Citations

Clear

30 citation(s) found for "Ferrero, Andrea".

Radiation dose reduction for 3D angiography images in pediatric and congenital cardiology
Fetterly, Kenneth A. , Ferrero, Andrea , Lewis, Brad, Anderson, Jason H. , Hagler, Donald J. , Lewis, Brad R, Taggart, Nathaniel W , Anderson, Jason , Taggart, Nathaniel W. , Fetterly, Kenneth A

Mayo Clinic

Catheterization and Cardiovascular Interventions | October 5, 2020 | Volume: 97 | Issue: 4 | Pages: No page available

10.1002/ccd.29272 | PMID 33016648 Get It

AbstractObjectivesThe purpose of this study was to investigate the influence of simulated reduced‐dose three‐dimensional angiography (3DA) on the accuracy and precision of linear measurements derived from 3DA datasets.BackgroundThree‐dimensional angiography is performed during X‐ray guided interventional procedures to aid diagnosis and inform treatment strategies for children and adults with congenital heart disease. However, 3DA contributes substantially to patient radiation dose and may lead to an increased radiation‐induced cancer risk.MethodsReduced‐dose patient 3DA images were simulated by adding quantum noise to the 2D projection angiograms, then reconstructing the projection angiograms into the 3DA dataset. Dose reduction in the range 33–72% was simulated. Five observers performed 46 vessel diameter measurements along prespecified axes within 23 vessel segments from 11 patient 3DA datasets. Statistical tests were performed to assess the influence of radiation dose reduction on the accuracy and precision of vessel diameter measurements.ResultsVessel diameter measurements were in the range 5.9– 22.7 mm. Considering all vessel segments and observers, the influence of dose level on the accuracy of diameter measurements was in the range 0.02 – 0.15 mm (p .05–.8). Interobserver variability increased modestly with vessel diameter, but was not influence by dose level (p = .52). The statistical test for observer recall bias was negative (p = .51).ConclusionsSimulated dose reduction up to 72% did not affect the accuracy or precision of the diameter measurements acquired from 3DA images. These findings may embolden 3DA radiation dose reduction for pediatric and congenital heart disease patients.
Determination of iodine detectability in different types of multiple-energy images for a photon-counting detector computed tomography system
Michalak, Gregory J. , Weaver, Jayse , Ferrero, Andrea , Gong, Hao , Fetterly, Kenneth A. , Zhou, Wei , McCollough, Cynthia H , Leng, Shuai , Zhou, Wei , McCollough, Cynthia H. , Leng, Shuai

Mayo Clinic

Journal of Medical Imaging | October 15, 2019 | Volume: 6 | Issue: 04 | Pages: 1

10.1117/1.jmi.6.4.043501 | PMID 31620546 Get It

Detection and Characterization of Renal Stones by Using Photon-Counting–based CT
Marcus, Roy , Fletcher, Joel G. , Ferrero, Andrea , Leng, Shuai , Halaweish, Ahmed F., Gutjahr, Ralf , Vrtiska, Terri J., Wells, Mike L., McCollough, Cynthia H. , Marcus, Roy P, Enders, Felicity T, McCollough, Cynthia H , Fletcher, Joel G , Leng, Shuai , Enders, Felicity

Mayo Clinic

Radiology | August 7, 2018 | Volume: 289 | Issue: 2 | Pages: 436-442

10.1148/radiol.2018180126 | PMID 30084728 Get It

Lung nodule volume quantification and shape differentiation with an ultra-high resolution technique on a photon-counting detector computed tomography system
Zhou, Wei , Montoya, Juan , McCollough, Cynthia, McCollough, Cynthia H , Leng, Shuai , Zhou, Wei , Montoya, Juan, Gutjahr, Ralf, Ferrero, Andrea, Halaweish, Ahmed F , Kappler, Steffen

Mayo Clinic

Journal of Medical Imaging | November 16, 2017 | Volume: 4 | Issue: 04 | Pages: 1

10.1117/1.jmi.4.4.043502 | PMID 29181429 Get It

Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images
Favazza, Christopher , Ferrero, Andrea , Yu, Lifeng , McMillan, Kyle, Favazza, Christopher P, McMillan, Kyle L, McCollough, Cynthia H , Leng, Shuai , Yu, Lifeng , Leng, Shuai

Mayo Clinic

Journal of Medical Imaging | October 3, 2017 | Volume: 4 | Issue: 03 | Pages: 1

10.1117/1.jmi.4.3.031213 | PMID 28983493 Get It

Lung nodule volume quantification and shape differentiation with an ultra-high resolution technique on a photon counting detector CT system
Zhou, Wei , Montoya, Juan , Gutjahr, Ralf , Ferrero, Andrea , Halaweish, A., Kappler, S. , Halaweish, A., McCollough, Cynthia H. , Leng, Shuai , Zhou, Wei

Mayo Clinic

SPIE Proceedings | March 9, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101323Q

10.1117/12.2255736 | PMID 28392613 Get It

Ultra-high spatial resolution multi-energy CT using photon counting detector technology
Gutjahr, Ralf , Ferrero, Andrea , Kappler, S. , Henning, André , Halaweish, A., Zhou, Wei , Montoya, Juan , Leng, Shuai , Halaweish, A., McCollough, Cynthia H. , Zhou, Wei

Mayo Clinic

SPIE Proceedings | March 9, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101320Y

10.1117/12.2255589 | PMID 28392615 Get It

Renal stone characterization using high resolution imaging mode on a photon counting detector CT system
Ferrero, Andrea , Gutjahr, Ralf , Henning, André , Kappler, S. , Halaweish, A., Abdurakhimova, Dilbar, Peterson, Zhane, Montoya, Juan , McCollough, C, Halaweish, A., Leng, Shuai

Mayo Clinic

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101323J

10.1117/12.2255651 | PMID 28458443 Get It

Practical implementation of channelized hotelling observers: effect of ROI size
Ferrero, Andrea , Favazza, Christopher , Yu, Lifeng , Favazza, Christopher P, Yu, Lifeng , Leng, Shuai , McCollough, Cynthia H.

Mayo Clinic

SPIE Proceedings | March 8, 2017 | Volume: 10132 | Issue: No issue available | Pages: 101320G

10.1117/12.2255530 | PMID 28943699 Get It

Technical Note: Insertion of digital lesions in the projection domain for dual‐source, dual‐energy CT
Ferrero, Andrea , Chen, Baiyu , Li, Zhoubo , Yu, Lifeng , McCollough, Cynthia, Yu, Lifeng , McCollough, Cynthia H.

Mayo Clinic

Medical Physics | February 27, 2017 | Volume: 44 | Issue: 5 | Pages: 1655-1660

10.1002/mp.12185 | PMID 28241103 Get It

PurposeTo compare algorithms performing material decomposition and classification in dual‐energy CT, it is desirable to know the ground truth of the lesion to be analyzed in real patient data. In this work, we developed and validated a framework to insert digital lesions of arbitrary chemical composition into patient projection data acquired on a dual‐source, dual‐energy CT system.MethodsA model that takes into account beam‐hardening effects was developed to predict the CT number of objects with known chemical composition. The model utilizes information about the x‐ray energy spectra, the patient/phantom attenuation, and the x‐ray detector energy response. The beam‐hardening model was validated on samples of iodine (I) and calcium (Ca) for a second‐generation dual‐source, dual‐energy CT scanner for all tube potentials available and a wide range of patient sizes. The seven most prevalent mineral components of renal stones were modeled and digital stones were created with CT numbers computed for each patient/phantom size and x‐ray energy spectra using the developed beam‐hardening model. Each digital stone was inserted in the dual‐energy projection data of a water phantom scanned on a dual‐source scanner and reconstructed with the routine algorithms in use in our practice. The geometry of the forward projection for dual‐energy data was validated by comparing CT number accuracy and high‐contrast resolution of simulated dual‐energy CT data of the ACR phantom with experimentally acquired data.ResultsThe beam‐hardening model and forward projection method accurately predicted the CT number of I and Ca over a wide range of tube potentials and phantom sizes. The images reconstructed after the insertion of digital kidney stones were consistent with the images reconstructed from the scanner, and the CT number ratios for different kidney stone types were consistent with data in the literature. A sample application of the proposed tool was also demonstrated.ConclusionA framework was developed and validated for the creation of digital objects of known mineral composition, and for inserting the digital objects into projection data from a commercial dual‐source, dual‐energy CT scanner. Among other applications, it will allow a systematic investigation of the impact of scan and reconstruction parameters on kidney stone dual‐energy properties under rigorously controlled conditions.