Citations

Clear

367 citation(s) found for "Friedman, Paul A".

Outcome of combined cryo‐ and radiofrequency‐catheter ablation in patients with supraventricular tachycardias
Miyamoto, Koji , Mulpuru, Siva K. , Deshmukh, Abhishek , Asirvatham, Samuel J. , Munger, Thomas M. , Friedman, Paul A. , Packer, Douglas L. , Kapa, Suraj , Mulpuru, Siva K , Asirvatham, Samuel J , Friedman, Paul A , Kapa, Suraj

Mayo Clinic

Journal of Cardiovascular Electrophysiology | July 16, 2019 | Volume: 30 | Issue: 10 | Pages: 1960-1966

10.1111/jce.14068 | PMID 31310387 Get It

AbstractBackgroundThere are few data regarding the outcome of a combined cryo‐ and radiofrequency (RF)‐catheter ablation of various types of supraventricular tachycardias (SVTs) originating from near the normal conduction system.METHODSWe analyzed all patients undergoing combined cryo‐ and RF‐ catheter ablation at Mayo Clinic, Rochester, MN as part of the ablation of SVTs with potential risks of injury to the normal conduction system. This study aimed to assess the outcome of a combined cryo‐ and RF‐catheter ablation of various types of SVTs.RESULTSThe study population consisted of 54 patients (38 ± 17 years, 32 men). A combined cryo‐ and RF‐catheter ablation was attempted for septal accessary pathways (APs) in 26, atrioventricular nodal reentrant tachycardia (AVNRT) in 14, atrial tachycardia (AT) in 7, and junctional ectopic tachycardia in 7 patients. Forty‐one patients (76%) were successfully ablated with cryoablation, and RF ablation after an unsuccessful cryoablation ablated the SVTs successfully at the same location in 6 patients (11%). Complication occurred in 1 patient (deep vein thrombosis). The cumulative freedom from SVT rate at 30 days after the procedure was 78% and there was no significant difference in the recurrence rate among the SVTs.CONCLUSIONA combined cryo‐ and RF‐catheter ablation is clinically effective in patients undergoing SVT ablation with the potential risk of injury to the normal conduction system.
Incidence and outcomes of systemic infections in patients with leadless pacemakers: Data from the Micra IDE study
El‐Chami, Mikhael F. , Soejima, Kyoko , Piccini, Jonathan P. , Reynolds, Dwight, Ritter, Philippe , Okabe, Toshimasa , Friedman, Paul A. , Cha, Yong‐Mei , Stromberg, Kurt , Holbrook, Reece , Fagan, Dedra H. , Roberts, Paul R. , El-Chami, Mikhael F , Stromberg, Kurt

Mayo Clinic

Pacing and Clinical Electrophysiology | June 24, 2019 | Volume: 42 | Issue: 8 | Pages: 1105-1110

10.1111/pace.13752 | PMID 31232461 Get It

AbstractBackgroundThe Micra clinical trials have enrolled more than 2500 patients without any reported device‐related infections that required removal during follow‐up. Leadless pacemakers might be more resistant to bacterial seeding due to smaller surface area and a greater tendency for encapsulation.ObjectiveTo analyze the incidence and outcomes of serious infectious events (SIEs: bacteremia or endocarditis) that developed during follow‐up in patients with history of Micra leadless pacemaker implantation.MethodsSIE and outcomes were characterized based upon adverse event reports. Among 720 patients implanted with Micra in the investigational device exemption trial, we identified 16 patients who had documented 21 SIEs during follow‐up.ResultsAmong patients with SIEs, mean age was 71.9 ± 11.7 years. SIEs occurred at a mean 4.8 ± 4.5 months after implant and patients were followed for 13.1 ± 9.1 months after documentation of SIE. All events were adjudicated as unrelated to the Micra device or procedure. Bacteremia was documented to be related to a gram‐positive organism in 13 events (seven Staphylococcus, three Streptococcus, two Enterococcus, and one uncharacterized gram‐positive bacteria), and gram‐negative organisms in three events. In five events, the type of organism was not characterized (two patients with endocarditis). No persistent cases of bacteremia after antibiotic cessation were seen over the duration of follow‐upConclusionIn this small series of Micra patients who developed SIEs postimplant, the occurrence of bacteremia and/or endocarditis did not appear to lead to persistent bacteremia off antibiotics; most events resolved with antibiotic treatment.
Electrophysiologic effects and outcomes of sympatholysis in patients with recurrent ventricular arrhythmia and structural heart disease
Cai, Cheng , Dai, Mingyan , Tian, Ying , Zhang, Pei , Wittwer, Erica D. , Rho, Richard H., Mulpuru, Siva K. , Lee, Hon‐Chi, Ackerman, Michael J. , Asirvatham, Samuel J. , Munger, Thomas M. , Friedman, Paul A. , Cha, Yong‐Mei , Dai, Ming-Yan, Kapa, Suraj , Mulpuru, Siva K , Asirvatham, Samuel J , Chen, Ming-Long , Friedman, Paul A , Cha, Yong-Mei , Kapa, Suraj , McLeod, Christopher J.

Mayo Clinic

Journal of Cardiovascular Electrophysiology | June 14, 2019 | Volume: 30 | Issue: 9 | Pages: 1499-1507

10.1111/jce.14030 | PMID 31199536 Get It

AbstractIntroductionAutonomic modulation has been used as a therapy to control recurrent ventricular arrhythmia (VA). This study was to explore stellate ganglion block (SGB) effect on cardiac electrophysiologic properties and evaluate the long‐term outcome of cardiac sympathetic denervation (CSD) for patients with recurrent VA and structural heart disease (SHD).Materials and MethodsPatients who had recurrent VA due to SHD were enrolled prospectively. Electrophysiologic study and ventricular tachycardia (VT) induction were performed before and after left and right SGB. VA burden and long‐term outcomes were assessed for a separate patient group who underwent left or bilateral CSD for drug‐refractory VA due to SHD.ResultsElectrophysiologic study of nine patients showed that baseline mean (SD) corrected sinus node recovery time (cSNRT) increased from 320.4 (73.3) ms to 402.9 (114.2) ms after left and 482.4 (95.7) ms after bilateral SGB (P = .03). SGB did not significantly change P‐R, QRS, and Q‐T intervals and ventricular effective refractory period, nor did the inducibility of VA. Nineteen patients underwent left (n = 14) or bilateral (n = 5) CSD. CSD reduced VA burden and appropriate ICD therapies from a median (interquartile range) of 2.5 (0.4‐11.6) episodes weekly to 0.1 (0.0‐2.4) episodes weekly at 6‐month follow‐up (P = .002). Three‐year freedom from orthotopic heart transplant (OHT) and death was 52.6%. New York Heart Association functional class III/IV and VT rate less than 160 beats per minute were predictors of recurrent VA, OHT, and death.ConclusionSGB increased cSNRT without changing heart rate. CSD was more beneficial for patients with mild‐to‐moderate heart failure and faster VA.
Safety and compatibility of smart device heart rhythm monitoring in patients with cardiovascular implantable electronic devices
Abudan, Anas, Isath, Ameesh , Ryan, J. , Henrich, Mark, Dugan, Jennifer , Ladewig, Dorothy J., Friedman, Paul A. , Abudan, Anas A , Ryan, James D , Henrich, Mark J, Dugan, Jennifer L, Dillon, John J, Friedman, Paul A , Attia, Zachi I. , Dillon, John

Mayo Clinic

Journal of Cardiovascular Electrophysiology | June 13, 2019 | Volume: 30 | Issue: 9 | Pages: 1602-1609

10.1111/jce.14024 | PMID 31190453 Get It

AbstractIntroductionEmerging medical technology has allowed for monitoring of heart rhythm abnormalities using smartphone compatible devices. The safety and utility of such devices have not been established in patients with cardiac implantable electronic devices (CIEDs). We sought to assess the safety and compatibility of the Food and Drug Administration‐approved AliveCor Kardia device in patients with CIEDs.Methods and ResultsWe prospectively recruited patients with CIED for a Kardia recording during their routine device interrogation. A recording was obtained in paced and nonpaced states. Adverse clinical events were noted at the time of recording. Electrograms (EGMs) from the cardiac device were obtained at the time of recording to assess for any electromagnetic interference (EMI) introduced by Kardia. Recordings were analyzed for quality and given a score of 3 (interpretable rhythm, no noise), 2 (interpretable rhythm, significant noise) or 1 (uninterpretable). A total of 251 patients were recruited (59% with a pacemaker and 41% with ICD). There were no adverse clinical events noted at the time of recording and no changes to CIED settings. Review of all EGMs revealed no EMI introduced by Kardia. Recordings were correctly interpreted in 90% of paced recordings (183 had a score of 3, 43 of 2, and 25 of 1) and 94.7% of nonpaced recordings (147 of 3, 15 of 2, and 9 of 1).ConclusionThe AliveCor Kardia device has an excellent safety profile when used in conjunction with most CIEDs. The quality of recordings was preserved in this population. The device, therefore, can be considered for heart rhythm monitoring in patients with CIEDs.
Efficacy of Pharmacologic and Cardiac Implantable Electronic Device Therapies in Patients With Heart Failure and Reduced Ejection Fraction
Lee, Justin Z. , Amin, Mustapha, Neville, Matthew R., Almader‐Douglas, Diana , Killu, Ammar M. , Madhavan, Malini , Cha, Yong‐Mei , Asirvatham, Samuel J. , Friedman, Paul A. , Mulpuru, Siva K. , Tseng, Andrew S. , Kunze, Katie L. , Almader-Douglas, Diana, Asirvatham, Samuel J , Gersh, Bernard J.

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | June 4, 2019 | Volume: 12 | Issue: 6 | Pages: No page available

10.1161/circep.118.006951 | PMID 31159582 Get It

Background: The treatment of heart failure with reduced ejection fraction has been the subject of numerous randomized controlled trials involving medications and cardiac implantable electronic device therapies. As newer effective pharmacological therapies suggest significant reductions in all-cause mortality, the role of additional device therapy in heart failure with reduced ejection fraction deserves further scrutiny. Methods: A systematic review and network meta-analysis on the effect of medication and device therapies in heart failure with reduced ejection fraction on all-cause mortality was performed. Randomized controlled trials published between January 1980 and July 2017 were identified using Medline, EMBASE, and Cochrane Controlled Register of Trials databases. Pcnetmeta package in R was used to calculate treatment arm–based estimated rates, rate ratios, and probability ranks with 95% credible intervals. Results: Combination therapy of ACE (angiotensin-converting enzyme) inhibitors or ARBs (angiotensin receptor blockers) with β-blockers (BBs) alone or in addition to implantable cardiac defibrillators or cardiac resynchronization therapy with defibrillators demonstrated a significant reduction of all-cause mortality when compared with placebo. By probability rank, implantable cardiac defibrillator+ACE inhibitor or ARB+BB+mineralocorticoid receptor antagonist, implantable cardiac defibrillator+ACE inhibitor or ARB+BB, and angiotensin receptor-neprilysin inhibitor+BB+mineralocorticoid receptor antagonist combination therapies have the highest probability of being ranked the best treatment. There was no significant difference in the rate of mortality when comparing angiotensin receptor-neprilysin inhibitor+BB+mineralocorticoid receptor antagonist to implantable cardiac defibrillator+optimal pharmacological combination therapy. Conclusions: BB and renin-angiotensin system blockers alone or in combination with defibrillator device therapy have robust evidence for a reduction in mortality compared with placebo. The comparative efficacy of pharmacological therapy with angiotensin receptor-neprilysin inhibitors and device therapy deserves further investigation.
His-bundle pacing: impact of social media
Beer, Dominik , Dandamudi, Gopi, Friedman, Paul A. , Vijayaraman, Pugazhendhi , Mandrola, John M

Mayo Clinic

EP Europace | May 23, 2019 | Volume: 21 | Issue: 10 | Pages: 1445-1450

10.1093/europace/euz169 | PMID 31230085 Get It

Lyme carditis atrioventricular block: management strategies—Authors’ reply
Isath, Ameesh , Padmanabhan, Deepak , Naksuk, Niyada , Kella, Danesh , Friedman, Paul A. , Kella, Danesh K

Mayo Clinic

EP Europace | May 2, 2019 | Volume: 21 | Issue: 8 | Pages: 1282-1282

10.1093/europace/euz111 | PMID 31168567 Get It

Molecular Approach to Diagnosis of Cardiovascular Implantable Electronic Device Infection
Garrigos, Zerelda Esquer , Greenwood‐Quaintance, Kerryl E. , Cunningham, Scott A. , Vijayvargiya, Prakhar , Fida, Madiha , Friedman, Paul A. , Mandrekar, Jayawant N. , Patel, Robin , Esquer Garrigos, Zerelda , Mandrekar, Jayawant, Patel, Robin , Fida, Madiha , Cunningham, Scott A , Sohail, M. Rizwan , DeSimone, Daniel C. , Baddour, Larry M.

Mayo Clinic

Clinical Infectious Diseases | March 26, 2019 | Volume: 70 | Issue: 5 | Pages: 898-906

10.1093/cid/ciz266 | PMID 30944928 Get It

Abstract Background Sonicate fluid (SF), a solution derived from vortexing and sonication of explanted cardiovascular implantable electronic devices (CIEDs), is a higher-yield specimen compared with swabs or tissues for culture-based detection of microorganisms associated with CIED infection. Despite this, SF culture fails to identify a causative organism in ~50% of cases. We aimed to evaluate the diagnostic performance of 16S ribosomal RNA gene (rRNA) polymerase chain reaction (PCR)/sequencing of SF and compare it with that of SF culture. Methods We identified 322 SF specimens from extracted CIEDs and reviewed clinical data for each patient. Subjects were classified as having or not having CIED infection. Cases were subcategorized as culture negative if no significant growth was reported from SF cultures and as culture positive if an organism was detected above predefined thresholds. 16S rRNA PCR/sequencing was performed, with the organisms identified reported according to Clinical and Laboratory Standards Institute guidelines for sequence data interpretation. Results A total of 278 SF samples corresponded to infected cases, of which 160 were culture positive and 118 culture negative. The remaining 44 were from noninfected cases, of which 2 were culture positive. Compared with SF culture, the sensitivity of 16S rRNA PCR/sequencing was higher (64% vs 57.5%, P = .003). 16S rRNA PCR/sequencing detected a potential pathogen in 28 of 118 culture-negative cases, identifying staphylococci in the majority (18/28). Conclusions 16S rRNA PCR/sequencing has higher sensitivity to detect bacteria in SF from extracted CIEDs than does SF culture.
Prospective validation of a deep learning electrocardiogram algorithm for the detection of left ventricular systolic dysfunction
Lopez‐Jimenez, Francisco, Mohan, Tarun L., Pellikka, Patricia A. , Carter, Rickey E. , Shah, Nilay D. , Friedman, Paul A. , Noseworthy, Peter A. , Kapa, Suraj , Yao, Xiaoxi , Friedman, Paul A , Noseworthy, Peter A , Pellikka, Patricia A , Carter, Rickey E , Attia, Zachi I. , Kapa, Suraj , López-Jiménez, Francisco

Mayo Clinic

Journal of Cardiovascular Electrophysiology | March 1, 2019 | Volume: 30 | Issue: 5 | Pages: 668-674

10.1111/jce.13889 | PMID 30821035 Get It

AbstractObjectivesWe sought to validate a deep learning algorithm designed to predict an ejection fraction (EF) less than or equal to 35% based on the 12‐lead electrocardiogram (ECG) in a large prospective cohort.BackgroundPatients undergoing routine ECG may have undetected left ventricular (LV) dysfunction that warrants further echocardiographic assessment. However, identification of these patients can be challenging.MethodsWe applied the algorithm to all ECGs interpreted by the Mayo Clinic ECG laboratory in September 2018. The performance of the algorithm was tested among patients with recent echocardiographic assessments of LV function. We also applied the algorithm in patients with no recent echocardiographic assessments of LV function to determine the rate of new “positive screens.”ResultsAmong 16 056 adult patients who underwent routine ECG, 8600 (age 67.1 ± 15.2 years, 45.6% male), had a transthoracic echocardiogram (TTE) and 3874 patients had a TTE and ECG less than 1 month apart. Among these patients, the algorithm was able to detect an EF less than or equal to 35% with 86.8% specificity, 82.5% sensitivity, and 86.5% accuracy, (area under the curve, 0.918). Among 474 “false‐positives screens,” 189 (39.8%) had an EF of 36% to 50%. Among patients with no prior TTE, the algorithm identified 3.5% of the patients with suspected EF less than or equal to 35%. Exploratory analysis suggests false positives could be reduced by assessing NT‐pro‐BNP after the initial “positive screen.”ConclusionsA deep learning algorithm detected depressed LV function with good accuracy in routine practice. Further studies are needed to validate the algorithm in patients with no prior echocardiogram and to assess the impact on echocardiography utilization, cost, and clinical outcomes.