Assessing the effect of the brain-derived neurotrophic factor (BDNF) Val66Met polymorphism on mRNA transcript levels, Alzheimer’s disease (AD) risk and cognitive performance (P2.163)
Abstract Introduction The pivotal study of the extravascular implantable cardioverter‐defibrillator (EV ICD) recently demonstrated primary efficacy and safety endpoints comparable to previous ICD systems. Patient experience with this novel device has not been reported. The current study examined the standardized patient‐reported outcome (PRO) metrics of quality of life (QOL) and patient acceptance of the device. Methods The EV ICD Pivotal Study was a prospective, single‐arm, nonrandomized, global, premarket approval trial. Patients completed the 12‐Item Short Form Survey (SF‐12) QOL surveys at baseline and at 6 months following implant. Additionally, patients completed the Florida Patient Acceptance Survey (FPAS) QOL survey at 6 months. Results From baseline to 6 months, patients within the EV ICD Pivotal Study ( n = 247) reported statistically significant SF‐12 improvements in physical QOL (45.4 ± 9.4 vs. 46.8 ± 9.1 respectively, p = .020) and no changes in mental QOL (49.3 ± 10.4 vs. 50.5 ± 9.7, p = .061). No differences were noted by sex, atrial fibrillation, or the experience of ICD shock. EV ICD patients reported better total FPAS patient acceptance of their ICD than TV‐ICD or S‐ICD patients using historical norms comparisons (80.4 ± 15.7 vs. 70.2 ± 17.8, p < .0001 for S‐ICD and 73.0 ± 17.4, p = .004 for TV‐ICD). Conclusion The initial PROs for EV ICD patients indicated that patients had improvements in physical QOL from baseline to 6‐month follow‐up and markedly better overall acceptance of their ICD compared to a previous study with S‐ICD and TV‐ICD data. These initial results suggest that the EV ICD is evaluated positively by patients.
Variations in Complete Blood Count Reference Limits Among Hospitals in the US and Their Clinical Significance
Background Complete blood count (CBC) is the most common hematology test performed. Reference limits, aka normal values, are known to vary from one hospital to another. However, little is known about the values of the upper (UL) and lower (LL) limits of common elements reported in the CBC and how they differ among facilities. The objectives of our study were to report the UL and LL of CBC elements from various hospitals in the US, analyze the variances, and describe their clinical significance. Methods This study was approved by the Mayo Clinic institutional review board. We obtained the reference limits of CBCs from various hospitals using the Epic electronic medical records Care Everywhere health information exchange. CBCs from 2020-2023 were included. We included the following CBC elements: hemoglobin (Hgb; male and female), mean cell volume (MCV), white blood cell count (WBC), and platelet count (PLT). We performed descriptive statistics and calculated the coefficients of variation (COVs). In addition, we analyzed the data for clinical context using: A) World Health Organization (WHO) major criterion for polycythemia vera of Hgb >16.5 g/dL and >16.0 g/dL for males and females, respectively; B) WHO major criterion for essential thrombocytosis of PLT >450 x109/L; and C) common textbook reference limits for MCV (80-100 fL) and WBC (5-10 x109/L). Results We collected CBC reference limits from 143 hospitals across 43 states and 99 cities. Most (54.5%) hospitals were community-based, while the rest (45.5%) were academic. The statistics are shown in the Table. In general, there was minimal variance in the UL and LL of CBC elements, with COVs mostly under 8.0%. The one exception was WBC LL, in which the COV was 10.5%. There was no significant difference in the CBC reference limits between academic and community hospitals. The median Hgb UL and LL for males were 17.5 (range, 16.3-18.1) and 13.5 (range, 12.0-14.3), respectively. Similarly, the median Hgb UL and LL for females were 15.7 g/dL (range, 14.6-16.3) and 12.0 g/dL (range, 11.0-12.5), respectively. Majority (93.5%) of the hospitals' male Hgb UL exceeded 16.5 g/dL. In contrast, only few (3.6%) of the hospitals' female Hgb UL exceeded 16.0 g/dL (Figure A). The median MCV UL and LL were 99.0 fL (range, 92.2-103.0) and 80.0 fL (range, 77.0-88.0), respectively. A substantial minority (19.6%) of the hospitals' MCV UL exceeded 100 fL (Figure B). The median WBC UL and LL were 10.8 x109/L (range, 8.9-13.0) and 4.0 x109/L (range, 3.1-5.4), respectively. Most (80.4%) hospitals' WBC UL exceeded 10 x109/L (Figure C). The median PLT UL and LL were 400 x109/L (range, 317-500) and 150 x109/L (range, 125-172), respectively. Over a quarter (27.5%) of the hospitals' PLT UL were at or exceeded 450 x109/L (Figure D). Conclusions: There was minimal variance in CBC reference limits across hospitals in the US with WBC LL having the highest COV. Most MCV UL and WBC UL exceeded common textbook reference limits. Almost all male Hgb UL and over a quarter of PLT UL exceed the WHO major criteria of polycythemia vera and essential thrombocytosis, respectively. Since our findings suggest that there could be a risk of underdiagnosing these myeloproliferative neoplasms due to the commonly used reference limits, clinical context must be used when interpreting normal CBC results, especially when there is a suspicion of polycythemia vera or essential thrombocytosis.
Complete Blood Count Reporting Among Hospitals in the United States
Background Complete blood count (CBC) is the most common test performed in hematology-oncology. A typical CBC report contains over 10 elements. Simplifying the report by removing nonessential elements may benefit clinicians and patients. Little is known about what elements are reported by various hospitals in the US. The objective of our study was to describe how hospitals in the US report CBC. Methods After approval from the Mayo Clinic institutional review board, we obtained hospital CBC reported elements from the Epic electronic medical records Care Everywhere health information exchange. CBCs from 2020-2023 were included. For each hospital, we determined the city and state where it's located. We obtained the number and type of elements reported in the CBC and compared the findings between academic and community hospitals. Results We collected CBC data from 139 hospitals across 43 states and 102 cities (Figure 1). Fifty-four percent were community hospitals while 46% were academic hospitals. The median number of elements reported by all hospitals was 21 (range, 12-24). This was not different (P=0.98) between academic (median 22 [range, 12-24]) and community hospitals (median 21 [range, 14-24]; Figure 2). The distribution of hospitals according to the number of CBC elements reported were as follows: 12-15 (6%), 16-19 (13%), 20 (25%), 21(6%), 22 (18%), 23 (19%), and 24 (13%). A minority of the hospitals did not report % white blood cell differential count (9.4%) or mean platelet volume (20.9%). Nucleated red blood cell and immature granulocyte count were reported frequently, 46.0% and 56.8%, respectively. However, the frequency of reporting these four elements were similar between academic and community hospitals. Conclusions We found substantial variations in CBC reporting among US hospitals even within academic and community hospitals. Most hospitals reported 20 or more elements, twice as many as the hospitals reporting the least number of elements. There is an opportunity to simplify and standardize CBC reporting, which will minimize physician burnout and distraction as well as decrease patient concern and query.
BIOM-45. GLIOMA CSF PROTEOMICS FOR PHARMACODYNAMIC BIOMARKER AND THERAPEUTIC TARGET DISCOVERY
Abstract Cerebrospinal fluid (CSF) is emerging as an abundant source of candidate biomarkers, including proteins, for gliomas. Longitudinal CSF access may enable insights into treatment response and resistance. To that end, we have established a growing biobank of CSF samples, many of which have been obtained longitudinally via CSF access devices, such as Ommaya reservoirs, through our ongoing biomarker discovery clinical trials (NCT04692337, 04692324). We have previously presented our initial data demonstrating a conserved proteomic signature of HGG that decreased with resection and increased with recurrence. Since then, samples have been acquired throughout individual patients’ treatment course toward our goal of identifying CSF-derived biomarkers of treatment response. CSF samples obtained prior to, during, and throughout treatment underwent global proteomics analysis via the SomaScan® assay by Somalogic. Fold-changes for each protein were calculated between different timepoints and ranked for each comparison of interest. Treatment with pembrolizumab alone results in increased IL-23 (5.01x), IL-12 (4.25x), lymphocyte activation gene 3 protein (LAG3) (3.26x), and granzyme A (2.93x), suggesting potential for combination with multiple agents. Chemoradiation, with or without pembrolizumab, consistently downregulated NAD kinase, acetyl CoA transferase, and Bcl-2 and upregulated proteins related to neuronal signaling, such as neurexins and cerebellins, in addition to LAG-3, suggesting potential for synergy between chemoradiation and anti-LAG-3 antibodies currently in clinical trials. Interestingly, pembrolizumab and chemoradiation decreased MMP-12 and MMP-9 abundance as compared to chemoradiation alone (0.25x vs. 18.5x; 0.54x vs. 4.99x). Finally, bevacizumab treatment consistently increased VEGF-A (7.32x), VEGF-B (2.21x), and MMP-3 (2.99x) abundance, while decreasing the presence of our previously reported plasma-associated protein signature in CSF. In conclusion, the global CSF proteome can be longitudinally accessed to evaluate response to standard-of-care and experimental therapies. Further studies are ongoing to identify signatures of therapeutic resistance and to assess the impact of novel immunotherapeutic combinations on the CSF proteome.
Chronic safety and performance of the extravascular ICD: results from the global EV ICD Pivotal study
Abstract Background Implantable cardioverter defibrillators (ICDs) prevent sudden cardiac death in patients at high risk for ventricular arrhythmias, but conventional systems carry a risk of transvenous (TV) lead-related complications. The novel extravascular ICD (EV ICD) may reduce some of these complications, while offering anti-tachycardia pacing (ATP), pause prevention pacing, and a device of similar size and projected battery longevity as a TV ICD, by placing a lead substernally. The EV ICD Pivotal study demonstrated EV ICD safety and performance for termination of ventricular arrythmias at 6 months. Longer-term performance is unknown. Purpose To report the chronic safety and performance of the EV ICD system. Methods The extravascular implantable cardioverter defibrillator (EV ICD) Pivotal study was a prospective, international, single-arm, premarket clinical study. Patients with a class I or IIa indication for a single-chamber ICD per ESC or ACC/AHA/HRS guidelines were enrolled. Freedom from major system- and/or procedure-related complications at 18 mo was evaluated, as well as conversion of arrhythmias by anti-tachycardia pacing (ATP) or shock through all available follow up. Rates of ATP success were evaluated using the generalized estimating equation (GEE) and simple proportions. Results Implantation was attempted in 316 patients: 74.7% male, age 53.8±13.1 years, 82% primary prevention, left ventricular ejection fraction of 38.9%±15.4%, and New York Heart Association Class I (23.4%) or II/III (65.5%). Of 299 implanted patients (average follow up 16.2±7.2 mo), 19 experienced 80 spontaneous, appropriately treated arrhythmic episodes: 37 treated by ATP, 15 by ATP and shock, and 28 by shock alone with a Kaplan-Meier (KM) estimated 6.8% of patients experiencing appropriate therapy by 18 mo (Figure). Of discrete episodes treated with shock, 21/21 (100%) were successfully terminated. ATP was delivered in 12 patients, successfully treating 35/52 episodes (67.3%; GEE adjusted 59.0%). Inappropriate shocks occurred in 35 patients through all follow up, with a rate of 10.2% at 1 year. The KM estimate of freedom from major EV ICD system-or procedure-related complications rate through 18 mo was 91.9% (95% CI: 88.2% to 94.4%). The most common event was lead dislodgment (10 events in 9 patients) identified 0 to 120 days post-implant, predominantly due to anchoring technique. Conclusion The safety and effectiveness of a novel EV ICD system with a substernal lead extends through chronic follow up. Shocks were avoided in nearly half of all spontaneous episodes because of the availability of ATP.Figure