We assessed the in vitro activity of Manuka honey against biofilm bacteria in combination with antibiotics and visualized the effect of Manuka honey on bacterial biofilms using scanning electron microscopy. The fractional biofilm eradication concentration ( ∑ FBEC ) index for vancomycin plus Manuka honey against S. aureus IDRL-4284 biofilms was 0.34, indicating a synergistic interaction. The ∑ FBEC index for gentamicin plus Manuka honey against P. aeruginosa PAO1 biofilms was 0.78–0.82, indicating an additive interaction. Scanning electron microscopy of S. aureus IDRL-4284 and P. aeruginosa PAO1 biofilms exposed to Manuka honey and artificial honey containing the same sugar composition as Manuka honey showed that the former had more pronounced effects than the latter on both S. aureus and P. aeruginosa biofilms. Visualized effects included distorted cell morphologies for both bacteria and a decrease in P. aeruginosa extracellular matrix. In conclusion, Manuka honey has a synergistic interaction with vancomycin against S. aureus biofilms and an additive interaction with gentamicin against P. aeruginosa biofilms.
Background: Warfarin is still the most commonly used anticoagulant for the treatment of venous thromboembolism and other hypercoagulable states. Warfarin metabolism is affected by multiple factors, including diet, medications, and individual patient characteristics. As both underdosing and overdosing can increase risks to patients, several studies have attempted to develop dosing protocols. However, few have investigated how patient weight and body mass index (BMI) affect warfarin dosing. Objective: The objective of this study was to determine the association between BMI and the total weekly dose (TWD) of warfarin. Methods: In this retrospective study, we identified patients taking warfarin who had an international normalized ratio (INR) within the therapeutic range to assess if there was a significant correlation between TWD, that is, maintenance warfarin dosing, and BMI in obese and nonobese patients. Results: A total of 831 patients were studied, with a BMI range between 13.4 and 63.1 kg/m 2 . We found that BMI is positively correlated with the total weekly warfarin dose. Our study showed that for each 1-point increase in BMI, the weekly warfarin dose increased by 0.69 mg. We found that the average warfarin weekly dose in this population can be estimated using the formula: 12.34 + 0.69 × BMI. Conclusion: There is an association between BMI and the TWD of warfarin. This could have dosing implications for both patients and prescribers, as patients with a high BMI will be expected to require higher doses of warfarin to maintain a therapeutic INR.
Reversible non‐ischaemic cardiomyopathy and left ventricular dysfunction after liver transplantation: a single‐centre experience
AbstractBackground & AimsNon‐ischaemic cardiomyopathy (NIC) is an early complication of liver transplantation (LT). Our aims were to define the prevalence, associated clinical factors, and prognosis of this condition.MethodsA retrospective study was performed on patients undergoingLTat our institution from January 2005 to December 2012. Patients who developedNICwere identified. Data collected included demographic and clinical data.ResultsA total 1460 transplants were performed in this period and seventeen patients developedNIC. Pretransplant medianQTc interval was 459 (range, 405–530), and median E/A ratio was 1 (range, 0.71–1.67). Fourteen patients (82%) were severely malnourished and required nutritional support. Thirteen patients (76%) had renal insufficiency. Median time to onset was 2 days post‐transplant (range, 0–20). Echocardiograms showed global left ventricular hypokinesis and a decrease in ejection fraction (EF) from a median of 65% (range, 50–81) pretransplant to a median of 21% (range, 15–32). Median raw model for end‐stage liver disease (MELD) score was 29 in patients withNICvs. 18 in patients without cardiomyopathy (P = 0.01). There was no significant difference between recipients withNICvs. recipients without cardiomyopathy regarding donor age, donor risk index, and cold and warm ischaemia time. Recovery of cardiac function occurred in 16 patients, with a medianEFof 44% (range, 25–65%) at the time of discharge. The last echocardiogram available showed a medianEFof 59% (range, 49–73%). One‐year survival of NIC patients was 94.1%.ConclusionNon‐ischaemic cardiomyopathy is a rare complication afterLT. Patients withNICare critically ill, with highMELDscore, and severe malnutrition.
Imploding and Exploding Migraine Headaches: Comparison of Methods to Diagnose Pain Directionality
Background The study aims to compare methods of determining headache directionality (imploding, exploding, and/or ocular headaches) in women with migraine, investigate the concordance between physician assignment and patient self‐assignment of pain directionality, and evaluate whether patients assigned their headaches to the same direction when queried using different methods. Directionality of migraine headache pain (imploding, exploding, or ocular) may reflect differences in the underlying pathogenesis of individual migraine attacks among and within individuals. Emerging evidence suggests that directionality of pain in migraine sufferers may predict response to onabotulinumtoxin A . The best method of determining headache directionality in migraine sufferers has not been systematically explored. Methods We conducted a prospective cross‐sectional survey study of 198 female patients with migraine presenting to a W omen's H ealth C linic. Patients determined the directionality (imploding, exploding, and/or ocular) of their own migraine pain by choosing among 3 pictures graphically representing directionality and also by responding to a written question regarding directionality. Clinicians then classified directionality of migraine pain using structured interviews. Concordance between clinician assignment of directionality and patient self‐assignment was determined with K appa coefficients. Results Subjects were females between the ages of 18 and 77 years (mean 48 years). According to patient selection of representative pictures, 62 (31.6%) had imploding headaches with or without ocular pain, 36 (18.4%) had exploding headaches with or without ocular pain, 78 (39.8%) had ocular pain only, and 20 (10.2%) had imploding and exploding headaches with or without ocular pain. Two subjects did not respond. According to patient responses to a written question, 80 (41.0%) had imploding headaches with or without ocular pain, 53 (27.2%) had exploding headaches with or without ocular pain, 46 (23.6%) had ocular pain only, and 16 (8.2%) had imploding and exploding headaches with or without ocular pain. Three subjects did not respond. For physician assignment, 69 (34.9%) subjects had imploding headaches with or without ocular pain, 89 (45%) had exploding headaches with or without ocular pain, 14 (7.1%) had ocular pain only, and 26 (13.1%) had imploding and exploding headaches with or without ocular pain. The concordance ( K appa coefficient) between physician assignment of headache directionality with patient response to the written question was 0.33 (weak agreement), between physician assignment and patient assignment via selection of representative pictures was 0.35 (weak agreement), and between patient assignment via written question and via selection of representative pictures was 0.35 (weak agreement). Conclusions The assignment of headache directionality varied substantially depending upon the method of determination. The concordance between clinician assignment, patient‐self assignment via answering a written question, and patient self‐assignment via choosing a representative picture was weak. Improved methods of determining pain directionality are needed.
ABSTRACTA 75-year-old man was diagnosed with probableCampylobacter jejuniprosthetic knee infection after a diarrheal illness. Joint aspirate and operative cultures were negative, but PCR of prosthesis sonicate fluid was positive, as was stool culture. Nineteen additional cases ofCampylobacterprosthetic joint infection reported in the literature are reviewed.
Objective: A prototype tear glucose (TG) sensor was tested in New Zealand white rabbits to assess eye irritation, blood glucose (BG) and TG lag time, and correlation with BG. Methods: A total of 4 animals were used. Eye irritation was monitored by Lissamine green dye and analyzed using image analysis software. Lag time was correlated with an oral glucose load while recording TG and BG readings. Correlation between TG and BG were plotted against one another to form a correlation diagram, using a Yellow Springs Instrument (YSI) and self-monitoring of blood glucose as the reference measurements. Finally, TG levels were calculated using analytically derived expressions. Results: From repeated testing carried over the course of 12 months, little to no eye irritation was detected. TG fluctuations over time visually appeared to trace the same pattern as BG with an average lag times of 13 minutes. TG levels calculated from the device current measurements ranged from 4 to 20 mg/dL and correlated linearly with BG levels of 75-160 mg/dL (TG = 0.1723 BG = 7.9448 mg/dL; R 2 = .7544). Conclusion: The first steps were taken toward preliminary development of a sensor for self-monitoring of tear glucose (SMTG). No conjunctival irritation in any of the animals was noted. Lag time between TG and BG was found to be noticeable, but a quantitative modeling to correlate lag time in this study is unnecessary. Measured currents from the sensors and the calculated TG showed promising correlation to BG levels. Previous analytical bench marking showed BG and TG levels consistent with other literature.
Abstract B89: Endogenous hormone levels and lobular involution of the breast among healthy, postmenopausal women in the Komen Tissue Bank Study
Abstract Background: Terminal ductal lobular units (TDLUs), the functional units of the breast for lactation, are the structures from which most breast cancers arise. TDLU involution, reflecting atrophy and loss of TDLUs, has been related to lower subsequent breast cancer risk. The predictors of such breast tissue aging, however, are not well defined. Given that estrogens and other hormones play a central role in the etiology of postmenopausal breast cancers, we conducted a study to assess the relationship between four hormones and sex hormone-binding globulin (SHBG) with markers of TDLU involution. Methods: Subjects included healthy women who volunteered between 2009 and 2011 to participate in the Komen Tissue Bank Study. Participants completed a risk factor questionnaire, provided a blood sample, and donated breast tissue for research. Our analysis was restricted to postmenopausal women who were not currently taking menopausal hormones (n=153). A pathologist, masked to patient data, assessed tissue sections for the presence of TDLUs and, among sections containing TDLUs (n=88), measured TDLU diameters for up to ten TDLUs per section. Both presence of TDLUs and TDLU diameter are inversely related to involution. Chemiluminescent immunometric assays were used to measure serum levels of estradiol (E2), SHBG, follicle-stimulating hormone (FSH), and prolactin. Percent free E2 was calculated from measured E2 and SHBG levels. Logistic regression was used to estimate odds ratios (ORs) and 95% confidence intervals (CIs) for the presence of TDLUs (none or any) associated with tertiles of serum hormone and SHBG levels. Multivariable ordinal logistic regression was used to calculate ORs, 95% CIs, and p-trend for TDLU diameter categorized as tertiles (≥218.4, 218.4-281, and ≥281 microns) with serum hormone and SHBG levels. All models were adjusted for potential confounding factors. Results: The study population was 87.6% Caucasian with a mean age of 59.5 years, and >2/3 of the women were overweight or obese. Increasing percent free E2 was significantly associated with larger TDLU diameter (OR>2.53 vs. ≥1.99: 5.58, 95% CI: 1.48-21.07; p-trend=0.01), whereas increasing SHBG was associated with smaller TDLU diameter (OR>73nmol/L vs. ≥38 nmol/L: 0.19, 95% CI: 0.05-0.74; p-trend=0.02). Total E2 (p-trend=0.49), FSH (p-trend=0.85), and prolactin (p-trend=0.58) were not associated with TDLU diameter. We did not find significant relationships between the presence of TDLUs and any of the serum levels. Our observed relationships were not modified by age or other breast cancer risk factors, including BMI, years since menopause, and history of bilateral oophorectomy. Conclusion: Based on limited data, these findings suggest that sex hormones may play a role in TDLU involution. Thus, TDLU involution may represent one mechanism by which hormone levels influence breast cancer risk. TDLU measurements may therefore be helpful in assessing breast cancer risk as a marker of breast tissue aging. Analysis of the relationships between hormones and TDLU involution among premenopausal women may provide additional insights into early events in breast carcinogenesis. Citation Format: Zeina G. Khodr, Mark E. Sherman, Ruth M. Pfeiffer, Gretchen L. Gierach, Louise A. Brinton, Roni T. Falk, Deesha Patel, Laura Linville, Susan E. Clare, Daniel Visscher, Carolyn Mies, Stephen Hewitt, Anna Maria Storniolo, Jonine D. Figueroa. Endogenous hormone levels and lobular involution of the breast among healthy, postmenopausal women in the Komen Tissue Bank Study. [abstract]. In: Proceedings of the Eleventh Annual AACR International Conference on Frontiers in Cancer Prevention Research; 2012 Oct 16-19; Anaheim, CA. Philadelphia (PA): AACR; Cancer Prev Res 2012;5(11 Suppl):Abstract nr B89.
Exome Sequencing Identifies a Novel FOXP3 Mutation in a 2‐Generation Family With Inflammatory Bowel Disease
ABSTRACTObjectives:Inflammatory bowel disease (IBD) is heritable, but a total of 163 variants commonly implicated in IBD pathogenesis account for only 25% of the heritability. Rare, highly penetrant genetic variants may also explain mendelian forms of IBD and some of the missing heritability. To test the hypothesis that rare loss‐of‐function mutations can be causative, we performed whole exome sequencing (WES) on 5 members of a 2‐generation family of European ancestry presenting with an early‐onset and atypical form of IBD.Methods:WES was performed for all of the 5 family members; the mother and 3 male offspring were affected, whereas the father was unaffected. Mapping, annotation, and filtering criteria were used to reduce candidate variants. For functional testing we performed forkhead box P3 (FOXP3) staining and a T‐cell suppression assay.Results:We identified a novel missense variant in exon 6 of the X‐linked FOXP3 gene. The c.694A>C substitution in FOXP3 results in a cysteine‐to‐glycine change at the protein position 232 that is completely conserved among all vertebrates. This variant (heterozygous in the mother and hemizygous in all 3 affected sons) did not impair FOXP3 protein expression, but significantly reduced the ability of the host's T regulatory cells to suppress an inappropriate autoimmune response. The variant results in a milder immune dysregulation, polyendocrinopathy, enteropathy, and X‐linked phenotype with early‐onset IBD.Conclusions:Our study illustrates the successful application of WES for making a definitive molecular diagnosis in a case of multiply affected families, with atypical IBD‐like phenotype. Our results also have important implications for disease biology and disease‐directed therapeutic development.
A Disposable Tear Glucose Biosensor—Part 3: Assessment of Enzymatic Specificity
Background: A concept for a tear glucose sensor based on amperometric measurement of enzymatic oxidation of glucose was previously presented, using glucose dehydrogenase flavin adenine dinucleotide (GDH-FAD) as the enzyme. Glucose dehydrogenase flavin adenine dinucleotide is further characterized in this article and evaluated for suitability in glucose-sensing applications in purified tear-like saline, with specific attention to the effect of interfering substances only. These interferents are specifically saccharides that could interact with the enzymatic activity seen in the sensor's performance. Methods: Bench top amperometric glucose assays were performed using an assay solution of GDH-FAD and ferricyanide redox mediator with samples of glucose, mannose, lactose, maltose, galactose, fructose, sucrose, and xylose at varying concentrations to evaluate specificity, linear dynamic range, signal size, and signal-to-noise ratio. A comparison study was done by substituting an equivalent activity unit concentration of glucose oxidase (GOx) for GDH-FAD. Results: Glucose dehydrogenase flavin adenine dinucleotide was found to be more sensitive than GOx, producing larger oxidation currents than GOx on an identical glucose concentration gradient, and GDH-FAD exhibited larger slope response (-5.65 × 10 −7 versus −3.11 × 10 −7 A/mM), signal-to-noise ratio (18.04 versus 2.62), and linear dynamic range (0–30 versus 0–10 mM), and lower background signal (−7.12 versus −261.63 nA) than GOx under the same assay conditions. GDH-FAD responds equally to glucose and xylose but is otherwise specific for glucose. Conclusion: Glucose dehydrogenase flavin adenine dinucleotide compares favorably with GOx in many sensor-relevant attributes and may enable measurement of glucose concentrations both higher and lower than those measurable by GOx. GDH-FAD is a viable enzyme to use in the proposed amperometric tear glucose sensor system and perhaps also in detecting extreme hypoglycemia or hyperglycemia in blood.
A Disposable Tear Glucose Biosensor—Part 2: System Integration and Model Validation
Background: We presented a concept for a tear glucose sensor system in an article by Bishop and colleagues in this issue of Journal of Diabetes Science and Technology . A unique solution to collect tear fluid and measure glucose was developed. Individual components were selected, tested, and optimized, and system error modeling was performed. Further data on prototype testing are now provided. Methods: An integrated fluidics portion of the prototype was designed, cast, and tested. A sensor was created using screen-printed sensors integrated with a silicone rubber fluidics system and absorbent polyurethane foam. A simulated eye surface was prepared using fluid-saturated poly(2-hydroxyethyl methacrylate) sheets, and the disposable prototype was tested for both reproducibility at 0, 200, and 400 μ M glucose ( n = 7) and dynamic range of glucose detection from 0 to 1000 μ M glucose. Results: From the replicated runs, an established relative standard deviation of 15.8% was calculated at 200 μ M and a lower limit of detection was calculated at 43.4 μ M . A linear dynamic range was demonstrated from 0 to 1000 μ M with an R 2 of 99.56%. The previously developed model predicted a 14.9% variation. This compares to the observed variance of 15.8% measured at 200 μ M glucose. Conclusion: With the newly designed fluidics component, an integrated tear glucose prototype was assembled and tested. Testing of this integrated prototype demonstrated a satisfactory lower limit of detection for measuring glucose concentration in tears and was reproducible across a physiological sampling range. The next step in the device design process will be initial animal studies to evaluate the current prototype for factors such as eye irritation, ease of use, and correlation with blood glucose.