorts of patients undergoing physician-ordered reticulocyte testing were used for this analysis. Dataset 1 (DS1): (N=2026 from Mayo Clinic Florida) had Ret-He and IRF compared to absolute-reticulocyte-count (Ret), ferritin and % iron saturation. Dataset 2 (DS2): (N=3990 from Mayo Clinic Rochester) had Ret-He and IRF compared to the red-cell-indices of the CBC including hemoglobin (Hgb), mean-corpuscular-volume (MCV), mean-corpuscular-hemoglobin (MCH), and mean-corpuscular-hemoglobin-concentration (MCHC). Correlation coefficients were calculated using Spearman rank-order (ρ) wherein values below +/-0.39 are weak, between +/-0.40-0.59 are considered moderate, and values above +/-0.60 are considered strong. For DS1, Ret-He demonstrated the following correlations: Ret (ρ=0.01), ferritin (ρ=0.33), % iron saturation (ρ=0.63). IRF demonstrated: Ret (ρ=0.46), ferritin (ρ=-0.05), % iron saturation (ρ=-0.22). For DS2, Ret-He demonstrated the following correlations: Hgb (ρ=0.17), MCV (ρ=0.64), MCH (ρ=0.74), MCHC (ρ=0.56). IRF demonstrated Hgb (ρ=-0.41), MCV (ρ=0.10), MCH (ρ=0.04), MCHC (ρ=-0.11). Ret-He and IRF demonstrated different correlative profiles suggesting they may have differing uses. Ret-He was strongly positively-correlated with % iron saturation, MCV, MCH and moderately positively-correlated with MCHC. These positive-correlations are consistent with relationships established in the literature. Interestingly, Ret-He was only weakly correlated with ferritin, possibly owing to ferritin being an acute-phase-reactant. IRF had a moderate positive correlation with Ret and moderate inverse correlation with Hgb. Both of these IRF relationships are consistent with other reports, but both relationships have not been shown in the same study before, preventing direct comparison until now. The literature suggests IRF may have more potential in monitoring treatment than in diagnosis. One limitation of these datasets is their lack of clinical correlation such as established iron-deficiency, anemia status, or treatment information.