Citations

Clear

44 citation(s) found for "Watson, Robert".

Autoimmune epilepsy: findings on MRI and FDG-PET
Watson, Robert E. , Guerin, Julie, Carr, Carrie M. , Liebo, Greta B. , Kotsenas, Amy L. , Guérin, J.

Mayo Clinic

The British Journal of Radiology | September 20, 2018 | Volume: 92 | Issue: 1093 | Pages: No page available

10.1259/bjr.20170869 | PMID 30235015 Get It

Autoimmune epilepsy (AE) is becoming increasingly recognized as a potentially reversible cause of frequent or medically intractable seizures and cognitive deterioration. We describe various presentations of autoimmune encephalopathy which have specifically presented with seizure and describe reported imaging findings. This is organized as a review of the more common autoantibodies which can specifically precipitate seizure according to the intracellular or extracellular location of the targeted antigen. For each antibody, we illustrate their pathophysiology, characteristic clinical presentations with typical effective treatments and prognoses and imaging findings on MRI and PET/CT exams. Parenchymal involvement is variable with the limbic structures typically affected; however, non-limbic cortex, cerebellum, brainstem and basal ganglia can also be involved. In the acute setting, affected regions typically demonstrate T 2 hyperintensity with mild mass effect from edema and increased 18F-fludeoxyglucose uptake. Chronically involved parenchyma will often undergo atrophy and demonstrate decreased metabolism; mesial temporal sclerosis is often the end result when the limbic system is involved. Without treatment, long-term effects from AE range from ongoing cognitive dysfunction and refractory seizures to death. Familiarity with AE may prompt appropriate antibody screening, particularly in cases of refractory seizure disorders. Early investigation and proper management of AE cases may help to prevent parenchymal and neurologic deterioration in these patients.
P3698Correlation of lead length with procedural safety outcomes of magnetic resonance imaging in patients with legacy pacemakers and defibrillators
Padmanabhan, Deepak , Naksuk, Niyada , Deshmukh, Abhishek , Mulpuru, Siva K. , Felmlee, Joel P. , Dalzell, Connie, Olson, Nora E., Jondal, Mary Lou, Watson, Robert E. , Cha, Y, Friedman, Paul A. , Kella, Danesh , Isath, Ameesh , Kapa, Suraj , Asirvatham, Samuel J.

Mayo Clinic

European Heart Journal | August 30, 2018 | Volume: 39 | Issue: suppl_1 | Pages: No page available

10.1093/eurheartj/ehy563.p3698 Get It

Laser ablation for mesial temporal epilepsy: a multi-site, single institutional series
Zimmerman, Richard S. , Brinkmann, Benjamin H. , Tatum, William O. , Crepeau, Amy Z. , Woodrum, David A. , Gorny, Krzysztof R. , Felmlee, Joel P. , Watson, Robert E. , Trenerry, Max R., Marsh, W. Richard , Wharen, Robert E. , Hoxworth, Joseph M. , Vibhute, Prasanna , Brinkmann, Benjamin H , Grewal, Sanjeet S. , Worrell, Gregory A. , Gupta, Vivek , Kaufmann, Timothy J. , Gompel, Jamie J. Van

Mayo Clinic

Journal of Neurosurgery | July 6, 2018 | Volume: No volume available | Issue: No issue available | Pages: 1-8

10.3171/2018.2.jns171873 | PMID 29979119 Get It

OBJECTIVE Although it is still early in its application, laser interstitial thermal therapy (LiTT) has increasingly been employed as a surgical option for patients with mesial temporal lobe epilepsy. This study aimed to describe mesial temporal lobe ablation volumes and seizure outcomes following LiTT across the Mayo Clinic’s 3 epilepsy surgery centers. METHODS This was a multi-site, single-institution, retrospective review of seizure outcomes and ablation volumes following LiTT for medically intractable mesial temporal lobe epilepsy between October 2011 and October 2015. Pre-ablation and post-ablation follow-up volumes of the hippocampus were measured using FreeSurfer, and the volume of ablated tissue was also measured on intraoperative MRI using a supervised spline-based edge detection algorithm. To determine seizure outcomes, results were compared between those patients who were seizure free and those who continued to experience seizures. RESULTS There were 23 patients who underwent mesial temporal LiTT within the study period. Fifteen patients (65%) had left-sided procedures. The median follow-up was 34 months (range 12–70 months). The mean ablation volume was 6888 mm 3 . Median hippocampal ablation was 65%, with a median amygdala ablation of 43%. At last follow-up, 11 (48%) of these patients were seizure free. There was no correlation between ablation volume and seizure freedom (p = 0.69). There was also no correlation between percent ablation of the amygdala (p = 0.28) or hippocampus (p = 0.82) and seizure outcomes. Twelve patients underwent formal testing with computational visual fields. Visual field changes were seen in 67% of patients who underwent testing. Comparing the 5 patients with clinically noticeable visual field deficits to the rest of the cohort showed no significant difference in ablation volume between those patients with visual field deficits and those without (p = 0.94). There were 11 patients with follow-up neuropsychological testing. Within this group, verbal learning retention was 76% in the patients with left-sided procedures and 89% in those with right-sided procedures. CONCLUSIONS In this study, there was no significant correlation between the ablation volume after LiTT and seizure outcomes. Visual field deficits were common in formally tested patients, much as in patients treated with open temporal lobectomy. Further studies are required to determine the role of amygdalohippocampal ablation.
207Clinical utility of performing magnetic resonance imaging in patients with cardiac implantable electronic devices in situ
Padmanabhan, Deepak , Tandon, Navdeep, Mulpuru, Siva K. , Mehta, Ramila A. , Dalzell, Connie, Olson, Nora E., Felmlee, Joel P. , Jondal, Mary Lou, Watson, Robert E. , Cha, YONG-M, Friedman, Paul A. , Kella, Danesh , Deshmukh, Amrish , Kapa, Suraj , Asirvatham, Samuel J.

Mayo Clinic

EP Europace | March 19, 2018 | Volume: 20 | Issue: suppl_1 | Pages: i22-i23

10.1093/europace/euy015.056 Get It

Safety of Laser Interstitial Thermal Therapy in Patients With Pacemakers
Gorny, Krzysztof R. , Favazza, Christopher , Watson, Robert E. , Favazza, Christopher P, Grewal, Sanjeet S. , Kaufmann, Timothy J. , Gompel, Jamie J. Van

Mayo Clinic

Operative Neurosurgery | February 10, 2018 | Volume: 15 | Issue: 5 | Pages: E69-E72

10.1093/ons/opx292 | PMID 29444267 Get It

Abstract BACKGROUND AND IMPORTANCE Laser interstitial thermal therapy (LiTT) has increasingly been used as a treatment option for medically refractory epilepsy, tumors, and radiation necrosis. The use of LiTT requires intraoperative magnetic resonance (MR) thermography. This can become an issue in patients with other implanted therapeutic devices such as pacemakers and vagal nerve stimulators due to concerns regarding increases in the specific absorption rate (SAR). This is a technical case report demonstrating a successfully and safely performed LiTT in a 1.5-T magnetic resonance imaging (MRI) in a patient with a pacemaker for mesial temporal sclerosis. CLINICAL PRESENTATION An 83-yr-old gentleman who had an implanted cardiac pacemaker presented with medically intractable epilepsy and was confirmed to have mesial temporal sclerosis on imaging. Video electroencephalography demonstrated concordant ipsilateral seizures and semiology. He underwent LiTT for ablation of the mesial temporal lobe. This was performed with the below described protocol with a cardiology nurse monitoring the patient's cardiac condition and a physicist monitoring SAR, and MR imaging quality without any adverse events. CONCLUSION This study reports on a protocol of cardiac and MR SAR to safely perform MR-guided LiTT in the setting of traditional pacemakers in patients who are not pacemaker dependent.
Mortality After Magnetic Resonance Imaging of the Brain in Patients With Cardiovascular Implantable Devices
Padmanabhan, Deepak , Jondal, Mary Lou, Hodge, David O. , Mehta, Ramila A. , Acker, Nancy G., Dalzell, Connie, Asirvatham, Samuel J. , Cha, Yong‐Mei , Felmlee, Joel P. , Watson, Robert E. , Friedman, Paul A. , Jondal, Mary L, Dalzell, Connie M, Kapa, Suraj , Asirvatham, Samuel J

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | January 10, 2018 | Volume: 11 | Issue: 1 | Pages: No page available

10.1161/circep.117.005480 | PMID 29321191 Get It

Background: Use of magnetic resonance imaging (MRI) brain is restricted in patients with cardiovascular implantable electronic devices (CIEDs). We proposed to determine whether mortality difference exists for patients with non–MRI-conditional CIEDs undergoing brain MRI compared with controls. Methods and Results: Retrospective analysis of prospectively collected data was performed to compare all-cause mortality in patients with CIEDs undergoing brain MRI (CIED-MRI) with 3 control groups matched for age, sex, imaging year, and type of CIED: (1) no CIED, brain MRI (no–CIED-MRI); (2) CIED, brain computerized tomography (CT) scan (CIED-CT); and (3) no CIED, brain CT (no–CIED-CT). The primary outcome was a significant difference ( P <0.05) between estimated mortality rates. Secondary outcomes were changes in device function before and after brain MRI. The estimated all-cause mortality at 5 years for the CIED-MRI group [mean age (±SD), 68.2 years (15.3 years); 61.2% men] was not significantly different from patients who underwent CT with or without a device (CIED-CT group: hazard ratio, 0.814; 95% confidence interval, 0.593–1.117; P =0.2; no–CIED-CT group: hazard ratio, 1.149; 95% confidence interval, 0.818–1.613; P =0.4). There was a significant increase in mortality between CIED-MRI and no–CIED-MRI groups (hazard ratio, 1.463; 95% confidence interval, 1.019–2.099; P =0.04). Conclusions: Brain MRI in patients with CIEDs does not carry an increased mortality risk compared with brain CT and can be performed with adherence to appropriate procedural protocols.
MR Imaging and Cochlear Implants with Retained Internal Magnets: Reducing Artifacts near Highly Inhomogeneous Magnetic Fields
Edmonson, Heidi A. , Carlson, Matthew L. , Patton, Alice , Watson, Robert E. , Patton, Alice C

Mayo Clinic

RadioGraphics | January 10, 2018 | Volume: 38 | Issue: 1 | Pages: 94-106

10.1148/rg.2018170135 | PMID 29320320 Get It

Deep Venous Thrombosis and Bilateral Pulmonary Embolism Revealing Silent Celiac Disease: Case Report and Review of the Literature
Dumic, Igor , Martin, Scott, Salfiti, Nadim, Alempijević, Tamara , Watson, Robert, Alempijevic, Tamara , Dumic, Igor , Watson, Robert James

Mayo Clinic

Case Reports in Gastrointestinal Medicine | December 12, 2017 | Volume: 2017 | Issue: No issue available | Pages: 1-8

10.1155/2017/5236918 | PMID 29379656 Get It

Celiac disease (CD) is a systemic, chronic autoimmune disease that occurs in genetically predisposed individuals following dietary gluten exposure. CD can present with a wide range of gastrointestinal and extraintestinal manifestations and requires lifelong adherence to a gluten-free diet [GFD]. Venous thromboembolism (VTE) as a presentation of celiac disease is unusual and rarely reported. We present a case of a 46-year-old man who was admitted for shortness of breath and pleuritic chest pain and was found to have iron deficiency anemia, deep venous thrombosis, and bilateral pulmonary emboli (PE). After work-up for his anemia, the patient was diagnosed with CD. Comprehensive investigation for inherited or acquired prothrombotic disorders was negative. It is becoming increasingly recognized that CD is associated with an increased risk for VTE. PE, however, as a presentation of CD is exceedingly rare and to the best of our knowledge this is the third case report of such an occurrence and the only case report of a patient from North America. It is important to recognize that the first symptoms or signs of celiac disease might be extraintestinal. Furthermore, VTE as a presentation of CD is rare but life-threatening.
Evaluation of feasibility of 1.5 Tesla prostate MRI using body coil RF transmit in a patient with an implanted vagus nerve stimulator
Favazza, Christopher , Edmonson, Heidi A. , Shu, Yunhong , Felmlee, Joel P. , Watson, Robert E. , Gorny, Krzysztof R. , Favazza, Christopher P, Ma, Chi , Ma, Chi

Mayo Clinic

Medical Physics | September 7, 2017 | Volume: 44 | Issue: 11 | Pages: 5749-5754

10.1002/mp.12567 | PMID 28880381 Get It

PurposeTo assess risks of RF‐heating of a vagus nerve stimulator (VNS) during 1.5 T prostate MRI using body coil transmit and to compare these risks with those associated with MRI head exams using a transmit/receive head coil.MethodsSpatial distributions of radio‐frequency (RF) B1 fields generated by transmit/receive (T/R) body and head coils were empirically assessed along the long axis of a 1.5 T MRI scanner bore. Measurements were obtained along the center axis of the scanner and laterally offset by 15 cm (body coil) and 7 cm (head coil). RF‐field measurements were supplemented with direct measurements of RF‐heating of 15 cm long copper wires affixed to and submerged in the “neck” region of the gelled saline‐filled (sodium chloride and polyacrylic acid) “head‐and‐torso” phantom. Temperature elevations at the lead tips were measured using fiber‐optic thermometers with the phantom positioned at systematically increased distances from the scanner isocenter.ResultsB1 field measurements demonstrated greater than 10 dB reduction in RF power at distances beyond 28 cm and 24 cm from isocenter for body and head coil, respectively. Moreover, RF power from body coil transmit at distances greater than 32 cm from isocenter was found to be lower than from the RF power from head coil transmit measured at locations adjacent to the coil array at its opening. Correspondingly, maximum temperature elevations at the tips of the copper wires decreased with increasing distance from isocenter — from 7.4°C at 0 cm to no appreciable heating at locations beyond 40 cm.ConclusionsFor the particular scanner model evaluated in this study, positioning an implanted VNS farther than 32 cm from isocenter (configuration achievable for prostate exams) can reduce risks of RF‐heating resulting from the body coil transmit to those associated with using a T/R head coil.
Expanded phenotypes and outcomes among 256 LGI 1/ CASPR 2‐ I g G
Gadoth, Avi , Pittock, Sean J. , Dubey, Divyanshu , McKeon, Andrew , Britton, Jeff W., Schmeling, John E., Smith, Aurelia, Watson, Robert E. , Flanagan, Eoin P. , Lennon, Vanda A. , Klein, Christopher J. , Kotsenas, Amy L. , Watson, Robert E , Pittock, S J , Britton, Jeffrey W. , Lachance, Daniel Honore , Flanagan, E P , Klein, Christopher J , McKeon, Andrew , Dubey, Divyanshu

Mayo Clinic

Annals of Neurology | June 19, 2017 | Volume: 82 | Issue: 1 | Pages: 79-92

10.1002/ana.24979 | PMID 28628235 Get It

Objective To describe an expanded phenotypic spectrum and longitudinal outcome in 256 LGI1‐IgG–seropositive and/or CASPR2‐IgG–seropositive patients. Methods Patients were identified through service neural autoantibody evaluation. Ninety‐five had longitudinal follow‐up (7–456 months; median = 35). Results Among 3,910 patients tested, 196 were LGI1‐IgG positive, 51 were CASPR2‐IgG positive, and 9 were dual positive. Cerebrospinal fluid testing was less sensitive than serum testing, detecting only 24 of 38 (63%) LGI1‐IgG–positive and 5 of 6 (83%) CASPR2‐IgG–positive patients. LGI1‐IgG–positive specimens had higher voltage‐gated potassium channel–IgG immunoprecipitation values (0.33nmol/l, range = 0.02–5.14) than CASPR2‐IgG–positive specimens (0.10nmol/l, range = 0.00–0.45, p < 0.001). Of patients presenting with pain or peripheral nervous system (PNS) manifestations, 39% were LGI1‐IgG seropositive (7% had solely neuropathy or pain). Multivariate analysis identified age as the only significant predictor of central nervous system (CNS) versus PNS involvement (>50 years; odds ratio = 15, p < 0.001). Paroxysmal dizziness spells (PDS), a unique LGI1‐IgG accompaniment (14% of patients), frequently delayed the diagnosis. T2‐mesiotemporal hyperintensity was more common in LGI1‐IgG–positive (41%) than in CASPR2‐IgG–positive patients ( p = 0.033). T1‐bright basal ganglia were confined to LGI1‐IgG–positive patients with faciobrachial–dystonic seizures (9 of 39, 31%). Cancer was found in 44% of LGI1‐IgG/CASPR2‐IgG dual seropositive patients (one‐third thymoma). Response to initial immunotherapy was favorable in 97%; mean modified Rankin score was 3 (range = 1–5) at onset and 1.74 (range = 0–6) at last follow‐up, with 9% having severe refractory disability, 20% being asymptomatic, 28% receiving immunotherapy, and 58% receiving antiepileptic medication. Interpretation Older age is a strong predictor of CNS involvement in patients seropositive for CASPR2‐IgG or LGI1‐IgG. Pain, peripheral manifestations, and stereotypic paroxysmal dizziness spells are common with LGI1‐IgG. Response to initial immunotherapy is often favorable, but some patients remain severely disabled, requiring long‐term immunotherapy and/or antiepileptic medications. Ann Neurol 2017;82:79–92