Citations

Clear

50 citation(s) found for "Zhou, Wei".

Temporal analysis of signaling pathways associated with the development of renovascular hypertension
Grande, Joseph P. , Zhou, Wei , Warner, Gina M., Gray, Catherine , Cheng, Jingfei , Yin, Ping

Mayo Clinic

The FASEB Journal | June 21, 2021 | Volume: 22 | Issue: S1 | Pages: No page available

10.1096/fasebj.22.1_supplement.1210.3 Get It

The objective of this study was to identify signaling pathways leading to the development of interstitial fibrosis and tubular atrophy in the stenotic kidney and compensatory hypertrophy/hyperplasia of the contralateral kidney in a murine 2 kidney 1 clip model of hypertensive nephrosclerosis. Mice were studied 2, 5, and 11 weeks after undergoing surgery to establish unilateral renal artery stenosis (RAS). RAS animals, but not sham controls, became hypertensive within 1 week. Compensatory enlargement of the contralateral kidney was associated with a transient increase in proliferation (as assessed by PCNA and Mib‐1), p‐ERK, caspase 3, p27, p53, and TGF‐β expression at early time points, with return to baseline levels by 11 weeks. Tubular atrophy in the stenotic kidney was associated with a persistent increase in p‐ERK, Mib‐1, p53, p21, and p27 expression through 11 weeks. Proliferative activity was observed in tubular epithelial cells and in inflammatory cells. The atrophic kidneys had little apoptotic activity (caspase 3, TUNEL staining). The atrophic kidneys showed progressive increases in TGF‐β and α‐SMA expression and extracellular matrix deposition throughout 11 weeks. Interstitial inflammation was associated with increased MCP‐1 expression. Mechanisms underlying this differential response to unilateral RAS await definition.
Development of a Patient-Specific p.D85N-Potassium Voltage-Gated Channel Subfamily E Member 1–Induced Pluripotent Stem Cell–Derived Cardiomyocyte Model for Drug-Induced Long QT Syndrome
Ye, Dan , Kim, C.S. John, Zhou, Wei , Tester, David J. , Giudicessi, John R. , Ackerman, Michael J. , Kim, Maengjo

Mayo Clinic

Circulation: Genomic and Precision Medicine | May 18, 2021 | Volume: 14 | Issue: 3 | Pages: No page available

10.1161/circgen.120.003234 | PMID 34003017 Get It

Background: Prior epidemiological studies demonstrated that the p.D85N-Potassium voltage-gated channel subfamily E member 1 (KCNE1) common variant reduces repolarization reserve and predisposes to drug-induced QT prolongation/torsades de pointes. We sought to develop a cellular model for drug-induced long QT syndrome using a patient-specific induced pluripotent stem cell-derived cardiomyocyte (iPSC-CM). Methods: p.D85N-KCNE1 iPSCs were generated from a 23-year-old female with an exaggerated heart rate-corrected QT interval response to metoclopramide (ΔQTc of 160 ms). Clustered regularly interspaced short palindromic repeats-associated 9 technology was used to generate gene-corrected isogenic iPSCs. Field potential duration and action potential duration (APD) were measured from iPSC-CMs. Results: At baseline, p.D85N-KCNE1 iPSC-CMs displayed significantly longer field potential duration (281±15 ms, n=13 versus 223±8.6 ms, n=14, P <0.01) and action potential duration at 90% repolarization (APD90; 579±22 ms, n=24 versus 465±33 ms, n=26, P <0.01) than isogenic-control iPSC-CMs. Dofetilide at a concentration of 2 nM increased significantly field potential duration (379±20 ms, n=13, P <0.01) and APD90 (666±11 ms, n=46, P <0.01) in p.D85N-KCNE1 iPSC-CMs but not in isogenic-control. The effect of dofetilide on APD90 (616±54 ms, n=7 versus 526±54 ms, n=10, P <0.05) was confirmed by Patch-clamp. Interestingly, treatment of p.D85N-KCNE1 iPSC-CMs with estrogen at a concentration of 1 nM exaggerated further dofetilide-induced APD90 prolongation (696±9 ms, n=81, P <0.01) and caused more early afterdepolarizations (11.7%) compared with isogenic control (APD90: 618±8 ms, n=115 and early afterdepolarizations: 2.6%, P <0.05). Conclusions: This iPSC-CM study provides further evidence that the p.D85N-KCNE1 common variant in combination with environmental factors such as QT prolonging drugs and female sex is proarrhythmic.
Suppression-Replacement KCNQ1 Gene Therapy for Type 1 Long QT Syndrome
Dotzler, Steven M. , Kim, C.S. John, Gendron, William A.C. , Zhou, Wei , Ye, Dan , Bos, J. Martijn , Tester, David J. , Barry, Michael A. , Ackerman, Michael J. , Barry, Michael A , Bos, Johan M

Mayo Clinic

Circulation | January 28, 2021 | Volume: 143 | Issue: 14 | Pages: 1411-1425

10.1161/circulationaha.120.051836 | PMID 33504163 Get It

Background: Type 1 long QT syndrome (LQT1) is caused by loss-of-function variants in the KCNQ1 -encoded K v 7.1 potassium channel α-subunit that is essential for cardiac repolarization, providing the slow delayed rectifier current. No current therapies target the molecular cause of LQT1. Methods: A dual-component suppression-and-replacement (SupRep) KCNQ1 gene therapy was created by cloning a KCNQ1 short hairpin RNA and a short hairpin RNA-immune KCNQ1 cDNA modified with synonymous variants in the short hairpin RNA target site, into a single construct. The ability of KCNQ1-SupRep gene therapy to suppress and replace LQT1-causative variants in KCNQ1 was evaluated by means of heterologous expression in TSA201 cells. For a human in vitro cardiac model, induced pluripotent stem cell–derived cardiomyocytes (iPSC-CMs) were generated from 4 patients with LQT1 (KCNQ1-Y171X, -V254M, -I567S, and -A344A/spl) and an unrelated healthy control. CRISPR-Cas9 corrected isogenic control iPSC-CMs were made for 2 LQT1 lines (correction of KCNQ1-V254M and KCNQ1-A344A/spl). FluoVolt voltage dye was used to measure the cardiac action potential duration (APD) in iPSC-CMs treated with KCNQ1-SupRep. Results: In TSA201 cells, KCNQ1-SupRep achieved mutation-independent suppression of wild-type KCNQ1 and 3 LQT1-causative variants (KCNQ1-Y171X, -V254M, and -I567S) with simultaneous replacement of short hairpin RNA-immune KCNQ1 as measured by allele-specific quantitative reverse transcription polymerase chain reaction and Western blot. Using FluoVolt voltage dye to measure the cardiac APD in the 4 LQT1 patient-derived iPSC-CMs, treatment with KCNQ1-SupRep resulted in shortening of the pathologically prolonged APD at both 90% and 50% repolarization, resulting in APD values similar to those of the 2 isogenic controls. Conclusions: This study provides the first proof-of-principle gene therapy for complete correction of long QT syndrome. As a dual-component gene therapy vector, KCNQ1-SupRep successfully suppressed and replaced KCNQ1 to normal wild-type levels. In TSA201 cells, cotransfection of LQT1-causative variants and KCNQ1-SupRep caused mutation-independent suppression and replacement of KCNQ1 . In LQT1 iPSC-CMs, KCNQ1-SupRep gene therapy shortened the APD, thereby eliminating the pathognomonic feature of LQT1.
Deep‐learning‐based direct inversion for material decomposition
Gong, Hao , Tao, Shengzhen , Rajendran, Kishore , Zhou, Wei , McCollough, Cynthia H. , Leng, Shuai

Mayo Clinic

Medical Physics | October 6, 2020 | Volume: 47 | Issue: 12 | Pages: 6294-6309

10.1002/mp.14523 | PMID 33020942 Get It

PurposeTo develop a convolutional neural network (CNN) that can directly estimate material density distribution from multi‐energy computed tomography (CT) images without performing conventional material decomposition.MethodsThe proposed CNN (denoted as Incept‐net) followed the general framework of encoder–decoder network, with an assumption that local image information was sufficient for modeling the nonlinear physical process of multi‐energy CT. Incept‐net was implemented with a customized loss function, including an in‐house‐designed image‐gradient‐correlation (IGC) regularizer to improve edge preservation. The network consisted of two types of customized multibranch modules exploiting multiscale feature representation to improve the robustness over local image noise and artifacts. Inserts with various densities of different materials [hydroxyapatite (HA), iodine, a blood–iodine mixture, and fat] were scanned using a research photon‐counting detector (PCD) CT with two energy thresholds and multiple radiation dose levels. The network was trained using phantom image patches only, and tested with different‐configurations of full field‐of‐view phantom and in vivo porcine images. Furthermore, the nominal mass densities of insert materials were used as the labels in CNN training, which potentially provided an implicit mass conservation constraint. The Incept‐net performance was evaluated in terms of image noise, detail preservation, and quantitative accuracy. Its performance was also compared to common material decomposition algorithms including least‐square‐based material decomposition (LS‐MD), total‐variation regularized material decomposition (TV‐MD), and U‐net‐based method.ResultsIncept‐net improved accuracy of the predicted mass density of basis materials compared with the U‐net, TV‐MD, and LS‐MD: the mean absolute error (MAE) of iodine was 0.66, 1.0, 1.33, and 1.57 mgI/cc for Incept‐net, U‐net, TV‐MD, and LS‐MD, respectively, across all iodine‐present inserts (2.0–24.0 mgI/cc). With the LS‐MD as the baseline, Incept‐net and U‐net achieved comparable noise reduction (both around 95%), both higher than TV‐MD (85%). The proposed IGC regularizer effectively helped both Incept‐net and U‐net to reduce image artifact. Incept‐net closely conserved the total mass densities (i.e., mass conservation constraint) in porcine images, which heuristically validated the quantitative accuracy of its outputs in anatomical background. In general, Incept‐net performance was less dependent on radiation dose levels than the two conventional methods; with approximately 40% less parameters, the Incept‐net achieved relatively improved performance than the comparator U‐net, indicating that performance gain by Incept‐net was not achieved by simply increasing network learning capacity.ConclusionIncept‐net demonstrated superior qualitative image appearance, quantitative accuracy, and lower noise than the conventional methods and less sensitive to dose change. Incept‐net generalized and performed well with unseen image structures and different material mass densities. This study provided preliminary evidence that the proposed CNN may be used to improve the material decomposition quality in multi‐energy CT.
Genetic Architecture of Abdominal Aortic Aneurysm in the Million Veteran Program
Klarin, Derek , Judy, Renae , Dikilitas, Ozan , Wolford, Brooke N. , Paranjpe, Ishan , Levin, Michael G. , Pan, Cuiping , Tcheandjieu, Catherine , Spin, Joshua M. , Assimes, Themistocles L. , Nyrønning, Linn Åldstedt , Mattsson, Erney , Denny, Joshua C. , Zhang, Yanfei , Jarvik, Gail P. , Gharavi, Ali G. , Harley, John B. , Mentch, Frank , Håkonarson, Håkon , Skogholt, Anne Heidi , Thomas, Laurent F. , Gabrielsen, Maiken E. , Zhou, Wei , Fritsche, Lars G. , Huang, Jie , Natarajan, Pradeep , Sun, Yan V. , DuVall, Scott L. , Cho, Kelly , Chang, Kyong‐Mi , Wilson, Peter W.F. , O’Donnell, Christopher J., Kathiresan, Sekar , Scali, Salvatore T. , Jones, Gregory T. , Bown, Matthew J. , Nadkarni, Girish N. , Ritchie, Marylyn D. , Tsao, Philip S. , Gaziano, J. Michael , Ramoni, Rachel , Breeling, Jim, Huang, Grant D. , Muralidhar, Sumitra , O’Donnell, Christopher J. , Romero, Jonathan , Tsao, Philip S., Moser, Jennifer , Whitbourne, Stacey B. , Brewer, Jessica V., Warren, Stuart, Argyres, Dean P., Tsao, Philip S., Stephens, Brady, Brophy, Mary T. , Humphries, Donald E., Shayan, Shahpoor, O’Donnell, Christopher J., Pyarajan, Saiju , Tsao, Philip S., Dell’Italia, Louis J. , Zablocki, Clement J., Beckham, Jean, Wells, John A. , Gutierrez, Salvador, Kaminsky, Laurence S., Villareal, Gerardo, Xu, Junzhe, Hamner, Mark B. , Haddock, Kathlyn Sue, Bhushan, Sujata, Iruvanti, Pran, Godschalk, Michael, Buford, Malcolm, Mastorides, Stephen , Ratcliffe, Nora, Flórez, Hermes , Swann, Alan C. , Murdoch, Maureen, Yeh, Shing Shing, Washburn, Ronald G., Jhala, Darshana , Aguayo, Samuel M., Cohen, David , Sharma, Satish, Callaghan, John, Oursler, Kris Ann, Ahuja, Sunil K. , Gutierrez, Amparo, Schifman, Ronald, Greco, Jennifer , Oehlert, Mary E. , Wallbom, Agnes, Fernando, Ronald, Morgan, Timothy R. , Stapley, Todd, Anderson, Gwenevere, Sonel, Elif, Fayad, Joseph, Hung, Adriana M. , Lichy, Jack, Hurley, Robin A. , Hakonarson, Hakon , Denny, Joshua C , Jarvik, Gail P , Dikilitas, Ozan , Assimes, Themistocles L , Natarajan, Pradeep , Wolford, Brooke N , Scali, Salvatore , Chang, Kyong-Mi , Tsao, Philip S , Verma, Shefali S. , Lynch, Julie A. , Edwards, Todd L. , Larson, Eric B. , Lee, Ming Ta Michael , Carrell, David , Pacheco, Jennifer A. , Hveem, Kristian , Nielsen, Jonas Bille , Rader, Daniel J , O’Donnell, Christopher J., Berceli, Scott A. , Willer, Cristen J , Kullo, Iftikhar J. , Damrauer, Scott M , Beckham, Jean C , Tsao, Philip S., Concato, John , Tsao, Philip S., Do, Nhan , Nguyen, Xuan‐Mai T. , O’Donnell, Christopher J., Tsao, Philip S., Hauser, Elizabeth R. , Zhao, Hongyu , McArdle, Rachel , Whittle, Jeff , Beckham, Jean, Wells, John, Gibson, Gretchen , Kinlay, Scott , Ballas, Zuhair K. , Klein, Jon , Sriram, Peruvemba , Washburn, Ronald, Whooley, Mary A. , Rauchman, Michael I. , Servatius, Richard J. , Sherman, Scott E. , Boyko, Edward J. , Meyer, Laurence , Gupta, Samir , Robey, R. Brooks , Striker, Rob

Mayo Clinic

Circulation | September 28, 2020 | Volume: 142 | Issue: 17 | Pages: 1633-1646

10.1161/circulationaha.120.047544 | PMID 32981348 Get It

Background: Abdominal aortic aneurysm (AAA) is an important cause of cardiovascular mortality; however, its genetic determinants remain incompletely defined. In total, 10 previously identified risk loci explain a small fraction of AAA heritability. Methods: We performed a genome-wide association study in the Million Veteran Program testing ≈18 million DNA sequence variants with AAA (7642 cases and 172 172 controls) in veterans of European ancestry with independent replication in up to 4972 cases and 99 858 controls. We then used mendelian randomization to examine the causal effects of blood pressure on AAA. We examined the association of AAA risk variants with aneurysms in the lower extremity, cerebral, and iliac arterial beds, and derived a genome-wide polygenic risk score (PRS) to identify a subset of the population at greater risk for disease. Results: Through a genome-wide association study, we identified 14 novel loci, bringing the total number of known significant AAA loci to 24. In our mendelian randomization analysis, we demonstrate that a genetic increase of 10 mm Hg in diastolic blood pressure (odds ratio, 1.43 [95% CI, 1.24–1.66]; P =1.6×10 −6 ), as opposed to systolic blood pressure (odds ratio, 1.06 [95% CI, 0.97–1.15]; P =0.2), likely has a causal relationship with AAA development. We observed that 19 of 24 AAA risk variants associate with aneurysms in at least 1 other vascular territory. A 29-variant PRS was strongly associated with AAA (odds ratio PRS , 1.26 [95% CI, 1.18–1.36]; P PRS =2.7×10 −11 per SD increase in PRS), independent of family history and smoking risk factors (odds ratio PRS+family history+smoking , 1.24 [95% CI, 1.14–1.35]; P PRS =1.27×10 −6 ). Using this PRS, we identified a subset of the population with AAA prevalence greater than that observed in screening trials informing current guidelines. Conclusions: We identify novel AAA genetic associations with therapeutic implications and identify a subset of the population at significantly increased genetic risk of AAA independent of family history. Our data suggest that extending current screening guidelines to include testing to identify those with high polygenic AAA risk, once the cost of genotyping becomes comparable with that of screening ultrasound, would significantly increase the yield of current screening at reasonable cost.
Systematic optimization of ultrasound grayscale imaging presets and its application in abdominal scanning
Long, Zaiyang , Tradup, Donald J., Stekel, Scott F. , Callstrom, Matthew R. , Hangiandreou, Nicholas J., Zhou, Wei , Zhou, Wei

Mayo Clinic

Journal of Applied Clinical Medical Physics | August 12, 2020 | Volume: 21 | Issue: 10 | Pages: 192-199

10.1002/acm2.13000 | PMID 32779836 Get It

AbstractPurposeUltrasound grayscale imaging preset optimization has often been qualitative and dependent upon vendor application specialists. This study aimed to propose a systematic approach for grayscale imaging preset optimization and apply the approach in a clinical abdominal scan setting.MethodsA six‐step approach was detailed including identification of clinical task, adjustment of basic parameters, fine‐tuning of advanced parameters, image performance metrics confirmation, clinical evaluation and data analysis, and implementation of new presets and monitoring of clinical usage. Its application in an abdominal scanning task was described for each step with phantoms, volunteers, and software tools.ResultsClinical image data analytics facilitated the understanding of the imaging task, relevant transducers, and target characteristics, in addition to specific requests from radiologists. Quantitative measurements were made on global image contrast and gray map function. In addition, clinically relevant phantoms and volunteer scans without and with acoustic distortion layers were involved to determine the new presets. Furthermore, phantom signal to noise ratio study and clinical evaluation using volunteers with different body habitus were utilized to confirm the superiority of the new presets. Quantitative clinical usage monitoring demonstrated successful implementation of the new presets.ConclusionsA systematic approach for grayscale imaging preset optimization has been proposed and successfully applied for a specific clinical task. This approach was designed to be generalizable and relatively flexible, which would facilitate movement away from previous qualitative and subjective approaches.
Prevalence and electrophysiological phenotype of rare SCN5A genetic variants identified in unexplained sudden cardiac arrest survivors
Giudicessi, John R. , Ye, Dan , Stutzman, Marissa J., Zhou, Wei , Tester, David J. , Ackerman, Michael J.

Mayo Clinic

EP Europace | February 14, 2020 | Volume: 22 | Issue: 4 | Pages: 622-631

10.1093/europace/euz337 | PMID 32091595 Get It

Abstract Aims To determine the prevalence and in vitro electrophysiological (EP) phenotype of ultra-rare SCN5A variants of uncertain significance (VUS) identified in unexplained sudden cardiac arrest (SCA) survivors. Methods and results Retrospective review of 73 unexplained SCA survivors was used to identify all patients that underwent a form of genetic testing that included comprehensive SCN5A analysis. Ultra-rare SCN5A variants (minor allele frequency &lt; 0.005) were adjudicated according to the 2015 American College of Medical Genetics and Genomics (ACMG) guidelines. Variants designated as VUS were expressed heterologously and characterized using the whole-cell patch clamp technique. Overall, 60/73 (82%; the average age at SCA 28 ± 12 years) unexplained SCA survivors had received SCN5A genetic testing. Of these, 5/60 (8.3%) had an ultra-rare SCN5A variant. All SCN5A variants were classified as VUS. Whereas the single SCN5A VUS (p.Asp872Asn-SCN5A) identified in an unexplained SCA survivor with PR interval prolongation and inferior early repolarization conferred a loss-of-function phenotype (46.2% reduction in peak current density; 16 ms slower recovery from inactivation), the four other SCN5A VUS (p.Glu30Gly-SCN5A, p.Gln245Lys-SCN5A, p.Pro648Leu-SCN5A, and p.Glu1240Gln-SCN5A) identified in unexplained SCA survivors without early repolarization/conduction delay were indistinguishable from wild-type Nav1.5 channels. Conclusion In the absence of a phenotype(s) potentially attributable to sodium channel dysfunction, all SCN5A VUS identified in unexplained SCA survivors conferred a wild-type EP phenotype in vitro. As the background rate of SCN5A genetic variation is not trivial, great care must be taken to avoid prioritizing genotype over phenotype when attempting to ascertain the root cause of an individual's SCA.
Dose Reduction for Sinus and Temporal Bone Imaging Using Photon-Counting Detector CT With an Additional Tin Filter
Voß, Benjamin, Tao, Shengzhen , Lane, John I. , Weaver, Jayse , Carlson, Matthew L. , Rajendran, Kishore , Zhou, Wei , DeLone, David R. , Fletcher, Joel G. , McCollough, Cynthia H. , Leng, Shuai

Mayo Clinic

Investigative Radiology | November 26, 2019 | Volume: 55 | Issue: 2 | Pages: 91-100

10.1097/rli.0000000000000614 | PMID 31770297 Get It

Objective The aim of this study was to quantitatively demonstrate radiation dose reduction for sinus and temporal bone examinations using high-resolution photon-counting detector (PCD) computed tomography (CT) with an additional tin (Sn) filter. Materials and Methods A multienergy CT phantom, an anthropomorphic head phantom, and a cadaver head were scanned on a research PCD-CT scanner using ultra-high-resolution mode at 100-kV tube potential with an additional tin filter (Sn-100 kV) and volume CT dose index of 10 mGy. They were also scanned on a commercial CT scanner with an energy-integrating detector (EID) following standard clinical protocols. Thirty patients referred to clinically indicated sinus examinations, and two patients referred to temporal bone examinations were scanned on the PCD-CT system after their clinical scans on an EID-CT. For the sinus cohort, PCD-CT scans were performed using Sn-100 kV at 4 dose levels at 10 mGy (n = 9), 8 mGy (n = 7), 7 mGy (n = 7), and 6 mGy (n = 7), and the clinical EID-CT was performed at 120 kV and 13.7 mGy (mean CT volume dose index). For the temporal bone scans, PCD-CT was performed using Sn-100 kV (10.1 mGy), and EID-CT was performed at 120 kV and routine clinical dose (52.6 and 66 mGy). For both PCD-CT and EID-CT, sinus images were reconstructed using H70 kernel at 0.75-mm slice thickness, and temporal bone images were reconstructed using a U70 kernel at 0.6-mm slice thickness. In addition, iterative reconstruction with a dedicated sharp kernel (V80) was used to obtain high-resolution PCD-CT images from a sinus patient scan to demonstrate improved anatomic delineation. Improvements in spatial resolution from the dedicated sharp kernel was quantified using modulation transfer function measured with a wire phantom. A neuroradiologist assessed the H70 sinus images for visualization of critical anatomical structures in low-dose PCD-CT images and routine-dose EID-CT images using a 5-point Likert scale (structural detection obscured and poor diagnostic confidence, score = 1; improved anatomic delineation and diagnostic confidence, score = 5). Image contrast and noise were measured in representative regions of interest and compared between PCD-CT and EID-CT, and the noise difference between the 2 acquisitions was used to estimate the dose reduction in the sinus and temporal bone patient cohorts. Results The multienergy phantom experiment showed a noise reduction of 26% in the Sn-100 kV PCD-CT image, corresponding to a total dose reduction of 56% compared with EID-CT (clinical dose) without compromising image contrast. The PCD-CT images from the head phantom and the cadaver scans demonstrated a dose reduction of 67% and 83%, for sinus and temporal bone examinations, respectively, compared with EID-CT. In the sinus cohort, PCD-CT demonstrated a mean dose reduction of 67%. The 10- and 8-mGy sinus patient images from PCD-CT were significantly superior to clinical EID-CT for visualization of critical sinus structures (median score = 5 ± 0.82 and P = 0.01 for lesser palatine foramina, median score = 4 ± 0.68 and P = 0.039 for nasomaxillary sutures, and median score = 4 ± 0.96 and P = 0.01 for anterior ethmoid artery canal). The 6- and 7-mGy sinus patient images did not show any significant difference between PCD-CT and EID-CT. In addition, V80 (sharp kernel, 10% modulation transfer function = 18.6 cm −1 ) PCD-CT images from a sinus patient scan increased the conspicuity of nasomaxillary sutures compared with the clinical EID-CT images. The temporal bone patient images demonstrated a dose reduction of up to 85% compared with clinical EID-CT images, whereas visualization of inner ear structures such as the incudomalleolar joint were similar between EID-CT and PCD-CT. Conclusions Phantom and cadaver studies demonstrated dose reduction using Sn-100 kV PCD-CT compared with current clinical EID-CT while maintaining the desired image contrast. Dose reduction was further validated in sinus and temporal bone patient studies. The ultra-high resolution capability from PCD-CT allowed improved anatomical delineation for sinus imaging compared with current clinical standard.
Determination of iodine detectability in different types of multiple-energy images for a photon-counting detector computed tomography system
Michalak, Gregory J. , Weaver, Jayse , Ferrero, Andrea , Gong, Hao , Fetterly, Kenneth A. , Zhou, Wei , McCollough, Cynthia H , Leng, Shuai , Zhou, Wei , McCollough, Cynthia H. , Leng, Shuai

Mayo Clinic

Journal of Medical Imaging | October 15, 2019 | Volume: 6 | Issue: 04 | Pages: 1

10.1117/1.jmi.6.4.043501 | PMID 31620546 Get It

Evaluation of Shimming Techniques on MRI Breast Image Quality at 1.5T
Favazza, Christopher , Axmacher, Jessica A, Trzasko, Joshua D. , Lee, Christine U. , Zhou, Wei , Favazza, Christopher P, Zhou, Wei , Geske, Jennifer R.

Mayo Clinic

Journal of Breast Imaging | August 23, 2019 | Volume: 1 | Issue: 3 | Pages: 199-204

10.1093/jbi/wbz045 | PMID 38424766 Get It

Abstract Objective The quality of all clinical MRI is dependent on B0 homogeneity, which is optimized during the shimming part of a prescan or preparatory phase before image acquisition. The purpose of this study was to assess shimming techniques clinically employed for breast MRI across our practice, and to determine factors that correlate with higher image quality for contrast-enhanced breast MRI at 1.5T. Methods One hundred consecutive female patients were retrospectively collected with Institutional Review Board approval. Shimming-related parameters, including shim-box placement and shimming gradient offsets were extracted from prior contrast-enhanced 3D fat-suppressed T1-weighted gradient echo image acquisitions. Three breast radiologists evaluated these images for fat saturation, breast density, overall image quality, and artifacts. Technologist experience was also evaluated for variability of shimming. Generalized linear mixed models were used to compare acquisition parameters between fat saturation. P &lt; 0.05 was considered as statistical significance. Results The percentage of soft tissue inside the field of view (FOV) (ie, Tissue/FOV) in the good fat-saturation group (0.37 ± 0.06) was significantly lower (P &lt; 0.01) than that in the poor fat-saturation group (0.39 ± 0.06). Other shimming-related parameters were found not significantly affecting the fat-saturation outcomes. Technologists with more experience tended to have less variable shimming performance than junior technologists did. Conclusions The quality of clinical MRI and especially breast MRI is highly dependent on shimming. Decreasing Tissue/FOV was associated with good image quality (good fat saturation). Optimization of shimming may require manual shimming or higher-order field-correction strategies.