Citations

Clear

68 citation(s) found for "Zhang, Xiaoming".

Ultrasound Vibroelastography for Evaluation of Secondary Extremity Lymphedema
Bustos, Samyd S. , Zhou, Boran , Huang, Tony Chieh‐Ting , Shao, Juntao , Ciudad, Pedro , Forte, Antonio J. , Zhang, Xiaoming , Manrique, Oscar J. , Forte, Antonio Jorge , Bustos, S S , Zhang, Xiaoming

Mayo Clinic

Annals of Plastic Surgery | June 10, 2020 | Volume: 85 | Issue: S1 | Pages: S92-S96

10.1097/sap.0000000000002448 | PMID 32530852 Get It

Background Lymphedema treatment is an ongoing challenge. It impacts quality of life due to pain, loss of range of motion of the extremity, and repeated episodes of cellulitis. Different modalities have been used to evaluate lymphedema; some are more error-prone and some are more invasive. However, these measurements are poorly standardized, and intrarater and interrater reliabilities are difficult to achieve. This pilot study aims to assess the feasibility of ultrasound vibroelastography for assessing patients with extremity lymphedema via measuring shear wave speeds of subcutaneous tissues. Methods Patients with clinical and lymphoscintigraphic diagnosis of secondary lymphedema in the extremities without prior surgical treatment were included. A 0.1-s harmonic vibration was generated at three frequencies (100, 150, and 200 Hz) by the indenter of a handheld shaker on the skin. An ultrasound probe was used for noninvasively capturing of wave propagation in the subcutaneous tissue. Wave speeds were measured in the subcutaneous tissues of both the control and affected extremities. Results A total of 11 female patients with secondary lymphedema in the extremities were enrolled in this study. The magnitudes of the wave speeds of the region of interest in the subcutaneous tissue at lymphedema sites in the upper extremity (3.9 ± 0.17 m/s, 5.96 ± 0.67 m/s, and 7.41 ± 1.09 m/s) were statistically higher than those of the control sites (2.1 ± 0.27 m/s, 2.93 ± 0.57 m/s, and 3.56 ± 0.76 m/s) at 100, 150, and 200 Hz (P < 0.05), and at 100 and 200 Hz (P < 0.05) between lymphedema (4.33 ± 0.35 m/s, 4.17 ± 1.00 m/s, and 4.56 ± 0.37 m/s) and controls sites (2.48 ± 0.43 m/s, 2.77 ± 0.55 m/s, and 3.06 ± 0.29 m/s) in the lower extremity. Conclusions These preliminary data suggest that ultrasound vibroelastography may be useful in the evaluation of secondary lymphedema and can be a valuable tool to noninvasively track treatment progress.
Quantification of lung surface wave speed in a water-filled lung: An ex vivo swine lung study
Zhang, Alex X. , Zhang, Xiaoming , Zhou, Boran

Mayo Clinic

The Journal of the Acoustical Society of America | November 14, 2019 | Volume: 146 | Issue: 4_Supplement | Pages: 3070-3070

10.1121/1.5137653 Get It

Lung edema is a common symptom of congestive heart failure and inflammatory conditions, such as acute respiratory distress syndrome. Currently, computed tomography (CT) is considered the standard to assess lung edema, but it requires ionizing radiation and poses a significant logistic burden. Lung ultrasound (LUS) has previously been used to assess lung edema using ultrasound B-line artifacts, but analysis of the B-line artifacts relies on visual interpretation. We developed lung ultrasound surface wave elastography (LUSWE) to measure lung surface wave speed safely. This project aims to evaluate LUSWE to quantify lung surface wave speed in an ex vivo water-filled swine lung. The lung surface wave speeds were measured at baseline and at frequencies of 100 Hz, 200 Hz, 300 Hz, and 400 Hz. Then, an amount of water was filled into the lung through its trachea. Ultrasound imaging was used to guide the water filling until significant changes were visible on the imaging. The lung surface wave speeds were measured. An additional 120 ml of water was then filled into the lung. The lung surface wave speeds were measured again. The results demonstrated that the lung surface wave speed decreased with respect to water content.
Ultrasound surface wave elastography for assessing extremity lymphedema: A pilot clinical study
Bustos, Samyd S. , Huang, Tony Chieh‐Ting , Shao, Juntao , Manrique, Oscar J. , Zhang, Xiaoming , Bustos, S S , Zhou, Boran

Mayo Clinic

The Journal of the Acoustical Society of America | November 13, 2019 | Volume: 146 | Issue: 4_Supplement | Pages: 2865-2865

10.1121/1.5136942 Get It

Lymphedema is a condition in which protein-rich fluid accumulates in the tissue causing impaired limb function from swelling and stiffness. Understanding the mechanical properties of soft tissue in lymphedematous limbs is important in clinical diagnosis. We recently developed an ultrasound surface wave elastography (USWE) technique for measuring the shear wave speed of tissue. The aim of this study is to evaluate lymphedematous limb use USWE. A total of 11 patients with lymphedema were included. Both normal and affected extremities were measured. A 0.1-s harmonic vibration was generated by the indenter of the handheld shaker on the limb. Ultrasound probe was used for detecting the tissue motion. Shear wave speed of the tissue was measured using 2-D processing window technique. A region of interest was selected to measure superficial and deep fat tissues. The obtained results showed that the magnitudes of the wave speeds of both the superficial and deep fat tissue at lymphedema sites were statistically higher than those of the control sites, respectively. This suggests that USWE may be useful in assessing correlation between tissue stiffness and lymphedema and would enable physicians to monitor disease severity.
A Pilot Study of Wet Lung Using Lung Ultrasound Surface Wave Elastography in an Ex Vivo Swine Lung Model
Zhang, Alex X. , Zhou, Boran , Zhang, Xiaoming

Mayo Clinic

Applied Sciences | September 19, 2019 | Volume: 9 | Issue: 18 | Pages: 3923

10.3390/app9183923 | PMID 36016765 Get It

Extravascular lung water (EVLW) is a basic symptom of congestive heart failure and other conditions. Computed tomography (CT) is standard method used to assess EVLW, but it requires ionizing radiation and radiology facilities. Lung ultrasound reverberation artifacts called B-lines have been used to assess EVLW. However, analysis of B-line artifacts depends on expert interpretation and is subjective. Lung ultrasound surface wave elastography (LUSWE) was developed to measure lung surface wave speed. This pilot study aimed at measureing lung surface wave speed due to lung water in an ex vivo swine lung model. The surface wave speeds of a fresh ex vivo swine lung were measured at 100 Hz, 200 Hz, 300 Hz, and 400 Hz. An amount of water was then filled into the lung through its trachea. Ultrasound imaging was used to guide the water filling until significant changes were visible on the imaging. The lung surface wave speeds were measured again. It was found that the lung surface wave speed increases with frequency and decreases with water volume. These findings are confirmed by experimental results on an additional ex vivo swine lung sample.
Evaluation of posterior sclera viscoelasticity in eyes with papilledema by using ultrasound vibro-elastography
Kazemi, Arash , Chen, John J. , Zhou, Boran , Sit, Arthur J. , Zhang, Xiaoming

Mayo Clinic

The Journal of the Acoustical Society of America | April 24, 2019 | Volume: 145 | Issue: 3_Supplement | Pages: 1675-1675

10.1121/1.5101145 Get It

Papilledema is optic nerve swelling caused by increased intracranial pressure, which has the potential to cause significant vision loss. Papilledema is typically bilateral and symmetric but can sometimes be asymmetric and even unilateral. The cause for this asymmetry is unknown. The purpose of this study was to utilize ultrasound vibro-elastography (UVE) to assess for biomechanical differences in eyes with papilledema. Nine patients with papilledema and 9 age-matched controls were enrolled. An external harmonic vibration was used to generate wave propagation through the eyelid with three excitation frequencies of 100, 150, and 200 Hz. A 6.4 MHz ultrasound probe was used to noninvasively measure the wave propagation in the posterior sclera to provide shear wave speeds and viscoelasticity (fit with Voigt model). The magnitudes of the shear wave speed and viscoelasticity of the idiopathic intracranial hypertension patients’ posterior sclera were significantly higher than those of healthy subjects. Moreover, for patients with unilateral papilledema, the magnitudes of wave speed and viscoelasticity of the posterior sclera were statistically higher in eyes with papilledema than in the contralateral eyes without papilledema. UVE provides a noninvasive technique to measure the viscoelastic properties of the posterior sclera, which is stiffer in eyes with papilledema.
Lung ultrasound surface wave elastography for assessing interstitial lung disease
Zhou, Jinling , Osborn, Thomas G. , Kalra, Sanjay , Zhang, Xiaoming , Zhou, Boran , Bartholmai, Brian J.

Mayo Clinic

The Journal of the Acoustical Society of America | April 24, 2019 | Volume: 145 | Issue: 3_Supplement | Pages: 1673-1673

10.1121/1.5101138 Get It

Many lung diseases including interstitial lung disease (ILD) are associated with changes in the lung’s biomechanical properties. ILD comprises a number of serious diseases in which fibrosis stiffens and damages lung tissue. Most ILDs are typically distributed in the lung’s peripheral and subpleural regions. Pulmonary function test (PFT) and high-resolution computed tomography (HRCT) are used to assess ILD. Ultrasonography is not widely used for lung assessment because ultrasound cannot image deep lung tissue. We have developed lung ultrasound surface wave elastography (LUSWE) for measuring superficial lung wave speed. In LUSWE, a 0.1-s harmonic vibration is generated on the chest wall of a subject using a handheld vibrator. An ultrasound probe is aligned with the vibration excitation in the same intercostal space to measure the generated surface wave propagation on the lung. A human subject is examined in a sitting position. The lung is tested at the total lung volume and through six intercostal spaces. Significant differences of surface wave speed between patients and controls were found in 6 lung regions and for 3 excitation frequencies. A positive correlation between LUSWE and clinical tests including HRCT and PTF was found. LUSWE may complement the clinical standard HRCT for assessing ILD.
Application of lung ultrasound surface wave elastography for assessment of extravascular lung water in patients hospitalized with congestive heart failure
Zhou, Jinling , Küçük, Hi̇lal Olgun , Wiley, Brandon M. , Zhou, Boran , Pandompatam, Govind , Zhang, Xiaoming

Mayo Clinic

The Journal of the Acoustical Society of America | April 24, 2019 | Volume: 145 | Issue: 3_Supplement | Pages: 1673-1674

10.1121/1.5101139 Get It

Lung ultrasound (LUS) detects the presence of extravascular lung water (EVLW) through the visualization of B-Line artifacts. However, the qualitative nature of LUS limits its effectiveness in serial or longitudinal studies such as evaluating changes in EVLW at different time points in patients undergoing diuretic therapy for congestive heart failure. Lung ultrasound surface wave elastography (LUSWE) is a novel technique using a small handheld device that can measure superficial lung tissue elastic properties. We aimed to evaluate the use of LUSWE to measure quantitative changes in lung elasticity caused by acute changes in EVLW. We performed LUSWE on consecutive days in 14 patients hospitalized for acute congestive heart failure with evidence of pulmonary edema (clinical EVLW). From day#1 to day#2, the patients had an average diuresis of net negative 2.1 l associated with an average decrease in 13 B-Lines by lung ultrasound, signifying a reduction in EVLW. LUSWE analysis demonstrated a significant reduction (p &lt; 0.05) in surface wave velocity in all interrogated intercostal spaces from day#1 to day#2. In summary, LUSWE performed at the bedside was able to demonstrate improvement in lung compliance (decreased elasticity) correlating with a reduction in EVLW in hospitalized patients being treated for congestive heart failure.
Comparison of ocular biomechanical properties in normal and glaucomatous eyes using ultrasound surface wave elastography
Kazemi, Arash , Sit, Arthur J. , Zhou, Boran , Zhang, Xiaoming

Mayo Clinic

The Journal of the Acoustical Society of America | April 24, 2019 | Volume: 145 | Issue: 3_Supplement | Pages: 1675-1675

10.1121/1.5101144 Get It

Biomechanical properties of the eye are important in understanding glaucoma. However, specific tissues that may be affected are unclear. In this study, we compared glaucomatous and normal eyes for differences in corneal tissue elasticity (as indicated by wave speed) and global ocular rigidity. Both eyes of 10 glaucoma patients and 10 normal controls, matched for age and intraocular pressure (IOP), were included. The ocular rigidity coefficient was calculated from supine IOP measured with and without a 10 g weight added to the tonometer. The wave speed in the cornea was measured by ultrasound surface wave elastography. With this technique, a spherical-tipped probe (4 mm diameter) was placed on the closed eyelid and vibrated at 100 Hz for 0.1 s. The wave speed was calculated using the phase gradient method. Measurements for normal and glaucoma eyes were compared using generalized estimating equation models. The corneal wave speed was similar between normal and glaucomatous eyes (P = 0.4). However, ocular rigidity was significantly lower in glaucomatous eyes (P &lt; 0.001) compared with normal eyes. There was no difference in age or IOP (P &gt; 0.3). Lower ocular rigidity in glaucomatous eyes suggests that a more compliant ocular shell may predispose to glaucoma. However, the lack of difference in the corneal wave speed suggests that corneal tissue is not significantly affected, and changes likely involve the sclera.
An ultrasound surface wave elastography technique for non-invasive measurement of scar tissue
Wyles, Saranya P. , Meves, Alexander , Moran, Steven L. , Zhou, Boran , Zhang, Xiaoming

Mayo Clinic

The Journal of the Acoustical Society of America | April 24, 2019 | Volume: 145 | Issue: 3_Supplement | Pages: 1676-1676

10.1121/1.5101147 Get It

Hypertrophic scars and keloids are characterized by excessive fibrosis and can be functionally problematic. Indeed, hypertrophic scarring is characterized by wide, raised scars that remain within the original borders of injury and have a rapid growth phase. There is a need for quantitative scar measurement modalities to effectively evaluate and monitor treatments. We aim to assess the role of the non-invasive scar-measuring device, ultrasound surface wave elastography (USWE), in accurately evaluating scar metrics. Two sites of breast tissue were tested control and scar portions. In USWE, a small, local, and 0.1-s harmonic vibration at three excitation frequencies (100, 150, and 200 Hz) was generated on these sites, and the resulting surface wave speed was measured via an ultrasound probe with a central frequency of 6.4 MHz. There was a statistically significant difference in the wave speed at three frequencies of the scar portion between prior and after treatment, suggesting that the scar portion was softener after treatment. USWE provides an objective assessment of the reaction of the scar to injury and treatment response.
Lung US Surface Wave Elastography in Interstitial Lung Disease Staging
Zhou, Boran , Bartholmai, Brian J. , Kalra, Sanjay , Osborn, Thomas G. , Zhang, Xiaoming , Zhang, Xiaoming , Bartholmai, Brian J

Mayo Clinic

Radiology | March 5, 2019 | Volume: 291 | Issue: 2 | Pages: 479-484

10.1148/radiol.2019181729 | PMID 30835191 Get It