Citations

Clear

46 citation(s) found for "Williamson, Eric".

The feasibility of low iodine dynamic CT angiography with test bolus for evaluation of lower extremity peripheral artery disease
Inoue, Akitoshi , Vrtiska, Terri J., Lee, Yong S. , Vasconcelos, Rogerio N., Weber, Nikkole M. , Halaweish, Ahmed F., Duba, Irene , Williamson, Eric E. , Fletcher, Joel G , Inoue, Akitoshi , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G.

Mayo Clinic

Vascular | January 18, 2021 | Volume: 29 | Issue: 6 | Pages: 927-937

10.1177/1708538120986304 | PMID 33459205 Get It

Objective This study aims to determine if low iodine dynamic computed tomography angiography performed after a fixed delay or test bolus acquisition demonstrates high concordance with clinical computed tomography angiography (using a routine amount of iodinated contrast) to display lower extremity peripheral arterial disease. Methods After informed consent, low iodine dynamic computed tomography angiography examination (using either a fixed delay or test bolus) using 50 ml of iodine contrast media was performed. A subsequent clinical computed tomography angiography using standard iodine dose (115 or 145 ml) served as the reference standard. A vascular radiologist reviewed dynamic and clinical computed tomography angiography images to categorize the lumen into “not opacified”, “<50% stenosis”, “ 50 ̶70% stenosis”, “>70% stenosis”, and “occluded” for seven arterial segments in each lower extremity. Concordance between low iodine dynamic computed tomography angiography and the routine iodine reference standard was calculated. The clinical utility of 4D volume-rendered images was also evaluated. Results Sixty-eight patients (average age 66.1 ± 12.3 years, male; female = 49: 19) were enrolled, with 34 patients each undergoing low iodine dynamic computed tomography angiography using fixed delay and test bolus techniques, respectively. One patient assigned to the test bolus group did not undergo low iodine computed tomography angiography due to unavailable delayed time. The fixed delay was 13 s, with test bolus acquisition resulting in a mean variable delay prior to image acquisition of 19.5 s (range; 8–32 s). Run-off to the ankle was observed using low iodine dynamic computed tomography angiography following fixed delay and test bolus acquisition in 76.4% (26/34) and 100% (33/33) of patients, respectively ( p = 0.005). Considering extremities with run-off to the ankle and without severe artifact, the concordance rate between low iodine dynamic computed tomography angiography and the routine iodine reference standard was 86.8% (310/357) using fixed delay and 97.9% (425/434) using test bolus ( p < 0.001). 4D volume-rendered images using fixed delay and test bolus demonstrated asymmetric flow in 57.7% (15/26) and 58.1% (18/31) ( p = 0.978) of patients, and collateral blood flow in 11.5% (3/26) and 22.6% (7/31) of patients ( p = 0.319), respectively. Conclusion Low iodine dynamic computed tomography angiography with test bolus acquisition has a high concordance with routine peripheral computed tomography angiography performed with standard iodine dose, resulting in improved run-off to the ankle compared to dynamic computed tomography angiography performed after a fixed delay. This method is useful for minimizing iodine dose in patients at risk for contrast-induced nephropathy. 4D volume-rendered computed tomography angiography images provide useful dynamic information.
Technical Note: kV‐independent coronary calcium scoring: A phantom evaluation of score accuracy and potential radiation dose reduction
Tao, Shengzhen , Sheedy, Emily N., Bruesewitz, Michael R. , Weber, Nikkole M. , Williams, Kyle , Halaweish, Ahmed F., Schmidt, Bernhard , Williamson, Eric E. , McCollough, C, Sheedy, Emily, Bruesewitz, Michael, Weber, Nikkole, McCollough, Cynthia, Leng, Shuai

Mayo Clinic

Medical Physics | December 18, 2020 | Volume: 48 | Issue: 3 | Pages: 1307-1314

10.1002/mp.14663 | PMID 33332626 Get It

Purpose To determine the accuracy of CT number and calcium score of a kV‐independent technique based on an artificial 120 kV reconstruction, and its potential to reduce radiation dose. Methods Anthropomorphic chest phantoms were scanned on a third‐generation dual‐source CT system equipped with the artificial 120 kV reconstruction. First, a phantom module containing a 20‐mm diameter hydroxyapatite (HA) insert was scanned inside the chest phantoms at different tube potentials (70–140 kV) to evaluate calcium CT number accuracy. Next, three small HA inserts (diameter/length = 5 mm) were inserted into a pork steak and scanned inside the phantoms to evaluate calcium score accuracy at different kVs. Finally, the same setup was scanned using automatic exposure control (AEC) at 120 kV, and then with automatic kV selection (auto‐kV). Phantoms were also scanned at 120 kV using a size‐dependent mA chart. CT numbers of soft tissue and calcium were measured from different kV images. Calcium score of each small HA insert was measured using commercial software. Results The CT number difference from 120 kV was small with tube potentials from 90 to 140 kV for both soft tissue and calcium (maximal difference of 4/5 HU, respectively). Consistent calcium scores were obtained from images of different kVs compared to 120 kV, with a relative difference <8%. Auto‐kV provided a 25–34% dose reduction compared to AEC alone. Conclusion A kV‐independent calcium scoring technique can produce artificial 120 kV images with consistent soft tissue and calcium CT numbers compared to standard 120 kV examinations. When coupled with auto‐kV, this technique can reduce radiation by 25–34% compared to that with AEC alone, while providing consistent calcium scores as that of standard 120 kV examinations.
CT for Pre- and Postprocedural Evaluation of Transcatheter Mitral Valve Replacement
Ranganath, Praveen , Moore, Alastair , Collins, Jeremy D. , Foley, Thomas A. , Williamson, Eric E. , Rajiah, Prabhakar , Collins, Jeremy , Foley, Thomas , Rajiah, Prabhakar , Guerrero, Mayra

Mayo Clinic

RadioGraphics | October 1, 2020 | Volume: 40 | Issue: 6 | Pages: 1528-1553

10.1148/rg.2020200027 | PMID 33001784 Get It

Individualized Delay for Abdominal Computed Tomography Angiography Bolus-Tracking Based on Sequential Monitoring: Increased Aortic Contrast Permits Decreased Injection Rate and Lower Iodine Dose
Gutjahr, Ralf , Lee, Yong S. , Halaweish, Ahmed F., Suresh, Vighnesh , Weber, Nikkole M. , Vrtiska, Terri J., Williamson, Eric E. , Schmidt, Bernhard , Fletcher, Joel G. , McCollough, Cynthia H.

Mayo Clinic

Journal of Computer Assisted Tomography | July 3, 2019 | Volume: 43 | Issue: 4 | Pages: 612-618

10.1097/rct.0000000000000874 | PMID 31268876 Get It

Objective The aim of this study was to determine if computed tomography (CT) angiography using an individualized transition delay (CTA-ID) would facilitate reductions in injection rate and iodine dose. Methods The CTA-ID was performed in 20 patients with routine injection rate and iodine dose; 20 patients with injection rate lowered by 1 mL/s; and 40 patients with injection rate lowered by 1 mL/s with 29% less iodine. Routine CTAs in the same or size-matched patients served as controls. Diagnostic image quality and intra-arterial CT numbers were assessed. Results The median transition delay between aortic threshold and CTA-ID image acquisition was significantly longer than with conventional bolus tracking (mean increase, 13.3 seconds; P < 0.0001), with image quality being the same or better. Intra-arterial CT numbers were 200 Hounsfield units or greater for 80 of 80 CTA-ID, but not for 6 of 49 (12%) internal control or for 11 of 80 (14%) size-matched control patients. Conclusion The CTA-ID bolus-tracking software alters transition delays to permit diagnostic CTA examinations despite slower injection rate and less iodine.
Acute ischemic stroke secondary to cardiac embolus of a ‘foreign body’ material after a redo sternotomy for mitral valve replacement: A case report
Fitzgerald, Seán , Rizvi, Asim , Williamson, Eric E. , Doyle, Karen , Kallmes, David F. , Brinjikji, Waleed , Dai, Daying , Fitzgerald, Seán , Lanzino, Giuseppe

Mayo Clinic

Interventional Neuroradiology | November 14, 2018 | Volume: 25 | Issue: 2 | Pages: 208-211

10.1177/1591019918810538 | PMID 30428742 Get It

Summary Cardiac surgery has been shown to be associated with increased risk of acute ischemic stroke. This report presents a case of a successful mechanical embolectomy procedure to treat a patient for an acute ischemic stroke, which was caused by the cardiac embolization of a ‘foreign body’ containing debris following a redo sternotomy procedure for mitral valve replacement and tricuspid valve annuloplasty.
Predictors of 1-year mortality after transcatheter aortic valve replacement
Greason, Kevin L. , Eleid, Mackram F. , Williamson, Eric E. , Sandhu, Gurpreet S. , Holmes, David R. , King, Katherine S. , Nkomo, Vuyisile T.

Mayo Clinic

Journal of Cardiac Surgery | April 14, 2018 | Volume: 33 | Issue: 5 | Pages: 243-249

10.1111/jocs.13574 | PMID 29654615 Get It

Is Intravenous Administration of Iodixanol Associated with Increased Risk of Acute Kidney Injury, Dialysis, or Mortality? A Propensity Score–adjusted Study
McDonald, Robert J. , Williamson, Eric E. , Kallmes, David F. , McDonald, Jennifer S.

Mayo Clinic

Radiology | July 14, 2017 | Volume: 285 | Issue: 2 | Pages: 414-424

10.1148/radiol.2017161573 | PMID 28708022 Get It

Gadolinium Deposition in Human Brain Tissues after Contrast-enhanced MR Imaging in Adult Patients without Intracranial Abnormalities
McDonald, Robert J. , Kallmes, David F. , Jentoft, Mark E. , Paolini, Michael A., Murray, David , Williamson, Eric E. , Eckel, Laurence J. , Murray, David L., McDonald, Jennifer S.

Mayo Clinic

Radiology | June 27, 2017 | Volume: 285 | Issue: 2 | Pages: 546-554

10.1148/radiol.2017161595 | PMID 28653860 Get It

Reducing Iodine Contrast Volume in CT Angiography of the Abdominal Aorta Using Integrated Tube Potential Selection and Weight-Based Method Without Compromising Image Quality
Vasconcelos, Rogerio N., Vrtiska, Terri J., Foley, Thomas A. , Macedo, Thanila A. , Cardona, Juan C. Montoya, Williamson, Eric E. , Vasconcelos, Rogerio, McCollough, Cynthia H. , Fletcher, Joel G.

Mayo Clinic

American Journal of Roentgenology | February 22, 2017 | Volume: 208 | Issue: 3 | Pages: 552-563

10.2214/ajr.16.16613 | PMID 28225687 Get It

Spontaneous coronary artery dissection: challenges of coronary computed tomography angiography
Eleid, Mackram F. , Young, Phillip M. , Williamson, Eric E. , Gulati, Rajiv , Tweet, Marysia S. , Hayes, Sharonne N.

Mayo Clinic

European Heart Journal: Acute Cardiovascular Care | January 31, 2017 | Volume: 7 | Issue: 7 | Pages: 609-613

10.1177/2048872616687098 | PMID 28139136 Get It

Background: There is limited understanding of the role of cardiac computed tomography angiography (CCTA) for assessment of patients with spontaneous coronary artery dissection (SCAD). Methods: In this report we describe the diagnostic utility of CCTA in three young women presenting with signs and symptoms of myocardial ischemia who were eventually diagnosed with SCAD. Results: None of the women had traditional atherosclerotic risk factors. SCAD was not initially identified on CCTA in any of the three women, but was visualized during retrospective analysis in two patients after invasive coronary angiography. In two patients follow-up CCTA imaging was used successfully for subsequent management. Conclusions: In patients presenting with signs or symptoms of acute coronary syndrome, SCAD may be missed or not detectable on CCTA. A negative CCTA should not exclude a diagnosis of SCAD, and invasive coronary angiography should be considered for further evaluation.