Citations

Clear

32 citation(s) found for "Leoni, Juan Carlos".

Short-Term Outcomes of Heart Transplant Patients Bridged with Impella 5.5 Ventricular Assist Device
Haddad, Osama , Sareyyüpoğlu, Başar , Goswami, Rohan , Bitargil, Macit , Patel, Parag C. , Jacob, Samuel , Ahmed, Magdy M. El‐Sayed , Leoni, Juan , Yip, Daniel , Landolfo, Kevin , Leoni Moreno, Juan Carlos, Pham, Si M. , Goswami, Rohan , Leoni, Juan Carlos

Mayo Clinic

ESC Heart Failure | May 3, 2023 | Volume: 10 | Issue: 4 | Pages: 2298-2306

10.1002/ehf2.14391 | PMID 37137732 Get It

Abstract Aims We sought to investigate the outcomes of heart transplant patients supported with Impella 5.5 temporary mechanical circulatory support. Methods and results Patient demographics, perioperative data, hospital timeline, and haemodynamic parameters were followed during initial admission, Impella support, and post-transplant period. Vasoactive-inotropic score, primary graft failure, and complications were recorded. Between March 2020 and March 2021, 16 advanced heart failure patients underwent Impella 5.5 temporary left ventricular assist device support through axillary approach. Subsequently, all these patients had heart transplantation. All patients were either ambulatory or chair bound during their temporary mechanical circulatory support until heart transplantation. Patients were kept on Impella support median of 19 days (3–31) with the median lactate dehydrogenase level of 220 (149–430). All Impella devices were removed during heart transplantation. During Impella support, patients had improved renal function with median creatinine serum level of 1.55 mg/dL decreased to 1.25 (P = 0.007), pulmonary artery pulsatility index scores increased from 2.56 (0.86–10) to 4.2 (1.3–10) (P = 0.048), and right ventricular function improved (P = 0.003). Patients maintained improved renal function and favourable haemodynamics after their heart transplantation as well. All patients survived without any significant morbidity after their heart transplantation. Conclusions Impella 5.5 temporary left ventricular assist device optimizes care of heart transplant recipients providing superior haemodynamic support, mobility, improved renal function, pulmonary haemodynamics, and right ventricular function. Utilizing Impella 5.5 as a direct bridging strategy to heart transplantation resulted in excellent outcomes.
Non-invasive detection of cardiac allograft rejection among heart transplant recipients using an electrocardiogram based deep learning model
Adedinsewo, Demilade , Hardway, Heather D , Morales-Lara, Andrea Carolina , Wieczorek, Mikolaj A. , Douglass, Erika J. , Dangott, Bryan, Nakhleh, Raouf E. , Narula, Tathagat , Patel, Parag C. , Lyle, Melissa , Heckman, Alexander , Leoni-Moreno, Juan Carlos, Steidley, D. Eric , Hardaway, Brian , Abbas, Mohsin, Friedman, Paul A. , Carter, Rickey E. , Yamani, Mohamad H. , Douglass, Erika J , Dangott, Bryan J, Narula, Tathagat , Heckman, Alexander J, Leoni-Moreno, Juan C, Attia, Zachi I , Lopez-Jimenez, Francisco , Yamani, Mohamad, Carter, Rickey E , Adedinsewo, Demilade A , Hardway, Heather , Johnson, Patrick W. , Goswami, Rohan , Arsanjani, Reza , Behfar, Atta , Attia, Zachi I. , López-Jiménez, Francisco , Noseworthy, Peter A.

Mayo Clinic

European Heart Journal - Digital Health | January 13, 2023 | Volume: 4 | Issue: 2 | Pages: 71-80

10.1093/ehjdh/ztad001 | PMID 36974261 Get It

Abstract Aims Current non-invasive screening methods for cardiac allograft rejection have shown limited discrimination and are yet to be broadly integrated into heart transplant care. Given electrocardiogram (ECG) changes have been reported with severe cardiac allograft rejection, this study aimed to develop a deep-learning model, a form of artificial intelligence, to detect allograft rejection using the 12-lead ECG (AI-ECG). Methods and results Heart transplant recipients were identified across three Mayo Clinic sites between 1998 and 2021. Twelve-lead digital ECG data and endomyocardial biopsy results were extracted from medical records. Allograft rejection was defined as moderate or severe acute cellular rejection (ACR) based on International Society for Heart and Lung Transplantation guidelines. The extracted data (7590 unique ECG-biopsy pairs, belonging to 1427 patients) was partitioned into training (80%), validation (10%), and test sets (10%) such that each patient was included in only one partition. Model performance metrics were based on the test set (n = 140 patients; 758 ECG-biopsy pairs). The AI-ECG detected ACR with an area under the receiver operating curve (AUC) of 0.84 [95% confidence interval (CI): 0.78–0.90] and 95% (19/20; 95% CI: 75–100%) sensitivity. A prospective proof-of-concept screening study (n = 56; 97 ECG-biopsy pairs) showed the AI-ECG detected ACR with AUC = 0.78 (95% CI: 0.61–0.96) and 100% (2/2; 95% CI: 16–100%) sensitivity. Conclusion An AI-ECG model is effective for detection of moderate-to-severe ACR in heart transplant recipients. Our findings could improve transplant care by providing a rapid, non-invasive, and potentially remote screening option for cardiac allograft function.
A review of transthyretin cardiac amyloidosis
Leoni, Juan , Chirilă, Răzvan M. , Jhawar, Nikita , Moreno, Juan Carlos Leoni, Chirilă, Răzvan , Leoni, Juan Carlos

Mayo Clinic

Romanian Journal of Internal Medicine | October 21, 2022 | Volume: 61 | Issue: 1 | Pages: 28-34

10.2478/rjim-2022-0018 | PMID 36278951 Get It

Abstract Transthyretin cardiac amyloidosis is a progressive disease known to cause heart failure, conduction anomalies, and arrythmias. Due to poor outcomes and mortality from severe cardiomyopathy, prevalence and incident rates are often underreported. As global longevity is increasing and rates of amyloidosis are also increasing, there is a need to improve diagnostic and therapeutic interventions. Previously, symptom management and transplantation were the mainstay of treatment for heart failure symptoms, but studies using RNAi and siRNA technologies have shifted the paradigm of therapeutic strategy in amyloid cardiomyopathy management. Additionally, early detection and clinical monitoring with numerous imaging and non-imaging techniques are being increasingly investigated. Here, we review the epidemiology, pathophysiology, diagnosis, and management of transthyretin amyloid cardiomyopathy.
MERGING ADVANCE TECHNOLOGY TO IMPROVE OUTCOMES IN HEART TRANSPLANTATION - A CASE REPORT
Jang, Jin Sung , Pham, S, JM, Ruiz, PC, Patel, JC, Leoni, DS, Yip, JN, Nativi, Landolfo, K, Sareyyupoglu, B, RM, Goswami, Pham, S., Ruiz, Jose , Patel, Parag C. , Leoni, Juan Carlos , Yip, Daniel , Nativí, Jose, Landolfo, Kevin , Sareyyüpoğlu, Başar , Goswami, Rohan

Mayo Clinic

INTERNATIONAL JOURNAL OF SCIENTIFIC RESEARCH | August 5, 2022 | Volume: No volume available | Issue: No issue available | Pages: 26-28

10.36106/ijsr/5822267 Get It

One of the signicant obstacles to donor heart utilization is that increasingly prolonged cold ischemic times are associated with worsened short- and long-term outcomes. As a result, most transplant centers aim to limit cold ischemic times to less than four hours. The TransMedics Organ Care System (OCS) (Trans Medics, Andover MA) is a portable ex vivo perfusion system designed to store a donor heart in a beating, metabolically active state, until it reaches the recipient, thereby allowing extended time outside the body while minimizing the effects of cold storage. We present a case of a heart transplant recipient supported with the Impella 5.5 as a bridge to transplantation who received a donation after circulatory death (DCD) heart supported by OCS. To our knowledge, this is the rst report of such a case.
REN3: Percutaneous Axillary Temporary Mechanical Support Improves Renal Function Prior To Heart Transplantation In Patients With Chronic Kidney Disease
Jang, Ji-Min, Nativí, Jose, Patel, Parag C. , Leoni, Juan , Yip, Daniel , Sareyyüpoğlu, Başar , Landolfo, Kevin , Leoni, Juan Carlos , Pham, Si M. , Goswami, Rohan

Mayo Clinic

ASAIO Journal | June 16, 2022 | Volume: 68 | Issue: Supplement 2 | Pages: 89-89

10.1097/01.mat.0000841208.11864.3b Get It

Packing the donor heart: Is SherpaPak cold preservation technique safer compared to ice cold storage
Bitargil, Macit , Haddad, Osama , Pham, Si M. , Garg, Neha , Jacob, Samuel , Ahmed, Magdy M. El‐Sayed , Landolfo, Kevin , Patel, Parag C. , Goswami, Rohan , Leoni, Juan , Yip, Daniel , Sareyyüpoğlu, Başar , El-Sayed Ahmed, Magdy M , Goswami, Rohan M , Leoni, Juan Carlos , Yip, Daniel S , Patel, Parag C. , Pham, Si , Garg, Neha , Goswami, Rohan

Mayo Clinic

Clinical Transplantation | May 11, 2022 | Volume: 36 | Issue: 8 | Pages: No page available

10.1111/ctr.14707 | PMID 35543679 Get It

AbstractIntroductionThe present study aimed to compare the clinical outcomes of heart transplant patients whose donor hearts were preserved with the SherpaPak controlled cold organ system versus the conventional ice storage technique.MethodsAll patients undergoing heart transplantation at our center between January 2019 and April 2021 were divided into two groups according to the technique used during donor heart preservation and transport. The first group consisted of 34 SherpaPak controlled temperature preservation patients, and the second group consisted of 47 patients where the conventional three bags and ice technique was utilized during organ transportation. The two groups were compared based on demographics, operative details, and postoperative outcomes.ResultsThere were no significant differences between the groups regarding Vasoactive Inotropic Score (VIS), Primary Graft Dysfunction (PGD), and the need for a transient pacer. However, the VIS, PGD, and pacing trends were lower in the SherpaPak patients even though the total ischemic and cardiopulmonary bypass times were significantly longer. Furthermore, SherpaPak patients exhibited a shorter stay in the ICU with no severe PGD and mortality.ConclusionThe SherpaPak donor heart preservation provides safe outcomes in heart transplant patients. Further research is needed to utilize this method for longer durations of ischemic time and expand travel distances for organ transportation.
Controlled temperatures in cold preservation provides safe heart transplantation results
Bitargil, Macit , Haddad, Osama , Pham, Si M. , Goswami, Rohan , Patel, Parag C. , Jacob, Samuel , Ahmed, Magdy M. El‐Sayed , Leoni, Juan , Yip, Daniel , Landolfo, Kevin , Sareyyüpoğlu, Başar , Goswami, Rohan M, Leoni Moreno, Juan Carlos, Yip, Daniel S, Pham, Si , Goswami, Rohan , Leoni, Juan Carlos

Mayo Clinic

Journal of Cardiac Surgery | January 21, 2022 | Volume: 37 | Issue: 4 | Pages: 732-738

10.1111/jocs.16243 | PMID 35060167 Get It

A Comparison of Von Willebrand Factor Indexes in Heartmate II Compared to Heartware Left Ventricular Assist Devices
Gupta, Bhanu , Leoni, Juan , Patel, Parag C. , Blackshear, Joseph L., Leoni, Juan Carlos , Chen, Dong

Mayo Clinic

Blood | October 12, 2019 | Volume: 126 | Issue: 23 | Pages: 2306-2306

10.1182/blood.v126.23.2306.2306 Get It

Abstract Background: Von Willebrand factor (VWF) is a multimeric glycoprotein synthesized in endothelium and megakaryocytes. Elevated total VWF antigen has been associated with arterial thrombosis, while in patients with left ventricular assist devices (LVAD), loss of high molecular weight multimers is associated with spontaneous bleeding. We hypothesized that the lower rotational speed of the Heartware LVAD would be associated with less severe disruption of VWF. Methods: A total of 22 patients were included. We compared samples from a) 17 patients with Heartmate II LVAD (HM II), 76% male, median age 67 (54-73) years, 24% non-white, 45 (33-59) months after implant, with b) 5 patients with Heartware (HW) LVAD, all male, age 64 (59-65) years, 20% non-white, 27 (14-29) months after implant. All patients received warfarin. All HW patients took aspirin, while 82% of HM II patients took aspirin. Samples were analyzed for VWF antigen, activity, platelet function analyzer-100 collagen adenosine diphosphate closure time (PFA) and VWF multimers by gel electrophoresis. Multimers were assessed qualitatively and quantitatively by dividing mers > 15 by mers 2-15 (multimer ratio) and with a normalized multimer ratio (multimer ratio of patient / normal plasma control from the same gel). Results: Although flow rates did not differ significantly between HM II and HW, 5.2 (4.6-6.5) versus 4.3 (4.2-5.4) liters per minute respectively, rotational speeds were very different, mean 9472 versus 2680 rpms, p<0.0001). There were no differences in hemoglobin, hematocrit, or platelet count at the time of sampling. Qualitative VWF multimers were abnormal in all patients, and PFA was non-clotting in 88% of HM II patients and 80% of HW patients. VWF activity to antigen ratio was not different: HM II 0.68 (0.63-0.74) versus HW 0.70 (0.63-0.71). However, VWF antigen was significantly higher in HM II patients, 199 (174-227) compared to HW, 139 (122-160), p=0.039 and the normalized VWF multimer ratio was significantly lower, suggesting greater loss of high molecular weight multimers in HM II, 0.43 (0.41-0.48) compared to HW, 0.53 (0.48-0.56), p=0.0025 (figure). Conclusion: The lower rotational speed associated with the Heartware LVAD appears to produce less elevation of VWF antigen, and slightly less loss of VWF high molecular weight multimers compared to the Heartmate II LVAD. Additional studies are needed to describe whether or not lower pump thrombosis rates and rates of spontaneous bleeding are associated with these differences. Figure 1. Figure 1. Disclosures No relevant conflicts of interest to declare.
Extracorporeal membrane oxygenation as a salvage therapy for patients with severe primary graft dysfunction after heart transplant
Jacob, Samuel , Lima, Brian , Gonzalez‐Stawinski, Gonzalo V. , Ahmed, Magdy M. El‐Sayed , Patel, Parag C. , Belli, Erol, Makey, Ian A. , Thomas, Mathew , Landolfo, Kevin , Landolfo, Carolyn, Leoni, Juan , Yip, Daniel , Thomas, Mathew , Belli, Erol V, Leoni Moreno, Juan Carlos, Yip, Daniel S, Pham, Si M. , Thomas, Mathew , Thomas, Mathew, Leoni, Juan Carlos

Mayo Clinic

Clinical Transplantation | March 14, 2019 | Volume: 33 | Issue: 5 | Pages: No page available

10.1111/ctr.13538 | PMID 30870577 Get It

AbstractBackgroundSevere primary graft dysfunction (PGD) is the leading cause of early death after heart transplant.AimTo examine the outcomes of heart transplant recipients who received venoarterial extracorporeal membrane oxygenation (VA‐ECMO) for severe PGD.MethodsWe reviewed electronic health records of adult patients who underwent heart transplant from November 2005 through June 2015. We defined severe PGD according to International Society for Heart and Lung Transplantation consensus statements.ResultsOf 1030 heart transplant patients, 31 (3%) had severe PGD and required VA‐ECMO. The mean (range) age was 59 (43‐69) years. Fifteen patients (48%) underwent prior sternotomy and 10 (32%) received a left ventricular assist device as a bridge to transplant. Severe PGD manifested as failure to wean from cardiopulmonary bypass in 20 patients (65%) and as severe hemodynamic instability in the immediate postoperative period in 10 (32%), including cardiac arrest in 3 (10%). Twenty‐five patients (81%) were successfully weaned from VA‐ECMO, and 19 (61%) were discharged; the other 12 (39%) died.ConclusionsAlthough VA‐ECMO is a common method for providing mechanical circulatory support to patients with PGD, multicenter studies are needed to assess factors associated with successful outcomes and improved survival of these patients.
An Elderly Man With a Pacemaker and a Recent Fall
Morales-Lara, Andrea Carolina , Leoni, Juan , Morales-Lara, A Carolina, Leoni, Juan C, Kusumoto, Fred M, Leoni, Juan Carlos , Kusumoto, Fred

Mayo Clinic

JAMA Cardiology | August 25, 2017 | Volume: 2 | Issue: 10 | Pages: 1161

10.1001/jamacardio.2017.1932 | PMID 28832863 Get It