Citations

Clear

4610 citation(s) found for "Lu, Brian".

An Injectable Neural Stimulation Electrode Made from an In‐Body Curing Polymer/Metal Composite
Trevathan, James K. , Baumgart, Ian W. , Nicolai, Evan N. , Gosink, Brian A., Asp, Anders J., Settell, Megan L. , Polaconda, Shyam , Malerick, Kevin D., Brodnick, Sarah K. , Zeng, Weifeng , McConico, Andrea L., Sanger, Zachary , Lee, Jannifer H. , Aho, Johnathon M. , Ross, Erika K., Lujan, Jose L., Williams, Justin C. , Franke, Manfred , Ludwig, Kip A. , Shoffstall, Andrew J. , Knudsen, Bruce E. , Trevathan, James K , Ludwig, Kip A , Shoffstall, Andrew J , Asp, Anders J., Suminski, Aaron J. , Ross, Erika K., Weber, Douglas J.

Mayo Clinic

Advanced Healthcare Materials | November 7, 2019 | Volume: 8 | Issue: 23 | Pages: No page available

10.1002/adhm.201900892 | PMID 31697052 Get It

Abstract Implanted neural stimulation and recording devices hold vast potential to treat a variety of neurological conditions, but the invasiveness, complexity, and cost of the implantation procedure greatly reduce access to an otherwise promising therapeutic approach. To address this need, a novel electrode that begins as an uncured, flowable prepolymer that can be injected around a neuroanatomical target to minimize surgical manipulation is developed. Referred to as the Injectrode, the electrode conforms to target structures forming an electrically conductive interface which is orders of magnitude less stiff than conventional neuromodulation electrodes. To validate the Injectrode, detailed electrochemical and microscopy characterization of its material properties is performed and the feasibility of using it to stimulate the nervous system electrically in rats and swine is validated. The silicone‐metal‐particle composite performs very similarly to pure wire of the same metal (silver) in all measures, including exhibiting a favorable cathodic charge storage capacity (CSC C ) and charge injection limits compared to the clinical LivaNova stimulation electrode and silver wire electrodes. By virtue of its simplicity, the Injectrode has the potential to be less invasive, more robust, and more cost‐effective than traditional electrode designs, which could increase the adoption of neuromodulation therapies for existing and new indications.
The Effectiveness of a Non-Invasive Shot Blocking Device for Reducing Pain of In-office Injections in Hand Surgery
Rinker, Brian, Atashroo, David, Wermeling, F. Ryan, Rinker, Brian D , Stout, Megan A.

Mayo Clinic

HAND | November 6, 2019 | Volume: 16 | Issue: 6 | Pages: 770-775

10.1177/1558944719884655 | PMID 31690117 Get It

Background: The gate control theory asserts that non-painful stimuli can block pain perception. The ShotBlocker™ device is a plastic disk with blunt projections that rests on the skin, and we hypothesize that it will reduce pain during hand injections. Methods: This is a prospective randomized trial of 117 patients undergoing injections for common hand conditions. Patients were randomized into 3 groups: device, placebo (device with projections removed), and control. Patients recorded on an analog pain scale the pain severity of the injection, as well as their most recent tetanus shot. A normalized pain score was obtained from the difference between the injection and tetanus shot pain scores. The mean non-normalized and normalized scores for each treatment group were compared to the control group using the Wilcoxon signed rank test. Results: There were 91 women and 26 men. Common diagnoses included trigger finger (n = 53), DeQuervain’s tendonitis (n = 33), and basal joint arthritis (n = 22). The groups did not differ significantly in age, gender, or diagnosis. Mean pain score in the device group was 5.2 out of 10, and it was 5.7 for the control group. The normalized pain score in the device group was significantly lower than the control group. Normalized and non-normalized pain scores for the placebo group were not significantly lower than the control group. Conclusions: The shot blocking device effectively reduced pain of injection versus controls when pain scores were normalized for pain tolerance. The modified device did not reduce the pain of injection, suggesting that gate control is the mechanism of action.
The Multifactorial Contribution of Publications in Plastic Surgery Journals in Microsurgery Education
Restrepo, David J. , Oliver, Jeremie D. , Huayllani, María T. , Ball, Colleen T. , Spaulding, Aaron , Cochuyt, Jordan J., Rinker, Brian, Forte, Antonio J. , Boczar, Daniel , Spaulding, Aaron C. , Rinker, Brian D, Forte, Antonio Jorge , Spaulding, Aaron , Oliver, Jeremie D , Sisti, Andrea

Mayo Clinic

Annals of Plastic Surgery | November 4, 2019 | Volume: 84 | Issue: 2 | Pages: 130-134

10.1097/sap.0000000000002040 | PMID 31688111 Get It

Background Microsurgery is one of the most complex operative skills. Recent restrictions on residents’ working hours challenge residency program directors to ensure skill acquisition with scant time dedicated to microsurgery practice. We aimed to summarize the contribution of plastic surgery journals in microsurgical education. Methods A comprehensive literature search was performed. Results We observed an increasing number of publications on microsurgery education over the years. This could be due to the adoption of new technologies developed in the last 2 decades, the concerns about quality of resident training in the context of reduced work hours, the well-described benefit of medical simulations in other specialties, and the pressure on trainees to be proficient before operating on patients. The variety of aspects addressed in plastic surgery publications is broad: simulators, courses, skills assessment, national surveys, and technology trends. Conclusion There is an upward trend in the number of publications and plastic surgery journals, demonstrating a remarkable contribution to microsurgery training.
Reliable outcomes and survivorship of primary total knee arthroplasty for osteonecrosis of the knee
Mehrotra, Kapil, Pagnano, Mark W. , Chalmers, Brian P. , Mehrotra, Kapil G, Sierra, Rafael J. , Taunton, Michael J. , Abdel, Matthew P.

Mayo Clinic

The Bone & Joint Journal | November 1, 2019 | Volume: 101-B | Issue: 11 | Pages: 1356-1361

10.1302/0301-620x.101b11.bjj-2019-0576.r1 | PMID 31674235 Get It

AimsKnee osteonecrosis in advanced stages may lead to joint degeneration. Total knee arthroplasty (TKA) for osteonecrosis has traditionally been associated with suboptimal results. We analyzed outcomes of contemporary TKAs for osteonecrosis, with particular emphasis on: survivorship free from aseptic loosening, any revision, and any reoperation plus the clinical outcomes, complications, and radiological results.Patients and MethodsIn total, 156 patients undergoing 167 primary TKAs performed for osteonecrosis between 2004 and 2014 at a single institution were reviewed. The mean age at index TKA was 61 years (14 to 93) and the mean body mass index (BMI) was 30 kg/m2(18 to 51) The mean follow-up was six years (2 to 12). A total of 110 TKAs (66%) were performed for primary osteonecrosis and 57 TKAs (34%) for secondary osteonecrosis. Overall, 15 TKAs (9%) had tibial stems, while 12 TKAs (7%) had femoral stems. Posterior-stabilized designs were used in 147 TKAs (88%) of TKAs. Bivariate Cox regression analysis was conducted to identify risk factors for revision and reoperation.ResultsSurvivorship free from aseptic loosening, any revision, and any reoperation at ten years was 97% (95% confidence interval (CI) 93 to 100), 93% (95% CI 85 to 100), and 82% (95% CI 69 to 93), respectively. No factors, including age, sex, BMI, primary versus secondary osteonecrosis, stem utilization, and constraint, were identified as risk factors for reoperation. Four TKAs (2%) underwent revision, most commonly for tibial aseptic loosening (n = 2). Excluding revisions and reoperations, there was a total of 11 complications (7%), with the most common being a manipulation under anaesthesia (six TKAs, 4%). Mean Knee Society Scores (Knee component) significantly improved from 57 (32 to 87) preoperatively to 91 (49 to 100) postoperatively (p < 0.001). No unrevised TKAs had complete radiolucent lines or radiological evidence of loosening.ConclusionContemporary cemented TKAs with selective stem utilization for osteonecrosis resulted in durable survivorship, a low complication rate, and reliable improvement in clinical outcomes. Cite this article: Bone Joint J 2019;101-B:1356–1361.
Cryoablation of Lung Metastases: Review of Recent Literature and Ablation Technique
Eiken, Patrick W. , Welch, Brian T.

Mayo Clinic

Seminars in Interventional Radiology | October 31, 2019 | Volume: 36 | Issue: 04 | Pages: 319-325

10.1055/s-0039-1697002 | PMID 31680723 Get It

AbstractThis article reviews the current indications for image-guided thermal ablation of pulmonary metastatic disease. It also summarizes data regarding the efficacy and complications of lung cryoablation and present techniques for performing lung cryoablation as informed by the recent literature.
Disease Severity and Cost in Adhesive Small Bowel Obstruction
Finnesgard, Eric J. , Shariq, Omair A. , Knight, Ariel W. , Stephens, Daniel J. , Aho, Johnathon M. , Kim, Brian D. , Schiller, Henry J., Zielinski, Martin D. , Stephens, Daniel , Knight, Ariel, Hernandez, Matthew C. , Stephens, Daniel, Stephens, Daniel

Mayo Clinic

World Journal of Surgery | October 30, 2019 | Volume: 43 | Issue: 12 | Pages: 3027-3034

10.1007/s00268-019-05148-y | PMID 31555867 Get It

AbstractBackgroundAdhesive small bowel obstruction (ASBO) severity has been associated with important clinical outcomes. However, the impact of ASBO severity on hospitalization cost is unknown. The American Association for the Surgery of Trauma (AAST) developed an Emergency General Surgery (EGS) disease severity grading system for ASBO. We stratified patients’ ASBO severity and captured hospitalization costs hypothesizing that increased disease severity would correlate with greater costs.MethodsThis was a single‐center study of hospitalized adult patients with SBO during 2015–2017. Clinical data and estimated total cost (direct + indirect) were abstracted. AAST EGS grades (I–IV) stratified disease severity. Costs were normalized to the median grade I cost. Univariate and multivariate analyses evaluated the relationship between normalized cost and AAST EGS grade, length of hospital and ICU stay, operative time, and Charlson comorbidity index.ResultsThere were 214 patients; 119 (56%) were female. AAST EGS grades included: I (62%, n = 132), II (23%, n = 49), III (7%, n = 16), and IV (8%, n = 17). Relative to grade I, median normalized cost increased by 1.4‐fold for grade II, 1.6‐fold for grade III, and 4.3‐fold for grade IV disease. No considerable differences in patient comorbidity between grades were observed. Pair‐wise comparisons demonstrated that grade I disease cost less than higher grades (corrected p < 0.001). Non‐operative management was associated with lower normalized cost compared to operative management (1.1 vs. 4.5, p < 0.0001). In patients who failed non‐operative management, normalized cost was increased 7.2‐fold. Collectively, the AAST EGS grade correlated well with cost (Spearman's p = 0.7, p < 0.0001). After adjustment for covariates, AAST EGS grade maintained a persistent relationship with cost.ConclusionIncreasing ASBO severity is independently associated with greater costs. Efforts to identify and mitigate costs associated with this burdensome disease are warranted.Level of evidenceIII, economic/decision.
Artificial Intelligence in Radiology: A Call for Thoughtful Application
Driver, Christine , Bartholmai, Brian J. , Greenberg, Alexandra J. , Driver, C Noelle, Bowles, Bradley S, Bartholmai, Brian J , Driver, C. Noelle, Bowles, Bradley

Mayo Clinic

Clinical and Translational Science | October 30, 2019 | Volume: 13 | Issue: 2 | Pages: 216-218

10.1111/cts.12704 | PMID 31664767 Get It

Multi-frequency Electrocochleography Measurements can be Used to Monitor and Optimize Electrode Placement During Cochlear Implant Surgery
Saoji, Aniket A. , Patel, Neil S. , Carlson, Matthew L. , Neff, Brian A., Koka, Kanthaiah , Tarigoppula, Venkata S Aditya , Driscoll, Colin L. W.

Mayo Clinic

Otology & Neurotology | October 23, 2019 | Volume: 40 | Issue: 10 | Pages: 1287-1291

10.1097/mao.0000000000002406 | PMID 31644474 Get It

Objective: To report the use of multi-frequency intra-cochlear electrocochleography (ECOG) in monitoring and optimizing electrode placement during cochlear implant surgery. An acoustic pure tone complex comprising of 250, 500, 1000, and 2000 Hz was used to elicit ECOG, or more specifically cochlear microphonics (CMs), responses from various locations in the cochlea. The most apical cochlear implant electrode was used as the recording electrode. Study Design: Clinical capsule report. Setting: Tertiary academic referral center. Results: ECOG measurements were performed during cochlear implant surgery in an adult patient with significant residual acoustic hearing. The 500, 1000, and 2000 Hz CM tracings from the most apical electrode showed an amplitude peak at three different instances during the early phase of cochlear implant electrode insertion. These results are consistent with the tonotopic organization of the cochlea. During final electrode placement a slight advancement of the electrode array resulted in a correlated decrease in 250, 500, and/or 1000 Hz CM amplitude. The electrode array was retracted and repositioned which resulted in a recovery of CM amplitude. Intraoperative CM thresholds revealed a correlation of r = 0.87 with preoperative audiometric thresholds. Conclusion: We present a report on simultaneous multi-frequency ECOG monitoring during cochlear implant surgery. Multi-frequency ECOG can be used to differentiate between electrode trauma and the advancement of the apical electrode beyond the CM source in the cochlea.
A Review of Neurostimulation for Epilepsy in Pediatrics
Starnes, Keith , Miller, Kai J. , Wong-Kisiel, Lily, Lundstrom, Brian Nils, Starnes, Donnie Keith , Wong‐Kisiel, Lily C. , Lundstrom, Brian N.

Mayo Clinic

Brain Sciences | October 18, 2019 | Volume: 9 | Issue: 10 | Pages: 283

10.3390/brainsci9100283 | PMID 31635298 Get It

Neurostimulation for epilepsy refers to the application of electricity to affect the central nervous system, with the goal of reducing seizure frequency and severity. We review the available evidence for the use of neurostimulation to treat pediatric epilepsy, including vagus nerve stimulation (VNS), responsive neurostimulation (RNS), deep brain stimulation (DBS), chronic subthreshold cortical stimulation (CSCS), transcranial magnetic stimulation (TMS) and transcranial direct current stimulation (tDCS). We consider possible mechanisms of action and safety concerns, and we propose a methodology for selecting between available options. In general, we find neurostimulation is safe and effective, although any high quality evidence applying neurostimulation to pediatrics is lacking. Further research is needed to understand neuromodulatory systems, and to identify biomarkers of response in order to establish optimal stimulation paradigms.