Citations

Clear

30 citation(s) found for "Jokerst, Clinton".

CPI Physics in Imaging Special Edition Module
Jokerst, Clinton, Sharma, Puneet , Vedantham, Srinivasan , Covington, Matthew F. , Eisenbrey, John Robert , Saranathan, Manojkumar

Mayo Clinic

Continuous Professional Improvement | March 25, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.54057/cpi.ph2022 Get It

Safety of magnetic resonance imaging in patients with cardiac implantable electronic devices with generator and lead(s) brand mismatch
Minaskeian, Nareg , Hajnal, Sofia Pannunzio, Liu, Michael B. , Klooster, Lindsay, Devick, Katrina L. , Schwartz, Linda, Jokerst, Clinton, Sorajja, Dan , Scott, Luis, Hajnal, Sofia P, Klooster, Lindsay M, Scott, Luis Rp, Schwartz, Linda

Mayo Clinic

Journal of Applied Clinical Medical Physics | January 23, 2022 | Volume: 23 | Issue: 3 | Pages: No page available

10.1002/acm2.13520 | PMID 35066975 Get It

AbstractMagnetic resonance imaging (MRI) is a valuable imaging modality for the assessment of both cardiac and non‐cardiac structures. With a growing population of patients with cardiovascular implantable electronic devices (CIEDs), 50%–75% of these patients will need an MRI. MRI‐conditional CIEDs have demonstrated safety of MRI scanning with such devices, yet non‐conditional devices such as hybrid CIEDs which have generator and lead brand mismatch may pose a safety risk. In this retrospective study, we examined the outcomes of patients with hybrid CIEDs undergoing MRI compared to those patients with non‐hybrid CIEDs. A total of 349 patients were included, of which 24 patients (7%) had hybrid CIEDs. The primary endpoint was the safety of MRI for patients with hybrid CIEDs as compared to those with non‐hybrid devices, measured by the rate of adverse events, including death, lead or generator failure needing immediate replacement, loss of capture, new onset arrhythmia, or power‐on reset. Secondary endpoints consisted of pre‐ and post‐MRI changes of decreased P‐wave or R‐wave sensing by ≥50%, changes in pacing lead impedance by ≥50 ohms, increase in pacing thresholds by ≥ 0.5 V at 0.4 ms, and decreasing battery voltage of ≥ 0.04 V. The primary endpoint of any adverse reaction was present in 1 (4.2%) patient with a hybrid device, and consistent of atrial tachyarrhythmia, and in 10 (3.1%) patients with a non‐hybrid device, and consisted of self‐limited atrial and non‐sustained ventricular arrhythmias; this was not statistically significant. No significant differences were found in the secondary endpoints. This study demonstrates that MRI in patients with hybrid CIEDs does not result in increased patient risk or significant device changes when compared to those patients who underwent MRI with non‐hybrid CIEDs.
Editorial for “Short‐Term Repeatability of In Vivo Cardiac Intravoxel Incoherent Motion (IVIM) Tensor Imaging in Healthy Human Volunteers”
Zhou, Yuxiang , Jokerst, Clinton, Panda, Anshuman , Zhou, Yuxiang

Mayo Clinic

Journal of Magnetic Resonance Imaging | November 19, 2021 | Volume: 55 | Issue: 6 | Pages: 1853-1854

10.1002/jmri.28001 | PMID 34797000 Get It

Comparison of echocardiographic parameters with cardiac magnetic resonance imaging in the assessment of right ventricular function
Agasthi, Pradyumna , Siegel, Robert J. , Pujari, Sai Harika , Mookadam, Farouk , Venepally, Nithin R. , Wang, Panwen , Marcotte, François , Semkiv, Oksana I., Fath, Ayman R. , Jokerst, Clinton, Arsanjani, Reza , Ashraf, Hasan , Allam, Mohamed N A, Arsanjani, Reza , Chao, Chieh‐Ju , Mookadam, Farouk , Ashraf, Hasan, Brown, Lisa, Allam, Mohamed

Mayo Clinic

Echocardiography | October 4, 2020 | Volume: 37 | Issue: 11 | Pages: 1792-1802

10.1111/echo.14877 | PMID 33012034 Get It

AbstractIntroductionThe right ventricle (RV) strain measured by speckle tracking (RVS) is an echocardiographic parameter used to assess RV function. We compared RVS to RV fractional area change (FAC%), tricuspid annular plane systolic excursion (TAPSE) and Doppler tissue imaging‐derived peak systolic velocity (Sʹ) in the assessment of right ventricular (RV) systolic function measured using cardiac magnetic resonance imaging (MRI).MethodsWe enrolled consecutive patients who underwent cardiac MRI between Jan 2012 and Dec 2017 and a transthoracic echocardiogram (TTE) within 1 month of the MRI with no interval event. Baseline clinical characteristics and MRI parameters were extracted from chart review. Echocardiographic parameters were measured prospectively. TTE parameters including RVS, TAPSE, Sʹ, and FAC% were tested for accuracy to identify impaired RV EF (EF < 45% & <30%) using receiver operator curves.ResultsThe study cohort included 500 patients with mean age 55 years ± 18 and peak tricuspid regurgitation velocity 2.7 ± 1.4 m/s. The area under ROC for RVS was 0.69 (95% CI 0.63–0.75) and 0.78 (95% CI 0.70–0.88) to predict RVEF < 45% & RVEF < 30%, respectively. The RV FAC% had second highest accuracy of predicting RVEF among all the TTE parameters tested in study.ConclusionRight ventricular strain is the most accurate echocardiographic method to detect impaired right ventricular systolic function when using MRI as the gold standard.
A Unique Compensatory Mechanism for Total Pulmonary Vein Occlusion Post Atrial Fibrillation Catheter Ablation Visualized by Multimodality Imaging
Fath, Ayman R. , Aglan, Amro , Scott, Luis R. , Jokerst, Clinton, Narayanasamy, Hemalatha , Mookadam, Farouk , Mihyawi, Nawfal, Venepally, Nithin R. , Konduru, Sudheer, Arsanjani, Reza , Arsanjani, Reza

Mayo Clinic

Case Reports in Cardiology | September 24, 2020 | Volume: 2020 | Issue: No issue available | Pages: 1-4

10.1155/2020/9673958 | PMID 33029433 Get It

Pulmonary vein (PV) stenosis is a rare and serious complication of radiofrequency catheter ablation (RFCA) for atrial fibrillation. However, it can be asymptomatic or mildly symptomatic depending on the severity of the stenosis and the development of compensatory mechanisms. This study provides a detailed description and visualization of a unique type of venous collaterals that bypass the PV stenosis and drain directly in the left atrium alleviating PV stenosis sequelae. This study reports a case of a 61-year-old male who presented with mild dyspnea and fatigue 3 years post atrial fibrillation RFCA. After a thorough evaluation of the case, a redo-ablation was planned. As a part of the preablation workup, a transesophageal echocardiography (TEE), a ventilation-perfusion (V/Q) scan of the lungs, and a chest computed tomography angiogram (CTA) were performed. The TEE revealed total obstruction of the left superior PV, with no color Doppler flow detected. It also showed evidence of multiple collateral flows at the os of the left superior PV. The V/Q scan showed a large perfusion defect involving the entire left upper lobe consistent with a compromised left upper PV flow. The CTA with 3D volume rendering revealed the total occlusion of the left superior PV at its ostium. Moreover, the scan confirmed the pulmonary venous drainage via small collateral channels that was suggested by the TEE.
Multimodality Imaging Demonstrating an Apical Variant Hypertrophic Cardiomyopathy in an Uncommon Pentad
Fath, Ayman R. , Jokerst, Clinton, Aglan, Amro , Mihyawi, Nawfal, Mookadam, Farouk

Mayo Clinic

Journal of Investigative Medicine High Impact Case Reports | June 18, 2020 | Volume: 8 | Issue: No issue available | Pages: No page available

10.1177/2324709620934324 | PMID 32551950 Get It

A 79-year-old man was admitted for a transcatheter aortic valve replacement due to severe aortic stenosis. A preoperative chest computed tomography with angiography revealed an apical variant hypertrophic cardiomyopathy with a prominent apical pouch. In addition, there was near-complete obliteration of the left ventricle in the mid to apical aspect during systole suggesting a midventricular gradient. Postoperative transthoracic echocardiography confirmed the apical variant hypertrophic cardiomyopathy with an apical aneurysm and a gradient with a peak velocity of 2 m/s, and mid-cavitary gradient with a peak velocity of 3 m/s. It also revealed a fusiform aneurysmal dilatation of the ascending aorta.
Comparison of Echocardiographic parameters with Cardiac Magnetic Resonance Imaging in the Assessment of Right Ventricular Function
Chao, Chieh Ju, Siegel, Robert J. , Pujari, Sai Harika , Mookadam, Farouk, Venepally, Nithin R. , Wang, Panwen , Ashraf, Hasan , Marcotte, François , Semkiv, Oksana I., Fath, Ayman R. , Jokerst, Clinton, Agasthi, Pradyumna , Chao, Chieh‐Ju , Mookadam, Farouk , Ashraf, Hasan , Brown, Lisa Marie , Allam, Mohamed , Arsanjani, Reza

Mayo Clinic

No container title available | June 10, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.159183046.66745518 Get It

Introduction: The right ventricle (RV) strain measured by speckle tracking (RVS) is a novel method of assessing RV function. We compared RVS to RV fractional area change (FAC%), tricuspid annular peak systolic excursion (TAPSE) and Doppler tissue imaging-derived peak systolic velocity (S’) in the assessment of right ventricular (RV) systolic function measured using cardiac magnetic resonance imaging (MRI). Methods: We enrolled consecutive patients who underwent cardiac MRI between Jan 2012- Dec 2017 and a transthoracic echocardiogram (TTE) within 1 month of the MRI with no interval event. Baseline clinical characteristics and MRI parameters were extracted from chart review. Echocardiographic parameters were measured prospectively. TTE parameters including RVS, TAPSE, S’ and FAC% were tested for accuracy to identify impaired RV EF (EF <45% & <30%) using receiver operator curves. Results: The study cohort included 500 patients with mean age 55 yr ± 18 and right ventricular systolic pressure 33.7 ± 13.6 mmHg. The area under ROC for RVS was 0.69 (95% CI 0.63 – 0.75) and 0.78 (95% CI 0.70 – 0.88) to predict RVEF <45% & RVEF <30% respectively. The RV FAC % had second highest accuracy of predicting RVEF among all the TTE parameters tested in study. Conclusion: Right ventricular strain is the most accurate echocardiographic method to detect impaired right ventricular systolic function when using MRI as the gold standard.
Myocardial Cut-off Sign is a Sensitive and Specific Cardiac Computed Tomography and Magnetic Resonance Imaging Sign to Distinguish Left Ventricular Pseudoaneurysms From True Aneurysms
Ballard, David H., Jokerst, Clinton, Raptis, Constantine A., Pilgram, Thomas K., Woodard, Pamela K., Ballard, David H., Jokerst, Clinton, Raptis, Constantine A., Pilgram, Thomas K., Woodard, Pamela K.

Mayo Clinic

Journal of Thoracic Imaging | May 19, 2020 | Volume: 37 | Issue: 1 | Pages: 58-65

10.1097/rti.0000000000000525 | PMID 32427649 Get It

Purpose: The purpose of this study was to describe the myocardial cut-off sign, assess its ability to distinguish left ventricular pseudoaneurysms (LV PSAs) from true aneurysms (LVAs), and compare its performance with other imaging findings and quantitative measurements used to differentiate LV PSAs from LVAs. Materials and Methods: This retrospective single-center study identified patients with preoperative cardiac computed tomography (CT) or magnetic resonance imaging (MRI) and surgically confirmed LVAs or LV PSAs over a 10-year period. Seventeen LV PSAs (11 MRI, 6 CT) and 18 LVAs (10 MRI, 8 CT) were included. The myocardial cut-off sign was objectively a >50% decrease in aneurysm sac wall thickness measured at 1 cm from the aneurysmal neck (measurements at 2 cm were also assessed) and subjectively an abrupt “cut-off” of myocardium for the aneurysm sac for PSA compared with a gradual tapering of sac wall thickness for LVA. Two radiologists independently evaluated images for the subjective presence of this sign. Results: The myocardial cut-off sign was 91% sensitive and 97% specific when measured 1 cm from the aneurysm neck. When measured at 2 cm from the neck, the sign was 100% sensitive and 69% specific. Subjective analysis of whether the myocardium appeared “cut-off” was 94% to 100% sensitive and 78% to 94% specific with excellent agreement for both PSA (κ=0.94) and LVA (κ=0.83). Conclusions: The myocardial cut-off sign on cardiac CT and MRI is a sensitive and specific finding of LV PSA. Specificity is improved with objective measurements compared with subjective assessment (97% vs. 78% to 94%). This sign may help radiologists distinguish between LV PSAs and LVAs.
Individuals With Scleroderma May Have Increased Risk of Sleep-Disordered Breathing
Nokes, Brandon , Raza, Hassan , Cartin‐Ceba, Rodrigo , Lyng, Phillip J., Krahn, Lois E., Wesselius, Lewis , Jokerst, Clinton, Umar, Sarah B. , Griffing, W. Leroy , Neville, Matthew R., Parish, James M., Raza, Hassan A, Lyng, Philip J., Malhotra, Atul

Mayo Clinic

Journal of Clinical Sleep Medicine | November 14, 2019 | Volume: 15 | Issue: 11 | Pages: 1665-1669

10.5664/jcsm.8036 | PMID 31739857 Get It

Never Events in Radiology and Strategies to Reduce Preventable Serious Adverse Events
Ponce, Lisa , Osborn, Howard H., Jokerst, Clinton, Ponce, Lisa M, Flug, Jonathan A.

Mayo Clinic

RadioGraphics | October 10, 2018 | Volume: 38 | Issue: 6 | Pages: 1823-1832

10.1148/rg.2018180036 | PMID 30303781 Get It