Citations

Clear

26 citation(s) found for "Haley, William".

In Vivo Comparison of Radiation Exposure of Dual-Energy CT Versus Low-Dose CT Versus Standard CT for Imaging Urinary Calculi
Jepperson, Maria A., Cernigliaro, Joseph G. , Morin, Richard L. , Haley, William E. , Thiel, David D. , Ibrahim, El‐Sayed H.

Mayo Clinic

Journal of Endourology | July 24, 2014 | Volume: 29 | Issue: 2 | Pages: 141-146

10.1089/end.2014.0026 | PMID 25058059 Get It

Purpose: Dual-energy computed tomography (DECT) is an emerging imaging modality with the unique capability of determining urinary stone composition. This study compares radiation exposure of DECT, standard single-energy CT (SECT), and low-dose renal stone protocol single-energy CT (LDSECT) for the evaluation of nephrolithiasis in a single in vivo patient cohort. Materials and Methods: Following institutional review board (IRB) approval, we retrospectively reviewed 200 consecutive DECT examinations performed on patients with suspected urolithiasis over a 6-month period. Of these, 35 patients had undergone examination with our LDSECT protocol, and 30 patients had undergone examination of the abdomen and pelvis with our SECT imaging protocol within 2 years of the DECT examination. The CT dose index volume (CTDI vol ) was used to compare radiation exposure between scans. Image quality was objectively evaluated by comparing image noise. Statistical evaluation was performed using a Student's t -test. Results: DECT performed at 80/140 kVp and 100/140 kVp did not produce a significant difference in radiation exposure compared with LDSECT ( p =0.09 and 0.18, respectively). DECT performed at 80/140 kVp and 100/140 kVp produced an average 40% and 31%, respectively, reduction in radiation exposure compared with SECT ( p <0.001). For patients imaged with the 100/140 kVp protocol, average values for images noise were higher in the LDSECT images compared with DECT images ( p <0.001) and there was no significant difference in image noise between DECT and SECT images in the same patient ( p =0.88). Patients imaged with the 80/140 kVp protocol had equivocal image noise compared with LDSECT images ( p =0.44), however, DECT images had greater noise compared with SECT images in the same patient ( p <0.001). Of the 75 patients included in the study, stone material was available for 16; DECT analysis correctly predicted stone composition in 15/16 patients (93%). Conclusion: DECT provides knowledge of stone composition in addition to the anatomic information provided by LDSECT/SECT without increasing patient radiation exposure and with minimal impact on image noise.
Three-Dimensional Dual-Energy Computed Tomography for Enhancing Stone/Stent Contrasting and Stone Visualization in Urolithiasis
Ibrahim, El-Sayed H. , Haley, William E. , Jepperson, Maria A., Thiel, David D. , Wehle, Michael J., Cernigliaro, Joseph G.

Mayo Clinic

Case Reports in Urology | July 17, 2013 | Volume: 2013 | Issue: No issue available | Pages: 1-4

10.1155/2013/646087 | PMID 23956922 Get It

The use of dual-energy computed tomography (DECT) for evaluating urinary calculi has been appreciated due to the modality’s capability of differentiating between uric acid (UA) and non-UA stones, which are color coded based on a postprocessing algorithm. No other imaging modality or laboratory test is able to identify the stone composition without first attaining the stone material. Knowledge of the stone composition is clinically significant since UA calculi may be treated medically whereas non-UA calculi may require surgical removal. Regardless of the stone type, ureteral stents are often placed to prevent or treat obstruction. Recent work has demonstrated that commonly used stents are also colored based on their dual energy characteristics and may thereby either improve or obscure the identification of adjacent calculi. Herein, we report the case of a 65-year-old man who underwent percutaneous nephrolithotomy of a large staghorn stone with subsequent significant residual stone fragments noted on a follow-up scan. By using three-dimensional DECT and taking advantage of color contrasting, the stone composition, burden, shape, and boundary were clearly depicted apart from the adjacent stent, resulting in successful medical treatment and obviating the need for further surgical intervention.
Renal Autotransplantation for Iatrogenic High-Grade Ureteric Stricture
Soto, Jose Soto , Cernigliaro, Joseph G. , Haley, William E. , Phillips, Michael

Mayo Clinic

Case Reports in Urology | December 4, 2012 | Volume: 2012 | Issue: No issue available | Pages: 1-3

10.1155/2012/259527 | PMID 23304622 Get It

A 47-year-old Hispanic woman developed a chronically obstructed left kidney, due to a long-segment ureteric stricture deemed not amenable to reimplantation, following left ovarian cyst excision in 2004. Therefore, a ureteral stent requiring exchange every 3 months was necessary, due to hydronephrosis, recurrent urosepsis, chronic pain, and a poor quality of life. Her medical history was complicated by hypertension, poorly controlled diabetes mellitus, and microalbuminuria, suggesting early diabetic nephropathy. A left nephrectomy was recommended. This was deferred, due to concern for progressive kidney failure associated with her comorbidities. A radionuclide Tc-99m MAG3 renal scan revealed differential perfusion as follows: 44% left kidney and 56% right kidney, with symmetrical uptake on the renogram phase and delayed excretion on the left, which were correctted following furosemide administration. A left ureteronephrectomy with autotransplantation of the left kidney and ureteroneocystostomy was performed in 2009. Since then, the patient has experienced no further complications or need for invasive procedures, with excellent diabetic control and stable renal function (eGFR > 60 mL/min/1.73 m2). This technique is seldom employed in the surgical management of complex ureteral injuries, but may be an alternative for appropriate cases.
Hypertension Optimal Treatment (HOT) Study
Hedner, Thomas, Jamerson, Kenneth , Julius, Stevo, Haley, William E. , Zabalgoitia, Miguel, Butt, Amir R., Rahman, Syed N. , Hansson, Lennart, Kjeldsen, Sverre Erik

Mayo Clinic

Hypertension | June 12, 2012 | Volume: 31 | Issue: 4 | Pages: 1014-1020

10.1161/01.hyp.31.4.1014 | PMID 9535429 Get It

Abstract —The Hypertension Optimal Treatment Study is a prospective trial conducted in 26 countries. The aims are to (1) evaluate the relationship between three levels of target office diastolic blood pressure (BP) (≤80, ≤85, or ≤90 mm Hg) and cardiovascular morbidity and mortality in hypertensive patients and (2) examine the effects on cardiovascular morbidity and mortality of 75 mg aspirin daily versus placebo. A total of 19 193 patients between 50 and 80 years of age had been randomized by the end of April 1994. Treatment was initiated with felodipine 5 mg daily, and additional therapy was given in accordance with a set protocol. The present substudy of 926 patients performed in nine countries aimed to (1) compare home with office BP in a representative subsample of the HOT population after the titration of treatment was completed and (2) clarify whether the separation into the target groups could be expanded into the out-of-office setting. The differences between office and home measurements in diastolic BP of 0.2 mm Hg (SD, 9; 95% confidence interval, −0.36 to 0.81; P =.40) and systolic BP of 0.5 mm Hg (SD, 15; 95% confidence interval, −0.53 to 1.46; P =.21) were not significant. The group differences in home BP were 1.9 mm Hg (≤80 versus ≤85) and 1.2 mm Hg (≤85 versus ≤90) for diastolic BP (F=11.69; ANOVA, P <.0001) and 2.6 and 2.1 mm Hg for systolic BP (F=8.44, P =.0002). Thus, office and home BPs measured with the same semiautomatic device are comparable in treated hypertensive subjects in the HOT Study, and the separation into the target groups based on office readings prevails at home.
Opportunities for Improving Management of Advanced Chronic Kidney Disease
Patwardhan, Meenal, Matchar, David B. , Samsa, Gregory P., Haley, William E.

Mayo Clinic

American Journal of Medical Quality | June 6, 2008 | Volume: 23 | Issue: 3 | Pages: 184-192

10.1177/1062860608314985 | PMID 18539979 Get It

Utility of the Advanced Chronic Kidney Disease Patient Management Tools: Case Studies
Patwardhan, Meenal, Matchar, David B. , Samsa, Gregory P., Haley, William E.

Mayo Clinic

American Journal of Medical Quality | February 27, 2008 | Volume: 23 | Issue: 2 | Pages: 105-114

10.1177/1062860607313142 | PMID 18305098 Get It