Citations

Clear

3035 citation(s) found for "Le, Kevin".

Quantitation Of Platelet Lysis, Platelet Consumption On Oxygenator And Stabilization Of Platelet Membrane With Prostacyclin And Ibuprofen During Cardiopulmonary Bypass Surgery In Dogs
Dewanjee, Mrinal K., Vogel, S R, Kaye, Michael P., Peterson, Kevin

Mayo Clinic

Thrombosis and Haemostasis | July 26, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1055/s-0038-1652777 Get It

Prostacyclin (PGI2) and Ibuprofen (IP) may preserve platelet integrity and function during cardiopulmonary bypass (CPB). Platelet consumption on bubble and membrane oxygenator, platelet lysis, and platelet microembolism were studied in 7 control, 6 PGI2-, and 5 IP-treated dogs undergoing CPB. At 18 hours after I.V. administration of autologous In-Ill-labeled platelets (300 μCi), 7 heparinized dogs (300 u/kg), and 6 dogs treated with I.V. infusion of PGI2 (25 ng/kg/min) and heparin (100 u/kg), and 5 dogs with I.V. IP (12.5 mg/kg) 15 min prior to bypass procedure underwent CPB for 1 hour. In-111 in plasma obtained from platelet lysis was determined by centrifugation at 200,000 G of serial blood samples at 5-min intervals during CPB. Hemodilution was measured with I-125-labeled serum albumin (10 μCi). Platelet deposition on oxygenator was imaged with a gamma camera and quantitated with an ionization chamber. An insignificant amount of platelet (<0.2%) was found in the heat exchanger. In-111-labeled platelet level in blood of control dogs 20 min after CPB initiation decreased to 23 ± 5% of prebypass level, 38 ± 5% in PGI2 group, and 25 ± 5% in the IP group. Plasma In-111 increased to 34±7% in control, 15±5% in PGI2 group, and 17±3% in IP group (p< 0.01). Platelet deposition on the oxygenator amounted to 20±5% of In-111 platelets in control, 11±3% of PGI2, and 13±4% in IP group (p< 0.01). These results indicate that both PGI2 and IP significantly reduce platelet consumption in oxygenator and platelet lysis during CPB. Thus PGI2 may reduce postoperative bleeding. Ibuprofen, although preserving platelet function, has a longer duration of action and, hence, systemic administration prior to CPB is not practical. Surface coating of extracorporeal surfaces with IP might be beneficial.
In Reply to Geoffrey Baird on: Utility of Antinuclear Antibody Screening by Various Methods in a Clinical Laboratory Patient Cohort
Crowson, Cynthia S. , Moder, Kevin G., Snyder, Melissa R.

Mayo Clinic

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 1 | Issue: 3 | Pages: 320-321

10.1373/jalm.2016.021600 | PMID 33626848 Get It

Utility of Antinuclear Antibody Screening by Various Methods in a Clinical Laboratory Patient Cohort
Deng, Xiaoli , Peters, Brian E., Ettore, Michael, Ashworth, Judy, Brunelle, Lynn A, Crowson, Cynthia S. , Moder, Kevin G., Snyder, Melissa R. , Peters, Brian, Ettore, Michael W, Ashworth, Judy

Mayo Clinic

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 1 | Issue: 1 | Pages: 36-46

10.1373/jalm.2016.020172 | PMID 33626797 Get It

Abstract Background Antinuclear antibody (ANA)5 testing is routinely performed during evaluation of patients with a suspected connective tissue disease (CTD), yet the question of which method is most appropriate remains controversial. The purpose of this study was to evaluate the clinical utility of ANA testing by an enzyme immunoassay (EIA), an immunofluorescence assay (IFA), and a multiplex immunoassay (MIA) in a routine laboratory population. Methods Samples (n = 1000) were collected from specimens submitted for ANA testing by EIA (Bio-Rad). All samples were subsequently analyzed by IFA (Zeus) and MIA (Bio-Rad). The sample cohort was weighted to represent the routine testing population. Diagnostic information was obtained by chart review. Results For the diagnosis of a CTD, ROC curve analysis demonstrated no significant differences between IFA (area under the curve 0.81) and EIA (0.84) (P = 0.25), with overlay of a single point for the MIA. When normalized to a specificity of approximately 90%, the sensitivities of the MIA, EIA, and IFA were 67%, 67%, and 56%, respectively. By varying the clinical cutoff, the IFA could achieve the highest sensitivity of 94%; however, the corresponding specificity was only 43%. In contrast, a strongly positive EIA had a specificity of 97%, although, at this cutoff, the sensitivity was only 40%. Conclusions Although the overall diagnostic performance of the IFA, EIA, and MIA were not statistically different, the clinical sensitivity and specificity varied dramatically based on the positive/negative cutoff. Knowledge about the performance characteristics of each method will significantly aid in the interpretation of ANA testing.
Amyotrophic lateral sclerosis–specific quality of life–short form (ALSSQOL‐SF): A brief, reliable, and valid version of the ALSSQOL‐R
Felgoise, Stephanie H. , Feinberg, Richard A. , Stephens, Helen , Clawson, Lora , Elman, Lauren , Goutman, Stephen A. , McCluskey, Leo, Russell, James W. , Tiryaki, Ezgi , Weiss, Michael D. , Simmons, Zachary , Boylan, Kevin, Goutman, Stephen A , Simmons, Zachary , Barkhaus, Paul E. , Boylan, Khrista , Caress, James B.

Mayo Clinic

Muscle & Nerve | July 20, 2018 | Volume: 58 | Issue: 5 | Pages: 646-654

10.1002/mus.26203 | PMID 30028537 Get It

ABSTRACT Introduction: The Amyotrophic Lateral Sclerosis (ALS)‐Specific Quality of Life instrument and its revised version (ALSSQOL and ALSSQOL‐R) have strong psychometric properties, and have demonstrated research and clinical utility. In this study we aimed to develop a short form (ALSSQOL‐SF) suitable for limited clinic time and patient stamina. Methods: The ALSSQOL‐SF was created using Item Response Theory and confirmatory factor analysis on 389 patients. A cross‐validation sample of 162 patients assessed convergent, divergent, and construct validity of the ALSSQOL‐SF compared with psychosocial and physical functioning measures. Results: The ALSSQOL‐SF consisted of 20 items. Compared with the ALSSQOL‐R, optimal precision was retained, and completion time was reduced from 15–25 minutes to 2–4 minutes. Psychometric properties for the ALSSQOL‐SF and its subscales were strong. Discussion: The ALSSQOL‐SF is a disease‐specific global QOL instrument that has a short administration time suitable for clinical use, and can provide clinically useful, valid information about persons with ALS. Muscle Nerve 58: 646–654, 2018
Periprocedural Cardiopulmonary Bypass or Venoarterial Extracorporeal Membrane Oxygenation During Transcatheter Aortic Valve Replacement: A Systematic Review
Vallabhajosyula, Saraschandra , Patlolla, Sri Harsha , Vallabhajosyula, Saarwaani , Barsness, Gregory W. , Greason, Kevin L. , Holmes, David R. , Eleid, Mackram F. , Sandhyavenu, Harigopal , Dunlay, Shannon M. , Vallabhajosyula, Saraschandra , Harsha Patlolla, Sri

Mayo Clinic

Journal of the American Heart Association | July 9, 2018 | Volume: 7 | Issue: 14 | Pages: No page available

10.1161/jaha.118.009608 | PMID 29987125 Get It

Background There are limited data on the use of venoarterial extracorporeal membrane oxygenation ( VA ‐ ECMO ) or cardiopulmonary bypass ( CPB ) to provide hemodynamic support periprocedurally during transcatheter aortic valve replacement. This study sought to evaluate patients receiving transcatheter aortic valve replacement with concomitant use of CPB / VA ‐ ECMO . Methods and Results We systematically reviewed the published literature from 2000 to 2018 for studies evaluating adult patients requiring CPB / VA ‐ ECMO periprocedurally during transcatheter aortic valve replacement. Studies reporting short‐term and long‐term mortality were included. Given the significant methodological and statistical differences between published studies, meta‐analysis of the association of CPB / VA ‐ ECMO with mortality was not performed. Of the 537 studies identified, 9 studies representing 5191 patients met our inclusion criteria. Median ages were between 75 and 87 years with 33% to 75% male patients. Where reported, the Edwards SAPIEN ™ transcatheter heart valve was the most frequently used. A total of 203 (3.9%) patients received periprocedural hemodynamic support with CPB / VA ‐ ECMO . Common indications for CPB / VA ‐ ECMO included left ventricular or aortic annular rupture, rapid hemodynamic deterioration, aortic regurgitation, cardiac arrest, and left main coronary artery obstruction. The use of CPB / VA ‐ ECMO was predominantly an emergent strategy and was used for durations of 1 to 2 hours. Short‐term mortality (in‐hospital and 30‐day) was 29.8%, and 1‐year mortality was 52.4%. Major complications such as bleeding, vascular injury, tamponade, stroke, and renal failure were noted in 10% to 50% of patients. Conclusions CPB / VA ‐ ECMO was used in 4% in the early experience of patients undergoing transcatheter aortic valve replacement, most commonly for periprocedural complications. There are limited data on preprocedural planned use of VA ‐ ECMO , and the characteristics of this population remain poorly defined.
Responses to Topical Diphenylcyclopropenone as an Adjunct Treatment for In-Transit Melanoma: A Tertiary Referral Center Experience
Veverka, Kevin K. , Jakub, James W. , Baum, Christian L. , Jakub, James W

Mayo Clinic

Dermatologic Surgery | July 7, 2018 | Volume: 44 | Issue: 12 | Pages: 1501-1508

10.1097/dss.0000000000001603 | PMID 29985863 Get It

BACKGROUND In-transit cutaneous metastases occur in 5% to 10% of patients with melanoma. Recently, topical diphenylcyclopropenone (DPCP) has been described as a treatment option. OBJECTIVE To evaluate efficacy of DPCP in treatment of in-transit cutaneous melanoma. METHODS The authors retrospectively reviewed the records of 13 consecutive patients with in-transit metastases treated with topical DPCP between March 1, 2013, and January 31, 2017. The authors recorded the response of in-transit cutaneous melanoma lesions treated with DPCP measured by clinical examination. RESULTS Among the 13 patients, 9 patients completed at least a 1-month course of DPCP treatment. Of these 9 patients, 6 (66.7%) maintained either stable disease or had a partial or complete regression, and 3 (33.3%) had progressive disease. Patients with less burden of disease (e.g., <15 lesions) responded more favorably than those with a greater burden of disease (e.g., >25 lesions or plaques). Both patients who received DPCP alone had progression of their cutaneous lesions. One patient who did not become sensitized to DPCP died within 2 months, and his anergy likely reflecting immense burden of disease. CONCLUSION Topical DPCP is a low-cost, patient-applied treatment option for in-transit melanoma, most effective for patients with relatively low tumor burden and localized disease.
Psychometric Properties of the Modified Brief Fatigue Inventory and FACIT-Fatigue in Individuals With Cancer of the Head and Neck
Eden, Melissa M. , Kunkel, Kevin

Mayo Clinic

Rehabilitation Oncology | July 3, 2018 | Volume: 34 | Issue: 3 | Pages: 97-103

10.1097/01.reo.0000000000000024 Get It

Purpose: The purpose of this study was to establish the test-retest reliability and concurrent validity of the Modified Brief Fatigue Inventory (MBFI) and the Functional Assessment of Chronic Illness Therapy–Fatigue (FACIT-Fatigue) scale in a population of patients treated for cancers of the head and neck. Methods: The MBFI and the FACIT-Fatigue were administered to 65 participants in a tertiary medical center with a diagnosis of head and neck cancer (HNC), skin cancer, and thyroid cancer who had undergone surgery within the past 3 months and/or were currently receiving radiation and/or chemotherapy treatments. Test-retest reliability, internal consistency, and concurrent validity are reported. Results: For the HNC group, the MBFI had an intraclass correlation coefficient (ICC) of 0.825 (0.68-0.91) and an internal consistency of 0.828. The FACIT-Fatigue ICC was 0.866 (0.75-0.93) and internal consistency was 0.874. The MBFI ICC for the skin and thyroid cancer groups was 0.932 (0.76-0.98) and 0.880 (0.60-0.97), and internal consistency of 0.929 and 0.880, respectively. The FACIT-Fatigue ICC for the skin and thyroid cancer groups was 0.945 (0.81-0.99) and 0.941 (0.81-0.98), and the internal consistency was 0.945 and 0.941, respectively. The Spearman ρ correlation coefficient for concurrent validity of the MBFI and FACIT-Fatigue was −0.871 for HNC, −0.838 for skin cancer, and −0.903 for thyroid cancer. Conclusions: The MBFI and the FACIT-Fatigue demonstrate good test-retest reliability, internal consistency, and concurrent validity for all subgroups. The FACIT-Fatigue demonstrates a slight advantage over the MBFI with respect to test-retest reliability and internal consistency.
634 Convective Radiofrequency Thermal Therapy (Rezum®) Effectively Treats Lower Urinary Tract Symptoms Due to Benign Prostatic Hyperplasia Regardless of Obesity While Preserving Erectile and Ejaculatory Function
Köhler, Tobias , McVary, Kevin T. , Helo, Sevann , Tadros, Nicholas N. , Gupta, Nikhil

Mayo Clinic

The Journal of Sexual Medicine | June 29, 2018 | Volume: 15 | Issue: Supplement_3 | Pages: S367-S368

10.1016/j.jsxm.2018.04.541 Get It

Emergency Manual Implementation in a Large Academic Anesthesia Practice: Strategy and Improvement in Performance on Critical Steps
Gleich, Stephen J. , Pearson, Amy C. S. , Lindeen, Kevin C., Höfer, R , Gilkey, George D., Borst, Luann F., Haile, Dawit T. , Martin, David P. , Hofer, Ryan E, Pearson, Amy C S , Gilkey, George D.

Mayo Clinic

Anesthesia & Analgesia | June 29, 2018 | Volume: 128 | Issue: 2 | Pages: 335-341

10.1213/ane.0000000000003578 | PMID 29958214 Get It

BACKGROUND: The use of cognitive aids, such as emergency manuals (EMs), improves team performance on critical steps during crisis events. In our large academic anesthesia practice, we sought to broadly implement an EM and subsequently evaluate team member performance on critical steps. METHODS: We observed the phases of implementing an EM at a large academic anesthesia practice from 2013 to 2016, including the formation of the EM implementation team, identification of preferred EM characteristics, consideration of institution-specific factors, selection of the preferred EM, recognition of logistical barriers, and staff education. Utilization of the EM was tested in a regular clinical environment with all available resources using a standardized verbal simulation of 3 crisis events both preimplementation and 6 months postimplementation. Individual members of the anesthesia team were asked to verbalize interventions for specific crisis events over 60 seconds. RESULTS: We introduced a customized version of the Stanford Emergency Manual on January 26, 2015. Fifty-nine total participants (equal proportion of anesthesiology attending physicians, resident physicians, certified registered nurse anesthetists, and student registered nurse anesthetist staff) were surveyed in the preimplementation phase and 60 in the 6-month postimplementation phase. In the postimplementation phase, a minority (41.7%) utilized the EM for the verbal-simulated crisis events. Those who used the EM performed better than those who did not (median 21.0 critical steps out of a possible 30 total steps [70.0%], interquartile range 19–25 vs 18.0 critical steps verbalized [60.0%], interquartile range 16–20; P < .001). Among all subjects, the median number of critical steps verbalized was 16 (53.3%) preimplementation and 19.5 critical steps (65.0%) postimplementation. CONCLUSIONS: Implementation of an EM in a large academic anesthesia practice is not without challenges. While full integration of the EM was not achieved 6 months after implementation, verbalization of critical steps on 3 simulated crisis events improved when the EM was utilized.