Citations

Clear

344 citation(s) found for "Pham, Si".

REN3: Percutaneous Axillary Temporary Mechanical Support Improves Renal Function Prior To Heart Transplantation In Patients With Chronic Kidney Disease
Jang, Ji-Min, Nativí, Jose, Patel, Parag C. , Leoni, Juan , Yip, Daniel , Sareyyüpoğlu, Başar , Landolfo, Kevin , Leoni, Juan Carlos , Pham, Si M. , Goswami, Rohan

Mayo Clinic

ASAIO Journal | June 16, 2022 | Volume: 68 | Issue: Supplement 2 | Pages: 89-89

10.1097/01.mat.0000841208.11864.3b Get It

Is There Clinically Relevant Plasma Interference with ELISA Detection of APS Antibodies? Reproducibility of Real-World Paired Serum and Plasma Testing
Pham, Michael M. , Orsolini, Giovanni , Crowson, Cynthia S. , Snyder, Melissa R. , Pruthi, Rajiv K. , Moder, Kevin G.

Mayo Clinic

Thrombosis and Haemostasis | June 13, 2022 | Volume: 122 | Issue: 11 | Pages: 1948-1950

10.1055/a-1874-8548 | PMID 35697257 Get It

APOE ε4 influences medial temporal atrophy and tau deposition in atypical Alzheimer's disease
Singh, Neha Atulkumar , Tosakulwong, Nirubol , Graff‐Radford, Jonathan , Pham, Nha Trang Thu, Sintini, Irene , Weigand, Stephen D. , Senjem, Matthew L. , Carrasquillo, Minerva M. , Ertekin‐Taner, Nilüfer , Lowe, Val J. , Josephs, Keith A. , Whitwell, Jennifer L. , Senjem, Matthew L , Singh, Neha Atulkumar , Machulda, Mary M. , Schwarz, Christopher G. , Carrasquillo, Minerva M. , Jack, Clifford R.

Mayo Clinic

Alzheimer's & Dementia | June 12, 2022 | Volume: 19 | Issue: 3 | Pages: 784-796

10.1002/alz.12711 | PMID 35691047 Get It

AbstractIntroductionApolipoprotein E (APOE) ε4 is an important genetic risk factor for typical Alzheimer's disease (AD), influencing brain volume and tau burden. Little is known about its influence in atypical presentations of AD.MethodsAn atypical AD cohort of 140 patients diagnosed with either posterior cortical atrophy or logopenic progressive aphasia underwent magnetic resonance imaging and positron emission tomography. Linear mixed effects models were fit to assess the influence of APOE ε4 on cross‐sectional and longitudinal regional metrics.ResultsAt baseline, APOE ε4 carriers had smaller hippocampal and amygdala volumes and greater tau standardized uptake volume ratio in the hippocampus and entorhinal cortex compared to non‐carriers while longitudinally, APOE ε4 non‐carriers showed faster rates of atrophy and tau accumulation in the entorhinal cortex, with faster tau accumulation in the hippocampus.DiscussionAPOE ε4 influences patterns of neurodegeneration and tau deposition and was associated with more medial temporal involvement, although there is evidence that non‐carriers may be catching up over time.
Automated detection of low ejection fraction from a one-lead electrocardiogram: application of an AI algorithm to an electrocardiogram-enabled Digital Stethoscope
Attia, Zachi I. , Dugan, Jennifer , Rideout, Adam, Venkatraman, Subramaniam, Guo, Ling, Noseworthy, Peter A. , Pellikka, Patricia A. , Pham, Steve L, Friedman, Paul A. , Noseworthy, Peter A , Pellikka, Patricia A , Kapa, Suraj , Lopez-Jimenez, Francisco , Attia, Zachi I , Dugan, Jennifer , Maidens, John , Pham, Steve, Kapa, Suraj , López-Jiménez, Francisco

Mayo Clinic

European Heart Journal - Digital Health | May 23, 2022 | Volume: 3 | Issue: 3 | Pages: 373-379

10.1093/ehjdh/ztac030 | PMID 36712160 Get It

Abstract Aims Electrocardiogram (ECG)-enabled stethoscope (ECG-Scope) acquires a single-lead ECGs during cardiac auscultation and may facilitate real-time screening for pathologies not routinely identified by cardiac auscultation alone. We previously demonstrated an artificial intelligence (AI) algorithm can identify left ventricular dysfunction (LVSD) [defined as ejection fraction (EF) ≤ 40%] with an area under the curve (AUC) of 0.91 using a 12-lead ECG. Methods and results One hundred patients referred for clinically indicated echocardiography were prospectively recruited. ECG-Scope recordings with the patient supine and sitting were obtained in multiple electrode locations at the time of the echocardiogram. The AI algorithm for the detection of LVSD was retrained using single leads from ECG-12 and validated against ECG-Scope to determine accuracy for low EF detection (≤35%, <40%, or <50%). We evaluated the algorithm with respect to body position and lead location. Amongst 100 patients (aged 61.3 ± 13.8; 61% male, BMI: 30.0 ± 5.4), eight had EF≤40%, and six had EF 40–50%. The best single recording position was V2 with the patient supine [AUC: 0.88 (CI: 0.80–0.97) for EF≤35%, 0.85 (CI: 0.75–0.95) for EF≤40%, and 0.81 (CI: 0.71–0.90) for EF < 50%]. When using an AI model to select the recording automatically, AUC was 0.91 (CI: 0.84–0.97) for EF≤35%, 0.89 (CI: 0.83–0.96) for EF≤40%, and 0.84 (CI: 0.73–0.94) for EF < 50%. Conclusion An AI algorithm applied to an ECG-enabled stethoscope recording in standard auscultation positions reliably detected the presence of a low EF in this prospective study of patients referred for echocardiography. The ability to screen patients with a possible low EF during routine physical examination may facilitate rapid detection of LVSD.
Packing the donor heart: Is SherpaPak cold preservation technique safer compared to ice cold storage
Bitargil, Macit , Haddad, Osama , Pham, Si M. , Garg, Neha , Jacob, Samuel , Ahmed, Magdy M. El‐Sayed , Landolfo, Kevin , Patel, Parag C. , Goswami, Rohan , Leoni, Juan , Yip, Daniel , Sareyyüpoğlu, Başar , El-Sayed Ahmed, Magdy M , Goswami, Rohan M , Leoni, Juan Carlos , Yip, Daniel S , Patel, Parag C. , Pham, Si , Garg, Neha , Goswami, Rohan

Mayo Clinic

Clinical Transplantation | May 11, 2022 | Volume: 36 | Issue: 8 | Pages: No page available

10.1111/ctr.14707 | PMID 35543679 Get It

AbstractIntroductionThe present study aimed to compare the clinical outcomes of heart transplant patients whose donor hearts were preserved with the SherpaPak controlled cold organ system versus the conventional ice storage technique.MethodsAll patients undergoing heart transplantation at our center between January 2019 and April 2021 were divided into two groups according to the technique used during donor heart preservation and transport. The first group consisted of 34 SherpaPak controlled temperature preservation patients, and the second group consisted of 47 patients where the conventional three bags and ice technique was utilized during organ transportation. The two groups were compared based on demographics, operative details, and postoperative outcomes.ResultsThere were no significant differences between the groups regarding Vasoactive Inotropic Score (VIS), Primary Graft Dysfunction (PGD), and the need for a transient pacer. However, the VIS, PGD, and pacing trends were lower in the SherpaPak patients even though the total ischemic and cardiopulmonary bypass times were significantly longer. Furthermore, SherpaPak patients exhibited a shorter stay in the ICU with no severe PGD and mortality.ConclusionThe SherpaPak donor heart preservation provides safe outcomes in heart transplant patients. Further research is needed to utilize this method for longer durations of ischemic time and expand travel distances for organ transportation.
Characterization of Lung Endothelial Cell Heterogeneity in Idiopathic Pulmonary Fibrosis (IPF)
Lee, J., Pham, Tho X., Huang, S.K., Ligresti, Giovanni , Caporarello, Nunzia , Huang, S.K.

Mayo Clinic

A107. MECHANISMS OF FIBROSIS/FIBROBLAST BIOLOGY | May 2, 2022 | Volume: No volume available | Issue: No issue available | Pages: A2313-A2313

10.1164/ajrccm-conference.2022.205.1_meetingabstracts.a2313 Get It

Bench valvular surgery in donor's hearts before transplantation: Choice versus necessity
Ahmed, Magdy M. El‐Sayed , Pham, Anthony , Sareyyüpoğlu, Başar , Pham, Si M. , Pham, Si , Pham, Anthony

Mayo Clinic

Journal of Cardiac Surgery | April 19, 2022 | Volume: 37 | Issue: 7 | Pages: 2209-2211

10.1111/jocs.16533 | PMID 35438821 Get It

Chemoenzymatic Synthesis of Homogeneous Heparan Sulfate and Chondroitin Sulfate Chimeras
Stancanelli, Eduardo , Wander, Rylee , Li, Jine , Wang, Zhangjie , Arnold, Katelyn , Su, Guowei , Kanack, Adam J. , Pham, Truong Quang , Padmanabhan, Anand , Xu, Yongmei , Kanack, Adam, Liu, Jian , Liu, Wei , Pagadala, Vijayakanth

Mayo Clinic

ACS Chemical Biology | April 14, 2022 | Volume: 17 | Issue: 5 | Pages: 1207-1214

10.1021/acschembio.2c00146 | PMID 35420777 Get It

Renal transplants with perinephric myxoid pseudotumor of fat mimicking malignancy
Pham, Mitchel, Janiszewski, Robert A, Stanton, Melissa, Nguyen, Ba D. , Nguyen, B D

Mayo Clinic

Japanese Journal of Clinical Oncology | April 6, 2022 | Volume: 52 | Issue: 6 | Pages: 654-655

10.1093/jjco/hyac038 | PMID 35383369 Get It

Bench valvular surgery in donor hearts before transplantation: Choice versus Necessity
Ahmed, Magdy M. El‐Sayed , Pham, Anthony , Sareyyüpoğlu, Başar , Pham, Anthony, Pham, Si M.

Mayo Clinic

No container title available | March 29, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.164854801.13643243/v1 Get It

Severe shortage of donor hearts has increased the mortality of patients on the transplant waiting list. However, donor hearts with valvular dysfunction are rarely used. Utilizing donor hearts with valvular lesions that can be repaired or replaced at the time of transplant will decrease waitlist mortality and offer many patients a second chance in life.