Citations

Clear

96 citation(s) found for "Sood, A".

Empirical Mode Decomposition-Based Deep Learning Model Development for Medical Imaging: Feasibility Study for Gastrointestinal Endoscopic Image Classification
Deb, Mou, Dhar, Mrinal Kanti , Elangovan, Poonguzhali , Gopalakrishnan, Keerthy, Sood, Divyanshi, Sethi, Aaftab, Afroze, Sabah , Bansal, Sourav , Goudel, Aastha , Parikh, Charmy, Kaur, Avneet , Rapolu, Swetha, Panjwani, Gianeshwaree Alias Rachna , ANSARI, RABIAH ASLAM, Asadimanesh, Naghmeh, Karuppiah, Shiva Sankari, Helgeson, Scott A. , Arunachalam, Shivaram P. , Elangovan, Poonguzhali , Arunachalam, S P , Helgeson, Scott A , Panjwani, Gianeshwaree Alias Rachna , SETHI, AAFTAB, Asadimanesh, Naghmeh , Akshintala, Venkata S.

Mayo Clinic

Journal of Imaging | December 22, 2025 | Volume: 12 | Issue: 1 | Pages: 4

10.3390/jimaging12010004 | PMID 41590889 Get It

This study proposes a novel two-dimensional Empirical Mode Decomposition (2D EMD)-based deep learning framework to enhance model performance in multi-class image classification tasks and potential early detection of diseases in healthcare using medical imaging. To validate this approach, we apply it to gastrointestinal (GI) endoscopic image classification using the publicly available Kvasir dataset, which contains eight GI image classes with 1000 images each. The proposed 2D EMD-based design procedure decomposes images into a full set of intrinsic mode functions (IMFs) to enhance image features beneficial for AI model development. Integrating 2D EMD into a deep learning pipeline, we evaluate its impact on four popular models (ResNet152, VGG19bn, MobileNetV3L, and SwinTransformerV2S). The results demonstrate that subtracting IMFs from the original image consistently improves accuracy, F1-score, and AUC for all models. The study reveals a notable enhancement in model performance, with an approximately 9% increase in accuracy compared to counterparts without EMD integration for ResNet152. Similarly, there is an increase of around 18% for VGG19L, 3% for MobileNetV3L, and 8% for SwinTransformerV2. Additionally, explainable AI (XAI) techniques, such as Grad-CAM, illustrate that the model focuses on GI regions for predictions. This study highlights the efficacy of 2D EMD in enhancing deep learning model performance for GI image classification, with potential applications in other domains.
A Novel Unsupervised You Only Listen Once (YOLO) Machine Learning Platform for Automatic Detection and Characterization of Prominent Bowel Sounds Towards Precision Medicine
Yerrapragada, Gayathri, Lee, Jieun , Shariff, Mohammed Naveed , Elangovan, Poonguzhali , Gopalakrishnan, Keerthy, Kaur, Avneet , Sood, Divyanshi, Rapolu, Swetha, Gohri, Jay , Panjwani, Gianeshwaree Alias Rachna , Ansari, Rabiah Aslam, Mikkilineni, Jahnavi, Asadimanesh, Naghmeh, Natarajan, T.K. , Janarthanan, Jayarajasekaran, Karuppiah, Shiva Sankari, Iyer, Vivek , Helgeson, Scott A. , Arunachalam, Shivaram P. , Shariff, Mohammad Naveed , Natarajan, Thangeswaran , Iyer, Vivek N , Arunachalam, S P , Elangovan, Poonguzhali , Helgeson, Scott A , Panjwani, Gianeshwaree Alias Rachna , Yerrapragada, Gayathri, Ansari, Rabiah Aslam, Akshintala, Venkata S.

Mayo Clinic

Bioengineering | November 19, 2025 | Volume: 12 | Issue: 11 | Pages: 1271

10.3390/bioengineering12111271 | PMID 41301229 Get It

Phonoenterography (PEG) offers a non-invasive and radiation-free technique to assess gastrointestinal activity through acoustic signal analysis. In this feasibility study, 110 high-resolution PEG recordings (44.1 kHz, 16-bit) were acquired from eight healthy individuals, yielding 6314 prominent bowel sound (PBS) segments through automated segmentation. Each event was characterized using a 279-feature acoustic profile comprising Mel-frequency cepstral coefficients (MFCCs), their first-order derivatives (Δ-MFCCs), and six global spectral parameters. After normalization and dimensionality reduction with PCA and UMAP (cosine distance, 35 neighbors, minimum distance = 0.01), five clustering strategies were evaluated. K-Means (k = 5) achieved the most favorable balance between cluster quality (silhouette = 0.60; Calinski–Harabasz = 19,165; Davies–Bouldin = 0.68) and interpretability, consistently identifying five acoustic patterns: single-burst, multiple-burst, harmonic, random-continuous, and multi-modal. Temporal modeling of clustered events further revealed distinct sequential dynamics, with Single-Burst events showing the longest dwell times, random continuous the shortest, and strong diagonal elements in the transition matrix confirming measurable state persistence. Frequent transitions between random continuous and multi-modal states suggested dynamic exchanges between transient and overlapping motility patterns. Together, these findings demonstrate that unsupervised PEG-based analysis can capture both acoustic variability and temporal organization of bowel sounds. This annotation-free approach provides a scalable framework for real-time gastrointestinal monitoring and holds potential for clinical translation in conditions such as postoperative ileus, bowel obstruction, irritable bowel syndrome, and inflammatory bowel disease.
Artificial Intelligence in Postmenopausal Health: From Risk Prediction to Holistic Care
Panjwani, Gianeshwaree Alias Rachna , Maddukuri, Srivarshini , Ansari, Rabiah Aslam, Jain, Samiksha , Chavan, Manisha, Gogula, Naga Sai Akhil Reddy, Yerrapragada, Gayathri, Elangovan, Poonguzhali , Shariff, Mohammed Naveed , Natarajan, T.K. , Janarthanan, Jayarajasekaran, Karrupiah, Shiva Sankari, Gopalakrishnan, Keerthy, Sood, Divyanshi, Arunachalam, Shivaram P. , Natarajan, Thangeswaran , Elangovan, Poonguzhali , Arunachalam, S P , Panjwani, Gianeshwaree Alias Rachna , Shariff, Mohammad Naveed , Ansari, Rabiah Aslam, Yerrapragada, Gayathri

Mayo Clinic

Journal of Clinical Medicine | October 30, 2025 | Volume: 14 | Issue: 21 | Pages: 7651

10.3390/jcm14217651 | PMID 41227046 Get It

Background/Objectives: Menopause, marked by permanent cessation of menstruation, is a universal transition associated with vasomotor, genitourinary, psychological, and metabolic changes. These conditions significantly affect health-related quality of life (HRQoL) and increase the risk of chronic diseases. Despite their impact, timely diagnosis and individualized management are often limited by delayed care, fragmented health systems, and cultural barriers. Methods: This review summarizes current applications of artificial intelligence (AI) in postmenopausal health, focusing on risk prediction, early detection, and personalized treatment. Evidence was compiled from studies using biomarkers, imaging, wearable sensors, electronic health records, natural language processing, and digital health platforms. Results: AI enhances disease prediction and diagnosis, including improved accuracy in breast cancer and osteoporosis screening through imaging analysis, and cardiovascular risk stratification via machine learning models. Wearable devices and natural language processing enable real-time monitoring of underreported symptoms such as hot flushes and mood disorders. Digital technologies further support individualized interventions, including lifestyle modification and optimized medication regimens. By improving access to telemedicine and reducing bias, AI also has the potential to narrow healthcare disparities. Conclusions: AI can transform postmenopausal care from reactive to proactive, offering personalized strategies that improve outcomes and quality of life. However, challenges remain, including algorithmic bias, data privacy, and clinical implementation. Ethical frameworks and interdisciplinary collaboration among clinicians, data scientists, and policymakers are essential for safe and equitable adoption.
Prospects of AI-Powered Bowel Sound Analytics for Diagnosis, Characterization, and Treatment Management of Inflammatory Bowel Disease
Sood, Divyanshi, RIAZ, ZENAB MUHAMMAD, Mikkilineni, Jahnavi, Ravi, Narendra Nath, Chidipothu, Vineeta, Yerrapragada, Gayathri, Poonguzhali, E. , Shariff, Mohammed Naveed , Natarajan, T.K. , Janarthanan, Jayarajasekaran, Asadimanesh, Naghmeh , Karuppiah, Shiva Sankari, Gopalakrishnan, Keerthy, Arunachalam, Shivaram P. , Natarajan, Thangeswaran , Arunachalam, S P , Shariff, Mohammad Naveed

Mayo Clinic

Medical Sciences | October 14, 2025 | Volume: 13 | Issue: 4 | Pages: 230

10.3390/medsci13040230 | PMID 41133513 Get It

Background: This narrative review examines the role of artificial intelligence (AI) in bowel sound analysis for the diagnosis and management of inflammatory bowel disease (IBD). Inflammatory bowel disease (IBD), encompassing Crohn’s disease and ulcerative colitis, presents a significant clinical burden due to its unpredictable course, variable symptomatology, and reliance on invasive procedures for diagnosis and disease monitoring. Despite advances in imaging and biomarkers, tools such as colonoscopy and fecal calprotectin remain costly, uncomfortable, and impractical for frequent or real-time assessment. Meanwhile, bowel sounds—an overlooked physiologic signal—reflect underlying gastrointestinal motility and inflammation but have historically lacked objective quantification. With recent advances in artificial intelligence (AI) and acoustic signal processing, there is growing interest in leveraging bowel sound analysis as a novel, non-invasive biomarker for detecting IBD, monitoring disease activity, and predicting disease flares. This approach holds the promise of continuous, low-cost, and patient-friendly monitoring, which could transform IBD management. Objectives: This narrative review assesses the clinical utility, methodological rigor, and potential future integration of artificial intelligence (AI)-driven bowel sound analysis in inflammatory bowel disease (IBD), with a focus on its potential as a non-invasive biomarker for disease activity, flare prediction, and differential diagnosis. Methods: This manuscript reviews the potential of AI-powered bowel sound analysis as a non-invasive tool for diagnosing, monitoring, and managing inflammatory bowel disease (IBD), including Crohn’s disease and ulcerative colitis. Traditional diagnostic methods, such as colonoscopy and biomarkers, are often invasive, costly, and impractical for real-time monitoring. The manuscript explores bowel sounds, which reflect gastrointestinal motility and inflammation, as an alternative biomarker by utilizing AI techniques like convolutional neural networks (CNNs), transformers, and gradient boosting. We analyze data on acoustic signal acquisition (e.g., smart T-shirts, smartphones), signal processing methodologies (e.g., MFCCs, spectrograms, empirical mode decomposition), and validation metrics (e.g., accuracy, F1 scores, AUC). Studies were assessed for clinical relevance, methodological rigor, and translational potential. Results: Across studies enrolling 16–100 participants, AI models achieved diagnostic accuracies of 88–96%, with AUCs ≥ 0.83 and F1 scores ranging from 0.71 to 0.85 for differentiating IBD from healthy controls and IBS. Transformer-based approaches (e.g., HuBERT, Wav2Vec 2.0) consistently outperformed CNNs and tabular models, yielding F1 scores of 80–85%, while gradient boosting on wearable multi-microphone recordings demonstrated robustness to background noise. Distinct acoustic signatures were identified, including prolonged sound-to-sound intervals in Crohn’s disease (mean 1232 ms vs. 511 ms in IBS) and high-pitched tinkling in stricturing phenotypes. Despite promising performance, current models remain below established biomarkers such as fecal calprotectin (~90% sensitivity for active disease), and generalizability is limited by small, heterogeneous cohorts and the absence of prospective validation. Conclusions: AI-powered bowel sound analysis represents a promising, non-invasive tool for IBD monitoring. However, widespread clinical integration requires standardized data acquisition protocols, large multi-center datasets with clinical correlates, explainable AI frameworks, and ethical data governance. Future directions include wearable-enabled remote monitoring platforms and multi-modal decision support systems integrating bowel sounds with biomarker and symptom data. This manuscript emphasizes the need for large-scale, multi-center studies, the development of explainable AI frameworks, and the integration of these tools within clinical workflows. Future directions include remote monitoring using wearables and multi-modal systems that combine bowel sounds with biomarkers and patient symptoms, aiming to transform IBD care into a more personalized and proactive model.
Metrics for Phonoenterogram Analytics Towards AI Powered Diagnosis of Bowel Diseases: Feasibility Meal Study in a Healthy Subject
Gopalakrishnan, Keerthy, Asadimanesh, Naghmeh, Sood, Divyanshi, Rapolu, Swetha, Lee, Jieun , Patel, Bhumi, Arunachalam, S P , Mohan, Anmol , Patel, Bhumi, Dilmaghani, Saam , Arunachalam, Shivaram P.

Mayo Clinic

2025 IEEE International Conference on Electro Information Technology (eIT) | August 12, 2025 | Volume: No volume available | Issue: No issue available | Pages: 1-6

10.1109/eit64391.2025.11103636 Get It

A Novel You Only Listen Once (YOLO) Deep Learning Model for Automatic Prominent Bowel Sounds Detection: Feasibility Study in Healthy Subjects
Kalahasty, Rohan, Yerrapragada, Gayathri, Lee, Jieun , Gopalakrishnan, Keerthy, Kaur, Avneet , Muddaloor, Pratyusha, Sood, Divyanshi, Parikh, Charmy, Gohri, Jay , Panjwani, Gianeshwaree Alias Rachna , Asadimanesh, Naghmeh, Ansari, Rabiah Aslam, Rapolu, Swetha, Karuppiah, Shiva Sankari, Dasari, Vijaya M., Helgeson, Scott A. , Arunachalam, Shivaram P. , Helgeson, Scott A , Arunachalam, S P , Panjwani, Gianeshwaree Alias Rachna , Yerrapragada, Gayathri, Ansari, Rabiah Aslam, Elangovan, Poonguzhali , Akshintala, Venkata S.

Mayo Clinic

Sensors | August 4, 2025 | Volume: 25 | Issue: 15 | Pages: 4735

10.3390/s25154735 | PMID 40807899 Get It

Accurate diagnosis of gastrointestinal (GI) diseases typically requires invasive procedures or imaging studies that pose the risk of various post-procedural complications or involve radiation exposure. Bowel sounds (BSs), though typically described during a GI-focused physical exam, are highly inaccurate and variable, with low clinical value in diagnosis. Interpretation of the acoustic characteristics of BSs, i.e., using a phonoenterogram (PEG), may aid in diagnosing various GI conditions non-invasively. Use of artificial intelligence (AI) and improvements in computational analysis can enhance the use of PEGs in different GI diseases and lead to a non-invasive, cost-effective diagnostic modality that has not been explored before. The purpose of this work was to develop an automated AI model, You Only Listen Once (YOLO), to detect prominent bowel sounds that can enable real-time analysis for future GI disease detection and diagnosis. A total of 110 2-minute PEGs sampled at 44.1 kHz were recorded using the Eko DUO® stethoscope from eight healthy volunteers at two locations, namely, left upper quadrant (LUQ) and right lower quadrant (RLQ) after IRB approval. The datasets were annotated by trained physicians, categorizing BSs as prominent or obscure using version 1.7 of Label Studio Software®. Each BS recording was split up into 375 ms segments with 200 ms overlap for real-time BS detection. Each segment was binned based on whether it contained a prominent BS, resulting in a dataset of 36,149 non-prominent segments and 6435 prominent segments. Our dataset was divided into training, validation, and test sets (60/20/20% split). A 1D-CNN augmented transformer was trained to classify these segments via the input of Mel-frequency cepstral coefficients. The developed AI model achieved area under the receiver operating curve (ROC) of 0.92, accuracy of 86.6%, precision of 86.85%, and recall of 86.08%. This shows that the 1D-CNN augmented transformer with Mel-frequency cepstral coefficients achieved creditable performance metrics, signifying the YOLO model’s capability to classify prominent bowel sounds that can be further analyzed for various GI diseases. This proof-of-concept study in healthy volunteers demonstrates that automated BS detection can pave the way for developing more intuitive and efficient AI-PEG devices that can be trained and utilized to diagnose various GI conditions. To ensure the robustness and generalizability of these findings, further investigations encompassing a broader cohort, inclusive of both healthy and disease states are needed.
A Novel 3D Convolutional Neural Network-Based Deep Learning Model for Spatiotemporal Feature Mapping for Video Analysis: Feasibility Study for Gastrointestinal Endoscopic Video Classification
Dhar, Mrinal Kanti , Deb, Mou, Gopalakrishnan, Keerthy, Sood, Divyanshi, Kaur, Avneet , Parikh, Charmy, Rapolu, Swetha, Panjwani, Gianeshwaree Alias Rachna , Ansari, Rabiah Aslam, Asadimanesh, Naghmeh, Karuppiah, Shiva Sankari, Helgeson, Scott A. , Arunachalam, Shivaram P. , Panjwani, Gianeshwaree Alias Rachna , Helgeson, Scott A , Arunachalam, S P , Elangovan, Poonguzhali , Ansari, Rabiah Aslam, Akshintala, Venkata S.

Mayo Clinic

Journal of Imaging | July 18, 2025 | Volume: 11 | Issue: 7 | Pages: 243

10.3390/jimaging11070243 | PMID 40710629 Get It

Accurate analysis of medical videos remains a major challenge in deep learning (DL) due to the need for effective spatiotemporal feature mapping that captures both spatial detail and temporal dynamics. Despite advances in DL, most existing models in medical AI focus on static images, overlooking critical temporal cues present in video data. To bridge this gap, a novel DL-based framework is proposed for spatiotemporal feature extraction from medical video sequences. As a feasibility use case, this study focuses on gastrointestinal (GI) endoscopic video classification. A 3D convolutional neural network (CNN) is developed to classify upper and lower GI endoscopic videos using the hyperKvasir dataset, which contains 314 lower and 60 upper GI videos. To address data imbalance, 60 matched pairs of videos are randomly selected across 20 experimental runs. Videos are resized to 224 × 224, and the 3D CNN captures spatiotemporal information. A 3D version of the parallel spatial and channel squeeze-and-excitation (P-scSE) is implemented, and a new block called the residual with parallel attention (RPA) block is proposed by combining P-scSE3D with a residual block. To reduce computational complexity, a (2 + 1)D convolution is used in place of full 3D convolution. The model achieves an average accuracy of 0.933, precision of 0.932, recall of 0.944, F1-score of 0.935, and AUC of 0.933. It is also observed that the integration of P-scSE3D increased the F1-score by 7%. This preliminary work opens avenues for exploring various GI endoscopic video-based prospective studies.
Functional Lumen Imaging Probe as Part of Multimodality Assessment of Esophagogastric Junction Opening Is Important in Longitudinal Follow‐Up of Patients With Treated Achalasia
Kamboj, Amrit K. , Sood, Shubham , Truong, Brandon , Song, Louis M. Wong Kee , Wells, Michael , Wigle, Dennis A. , Codipilly, Don C. , Snyder, Diana L. , Alexander, Jeffrey A., Leggett, Cadman L. , Lennon, Ryan J. , Koop, Andree , Vela, Marcelo F. , Wigle, Dennis, Vela, Marcelo F , Leggett, Cadman L , Alexander, Jeffrey A., Ravi, Karthik

Mayo Clinic

Neurogastroenterology & Motility | July 15, 2025 | Volume: 37 | Issue: 12 | Pages: No page available

10.1111/nmo.70121 | PMID 40660739 Get It

ABSTRACT Background Functional lumen imaging probe (FLIP) utility is established in treatment‐naïve achalasia but less clear following lower esophageal sphincter (LES) directed therapy. Methods Achalasia patients with LES directed therapy across three tertiary care centers between 2017 and 2024 with post‐treatment FLIP and timed barium esophagram (TBE) were retrospectively identified. Reduced esophagogastric junction (EGJ) opening was defined by distensibility index (DI) < 2 mm 2 /mmHg and diameter < 12 mm. Abnormal emptying on TBE was defined as column height ≥ 5 cm at 5 min and/or retained tablet. Eckardt scores ≤ 3 defined clinical response. Key Results The study included 222 patients (46% peroral endoscopic myotomy, 46% laparoscopic Heller myotomy, 8% pneumatic dilation) with a median of 1.4 years to post‐treatment TBE/FLIP. Abnormal emptying on TBE was associated with a narrower median EGJ diameter (13.2 vs. 14.8 mm, p = 0.008), a greater frequency of EGJ diameter < 12 mm (36% vs. 21%, p = 0.012), and a smaller change in EGJ diameter (+4.6 vs. +8.6 mm, p = 0.002). Abnormal emptying on TBE occurred more frequently in patients with EGJ DI < 2 mm 2 /mmHg (8.5% vs. 2.6%, p = 0.052), but was not associated with median EGJ DI (4.5 vs. 5.1 mm 2 /mmHg, p = 0.29) nor median change in EGJ DI (+2.9 vs. +3.9 mm 2 /mmHg, p = 0.25). Patients with reduced EGJ DI or EGJ diameter more often had abnormal TBE (37% vs. 22%, p = 0.012). Only the change in DI (+3.8 vs. +1.5 mm 2 /mmHg, p = 0.012) and diameter (+8.2 vs. +1.6 mm, p = 0.002) on FLIP was associated with a clinical response based on Eckardt ≤ 3. Conclusions and Inferences FLIP following achalasia therapy generally correlates with TBE, although discrepant findings are not uncommon. In particular, FLIP EGJ‐diameter has a strong association with esophageal emptying on TBE. Both TBE and FLIP have limited association with clinical response based on Eckardt, with change in DI and diameter on FLIP most strongly associated. Consequently, FLIP as part of multimodal assessment appears useful in the longitudinal follow‐up of treated achalasia.
Call to action—Pediatric MASLD requires immediate attention to curb health crisis
Hartmann, Phillipp , Hassan, Sara , Kehar, Mohit , Mysore, Krupa R. , Mauney, Erin E. , Nonga, Dieudonne, Karjoo, Sara , Sood, Shilpa , Tou, Andrea , Brichta, Christine, Herdes, Rachel E. , Garner, Donna, Rinella, Mary E., Noureddin, Mazen , Younossi, Zobair M. , Kohut, Taisa , Ramirez, Charina M. , Xanthakos, Stavra A. , Vos, Miriam B., Ibrahim, Samar H. , Panganiban, Jennifer , Rinella, Mary E. , Mysore, Krupa R , Karjoo, Sara , Sood, Shilpa , Ibrahim, Samar H , Rinella, Mary , Mouzaki, Marialena , Nonga, Dieudonne , Brichta, Christine E. , Pai, Nikhil , Allen, Alina M. , Sanyal, Arun J. , Kohli, Rohit , Schwimmer, Jeffrey B.

Mayo Clinic

Hepatology | June 23, 2025 | Volume: 82 | Issue: 5 | Pages: 1341-1351

10.1097/hep.0000000000001440 | PMID 40550108 Get It

Pediatric metabolic dysfunction–associated steatotic liver disease (MASLD) has become more prevalent on a global scale over the last decades and is associated with significant comorbidities in childhood and a 40-fold higher risk of early mortality in young adulthood. MASLD has now become the leading indication for liver transplantation in young adults in the United States. However, pediatric MASLD is still perceived as an indolent condition by many patients, families, and clinicians. In this Call to Action, we aim to raise awareness of pediatric MASLD as a public health crisis. Herein, we describe insufficient screening and disease staging practices, and a lack of accurate non-invasive tests and effective pharmacotherapy, both stemming from a paucity of multicenter clinical trials in pediatric MASLD. We provide clear steps to address this public health emergency by promoting awareness campaigns, educating and empowering patients and families, addressing barriers including access to care, nutritional and exercise support programs, establishing multidisciplinary care, launching community initiatives, and conducting clinical trials in pediatric MASLD for an age-based evaluation of novel diagnostic and therapeutic options. We conclude by highlighting the urgent need for comprehensive public health policies to control the tide of pediatric MASLD and call upon stakeholders to act now.