Abstract Background: Epidemiological and laboratory-based studies have provided conflicting evidence for a role of ghrelin in colorectal cancer development. We conducted two-sample Mendelian randomization (MR) analyses to evaluate evidence for an association of circulating ghrelin and colorectal cancer risk overall and by sex, cancer subsite, and age at diagnosis. Methods: Genetic instruments proxying plasma total ghrelin levels were obtained from a recent genome-wide association study of 54,219 participants. Summary data for colorectal cancer risk were obtained from a recent meta-analysis of several genetic consortia (up to 73,673 cases and 86,854 controls). A two-sample MR approach and several sensitivity analyses were applied. Results: We found no evidence for an association of genetically predicted plasma total ghrelin levels and colorectal cancer risk (0.95, 95% confidence interval, 0.81–1.12; R2 of ghrelin genetic instruments: 4.6%), with similarly null results observed when stratified by sex, anatomical subsite, and for early-onset colorectal cancer. Conclusions: Our study suggests that plasma ghrelin levels are unlikely to have a causal relationship with overall, early-onset, and sex- and cancer subsite–stratified colorectal cancer risk. Impact: This large-scale analysis adds to the growing body of evidence that plasma total ghrelin levels are not associated with colorectal cancer risk.
Optimizing multiple Myeloma clinical trials: research direction, addressing limitations, and strategies for improvement
Psychometric Properties of the Serbian Version of the Arm, Shoulder, and Hand Disability Self-Assessment Questionnaire: Criterion Validity, Construct Validity, and Internal Consistency
Background/Objectives: The Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire is a widely employed self-report tool for assessing upper extremity function. The aim of this study was to assess the psychometric properties of the Serbian version of the DASH by determining its criterion and construct validity, as well as internal consistency. Methods: This cross-sectional study was conducted among patients with hand and wrist disabilities at the Institute for Orthopedics “Banjica”, Serbia. The psychometric properties of the Serbian version of the DASH were analyzed through an examination of its factorial structure and internal consistency. The DASH consists of 30 items, 24 of which assess function, 21 of which focus on physical function and three on social/role function. The remaining six items evaluate symptoms related to pain, tingling/numbness, weakness, and stiffness. Results: A total of 297 patients were included in the study. The mean age was 47.4 ± 16.8 years, with 50.5% males. Three models were assessed to determine the reliability and validity of the questionnaire across different domains. Model 1 examined a single-factor structure. In Model 2, the items were divided into two domains: Physical Function and Psychosocial/Symptoms. In Model 3, items were subdivided into three domains: Physical Function, Symptoms, and Psychosocial. All models demonstrated an excellent internal consistency with a Cronbach’s alpha > 0.9 for most domains. The values for the fit indices Tucker–Lewis index (TLI) and Comparative-Fit Index (CFI) were above their cut-off criteria of 0.9, while the Root Mean Square Error of Approximation (RMSEA) and Standardized Root Mean Square Residual (SRMR) were below the suggested value of 0.06, indicating an excellent level of models fit. Standardized factor loadings were statistically significant (p < 0.05). Conclusions: The present study provided the evidence for the appropriate metric properties of the Serbian version of the DASH. Results support both the unidimensional and multidimensional structures of the DASH.
Molecular Markers in the World Health Organization Classification of Head and Neck Tumors, Fifth Edition
B-203 Advancing Equity, Inclusion, and Diversity in Genetic Testing: Disparities in Detection Rates and Access to Carrier Screening Among 8,000 Patients Nationwide
Abstract Background Professional medical societies recommend that carrier screening for 113 different genetic disorders be offered during pregnancy or preconception to all individuals, regardless of ancestry, in order to provide more equitable opportunities for patients to ascertain their reproductive risks. In our clinical laboratory experience, however, the vast majority of healthcare providers continue to order carrier screening for only cystic fibrosis (CF), which is disproportionately common in white individuals of Northern European descent. Our highest volume CF screening test is performed on >10,500 diverse patients per year and utilizes a targeted genotyping array that detects >500 variants in CFTR and >1200 variants in >150 other pertinent genes. Here we report the inequities in diagnostic yield among our first 8,000 patients for whom only limited testing was ordered and examine the barriers to widespread adoption of more inclusive carrier screening. Methods Three carrier screening options (CF, CF+spinal muscular atrophy [SMA], CF+SMA+fragile X syndrome [FXS]+hemoglobinopathies) were ordered clinically and performed on DNA extracted from 8,000 whole blood samples from unique individuals utilizing a custom SNP array (Thermo Fisher GeneTitanTM platform) designed to detect >1700 pathogenic variants in 218 different genes. Data was retrospectively reviewed to determine overall detection rates for carriers of all recommended conditions vs. only the condition(s) included in the originally ordered service. Finally, reproductive health providers at nine different ordering sites across the U.S. were interviewed regarding their current carrier screening practices. Results Patients were referred for testing by 119 different clinical facilities. 98.1% (7847/8000) had CF-only testing ordered, 1.2% (99/8000) had CF+SMA testing ordered, and 0.68% (54/8000) had testing for CF+SMA+FXS+hemoglobinopathies ordered. 7.1% (568/8000) of patients had reportable variants in CFTR. Had CF+SMA testing been ordered on all 8,000 patients, however, the diagnostic yield would have been 8.9%. Of the patients who had CF-only or CF+SMA testing ordered, 11.9% (943/7946) were found to be carriers of hemoglobinopathies. Finally, had all 8000 patients had testing for all currently recommended targets on the panel, the diagnostic yield would have increased to 55% (4396/8000). Ordering providers at 9/50 different contacted sites agreed to interview requests. 100% (9/9) of respondents indicated that their patients experience significant disparities in access to carrier screening, and that the primary cause of these inequities was insufficient insurance reimbursement. 67% (6/9) of respondents indicated that >50% of their patient population identified as non-white and would have “very strongly” benefitted from “testing for other disorders beyond CF.” Conclusions Despite clinical practice guidelines urging for more population-neutral carrier screening, major gaps exist between what is recommended versus ultimately ordered. This significantly limits the clinical utility of testing, especially in patients from underrepresented backgrounds. Improved insurance coverage for more inclusive carrier screening is needed to help reduce such disparities.
B-019 Reduction in Culture Media Costs, without Impacting Turnaround Time, Through Implementation of an Automated Microbiology Platform and Gram Stain Interpretation
Abstract Background Automated plating instruments have been shown to improve quality in Microbiology laboratories in a number of ways including consistent streaking patterns that provide better isolation of bacterial colonies compared to manual methods. The time per culture set up and automated camera imaging is dependent upon the amount of media set, such that more individual plates slow down turn around time. Conversely, smaller media surface area and the use of non-selective media may result in mixed colonies that require sub-culture for isolation before identification and susceptibilities can be performed. Based upon these findings, we attempted to reduce our media usage per culture with the implementation of automation, with the goal of using as few plates as possible while at the same time not negatively impacting the turn around time of the culture via the need to subculture poorly isolated colonies. We conducted a pre-and post-implementation study evaluating the costs per culture and turn around time delays related to subculturing in a subset. Methods In the pre-implementation period, from April-January 2023, three individual media plates (sheep blood agar, chocolate agar and CNA/MacConkey bi-plate) were routinely set for general aerobic bacterial culture sources including swabs and body fluids. In the post implementation period, from April-January 2024, a single sheep blood/chocolate agar bi-plate was set unless the gram stain showed evidence of mixed organisms (defined as more than one morphology) at which time a secondary selective media (CNA/MacConkey) was manually set. For urine cultures, in the pre-implementation period 2 plates were set (sheep blood and CNA/MacConkey bi-plate) and in the post-implementation period a single chromogenic agar/sheep blood bi-plate was set. Total numbers of cultures in both periods were collected as well as the number of cultures for which additional media were set based on gram stain results. Orders of subculture media in the laboratory information system were compared per positive cultures. Statistical analysis was performed in GraphPad Prism. Results In the pre- versus post-implementation periods, a total of 16,454 vs 17,782 general aerobic cultures and 50,680 vs 53,916 urine cultures were set, respectively. Only 3.6% of general cultures required additional media set based on gram stain. The difference in cost between pre- and post-implementation was approximately a two-thirds reduction in cost for general cultures and a 25% reduction for urine cultures, with a total savings of approximately $34,238 in media avoidance in the post-implementation period. The frequency of positive cultures requiring subculture was not significantly different between the pre- (average 36% of positive growth) and post-implementation (average 22% of positive growth) periods for both culture types and may actually have been reduced due to automation. Conclusions The implementation of reduced media concomitant with streaking via automation resulted in significant cost savings while not negatively impacting isolation, which in turn impacts culture turn around times. The automation may have reduced need for subculture, perhaps due to better isolation, thus subsequent analyses will explore this additional finding.
A-301 Evaluation of Second-Generation Visby Medical Sexual Health Point-of-Care Test: Clinical Concordance, Analytical Error Rates, and Result Turnaround Time
Abstract Background Rapid testing for Neisseria gonorrhoeae, Chlamydia trachomatis, and Trichomonas vaginalis may be useful for antibiotic stewardship initiatives. Our institution recently implemented the second-generation Visby Medical Sexual Health Test (Visby Gen2) for rapid diagnosis of STIs in our emergency department. Here we (1) compared result concordance of the (Visby Gen2) to the first-generation Visby Medical Sexual Health Click Test (Visby Gen1), (2) compared assay failure rates of the Visby Gen1 to Gen2 tests, and (3) compared result turnaround time (TAT) for clinically ordered rapid STI tests to central laboratory STI results. Methods Accuracy was assessed using residual clinical samples in Aptima buffer submitted for routine molecular STI testing (C. trachomatis, N. gonorrhoeae, and T. vaginalis) in the central laboratory on the Panther platform (Hologic). Aptima samples were diluted 1:33 in Visby collection buffer prior to testing on the Visby cartridge. Clinically reported results were used as reference results. Diluted samples with discordant results were re-tested on the reference method and the result from the dilution was used in calculations. Assay failure rates were calculated as the number of failed assays compared to the total assays performed. TAT for rapid and central lab testing was calculated as time of sample received in laboratory to time verified in laboratory information system. Results For Visby Gen1 we observed negative concordance of 100% (41/41) for C. trachomatis, 97.5% (39/40) for N. gonorrhoeae, and 97.1% (34/35) for T. vaginalis. Positive concordance was 91.7% (11/12) for C. trachomatis, 100% (11/11) for N. gonorrhoeae, and 100% (17/17) for T. vaginalis. For Visby Gen1 we observed a 10.5% (12/114) cartridge failure rate. For Visby Gen2, we observed negative concordance of 100% (59/59) for C. trachomatis, 100% (63/63) for N. gonorrhoeae, and 100% (55/55) for T. vaginalis while positive concordance was 100% (10/10) for C. trachomatis, 100% (6/6) for N. gonorrhoeae, and 90.9% (10/11) for T. vaginalis. The Visby Gen2 assay displayed a 4.9% (4/81) cartridge failure rate. Six weeks after implementing the Visby Gen2 assay in our ED, rapid STI panel TAT was 0.48 hours on average (n=20). In the central laboratory the average TAT was 22.31 hours (n=7892). Conclusions Assay concordance to reference method was similar for Visby Gen1 and Gen2 assays. The cartridge failure rate improved by 46.7% with the Gen2 assay which should decrease the need to repeat testing due to assay failure. Result TAT decreased by 97.8% when comparing rapid Visby results to central laboratory. Therefore, Visby STI testing using the Gen2 assay can provide accuracy and rapid results likely to facilitate more rapid patient management.
A-162 Improved Laboratory Workflow using Automated Detection of Hemolysis, Icterus, and Lipemia for Coagulation Testing
Abstract Background Managing preanalytical variables is critical to providing quality laboratory test results. However, this can be a challenge for laboratory staff, particularly with manual detection of interfering substances and complicated workflows. For coagulation testing, we assess specimen integrity and acceptability by visual checks and quantification of interfering substance on a chemistry analyzer. To improve this subjective process, we evaluated the technical performance of a new model of coagulation analyzer with automated preanalytical specimen integrity detection. Our objective was to determine if we could reduce the number of specimens requiring visual inspection/off-analyzer interference testing in order to simplify our testing workflow. Methods Citrated plasma specimens received in the Hospital Clinical Laboratory at Mayo Clinic (Rochester, MN) were tested on the TOP ACL 500 or TOP ACL 550 Series Coagulation analyzers (Werfen, Boston, MA) according to manufacturer’s instruction. Specimens tested on the TOP 500 were visually inspected for hemolysis, icterus, and lipemia (HIL). If the technologist detected a possible interferent, an aliquot of plasma was analyzed on our cobas c501 chemistry analyzer (c501) (Roche Diagnostics, Indianapolis, IN) to obtain HIL values. Laboratory-established or manufacturer-defined interference thresholds were applied in determining specimen acceptability. For samples tested on the TOP 550, specimen integrity was assessed by the instrument’s automated interference detection module. The analyzer reported HIL as an “interference cloud” or estimated range, rather than a single value like the c501. HIL values were estimated by visual assessment of the low end of the “interference cloud”. Values were confirmed on the c501 only for specimens with an “interference cloud” at/exceeding the test-specific interference thresholds. We analyzed data from a 2-month period pre- (TOP 500) and post-implementation (TOP 550). The percent of specimens requiring quantitation/confirmation on the c501 was calculated. Statistical significance was calculated using the Chi-squared test where significance was defined as p<0.01. Correlation between c501 and TOP 550 estimated HIL values was evaluated. Results A total of 2.2% (171/7605) and 1.3% (113/8983) of specimens tested on the TOP 500 and TOP 550, respectively, required HIL measurements on the c501 (p<0.001). Of those samples, 8.2% (14/171) and 14.2% (16/113) from the TOP 500 and TOP 550, respectively, had HIL values above the interference thresholds and were rejected by the laboratory. Comparison of the estimated HIL values from the “interference cloud” and from the c501 resulted in slopes (Pearson correlation coefficients) of: H 1.56 (0.77), I 0.67 (0.97), and L 1.35 (0.99). Conclusions In comparison to our workflow with visual assessment of interference, use of the automated interference detection functionality on the TOP 550 instrument resulted in a lower percentage of specimens requiring HIL measurements on the chemistry analyzer. Agreement between interference measurements obtained on the c501 and the TOP 550 was moderate where TOP 550 overestimated the degree of hemolysis and lipemia and underestimated icterus. Implementation of automated interference detection on the TOP 550 analyzer improved our workflow by eliminating the need for tedious and subjective visual checks and reducing the percentage of specimens requiring additional HIL measurements.
A-211 Lipids in the Afternoon: Effect on LDL-C, Triglycerides, and Collection Time When Removing Fasting Requirements for Lipid Panels
Abstract Background Calculated LDL cholesterol (LDL-C) is a standard component of the lipid panel and an important risk factor in managing atherosclerotic cardiovascular disease (ASCVD). Due to the assumptions in the derivation of the Friedwald formula, fasting (≥8 hours) and triglyceride levels ≤400mg/dL have long been recommended. More recent data have shown that in most cases fasting has minimal effect on results, leading to the endorsement of non-fasting lipid panels for routine evaluation of ASCVD risk in clinical practice guidelines. Furthermore, newer equations (e.g. Sampson-NIH) allow for more accurate estimation of LDL-C even in the presence of hypertriglyceridemia. Mayo Clinic has implemented the Sampson-NIH LDL-C calculation and removed fasting/non-fasting designation from lipid panel orders. We hypothesized that the change to fasting designation would allow more afternoon draws for routine lipid panels and that increased non-fasting collections may increase triglyceride levels, but that the Sampson-NIH equation would prevent bias in LDL-C estimation. In order to test these hypotheses, we analyzed patient data from 1 year prior and 1 year post-implementation. Methods Results of lipid panels performed for one year preceding (n=334,719) and one year after (n=381,804) removal of the fasting/non-fasting designation and implementation of Sampson-NIH equation were collected. Median, 10th, and 90th percentile of draw time, triglyceride, and LDL-C calculated by either Sampson-NIH or Friedwald formulas were compared by quantile regression. Results Draw times shifted post-implementation at the 10th percentile (7:06 vs. 7:10, p<0.0001), median (8:49 vs. 9:08, p<0.0001) and 90th (12:02 vs. 13:46, p<0.0001). No difference in median triglyceride measurement was observed between pre-and post-implementation (110mg/dL), but slight differences were observed in the 10th and 90th percentile values (60 vs 59mg/dL and 224 vs 229mg/dL, p<0.0001). No difference was observed in 10th, 50th, or 90th percentile LDL values when calculated by Sampson-NIH equation (56, 99, 153mg/dL); however, if the Friedwald formula is used, a slight shift is observed in the 10th and 50th percentile LDL values (54 vs. 53, 97 vs. 96; p<0.0001) but not the 90th (150mg/dL). Conclusions Changing to the Sampson/NIH formula for LDL-C and removing fasting vs. non-fasting designation from routine lipid panels had minimal effect on reported triglyceride and LDL-C values, while allowing increased flexibility in draw time and reporting of LDL-C on patients with triglycerides ≥400mg/dL. Patients with TG ≥400mg/dL represented 1.7% of the dataset overall, including 5,387 patients before the change in which LDL-C could not be reported and 6,697 patients in the year post-implementation for whom LDL-C was reported based on the Sampson-NIH formula. Using an equation that is robust in patients with elevated triglyceride levels and removing fasting requirements from routine lipid panels allows greater flexibility and convenience for patients while allowing for more even distribution of phlebotomy workload and reporting of LDL-C results for patients with hypertriglyceridemia without evidence of clinically significant bias in reported results.
Workplace Violence Against Emergency Medical Services (EMS): A Prospective 12-Month Cohort Study Evaluating Prevalence and Risk Factors Within a Large, Multistate EMS Agency