Citations

Clear

59 citation(s) found for "Frank, Konstantin".

Validated 5‐point photonumeric scales for the assessment of the periorbital region
Pavicic, Tatjana , Pooth, Rainer, Prinz, Valentina, Cajkovsky, Mia, Hernandez, Claudia A, Mueller, Daniel S., Sattler, Sonja , Klepetko, Heike , Day, Doris , Kerscher, Martina , Frank, Konstantin , Fabi, Sabrina G. , Suwanchinda, Atchima , Cotofana, Sebastian , Frank, Konstantin , Green, Jeremy B. , Mueller, Daniel S., Suwanchinda, Atchima , Cotofana, Sebastian

Mayo Clinic

Journal of Cosmetic Dermatology | December 5, 2021 | Volume: 21 | Issue: 1 | Pages: 158-166

10.1111/jocd.14643 | PMID 34865301 Get It

AbstractObjectiveThe objective of this investigation was to create and validate 5‐point photonumeric scales for the assessment of dynamic crow's feet, static crow's feet, and infraorbital hollows.Material and methodsThree novel 5‐point photonumeric scales were created by a medical team. A total of 12 raters from all over the world performed a digital validation, and a total of 5 raters a live validation of the created scale.ResultsThe statistical analysis revealed almost perfect intra‐rater and inter‐rater reliability in the digital validation of the scales for the assessment of static and dynamic crow's feet as well as infraorbital hollows. In the live validation, both crow's feet scales showed almost perfect intra‐rater reliability, while the Croma Infraorbital Hollow Assessment Scale showed substantial intra‐rater reliability. Inter‐rater reliability was substantial for all three scales in the live validation. All three scales, the Croma Dynamic Crow's Feet Assessment Scale, Croma Static Crow's Feet Assessment Scale, and Croma Infraorbital Hollow Assessment Scale, were validated digitally and in a live setting.ConclusionThe created scales to assess infraorbital hollowing, dynamic and static crow's feet have been shown to provide substantial to almost perfect agreement in the digital and live validation and can thus be considered as helpful tools in the clinical and research setting. While technical methods and appliances to assess the degrees of severity of age‐dependent features are advancing, validated scales are of great importance due to their ease of use and, as shown by the validations, reliability, and reproducibility.
Reliability of 3‐dimensional surface imaging of the face using a whole‐body surface scanner
Xu, Ya , Frank, Konstantin , Kohler, Lukas , Ehrl, Denis , Alfertshofer, Michael , Giunta, Riccardo Enzo , Moellhoff, Nicholas , Cotofana, Sebastian , Koban, Konstantin Christoph , Giunta, Riccardo E. , Cotofana, Sebastian , Alfertshofer, Michael , Giunta, Riccardo Enzo , Moellhoff, Nicholas

Mayo Clinic

Journal of Cosmetic Dermatology | November 3, 2021 | Volume: 21 | Issue: 4 | Pages: 1464-1470

10.1111/jocd.14555 | PMID 34731521 Get It

AbstractObjectiveTo the knowledge of the authors, no data about the reproducibility and accuracy of 3‐dimensional surface imaging of the face using a whole‐body scanner are available. Thus, the objective of this investigation was to assess the reproducibility of facial scans acquired using a whole‐body imaging device.Material and MethodsThis investigation investigated 220 3‐D scans of a total of 22 healthy volunteers (with a mean age of 29.36 years). Two consecutive 3‐D images using a Vectra WB360 of the volunteers were obtained utilizing a whole‐body imaging device. Predefined distances in the face were performed in each scan and compared. Furthermore, surface deviation between two consecutively captured scans was assessed.ResultsThe distance with the smallest statistical significance was found to be at the nose with p = 0.998, while the biggest statistical significance was found in the midface with p = 0.658. The area with the biggest surface deviation between the superimposed scans was the neck with a root mean square (RMS) of 1.62 ± 1.71, and the area with the smallest surface deviation was the forehead with a RMS of 0.17 ± 0.05.ConclusionThe whole‐body imaging device investigated in this study can be utilized to capture the face and provides enough accuracy to compare scans. Even though not directly investigated, it can be hypothesized that the error caused by repositioning the patient between a baseline and a follow‐up scan will not be too big to consider measurements performed with the whole‐body imaging device as impractical.
Soft tissue filler augmentation of the orbicularis retaining ligament to improve the lid‐cheek junction
Bernardini, Francesco P. , Alfertshofer, Michael , Frank, Konstantin , Davidović, Kristina , Voropai, Daria , Valli, Andrea Maria Francesco, Cotofana, Sebastian , Alfertshofer, Michael , Frank, Konstantin , Cotofana, Sebastian , Casabona, Gabriela , Moellhoff, Nicholas , Gotkin, Robert H. , Valli, Andrea

Mayo Clinic

Journal of Cosmetic Dermatology | October 22, 2021 | Volume: 20 | Issue: 11 | Pages: 3446-3453

10.1111/jocd.14495 | PMID 34679226 Get It

AbstractBackgroundThe orientation of facial ligaments changes with increasing age due to the loss of bony support. Soft tissue filler injections placed in close proximity to facial ligaments can alter their orientation to help achieve an improved and younger aesthetic appearance.ObjectiveTo assess the anatomic and aesthetic effects of a standardized injection with soft tissue filler placed directly inferior to the orbicularis retaining ligament in the infraorbital region.MethodsA total of 163 patients with signs of infraorbital aging were treated with a standardized soft tissue filler injection into and in close proximity to the orbicularis retaining ligament (ORL). 2D frontal images of the infraorbital region were rated by eleven blinded and independent raters with regards to the aesthetic appearance of the infraorbital region before and after the standardized injection treatment.ResultsThe aesthetic appearance of the entire infraorbital region (lid‐cheek junction) was rated before and after the treatment. The severity of the tear trough (medial aspect of the infraorbital region) as well as the hollowing of the lateral aspect of the infraorbital region also was rated before and after the treatment. Aesthetic improvement was statistically significant when evaluated by the blinded raters, the treating physician, and the patients. All the results were “very much improved” compared to baseline.ConclusionThe effectiveness of this injection technique is thought to be due to the strategic placement of soft tissue filler that helps to reposition facial ligaments that have changed their orientation during the aging process.
Real-Time Ultrasound Imaging of the Tear Trough: Lessons Learned From Functional Anatomy
Calomeni, Mariana, Alfertshofer, Michael , Frank, Konstantin , Dennison, Rebekah, Bravo, Bruna Felix, Velthuis, Peter J. , Cotofana, Sebastian , Bihun, Rebekah , Elias, Mariana Calomeni , Alfertshofer, Michael , Bravo, Bruna , Cotofana, Sebastian , Frank, Konstantin , Moellhoff, Nicholas , Schelke, Leonie , Green, Jeremy B. , Bihun, Rebekah J.

Mayo Clinic

Aesthetic Surgery Journal | October 6, 2021 | Volume: 42 | Issue: 5 | Pages: 518-526

10.1093/asj/sjab351 | PMID 34610093 Get It

AbstractBackgroundThe tear trough is one of the most challenging facial regions for soft-tissue filler injections. A thorough understanding of the underlying facial, muscular, and vascular anatomy is crucial to perform safe and effective tear trough injectable treatments.ObjectivesThe authors sought to evaluate the location and function of the angular vein in the tear trough in 3 different facial expressions: repose, smiling, and max. orbicularis oculi contraction.MethodsTwenty study participants with a mean age of 48.3 years and mean BMI of 24.5 kg/m2 were investigated via functional ultrasound imaging. The diameter of the angular vein and the velocity and direction of venous blood flow were analyzed in repose, smiling, and during max. orbicularis oculi contraction.ResultsThe angular vein was identified in 100% of the cases to travel inside the orbicularis oculi muscle (intra-muscular course) within the tear trough, whereas the angular artery was not identified in this location. The distance between the angular vein and the inferior orbital rim was (lateral to medial): 4.6 mm, 4.5 mm, 3.9 mm, and 3.8 mm. The caudally directed blood flow was in repose 10.2 cm/s and was 7.3 cm/s at max. orbicularis oculi muscle contraction; however, no blood flow was detectable during smiling.ConclusionsThe diameter and the venous blood flow of the angular vein varied between the 3 tested facial expressions. Based on these anatomical findings, the deep injection approach to the tear trough is recommended due to the intramuscular course of the angular vein.
Safety and efficacy of microneedling technology in the treatment of acne scars
Alfertshofer, Michael , Kaye, Kai , Frank, Konstantin , Mercado‐Perez, Arnaldo , Hargiss, J. Blade , Cotofana, Sebastian , Frank, Konstantin , Mercado-Perez, Arnaldo, Hargiss, John Blade , Cotofana, Sebastian , Alfertshofer, Michael , Casabona, Gabriela , Green, Jeremy B.

Mayo Clinic

Journal of Cosmetic Dermatology | October 2, 2021 | Volume: 20 | Issue: 11 | Pages: 3482-3491

10.1111/jocd.14502 | PMID 34596936 Get It

AbstractBackgroundCurrent options for the reduction of acne scarring (eg, ablative laser resurfacing) are associated with considerable side effects and limitations in terms of patient population. Percutaneous collagen induction via microneedling poses an alternative treatment method due to its low rates of reported adverse events and side effects.ObjectiveTo assess the safety and effectiveness of microneedling treatments in reducing acne scars.MethodsA total of 22 patients (18 females and 4 males) with a mean age of 38 ± 7.6 years were assessed regarding the appearance of facial acne scarring. Acne scars were assessed via the Acne Scar Assessment Scale (ASAS) and the Goodman and Baron acne scar grading scale before and after two/three treatments. Additionally, the post‐interventional development of side reactions, adverse events, and patient‐reported outcomes (eg, pain/discomfort, skin redness) was reported.ResultsCompared to baseline, the mean ASAS value was improved statistically significantly on average by 1.41 and 1.46 after the second treatment as assessed by the independent raters and the patients, respectively. In patients who received a total of three treatments, a statistically significant mean improvement in ASAS value of 1.35 and 1.66 compared to baseline was assessed by the independent raters and patients, respectively. No unexpected adverse events were reported. The severity and rate of side reactions decreased over the course of this study.ConclusionMicroneedling treatments can pose a safe and effective option in the reduction of acne scarring. In this study, microneedling helped achieving a significant reduction of acne scars while showing high patient safety.
Endoscopic Browlift in Patients With Receding Hairlines
Boonipat, Thanapoom , Hebel, Nathan , Lin, J, Frank, Konstantin , Möllhoff, Nicholas, Cotofana, Sebastian, Cotofana, Sebastian , Bradley, Elizabeth A. , Shapiro, Daniel, Mardini, Samir

Mayo Clinic

Journal of Craniofacial Surgery | October 1, 2021 | Volume: 33 | Issue: 2 | Pages: 615-619

10.1097/scs.0000000000008156 | PMID 34593745 Get It

Abstract Patients with receding or high hairlines have traditionally been considered unfavorable candidates for endoscopic brow lift as this can further lengthen the hairline. We analyzed outcomes in patients that underwent a novel endoscopic brow lift technique with placement of incisions and anchoring Endotine Forehead Devices (CoApt Systems Inc, Palo Alto, CA, USA) directly at the natural forehead crease lines, in an effort to minimize elevation of the hairline, whereas providing well-hidden scars. We retrospectively reviewed all patients who underwent this new Endotine and incision placement between 2016 and 2020. Preoperative and postoperative photographs of all patients were analyzed to determine the postoperative changes in brow elevation and forehead length proportion (defined as length from cranium to chin). The forehead length proportion was unchanged pre- and post-operatively, with no statistically significant differences noted (P = 0.48). The average brow position elevation ranged from 2.78 mm in the medial location to 5.05 mm in the lateral location. All patients were happy with their appearance and had improved visual fields postoperatively. The forehead scars healed well and were well hidden in forehead rhytids at long term follow-up. This novel endoscopic brow lift technique provides an option to utilize a minimally invasive approach in patients with receding hairline. With this technique, visible scars were minimized, whereas still being able to achieve reasonable brow elevation. Thus, our approach enables long term maintenance of brow elevation with inconspicuous scars in the forehead.
Longevity and subject‐reported satisfaction after minimally invasive jawline contouring
Müller, Daniel S. , Prinz, Valentina, Sulovsky, Monika , Cajkovsky, Mia, Cotofana, Sebastian , Frank, Konstantin , Müller, Daniel , Cotofana, Sebastian , Frank, Konstantin , Moellhoff, Nicholas

Mayo Clinic

Journal of Cosmetic Dermatology | September 18, 2021 | Volume: 21 | Issue: 1 | Pages: 199-206

10.1111/jocd.14410 | PMID 34536051 Get It

AbstractBackgroundMinimally invasive treatments as soft tissue filler injections can enhance the appearance of the jawline. This prospective, single‐center study investigated aesthetic outcome, patient satisfaction, adverse events, and volume changes after jawline contouring using standardized reporting scales and objectifiable 3D surface analysis.MethodsA total of 30 patients (1 male and 29 females, mean age: 57.2 (±8.7) years) were investigated. Patients underwent jawline augmentation using a highly cross‐linked hyaluronic acid–based soft tissue filler. Three‐dimensional surface imaging was performed after 2 weeks, and 3, 6, 9, and 12 months. Furthermore, the aesthetic results and the occurrence of complications were investigated after two weeks, and 3, 6, 9, and 12 months.ResultsThe surface‐volume coefficient (SVC) had an average of 1.10 ± 0.2 after 14 days, 0.95 ± 0.1 after 3 months, 0.83 ± 0.1 after 6 months, 0.74 ± 0.1 after 9 months, and 0.63 ± 0.1 after 12 months. A significant correlation was revealed between time of measurement and measured SVC with rp = −0.761, p < 0.001. Multivariate analysis revealed a significant difference between the measured SVC and the different time points of measurement with p < 0.001. The data revealed strong aesthetic improvement with results most often reported as “very much improved” according to the 5‐point GAIS after 3, 6, and 9 months, both by the investigator and by the patients. A 12‐month follow‐up analysis showed “much improved” results in a majority of cases.ConclusionThe result of this investigation showed that jawline enhancement using minimally invasive soft tissue filler injections produces durable, safe results that are generally rated as very satisfying from a patient's and investigator's perspective over a time period of 12 months.
Change in Rheologic Properties of Facial Soft-Tissue Fillers across the Physiologic Angular Frequency Spectrum
Hamade, Hassan, Bertucci, Vince , Fagien, Steven , Pavicic, Tatjana , Nikolis, Andreas , Lachman, Nirusha , Hadjab, Abdelbasste, Frank, Konstantin , Green, Jeremy B, Cotofana, Sebastian , Green, Jeremy B.

Mayo Clinic

Plastic & Reconstructive Surgery | August 16, 2021 | Volume: 148 | Issue: 2 | Pages: 320-331

10.1097/prs.0000000000008188 | PMID 34398083 Get It

Background: The number of soft-tissue filler injections performed in the United States is constantly increasing and reflects the high demand for enhanced facial and body attractiveness. The objective of the present study was to measure the viscoelastic properties of soft-tissue fillers when subjected to different testing frequencies. The range of tested frequencies represents clinically different facial areas with more [lips (high frequency)] or less [zygomatic arch (low frequency)] soft-tissue movement. Methods: A total of 35 randomly selected hyaluronic acid–based dermal filler products were tested in an independent laboratory for their values of G′, G″, tan δ, and G* at angular frequencies between 0.1 and 100 radian/second. Results: The results of the objective analyses revealed that the viscoelastic properties of all tested products changed between 0.1 and 100 radian/second angular frequency. Changes in G′ ranged from 48.5 to 3116 percent, representing an increase in their initial elastic modulus, whereas changes in G″ ranged from −53.3 percent (i.e., decrease in G″) to 7741 percent (i.e., increase in G″), indicating both an increase and a decrease in their fluidity, respectively. Conclusions: The increase in G′ would indicate the transition from a “softer” to a “harder” filler, and the observed decrease in G″ would indicate an increase in the filler’s “fluidity.” Changes in the frequency of applied shear forces such as those occurring in the medial versus the lateral face will influence the aesthetic outcome of soft-tissue filler injections.
The mobility of the superficial and deep midfacial fat compartments: An ultrasound‐based investigation
Velthuis, Peter J. , Lowry, Natalia, Rohrich, Rod J., Swift, Arthur, Frank, Konstantin , Cotofana, Sebastian , Frank, Konstantin , Frank, Konstantin , Dumbrava, Mihai , Cotofana, Sebastian , Schelke, Leonie , Gotkin, Robert H. , Moellhoff, Nicholas , Dumbravă, Mihai

Mayo Clinic

Journal of Cosmetic Dermatology | August 8, 2021 | Volume: 20 | Issue: 12 | Pages: 3849-3856

10.1111/jocd.14374 | PMID 34365716 Get It

AbstractBackgroundUnderstanding the mobility of the midface and the separate contributions of the superficial and deep fat compartments is essential for natural esthetic outcomes following soft tissue filler or fat grafting procedures. A study was designed that used ultrasound imaging to demonstrate in vivo visualization and quantification of distances and movements in the midface.MethodsA total of 48 midfaces of 24 healthy Caucasian volunteers, all naïve of esthetic procedures, (22 females; 46.85 (9.8) years; 22.83 (3.1) kg/m2) were scanned using 18 MHz ultrasound imaging. Distances between bony landmarks (inferior orbital rim, infraorbital foramen) were used as markers to measure the cranial movement of the superficial (superficial nasolabial and superficial medial cheek fat compartment) and the deep (deep pyriform space, deep medial check fat compartment, deep lateral cheek fat compartment) midfacial fat compartments between resting and smiling facial position.ResultsThe superficial midfacial fat compartment moved, on average, 3.7 mm (p < 0.001) cranially, whereas the deep midfacial fat compartments moved, on average, 0.1 mm (p > 0.05) during smiling. No gender differences in mobility were identified (p > 0.05).ConclusionThe results obtained are in line with previous cadaveric investigations and revealed, in a highly statistically significant fashion, that the superficial midfacial fat compartments move in cranial direction whereas the deep fat compartment did not display similar positional changes. These results help to guide facial injectable treatments and to understand why, in the midface, a deep supraperiosteal approach should be favored when augmenting the deep midfacial fat compartments.
The Layered Anatomy of the Nose: An Ultrasound-Based Investigation
Alfertshofer, Michael , Frank, Konstantin , Ehrl, Denis , Freytag, David L., Beleznay, Katie, Swift, Arthur, Cotofana, Sebastian , Velthuis, Peter J. , Alfertshofer, Michael , Cotofana, Sebastian , Frank, Konstantin , Moellhoff, Nicholas , Gotkin, Robert H. , Mardini, Samir

Mayo Clinic

Aesthetic Surgery Journal | August 7, 2021 | Volume: 42 | Issue: 4 | Pages: 349-357

10.1093/asj/sjab310 | PMID 34363459 Get It

AbstractBackgroundAn increasing number of soft tissue filler procedures in the nasal region has been reported. Concomitant with demand, the number of complications has risen due to the difficulty in administering filler in a region where soft tissue layering is complex.ObjectivesThe authors sought to describe the layered soft tissue arrangement of the nose as it relates to the underlying arterial vasculature and to define safer zones for nasal filler enhancement.MethodsA total of 60 (28 males and 32 females) study participants were investigated with respect to their layered anatomy in the midline of the nose utilizing ultrasound imaging. The presence and extent of the layered arrangement was examined as well as the depth of the arterial vasculature.ResultsIn the mid-nasal dorsum, a 5-layer arrangement was observed in 100% (n = 60) of all investigated cases, whereas it was found to be absent in the nasal radix and tip. The 5-layer arrangement showed an average extent of 26.7% to 67.5% in relation to nasal length. The nasal arteries coursed superficially in 91.7% of all cases in the nasal radix, in 80% in the mid-nasal dorsum, and in 98.3% in the nasal tip.ConclusionsSoft tissue filler administration in the nose carries the highest risk for irreversible vision loss compared with any other facial region. The safety of soft tissue filler rhinoplasty procedures is enhanced by knowledge of the layered anatomy of the nose, the location and depth of the major nasal vasculature, and employment of maneuvers to decrease the risk of blindness.