Citations

Clear

4511 citation(s) found for "Scott, C".

Agitation Techniques to Enhance Drainage of Retained Hemothorax
Makey, Ian A. , Das, Nitin A. , Jacob, Samuel , Ahmed, Magdy M. El‐Sayed , Makey, Colleen M. , Johnson, Scott B., Thomas, Mathew , Thomas, Mathew , Thomas, Mathew , Makey, Ian , Makey, Colleen M., Johnson, Scott

Mayo Clinic

Surgical Innovation | December 18, 2020 | Volume: 28 | Issue: 5 | Pages: 544-551

10.1177/1553350620978002 | PMID 33339490 Get It

Background. Retained hemothorax (RH) is a common problem in cardiothoracic and trauma surgery. We aimed to determine the optimum agitation technique to enhance thrombus dissolution and drainage and to apply the technique to a porcine-retained hemothorax. Methods. Three agitation techniques were tested: flush irrigation, ultrasound, and vibration. We used the techniques in a benchtop model with tissue plasminogen activator (tPA) and pig hemothorax with tPA. We used the most promising technique vibration in a pig hemothorax without tPA. Statistics. We used 2-sample t tests for each comparison and Cohen d tests to calculate effect size (ES). Results. In the benchtop model, mean drainages in the agitation group and control group and the ES were flush irrigation, 42%, 28%, and 2.91 ( P = .10); ultrasound, 35%, 27%, and .76 ( P = .30); and vibration, 28%, 19%, and 1.14 ( P = .04). In the pig hemothorax with tPA, mean drainages and the ES of each agitation technique compared with control (58%) were flush irrigation, 80% and 1.14 ( P = .37); ultrasound, 80% and 2.11 ( P = .17); and vibration, 95% and 3.98 ( P = .06). In the pig hemothorax model without tPA, mean drainages of the vibration technique and control group were 50% and 43% (ES = .29; P = .65). Discussion. In vitro studies suggested flush irrigation had the greatest effect, whereas only vibration was significantly different vs the respective controls. In vivo with tPA, vibration showed promising but not statistically significant results. Results of in vivo experiments without tPA were negative. Conclusion. Agitation techniques, in combination with tPA, may enhance drainage of hemothorax.
Burosumab for the Treatment of Tumor-Induced Osteomalacia
Miller, Paul D. , Weber, Thomas J. , Peacock, Munro , Rauch, Frank , Luca, Diana, Cimms, Tricia, Roberts, Mary Scott , Insogna, Karl , Beur, Suzanne M. Jan de , Kumar, Rajiv , Martín, Javier San , Carpenter, Thomas O

Mayo Clinic

Journal of Bone and Mineral Research | December 18, 2020 | Volume: 36 | Issue: 4 | Pages: 627-635

10.1002/jbmr.4233 | PMID 33338281 Get It

ABSTRACT Tumor-induced osteomalacia (TIO) is caused by phosphaturic mesenchymal tumors producing fibroblast growth factor 23 (FGF23) and is characterized by impaired phosphate metabolism, skeletal health, and quality of life. UX023T-CL201 is an ongoing, open-label, phase 2 study investigating the safety and efficacy of burosumab, a fully human monoclonal antibody that inhibits FGF23, in adults with TIO or cutaneous skeletal hypophosphatemia syndrome (CSHS). Key endpoints were changes in serum phosphorus and osteomalacia assessed by transiliac bone biopsies at week 48. This report focuses on 14 patients with TIO, excluding two diagnosed with X-linked hypophosphatemia post-enrollment and one with CSHS. Serum phosphorus increased from baseline (0.52 mmol/L) and was maintained after dose titration from week 22 (0.91 mmol/L) to week 144 (0.82 mmol/L, p < 0.0001). Most measures of osteomalacia were improved at week 48: osteoid volume/bone, osteoid thickness, and mineralization lag time decreased; osteoid surface/bone surface showed no change. Of 249 fractures/pseudofractures detected across 14 patients at baseline, 33% were fully healed and 13% were partially healed at week 144. Patients reported a reduction in pain and fatigue and an increase in physical health. Two patients discontinued: one to treat an adverse event (AE) of neoplasm progression and one failed to meet dosing criteria (receiving minimal burosumab). Sixteen serious AEs occurred in seven patients, and there was one death; all serious AEs were considered unrelated to treatment. Nine patients had 16 treatment-related AEs; all were mild to moderate in severity. In adults with TIO, burosumab exhibited an acceptable safety profile and was associated with improvements in phosphate metabolism and osteomalacia. © 2020 The Authors. Journal of Bone and Mineral Research published by American Society for Bone and Mineral Research..
436: A Rare Cause of Hypercapnic Respiratory Failure: Hypothyroid Myopathy
Lugo‐Fagundo, Nahyr , Shah, Kejal, Nelson, Lauren Hassan, Turcano, Pierpaolo , Moss, John, Helgeson, Scott A. , Nelson, Lauren Juliette Hassan, Moss, John E. , Chaudhary, Sanjay , Guru, Pramod

Mayo Clinic

Critical Care Medicine | December 18, 2020 | Volume: 49 | Issue: 1 | Pages: 208-208

10.1097/01.ccm.0000727632.06388.79 Get It

947: Operability of a Drape With Port Connection as a Barrier for Aerosol-Generating Procedures
Oman, Sven P. , Lowman, Philip, Sanghavi, Devang , Helgeson, Scott A. , Franco, Pablo Moreno

Mayo Clinic

Critical Care Medicine | December 18, 2020 | Volume: 49 | Issue: 1 | Pages: 471-471

10.1097/01.ccm.0000729676.64250.8e Get It

904: Bivalirudin Anticoagulation Dosing and Monitoring Protocol for Extracorporeal Membrane Oxygenation
Zhao, Yanjun , Nei, Scott D. , Seelhammer, Troy G.

Mayo Clinic

Critical Care Medicine | December 18, 2020 | Volume: 49 | Issue: 1 | Pages: 449-449

10.1097/01.ccm.0000729504.42022.81 Get It

Development of a Quality Improvement Learning Collaborative to Improve Pediatric Sepsis Outcomes
Larsen, Gitte , Brilli, Richard J., Macias, Charles G. , Niedner, Matthew , Auletta, Jeffery J. , Balamuth, Fran , Campbell, Deborah, Depinet, Holly, Frizzola, Meg , Hueschen, Leslie A. , Lowerre, Tracy, Mack, Elizabeth H. , Paul, Raina, Razzaqi, Faisal, Schafer, Melissa , Scott, Halden F. , Silver, Pete, Wathen, Beth, Lukasiewicz, Gloria, Stuart, Jayne, Riggs, Ruth , Richardson, Troy , Ward, Lowrie, INVESTIGATORS, ON BEHALF OF THE IMPROVING PEDIATRIC SEPSIS OUTCOMES COLLABORATIVE, Auletta, Jeffery J , Silver, Pete, Huskins, W. Charles , INVESTIGATORS, ON BEHALF OF THE IMPROVING PEDIATRIC SEPSIS OUTCOMES COLLABORATIVE

Mayo Clinic

Pediatrics | December 16, 2020 | Volume: 147 | Issue: 1 | Pages: No page available

10.1542/peds.2020-1434 | PMID 33328337 Get It

Pediatric sepsis is a major public health problem. Published treatment guidelines and several initiatives have increased adherence with guideline recommendations and have improved patient outcomes, but the gains are modest, and persistent gaps remain. The Children’s Hospital Association Improving Pediatric Sepsis Outcomes (IPSO) collaborative seeks to improve sepsis outcomes in pediatric emergency departments, ICUs, general care units, and hematology/oncology units. We developed a multicenter quality improvement learning collaborative of US children’s hospitals. We reviewed treatment guidelines and literature through 2 in-person meetings and multiple conference calls. We defined and analyzed baseline sepsis-attributable mortality and hospital-onset sepsis and developed a key driver diagram (KDD) on the basis of treatment guidelines, available evidence, and expert opinion. Fifty-six hospital-based teams are participating in IPSO; 100% of teams are engaged in educational and information-sharing activities. A baseline, sepsis-attributable mortality of 3.1% was determined, and the incidence of hospital-onset sepsis was 1.3 cases per 1000 hospital admissions. A KDD was developed with the aim of reducing both the sepsis-attributable mortality and the incidence of hospital-onset sepsis in children by 25% from baseline by December 2020. To accomplish these aims, the KDD primary drivers focus on improving the following: treatment of infection; recognition, diagnosis, and treatment of sepsis; de-escalation of unnecessary care; engagement of patients and families; and methods to optimize performance. IPSO aims to improve sepsis outcomes through collaborative learning and reliable implementation of evidence-based interventions.
Conversion of left atrial volume to diameter for automated estimation of sudden cardiac death risk in hypertrophic cardiomyopathy
Bhopalwala, Huzefa , Dewaswala, Nakeya , Welper, James M., Akinnusotu, Oluwatoyin, Bos, J. Martijn , Ommen, Steve R. , Ackerman, Michael J. , Pellikka, Patricia A. , Geske, Jeffrey B. , Arruda‐Olson, Adelaide M. , Liu, Sijia , Bos, Johan Martijn, Arruda-Olson, Adelaide M , Pellikka, Patricia A , Bos, Johan M , Geske, Jeffrey B , Scott, Christopher G. , Noseworthy, Peter A.

Mayo Clinic

Echocardiography | December 16, 2020 | Volume: 38 | Issue: 2 | Pages: 183-188

10.1111/echo.14943 | PMID 33325582 Get It

AbstractBackgroundA subset of patients with hypertrophic cardiomyopathy (HCM) is at high risk of sudden cardiac death (SCD). Practice guidelines endorse use of a risk calculator, which requires entry of left atrial (LA) diameter. However, American Society of Echocardiography (ASE) guidelines recommend the use of LA volume index (LAVI) for routine quantification of LA size. The aims of this study were to (a) develop a model to estimate LA diameter from LAVI and (b) evaluate whether substitution of measured LA diameter by estimated LA diameter derived from LAVI reclassifies HCM‐SCD risk.MethodsThe study cohort was comprised of 500 randomly selected HCM patients who underwent transthoracic echocardiography (TTE). LA diameter and LAVI were measured offline using digital clips from TTE. Linear regression models were developed to estimate LA diameter from LAVI. A European Society of Cardiology endorsed equation estimated SCD risk, which was measured using LA diameter and estimated LA diameter derived from LAVI.ResultsThe mean LAVI was 48.5 ± 18.8 mL/m2. The derived LA diameter was 45.1 mm (SD: 5.5 mm), similar to the measured LA diameter (45.1 mm, SD: 7.1 mm). Median SCD risk at 5 years estimated by measured LA diameter was 2.22% (interquartile range (IQR): 1.39, 3.56), while median risk calculated by estimated LA diameter was 2.18% (IQR: 1.44, 3.52). 476/500 (95%) patients maintained the same risk classification regardless of whether the measured or estimated LA diameter was used.ConclusionsSubstitution of measured LA diameter by estimated LA diameter in the HCM‐SCD calculator did not reclassify risk.
Detection of Bleeding Complications After Renal Transplant Biopsy
Patel, Anika G. , Young, Scott W. , Dahiya, Nirvikar , Young, Scott W , Kriegshauser, J. Scott , Patel, Maitray D.

Mayo Clinic

American Journal of Roentgenology | December 16, 2020 | Volume: 216 | Issue: 2 | Pages: 428-435

10.2214/ajr.20.22990 | PMID 33325737 Get It

Spontaneous Formation of Melanin from Dopamine in the Presence of Iron
Hedges, David M. , Yorgason, Jordan T. , Perez, Andrew W., Schilaty, Nathan D. , Williams, Benjamin M. , Watt, Richard K. , Steffensen, Scott C. , Schilaty, Nathan D , Yorgason, Jordan T , Steffensen, Scott C , Perez, Andrew W.

Mayo Clinic

Antioxidants | December 16, 2020 | Volume: 9 | Issue: 12 | Pages: 1285

10.3390/antiox9121285 | PMID 33339254 Get It

Parkinson’s disease is associated with degeneration of neuromelanin (NM)-containing substantia nigra dopamine (DA) neurons and subsequent decreases in striatal DA transmission. Dopamine spontaneously forms a melanin through a process called melanogenesis. The present study examines conditions that promote/prevent DA melanogenesis. The kinetics, intermediates, and products of DA conversion to melanin in vitro, and DA melanogenesis under varying levels of Fe3+, pro-oxidants, and antioxidants were examined. The rate of melanogenesis for DA was substantially greater than related catecholamines norepinephrine and epinephrine and their precursor amino acids tyrosine and l-Dopa as measured by UV-IR spectrophotometry. Dopamine melanogenesis was concentration dependent on the pro-oxidant species and Fe3+. Melanogenesis was enhanced by the pro-oxidant hydrogen peroxide (EC50 = 500 μM) and decreased by the antioxidants ascorbate (IC50 = 10 μM) and glutathione (GSH; IC50 = 5 μM). Spectrophotometric results were corroborated by tuning a fast-scan cyclic voltammetry system to monitor DA melanogenesis. Evoked DA release in striatal brain slices resulted in NM formation that was prevented by GSH. These findings suggest that DA melanogenesis occurs spontaneously under physiologically-relevant conditions of oxidative stress and that NM may act as a marker of past exposure to oxidative stress.
Rapid measurement of the low contrast detectability of CT scanners
Omigbodun, Akinyinka , Vaishnav, J. Y., Hsieh, Scott S. , Vaishnav, J. Y.

Mayo Clinic

Medical Physics | December 16, 2020 | Volume: 48 | Issue: 3 | Pages: 1054-1063

10.1002/mp.14657 | PMID 33325033 Get It

PurposeLow contrast detectability (LCD) is a metric of fundamental importance in computed tomography (CT) imaging. In spite of this, its measurement is challenging in the context of nonlinear data processing. We introduce a new framework for objectively characterizing LCD with a single scan of a special‐purpose phantom and automated analysis software. The output of the analysis software is a “machine LCD” metric which is more representative of LCD than contrast‐noise ratio (CNR). It is not intended to replace human observer or model observer studies.MethodsFollowing preliminary simulations, we fabricated a phantom containing hundreds of low‐contrast beads. These beads are acrylic spheres (1.6 mm, net contrast ~10 HU) suspended and randomly dispersed in a background matrix of nylon pellets and isoattenuating saline. The task was to search for and localize the beads. A modified matched filter was used to automatically scan the reconstruction and select candidate bead localizations of varying confidence. These were compared to bead locations as determined from a high‐dose reference scan to produce free‐response ROC curves. We compared iterative reconstruction (IR) and filtered backpropagation (FBP) at multiple dose levels between 40 and 240 mAs. The scans at 60, 120, and 180 mAs were performed three times each to estimate uncertainty.ResultsExperimental scans demonstrated the feasibility of our technique. Our metric for machine LCD was the area under the exponential transform of the FROC curve (AUC). AUC increased monotonically from 0.21 at 40 mAs to 0.84 at 240 mAs. The sample standard deviation of AUC was approximately 0.02. This measurement uncertainty in AUC corresponded to a change in tube current of 4% to 8%. Surprisingly, we found that AUCs for IR were slightly worse than AUCs for FBP. While the phantom was sufficient for these experiments, it contained small air bubbles and alternative fabrication methods will be necessary for widespread utilization.ConclusionsIt is feasible to measure machine LCD using a search task on a phantom with hundreds of beads and to obtain tight error bars using only a single scan. Our method could facilitate routine quality assurance or possibly enable comparisons between different protocols and scanners.