Citations

Clear

73 citation(s) found for "Tokish, John".

All‐Arthroscopic Falciform Portal Biceps Tenodesis
Makovicka, Justin L. , Brinkman, Joseph C. , Benner, Nathan, Tokish, Aiden J., Moore, M. Lane , Tokish, John M. , Moore, M Lane

Mayo Clinic

Arthroscopy Techniques | January 1, 2024 | Volume: 13 | Issue: 2 | Pages: No page available

10.1016/j.eats.2023.09.017 | PMID 38435253 Get It

Abstract Biceps tenodesis has been proven to be an effective treatment for biceps tendon and superior labral pathology. Many techniques including both open and arthroscopic approaches have been reported. Open techniques afford management of the entire proximal biceps tendon but are limited by wound healing issues, increased bleeding, and increased surgical time. Arthroscopic tenodesis offers benefits in terms of surgical efficiency, cosmesis, and bleeding risk. However, standard arthroscopic tenodesis only addresses intra‐articular biceps pathology. In this report we describe an all‐arthroscopic biceps tenodesis technique at the suprapectoral region of the humerus using knotless suture anchor fixation. Technique Video video See video under supplementary data.
Performance-Enhancing Drugs in Healthy Athletes: An Umbrella Review of Systematic Reviews and Meta-analyses
Warrier, Alec A. , Azua, Eric N. , Kasson, Luke B. , Allahabadi, Sachin , Khan, Zeeshan A. , Swindell, Hasani W. , Tokish, John M. , Mameri, Enzo S. , Chahla, Jorge

Mayo Clinic

Sports Health: A Multidisciplinary Approach | September 9, 2023 | Volume: 16 | Issue: 5 | Pages: 695-705

10.1177/19417381231197389 | PMID 37688400 Get It

Context: Many clinicians, trainers, and athletes do not have a true understanding of the effects of commonly used performance-enhancing drugs (PEDs) on performance and health. Objective: To provide an evidence-based review of 7 commonly used pharmacological interventions for performance enhancement in athletes. Data Sources: PubMed and Scopus databases were searched on April 8, 2022. Study Selection: Systematic reviews (SRs) and meta-analyses (MAs) assessing the performance-enhancing effects of the following interventions were included: androgenic anabolic steroids (AAS), growth hormone (GH), selective androgen receptor modulators (SARMs), creatine, angiotensin-converting enzyme (ACE)-inhibitors, recombinant human erythropoietin (rHuEPO), and cannabis. Study Design: Umbrella review of SRs and MAs. Level of Evidence: Level 4. Data Extraction: Primary outcomes collected were (1) body mass, (2) muscle strength, (3) performance, and (4) recovery. Adverse effects were also noted. Results: A total of 27 papers evaluating 5 pharmacological interventions met inclusion criteria. No studies evaluating SARMs or ACE-inhibitors were included. AAS lead to a 5% to 52% increase in strength and a 0.62 standard mean difference in lean body mass with subsequent lipid derangements. GH alters body composition, without providing a strength or performance benefit, but potential risks include soft tissue edema, fatigue, arthralgias, and carpel tunnel syndrome. Creatine use during resistance training can safely increase total and lean body mass, strength, and performance in high-intensity, short-duration, repetitive tasks. Limited evidence supports rHuEPO benefit on performance despite increases in both VO 2 max and maximal power output, and severe cardiovascular risks are documented. Cannabis provides no performance benefit and may even impair athletic performance. Conclusion: In young healthy persons and athletes, creatine can safely provide a performance-enhancing benefit when taken in controlled doses. AAS, GH, and rHuEPO are associated with severe adverse events and do not support a performance benefit, despite showing the ability to change bodily composition, strength, and/or physiologic measures. Cannabis may have an ergolytic, instead of ergogenic, effect.
Paper 50: Biceps Autograft Patch Augmentation for Rotator Cuff Repair: The Effect of Point of Care Compression on Tenocyte Viability.
Colbath, Gregory, Tokish, John M. , Mercuri, Jeremy , Denard, Patrick J.

Mayo Clinic

Orthopaedic Journal of Sports Medicine | July 31, 2023 | Volume: 11 | Issue: 7_suppl3 | Pages: No page available

10.1177/2325967123s00075 Get It

Objectives: Augmentation of rotator cuff repair in patients at risk for retear has gained popularity. These techniques have generally consisted of allograft and xenograft patches. Recently, use of an autograft biceps from the normally discarded portion after biceps tenodesis was described as a potential patch for rotator cuff repair augmentation. As an autograft, it is free and readily available. The original description prepared the patch by placing it through a commercial skin graft preparation station. This technique results in a significant decrease in tenocyte viability, however, and results in a patch that is difficult to work with. Recently, an autograft compression plate has been employed to use as a point of care processor for adapting the discarded long head of the biceps after tenodesis into an autograft patch. The purpose of this study was to evaluate the feasibility of this point of care graft preparation method, and to specifically evaluate its effect on tenocyte viability in patients undergoing patch augmentation for rotator cuff repair. Methods: We reviewed the medical records of consecutive patients who underwent biceps tenodesis for either rotator cuff repair or anatomic shoulder arthroplasty. After tenodesis, and after 27 mm of the long head of the biceps was secured for compression into the patch, the remaining length of normally discarded tendon was longitudinally split, resulting in 2 equal lengths of remnant tendon from the same zone of the tendon. One sample was sent to pathology with no preparation, and the other was prepared as a biceps autograft patch using the autograft compression plate according to the manufacturer’s recommendations. Once prepared, this second biceps sample was sent to pathology along with the first. The request was to evaluate for tenocyte viability. Pathologists were not told which sample was compressed. Records were reviewed to determine if biceps tendon samples were viable at the time of harvest, and whether the compression process affected a change between the first and second specimen. Results: 20 consecutive patients were reviewed. All 20 biceps produced usable patches. The remnant biceps samples that were sent to pathology revealed the following: Sixteen of the 20 patients had biceps tenocyte viability that were read out as completely normal in both the compressed and non compressed samples. Of the 4 patients that did show some degree of tenocyte necrosis or death, 3 of the patients had identical findings between the compressed and non-compressed samples. Only 1/20 (5%) of the patients showed a difference between the compressed sample and the non-compressed sample, with the compressed sample demonstrating small areas of “patchy necrosis” while the non compressed sample showed normal tendon in that specimen. Conclusions: Compression of the long head of the biceps results in an autograft patch that is a promising option in rotator cuff augmentation. The method of compression plating to process the long head of the biceps remnant into an augmentation patch appears to have no significant effect on tenocyte viability, suggesting that the patch has live tenocytes at the time of point of care augmentation.
Rotator Cuff Repair with Knotless All‐Suture Medial Row Anchors and Biceps Autograft Augmentation
Hassebrock, Jeffrey D. , McCarthy, Timothy Patrick , Sylvia, Stephen M. , Stokes, Daniel J. , Shinsako, Kevin K. , Tokish, John M. , Hassebrock, Jeffrey D , McCarthy, Timothy P., Frank, Rachel M

Mayo Clinic

Arthroscopy Techniques | July 17, 2023 | Volume: 12 | Issue: 8 | Pages: No page available

10.1016/j.eats.2023.04.005 | PMID 37654888 Get It

Abstract Incomplete healing and/or functional failure following rotator cuff tear repair remains a challenging problem for both patients and surgeons. Augmentation strategies are growing to increase healing through biologic and mechanical mechanisms to improve functional results after arthroscopic rotator cuff repair. The majority of currently described augmentation techniques use allograft tissue. An alternative, low‐cost, autograft option for augmentation is the use of the long head of biceps tendon autograft as a free functional graft. Here, we describe the use of autograft biceps tendon as a viable option for augmentation of double‐row rotator cuff repair with knotless all‐suture suture anchors. Technique Video video See video under supplementary data.
Public Interest in Shoulder Platelet‐Rich Plasma Injections Is Increasing: A 10‐Year Google Trends Analysis
Brinkman, Joseph C. , McQuivey, Kade S. , Hassebrock, Jeffrey D. , Moore, M. Lane , Pollock, Jordan R. , Tokish, John M. , Moore, M Lane , Pollock, Jordan Riley , Hassebrock, Jeffrey D

Mayo Clinic

Arthroscopy, Sports Medicine, and Rehabilitation | July 13, 2023 | Volume: 5 | Issue: 4 | Pages: No page available

10.1016/j.asmr.2023.04.026 | PMID 37502225 Get It

Purpose To quantify and analyze public interest trends in platelet‐rich plasma (PRP) therapy for shoulder pathology between 2011 and 2020 using Google Trends data. Methods Google Trends data were queried for online search data ranging from January 2011 to December 2020. Various combinations of terms related to PRP and shoulder pathology were queried. Terms related to corticosteroid therapy in association with shoulder pathology were also generated for comparative analysis. Analyses were performed regarding trends in online search volumes. Results Linear models were generated to evaluated trends in the volume of online searches for PRP and corticosteroid therapy for shoulder pathology. For both the PRP and steroid groups, linear models showed a statistically significant increase in search volume for the period studied ( P < .001). The PRP group showed a significantly greater growth rate than the steroid group ( P < .001). There were no statistically significant differences in online search volume when compared between different geographic and socioeconomic locations. Conclusions This study indicates consistently increasing public interest in PRP injections in the shoulder. The rate of online search volume growth of PRP is significantly greater than that of corticosteroid injections for the period studied. Clinical Relevance Awareness of patient perceptions has value in informing shared decision making, aligning patient expectations, and guiding areas of future research. Each of these has an impact on patient care. Being aware of patient interest and expectations is particularly important in areas with controversial or emerging research.
Magnetic Resonance Imaging Analysis Demonstrates Improved Reliability in Measuring Shoulder Glenoid Bone Loss Using a Two‐Thirds Glenoid Height Technique Compared to the “Best‐fit Circle”
Makovicka, Justin L. , Moore, M. Lane , Pollock, Jordan R. , Rodriguez, Marina , Shaha, James S., Haglin, Jack M. , Tokish, John M. , Moore, M Lane , Pollock, Jordan Riley

Mayo Clinic

Arthroscopy | July 6, 2023 | Volume: 40 | Issue: 3 | Pages: 666-671

10.1016/j.arthro.2023.06.048 | PMID 37419223 Get It

Purpose To evaluate the superior to inferior glenoid height as a reliable reference in best‐fit circle creation for glenoid anatomy. Methods The morphology of the native glenoid was evaluated using magnetic resonance imaging (MRI) in patients without shoulder instability. Using T1 sagittal MRI images, 2 reviewers independently estimated glenoid size using the two‐thirds technique and the “best‐fit circle” technique at 2 different times. A Student t ‐test was used to determine significant difference between the two methodologies. Inter‐ and intra‐rater reliability were calculated using interclass and intraclass coefficients. Results This study included 112 patients. Using the results of glenoid height and “best‐fit circle” diameter, the diameter of the “best‐fit circle” was found to intersect the glenoid line at 67.8% of the glenoid height on average. We found no significant difference between the 2 measures of glenoid diameter (27.6 vs 27.9, P = .456). The interclass and intraclass coefficients for the two‐third method were 0.85 and 0.88, respectively. The interclass and intraclass coefficients for the perfect circle methods were 0.84 and 0.73, respectively. Conclusions We determined that the diameter of a circle placed on the inferior glenoid using the “best‐fit circle” technique corresponds to 67.8% of the glenoid height. Additionally, we found that constructing a perfect circle using a diameter equal to two‐thirds the height of the glenoid may improve intraclass reliability. Level of Evidence Level IV, retrospective cohort study.
Survival of anterior cruciate ligament reconstructions in active‐duty military populations
Anderson, Ashley B. , Dekker, Travis J. , Pav, Veronika , Mauntel, Timothy C. , Provencher, Matthew T. , Tokish, John M. , Musahl, Volker , Sansone, Michael , Dickens, Jonathan F. , Dickens, Jonathan F , Extremity War Injury Symposium Working Group , Provencher, Matthew T. , Sansone, Michael, Karlsson, Jón

Mayo Clinic

Knee Surgery, Sports Traumatology, Arthroscopy | February 21, 2023 | Volume: 31 | Issue: 8 | Pages: 3196-3203

10.1007/s00167-023-07335-w | PMID 36809509 Get It

AbstractPurposeAnterior cruciate ligament tears and anterior cruciate ligament reconstruction (ACLR) are common in young athletes. The modifiable and non‐modifiable factors contributing to ACLR failure and reoperation are incompletely understood. The purpose of this study was to determine ACLR failure rates in a physically high‐demand population and identify the patient‐specific risk factors, including prolonged time between diagnosis and surgical correction, that portend failure.MethodsA consecutive series of military service members with ACLR with and without concomitant procedures (meniscus [M] and/or cartilage [C]) done at military facilities between 2008 and 2011 was completed via the Military Health System Data Repository. This was a consecutive series of patients without a history of knee surgery for two years prior to the primary ACLR. Kaplan–Meier survival curves were estimated and evaluated with Wilcoxon test. Cox proportional hazard models calculated hazard ratios (HR) with 95% confidence intervals (95% CI) to identify demographic and surgical factors that influenced ACLR failure.ResultsOf the 2735 primary ACLRs included in the study, 484/2,735 (18%) experienced ACLR failure within four years, including (261/2,735) (10%) undergoing revision ACLR and (224/2,735) (8%) due to medical separation. The factors that increased failure include Army Service (HR 2.19, 95% CI 1.67, 2.87), > 180 days from injury to ACLR (HR 1.550, 95% CI 1.157, 2.076), tobacco use (HR 1.429 95% CI 1.174, 1.738), and younger patient age (HR 1.024, 95% CI 1.004, 1.044).ConclusionThe overall clinical failure rate of service members with ACLR is 17.7% with minimum four‐year follow‐up, where more patients are likely to fail due to revision surgery than medical separation. The cumulative probability of survival at 4 years was 78.5%. Smoking cessation and treating ACLR patients promptly are modifiable risk factors impacting either graft failure or medical separation.Level of evidenceLevel III.
Arthroscopic-Assisted Anterior Glenoid Reconstruction Using Nonrigid Fixation With Distal Tibia Osteochondral Allograft
Riccio, Cory A., Tokish, John M. , Kilcoyne, Kelly G. , Hoyt, Benjamin W , LeClere, Lance E. , Dickens, Jonathan F.

Mayo Clinic

Video Journal of Sports Medicine | February 10, 2023 | Volume: 3 | Issue: 1 | Pages: No page available

10.1177/26350254221131053 | PMID 40308546 Get It

Introduction: Traumatic anterior glenohumeral instability events result in a capsulolabral (Bankart lesion) and/or osseous injury with subsequent attritional bone loss, particularly with recurrence. Up to 88% of patients with recurrent instability experience glenoid bone loss, which predisposes to future dislocations and subluxations, even with arthroscopic capsulolabral repair. The surgical management of glenoid bone loss includes a number of different techniques such as the Latarjet or coracoid transfer as well as other osseous and osteoarticular autografts and allografts. However, operative management of shoulder instability has increasingly shifted toward arthroscopic approaches with preservation of anatomy when possible. Indications: Arthroscopic-assisted allograft distal tibia bone block augmentation to the anterior glenoid is indicated for revision anterior glenohumeral instability procedures with anterior bone loss and in primary cases of anterior instability with critical bone loss. Technique: Our technique for nonrigid arthroscopic anterior glenoid reconstruction with allograft distal tibia and anterior labral repair is performed preferentially in the lateral position without necessitating patient repositioning. The preplanned tibial bone block is prepared on a back table prior to the arthroscopic procedure. After creation of portals and elevation of labral tissue, a guide and drill are used to introduce a retrograde reamer which is deployed to create a perpendicular edge for apposition of the allograft tibia. The bone block is then introduced through a rotator interval portal by pulling sutures retrograde through glenoid bone tunnels and is secured to the prepared surface medial to the liberated labrum. The articular surface of the graft and glenoid are aligned and suture-based fixation is used to compress the bone block against the native glenoid. The anterior labral tissue is then mobilized over the graft and repaired to the native glenoid when possible. Description/Conclusion: The benefits of allograft tibia augmentation for anterior instability with glenoid bone loss include an anatomic joint surface restoration including articular cartilage, lack of donor site morbidity, and a minimally invasive arthroscopic approach. When performed arthroscopically and with nonrigid fixation, this technique permits concurrent anterior labral repair and anatomic reconstruction, safe graft passage without necessity of a far medial portal, and expeditious return to function.
Shoulder Range of Motion Measurements and Baseball Elbow Injuries: Ambiguity in Scientific Models, Approach, and Execution is Hurting Overhead Athlete Health
Bullock, Garrett S. , Martin, Chelsea , Losciale, Justin M. , Tokish, John M. , Camp, Christopher L. , Shanley, Ellen , Camp, Christopher, Camp, Christopher L. , Thigpen, Charles A. , Michener, Lori Ann , Whiteley, Rod J. , Waterman, Brian Robert

Mayo Clinic

Arthroscopy, Sports Medicine, and Rehabilitation | December 12, 2022 | Volume: 5 | Issue: 1 | Pages: No page available

10.1016/j.asmr.2022.11.001 | PMID 36866292 Get It

Abstract Elbow injuries are a significant and increasing issue in baseball. Elbow injuries account for 16% of all injuries sustained at the professional level and collegiate level. Because of the continued rise in injury rates, loss of performance value, and medical burden, sports medicine clinicians have attempted to research the causes underlying this injury epidemic in an attempt to help mitigate baseball elbow injuries. Shoulder range of motion (ROM) is the most researched clinical metric related to elbow injuries in baseball and has the greatest consensus as a viable prognostic factor specifically for medial elbow injury. Shoulder ROM is easy to measure, can be modified through stretching and manual therapy interventions, and can be easily assessed during preseason screening throughout all baseball levels. Despite a large number of studies and the widespread use of shoulder ROM in injury risk screening, current findings are unclear as to whether there is a true cause‐effect relation with baseball elbow injuries. We argue that the conflicting findings revolving around the value of shoulder ROM measurements associated with baseball elbow injuries are the result of 4 gaps in the research approaches implemented to date: ambiguous research questions, mixed study populations, statistical models used, and shoulder ROM methodology. Specifically, there is a mismatch of methods, statistical models, and conclusions such as (1) investigating the association (i.e., correlation) between shoulder ROM measurements and injury and (2) investigating the cause‐effect relation of shoulder ROM to baseball injuries. The purpose of this article is to detail the required scientific steps to evaluate whether preseason shoulder ROM is a potential causal factor for pitching elbow injury. We also provide recommendations to allow for future causal inferences to be made between shoulder ROM and elbow injury. This information will ultimately assist in informing clinical models of care and decision making for baseball throwers.
Human Adipose- and Amnion-Derived Mesenchymal Stromal Cells Similarly Mitigate Osteoarthritis Progression in the Dunkin Hartley Guinea Pig
Kwapisz, Adam , Walters, Joshua , Cosh, Heather, Burnikel, Brian, Tokish, John, Mercuri, Jeremy , Bowman, Mackenzie, Cosh, Heather, Ye, Tong

Mayo Clinic

The American Journal of Sports Medicine | October 27, 2022 | Volume: 50 | Issue: 14 | Pages: 3963-3973

10.1177/03635465221126683 | PMID 36300544 Get It

Background: Clinical trials are currently underway to investigate the efficacy of intra-articular administration of mesenchymal stromal cells (MSCs) to mitigate osteoarthritis (OA) progression in the knee. Although multiple MSC sources exist, studies have yet to determine whether differences in therapeutic efficacy exist between them. Purpose: To compare the ability of intra-articularly injected adipose-derived MSCs (AD-MSCs) and amnion-derived MSCs (AM-MSCs) to mitigate the progression of knee OA in a small animal model of spontaneous OA, as well as to compare the therapeutic potential of MSCs in hyaluronic acid (HA) and in HA only with saline (OA) controls. Study Design: Controlled laboratory study. Methods: Injections of AD-MSCs or AM-MSCs suspended in HA or HA only were performed in the rear stifle joints of 3-month-old Dunkin Hartley guinea pigs (DHGPs). Repeat injections occurred at 2 and 4 months after the initial injection in each animal. Contralateral limbs received saline injections and served as untreated controls. Subsequently, joints were analyzed for osteoarthritic changes of the cartilage and subchondral bone via histologic and biochemical analyses. To evaluate MSC retention time in the joint space, DHGPs received a single intra-articular injection of fluorescently labeled AD-MSCs or AM-MSCs, and the fluorescence intensity was longitudinally tracked via an in vivo imaging system. Results: No statistically significant differences in outcomes were found when comparing the ability of AD-MSCs and AM-MSCs to mitigate OA. However, the injection of AD-MSCs, AM-MSCs, and HA-only treatments more effectively mitigated cartilage damage compared with that of saline controls by demonstrating higher amounts of cartilage glycosaminoglycan content and improved histological proteoglycan scoring while reducing the percentage of osteophytes present. Conclusion: Intra-articular injection of AD-MSCs, AM-MSCs, or HA only was able to similarly mitigate the progression of cartilage damage and reduce the percentage of osteophytes compared with that of saline controls in the DHGP. However, this study was unable to establish the superiority of AD-MSCs versus AM-MSCs as a treatment to mitigate spontaneous OA. Clinical Relevance: MSCs demonstrate the ability to mitigate the progression of knee OA and thus may be used in a prophylactic approach to delay the need for end-stage treatment strategies.