Citations

Clear

3053 citation(s) found for "Patel, P".

Rapid and Sensitive Detection of Shiga Toxin-Producing Escherichia coli from Nonenriched Stool Specimens by Real-Time PCR in Comparison to Enzyme Immunoassay and Culture
Grys, Thomas E. , Sloan, Lynne M., Rosenblatt, Jon E., Patel, Robin , Patel, Robin , Grys, Thomas E

Mayo Clinic

Journal of Clinical Microbiology | May 14, 2009 | Volume: 47 | Issue: 7 | Pages: 2008-2012

10.1128/jcm.02013-08 | PMID 19439539 Get It

ABSTRACT Shiga toxin (Stx)-producing Escherichia coli (STEC) bacteria are a frequent cause of food-borne gastroenteritis, hemorrhagic colitis, and hemolytic uremic syndrome. Because antimicrobial agents are generally contraindicated in patients infected with STEC, a sensitive and specific diagnostic test with rapid turnaround is essential. Current culture methods may fail to detect non-O157 STEC. We evaluated a Stx gene real-time PCR assay using hybridization probes and the LightCycler instrument with 204 prospectively collected stool specimens, which were also tested for Stx by enzyme immunoassay (EIA) (ProSpecT STEC; Remel, Lenexa, KS) and by culturing on chromogenic agar (Chromagar O157; BD BBL, Sparks, MD). In addition, 85 archived stool specimens previously tested for Stx (by EIA) and/or E. coli O157:H7 (by culture) were tested by PCR. Sample preparation for PCR included mixing the stool in sterile water and extraction of nucleic acid using the MagNA Pure LC instrument (Roche Diagnostics). The PCR assay had 100% sensitivity and specificity compared to EIA and culture for specimens collected prospectively (4 of 204 specimens were positive) and compared to culture and/or EIA for archival specimens (42 of 85 specimens were positive). Both the EIA and PCR produced positive results from a specimen containing an O103 serotype STEC in the prospective specimens, and the PCR test detected three positive specimens that contained nonviable STEC in the archived specimens. The PCR assay demonstrated 100% sensitivity and specificity compared to EIA and/or culture and more rapid turnaround than either EIA or culture.
Allergic airway inflammation and susceptibility to pneumococcal pneumonia in a murine model with real-timein vivoevaluation
Kang, C-I, Rouse, Mark S., Patel, Robin , Kita, Hirohito , Juhn, Young J. , Kita, H , Patel, Robin

Mayo Clinic

Clinical and Experimental Immunology | April 3, 2009 | Volume: 156 | Issue: 3 | Pages: 552-561

10.1111/j.1365-2249.2009.03925.x | PMID 19438610 Get It

SummaryThe relationship between allergic airway inflammation and pneumococcal pneumonia is not well understood. We assessed susceptibility to experimental pneumococcal pneumonia in mice with and without allergic airway inflammation. Susceptibility to pneumococcal pneumonia was evaluated by challenging mice with a bioluminescent Streptococcus pneumoniae strain after sensitization with ovalbumin (OVA), with subsequent monitoring of pneumococcal infection using real-time photonic imaging. Of 46 OVA-sensitized mice challenged with pneumococci, 13 (28%) developed imaging findings consistent with pneumococcal pneumonia. In comparison, 28 (57%) of 49 non-sensitized control mice developed pneumococcal pneumonia (P = 0·005). While none of the control group developed meningitis (0%, none of 28), two mice in the OVA-sensitized group developed meningitis (15·4%, two of 13) (P = 0·09). The mean bacterial count in the lung was significantly lower in the OVA-sensitized than the non-sensitized group (8·26 ± 0·69 versus 9·21 ± 0·67 log10 colony-forming units (CFU)/g, P = 0·002). There was a trend towards the mean bacterial count in the spleen being higher in the OVA-sensitized versus the non-sensitized group (8·14 ± 0·89 versus 7·45 ± 1·07 log10 CFU/g, P = 0·071). A high level of interleukin (IL)-4 in lung homogenates was associated with risk of pneumococcal infection independent of sensitization with OVA (odds ratio: 49·7, 95% confidence interval 2·92-846·5, per increment of 1·0 pg/ml). In the murine model studied, acute allergic airway inflammation reduced susceptibility to pneumococcal pneumonia. IL-4 may increase the risk of pneumococcal pneumonia independently of allergic airway inflammation.
In Vitro Activity of Micafungin against Planktonic and Sessile Candida albicans Isolates
Jacobson, Melissa, Steckelberg, Kathryn E., Piper, Kerryl E., Steckelberg, James M., Patel, Robin , Patel, Robin

Mayo Clinic

Antimicrobial Agents and Chemotherapy | March 24, 2009 | Volume: 53 | Issue: 6 | Pages: 2638-2639

10.1128/aac.01724-08 | PMID 19307371 Get It

ABSTRACT Planktonic and sessile susceptibilities to micafungin were determined for 30 clinical isolates of Candida albicans obtained from blood or other sterile sites. Planktonic and sessile MIC 90 s for micafungin were 0.125 and 1.0 μg/ml, respectively.
Microbiologic Diagnosis of Prosthetic Shoulder Infection by Use of Implant Sonication
Piper, Kerryl E., Jacobson, Melissa, Cofield, Robert H. , Sperling, John W. , Osmon, Douglas R. , McDowell, Andrew , Patrick, Sheila , Steckelberg, James M., Mandrekar, Jayawant N. , Sampedro, Marta Fernández , Patel, Robin , Sánchez‐Sotelo, Joaquín , Patel, Robin

Mayo Clinic

Journal of Clinical Microbiology | March 5, 2009 | Volume: 47 | Issue: 6 | Pages: 1878-1884

10.1128/jcm.01686-08 | PMID 19261785 Get It

ABSTRACT We recently described a sonication technique for the diagnosis of prosthetic knee and hip infections. We compared periprosthetic tissue culture to implant sonication followed by sonicate fluid culture for the diagnosis of prosthetic shoulder infection. One hundred thirty-six patients undergoing arthroplasty revision or resection were studied; 33 had definite prosthetic shoulder infections and 2 had probable prosthetic shoulder infections. Sonicate fluid culture was more sensitive than periprosthetic tissue culture for the detection of definite prosthetic shoulder infection (66.7 and 54.5%, respectively; P = 0.046). The specificities were similar (98.0% and 95.1%, respectively; P = 0.26). Propionibacterium acnes was the commonest species detected among culture-positive definite prosthetic shoulder infection cases by periprosthetic tissue culture (38.9%) and sonicate fluid culture (40.9%). All subjects from whom P. acnes was isolated from sonicate fluid were male. We conclude that sonicate fluid culture is useful for the diagnosis of prosthetic shoulder infection.
Pilot Study of Association of Bacteria on Breast Implants with Capsular Contracture
Pozo, José Luís del , Tran, Nho V. , Petty, Paul M., Johnson, C. H. , Walsh, Molly F., Bite, Uldis, Clay, Ricky P., Mandrekar, Jayawant N. , Piper, Kerryl E., Steckelberg, James M., Patel, Robin , Patel, Robin

Mayo Clinic

Journal of Clinical Microbiology | March 5, 2009 | Volume: 47 | Issue: 5 | Pages: 1333-1337

10.1128/jcm.00096-09 | PMID 19261794 Get It

ABSTRACT Capsular contracture is the most common and frustrating complication in women who have undergone breast implantation. Its cause and, accordingly, treatment and prevention remain to be elucidated fully. The aim of this prospective observational pilot study was to test the hypothesis that the presence of bacteria on breast implants is associated with capsular contracture. We prospectively studied consecutive patients who underwent breast implant removal for reasons other than overt infection at the Mayo Clinic from February through September 2008. Removed breast implants were processed using a vortexing/sonication procedure and then subjected to semiquantitative culture. Twenty-seven of the 45 implants collected were removed due to significant capsular contracture, among which 9 (33%) had ≥20 CFU bacteria/10 ml sonicate fluid; 18 were removed for reasons other than significant capsular contracture, among which 1 (5%) had ≥20 CFU/10 ml sonicate fluid ( P = 0.034). Propionibacterium species, coagulase-negative staphylococci, and Corynebacterium species were the microorganisms isolated. The results of this study demonstrate that there is a significant association between capsular contracture and the presence of bacteria on the implant. The role of these bacteria in the pathogenesis of capsular contracture deserves further study.
Acute Multifocal Posterior Placoid Pigment Epitheliopathy (AMPPPE) Mimicking Migraine with Aura
Spencer, BR, Kunimoto, DY, Patel, Dr Hitesh, Dodick, DW

Mayo Clinic

Cephalalgia | February 10, 2009 | Volume: 29 | Issue: 6 | Pages: 694-698

10.1111/j.1468-2982.2008.01797.x | PMID 19220303 Get It

Unreliable Extended-Spectrum β-Lactamase Detection in the Presence of Plasmid-Mediated AmpC in Escherichia coli Clinical Isolates
Robberts, F. J. Lourens , Kohner, Peggy C., Patel, Robin , Patel, Robin

Mayo Clinic

Journal of Clinical Microbiology | December 25, 2008 | Volume: 47 | Issue: 2 | Pages: 358-361

10.1128/jcm.01687-08 | PMID 19109470 Get It

ABSTRACT The emergence of extended-spectrum β-lactamase (ESBL) and plasmid-mediated AmpC (pAmpC) enzymes in Escherichia coli raises concern regarding accurate laboratory detection and interpretation of susceptibility testing results. Twenty-six cefpodoxime ESBL screen-positive, cefoxitin-resistant E. coli clinical isolates were subjected to clavulanate ESBL confirmatory testing employing disk augmentation, Etest, and the BD Phoenix NMC/ID-132 panel. Phenotypic pAmpC production was assessed by boronic acid disk augmentation. ESBL and pAmpC genes were detected by gene amplification and sequencing. ESBL genes (SHV and/or CTX-M-type genes) were detected in only 7/26 ESBL screen-positive isolates. Of 23 aminophenylboronic acid screen-positive isolates, pAmpC genes were detected in 20 (CMY-2 or FOX-5 genes). High incidences of false-positive ESBL confirmatory results were observed for both clavulanate disk augmentation (9/19) and BD Phoenix (5/19). All were associated with the presence of pAmpC genes with or without TEM-1. Etest performed poorly, as the majority of interpretations were nondeterminable. In addition, false-negative ESBL confirmatory results were observed in isolates possessing concomitant ESBL and pAmpC genes for Etest (four of five), BD Phoenix (three of five), and disk augmentation (one of five). The results indicate poor performance of currently employed ESBL confirmatory methods in the setting of concomitant pAmpC. Some isolates with pAmpC and ESBL genes fell within the susceptible category to extended-spectrum cephalosporins, raising concern over currently employed breakpoints.
The Electricidal Effect: Reduction of Staphylococcus and Pseudomonas Biofilms by Prolonged Exposure to Low-Intensity Electrical Current
Pozo, José Luís del , Rouse, Mark S., Mandrekar, Jayawant N. , Steckelberg, James M., Patel, Robin , Patel, Robin

Mayo Clinic

Antimicrobial Agents and Chemotherapy | October 28, 2008 | Volume: 53 | Issue: 1 | Pages: 41-45

10.1128/aac.00680-08 | PMID 18955534 Get It

ABSTRACT The activity of electrical current against planktonic bacteria has previously been demonstrated. The short-term exposure of the bacteria in biofilms to electrical current in the absence of antimicrobials has been shown to have no substantial effect; however, longer-term exposure has not been studied. A previously described in vitro model was used to determine the effect of prolonged exposure (i.e., up to 7 days) to low-intensity (i.e., 20-, 200-, and 2,000-microampere) electrical direct currents on Pseudomonas aeruginosa , Staphylococcus aureus , and Staphylococcus epidermidis biofilms. Dose- and time-dependent killing was observed. A maximum of a 6-log 10 -CFU/cm 2 reduction was observed when S. epidermidis biofilms were exposed to 2,000 microamperes for at least 2 days. A 4- to 5-log 10 -CFU/cm 2 reduction was observed when S. aureus biofilms were exposed to 2,000 microamperes for at least 2 days. Finally, a 3.5- to 5-log 10 -CFU/cm 2 reduction was observed when P. aeruginosa biofilms were exposed to electrical current for 7 days. A higher electrical current intensity correlated with greater decreases in viable bacteria at all time points studied. In conclusion, low-intensity electrical current substantially reduced the numbers of viable bacteria in staphylococcal or Pseudomonas biofilms, a phenomenon we have labeled the “electricidal effect.”
Nonutility of Repeat Laboratory Testing for Detection of Clostridium difficile by Use of PCR or Enzyme Immunoassay
Aichinger, Elisabeth, Schleck, Cathy D. , Harmsen, William S. , Nyre, Lisa M., Patel, Robin , Patel, Robin

Mayo Clinic

Journal of Clinical Microbiology | September 11, 2008 | Volume: 46 | Issue: 11 | Pages: 3795-3797

10.1128/jcm.00684-08 | PMID 18784320 Get It

ABSTRACT The diagnostic gains of repeat testing for Clostridium difficile by enzyme immunoassay and PCR (i.e., initial negative result followed by positive result) within a 7-day period were 1.9 and 1.7%, respectively. There is little value of repeat testing for C. difficile by enzyme immunoassay or PCR.
Effect of Electrical Current on the Activities of Antimicrobial Agents against Pseudomonas aeruginosa , Staphylococcus aureus , and Staphylococcus epidermidis Biof
Pozo, José Luís del , Rouse, Mark S., Mandrekar, Jayawant N. , Sampedro, Marta Fernández , Steckelberg, James M., Patel, Robin , Patel, Robin

Mayo Clinic

Antimicrobial Agents and Chemotherapy | August 26, 2008 | Volume: 53 | Issue: 1 | Pages: 35-40

10.1128/aac.00237-08 | PMID 18725436 Get It

ABSTRACT Bacterial biofilms are resistant to conventional antimicrobial agents. Prior in vitro studies have shown that electrical current (EC) enhances the activities of aminoglycosides, quinolones, and oxytetracycline against Pseudomonas aeruginosa , Klebsiella pneumoniae , Staphylococcus epidermidis , Escherichia coli , and Streptococcus gordonii . This phenomenon, known as the bioelectric effect, has been only partially defined. The purpose of this work was to study the in vitro bioelectric effect on the activities of 11 antimicrobial agents representing a variety of different classes against P. aeruginosa , methicillin-resistant Staphylococcus aureus (MRSA), and S. epidermidis . An eight-channel current generator/controller and eight chambers delivering a continuous flow of fresh medium with or without antimicrobial agents and/or EC to biofilm-coated coupons were used. No significant decreases in the numbers of log 10 CFU/cm 2 were seen after exposure to antimicrobial agents alone, with the exception of a 4.57-log-unit reduction for S. epidermidis and trimethoprim-sulfamethoxazole. We detected a statistically significant bioelectric effect when vancomycin plus 2,000 microamperes EC were used against MRSA biofilms ( P = 0.04) and when daptomycin and erythromycin were used in combination with 200 or 2,000 microamperes EC against S. epidermidis biofilms ( P = 0.02 and 0.0004, respectively). The results of these experiments indicate that the enhancement of the activity of antimicrobial agents against biofilm organisms by EC is not a generalizable phenomenon across microorganisms and antimicrobial agents.